• Title/Summary/Keyword: refrigerator

Search Result 1,080, Processing Time 0.028 seconds

Smart refrigerator to inform the expiration date (유통기한을 알려주는 스마트 냉장고)

  • Ryu, Ji-wan;Bae, Dong-ki;Lee, Daesung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.442-444
    • /
    • 2015
  • While Internet of things(IoT) era arrives, the communication capable world between various smart devices is realized. In this study, to reduce the inconvenience of daily life, in research on a smart refrigerator, it is possible to confirm the presence or absence of abnormality of the contents by sending the expiration date of the contents in the refrigerator to the user's smart phone.

  • PDF

Investigation on-board pulse tube refrigerator for high temperature superconducting rotor (고온 초전도 회전자 냉각을 위한 탑재형 맥동관 냉동기 연구)

  • 남중원;정상권
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.316-319
    • /
    • 2003
  • Cryogenic refrigerator system is necessary for cooling the superconducting rotor. Among the various cryogenic refrigerator systems, on-board hybrid pulse tube cryocooler is designed for cooling the superconducting rotor. Hybrid pulse tube cryocooler is composed of pulse tube cryocooler and Stirling cryocooler. This Stirling cryocooler precools the middle point of regenerator to obtain lower temperature at cold part of pulse tube cryocooler. In this paper, only Stirling cryocooler is on-boarded then rotated by motor for various rotating speeds and heat loads at cold part of Stilting cryocooler. Through this experiment the feasibility of the on-board cryocooler is investigated.

  • PDF

Numerical Analysis of Fluid Flow in Freezer Duct of Refrigerator (냉장고의 냉동실내 냉기 덕트 내부의 유동해석)

  • 엄윤섭;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.509-514
    • /
    • 2000
  • A numerical study has been performed to design duct parameters in the freezer of a domestic refrigerator. The visualization results of FDM analysis using the standard k-$\varepsilon$ model with inlet boundary conditions modelled in this paper show good agreements with the experimental ones in prediction overall flow characteristics. Dominant vortex flows are found in the left upper and right lower corners, while there exists large turbulent kinetic energy around the fan and right upper side of the fan. It, in turn, has effects on the performance and noise. It is recommended to locate the outlet far away from the fan in order to reduce the noise level.

  • PDF

A Diagnostic Technique for the Air Flow Characteristics in Refrigerators using PIV (PIV에 의한 냉장고 기류특성 평가방법)

  • Kim, Seok-Ro;Doh, Deog-Hee;Lee, Jae-Keun;Kim, Kyung-Chun
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.576-584
    • /
    • 2007
  • A PIV(Particle Imaging Velocimetry) diagnostic technique for the evaluation of the flow characteristics in refrigerator is introduced. Smoke particles of which density is small enough to follow up the air flow are used for visualization of the air flows in the refrigerators. A rectangular room model is tested for the verifications of the dignostic technique. By evaluating the turbulent intensity and the deviation value of the turbulent intensity distribution that were obtained from PIV results, an optimal ventilating condition is suggested. The constructed technique is used for the diagnostics on the flow of an actual refrigerator. It has experimentally proved that the present technique is able to evaluate the ventilation conditions of refrigerators.

  • PDF

Multiple Units Control of Boiler and Refrigerator in HVAC System (공조용(空調用) 열원기기(熱源機器)의 대수분리(臺數分離) 제어(制御)에 관한 연구(硏究))

  • Sohn, J.Y.;Kim, H.S.;Ahn, B.W.;Shin, Y.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-10
    • /
    • 1992
  • The purpose of this paper is to provide an efficient method of operating and designing HVAC systems for reasonable energy consumption in building. Accroding to the conditions of indoor temperature and humidity, and the methods of dividing and grouping the capacity of boiler and refrigerator, the amount of their annual energy consumptions is simulated by using an energy analysis program which is developed in this paper, and opatimal design methods of HVAC system are suggested as well.

