• 제목/요약/키워드: refrigerator

검색결과 1,078건 처리시간 0.025초

1/4파장 열음향 냉동기의 공명관 길이 의존 특성 연구 (An Experimental Study that depend on the Resonance Tube Length for a Thermoacoustic Refrigerator of 1/