  • PDF

Thermal Performance Analysis of Reciprocating Compressors for Refrigerator-freezers (냉장고용 왕복동 압축기의 성능 해석)

  • KIM, MAN-HOE
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.2
    • /
    • pp.236-243
    • /
    • 2016
  • This paper presents a simple thermo-physical model of reciprocating compressors for household refrigerator-freezers. The compressor model has been developed based on thermodynamic principles and large data sets from the compressor calorimeter tests. The input data are compressor geometry (displacement and clearance volume), compressor speed, suction pressure and temperature, discharge pressure, and ambient temperature. The model can estimate mass flow rate and compressor power consumption within 3.0% accuracy, which is not much larger than measurement errors associated with calorimeter testing under ideal conditions.

Dual Compressor Inverter System for Refrigerator Vehicles (냉장 차량용 듀얼 컴프레서 인버터 시스템)

  • Han, Keun-Woo;Kim, Seong-Gon;Lee, Chung-Hoon;Choi, Myoung-Hyun;Jung, Young-Gook
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.292-293
    • /
    • 2017
  • In the single type mechanical compressor mounted on the refrigerated vehicle, one compressor is responsible for the refrigerator function of the air conditioner and the refrigerator, so it is difficult to maintain a certain refrigeration temperature in the summer. Particularly, in a mechanical compressor using an engine as a power source, the refrigeration quality is deteriorated due to unstable rotation of the engine. In this paper, we propose a three - phase inverter of a dual compressor system that uses an electric compressor separately from a mechanical compressor of a refrigerated vehicle. The output characteristics of the developed inverter were verified through a vehicle air conditioning simulator.

  • PDF

A Study on Reduction of Refirigerant Noise in Household Refrigerator (냉장고 냉매 소음의 저감에 관한 연구)

  • Choi, Seong-Won;Hwang, Won-Gul;Sul, Seoung-Yun;Im, Hyung-Eun;Kim, Sang-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1062-1066
    • /
    • 2004
  • In this study, refrigerant noise at connection of capillary tube and evaporator is investigated. Mechanism of refrigerant noise generation is examined in side-by-side type home refrigerator with two evaporators. It is found that the refrigerant noise is generated during refrigeration room fan-off (R-fan of) for that type refrigerator. The reason is that mass flow rate gets down during R-fan of and flow pattern is changed at outlet of capillary tube. We suggest designs for reduction of refrigerant noise with horizontal double expansion device, muffler, and accumulator. To evaluate those improved designs, sound quality index is used.

  • PDF

Evaluation of the Sound Quality for the Refrigerator by Consumer's Sense of Hearing (소비자 청음 평가를 통한 냉장고 음질 평가)

  • Joo, Jae-Man;Lee, Jea-Won;Lee, Jin-Kyung;Oh, Sang-Kyong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.145-148
    • /
    • 2004
  • Until now, product mostly has revealed physical quantities created by the standpoint of engineers. Consumers, however, perceive and evaluate products on the non-physical characteristics, such as feelings, emotions, and experiences in different social and cultural situations. Especially, for the household appliances such as a refrigerator, the sound is heavily related to the satisfaction of a customer who is a real user of the product and is very important factor to decide purchasing as well as visual design. Therefore, in this research, not only the simple sound pressure level but also the consumer's sense of hearing evaluate the noise from the refrigerator. And also, in order to improve the quality of sound through the design change, the consumer's evaluation is analyzed and related to the engineering quantities.

  • PDF

Selection of working fluid for cryosurgical probe considering biological heat transfer

  • Hwang, Gyu-Wan;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.4
    • /
    • pp.46-49
    • /
    • 2007
  • This paper describes the sensitive cooling performance change of J-T refrigerator for cryosurgical probe due to its working fluid. The analytical results of using 50 bar nitrous oxide are compared with the case of 300 bar argon. Bio-heat equation is numerically solved to investigate the effect of the probe temperature and the cooling power of the J-T refrigerator. The refrigerator using 50 bar nitrous oxide has larger cooling power above 185 K than the one with 300 bar argon, which enables fast cooling at early stage of cryosurgery, but the biological tissue away from the probe tends to be cooled slowly after the probe reaches its lowest operating temperature. When the repeated freeze-thaw cycle is employed for main tissue destruction mechanism, using high pressure nitrous oxide is more advantageous than argon if the freezing operation is within 2-3 minutes. The probe with high pressure argon is more suitable for the case of longer freeze-thaw cycle with fewer repetitions.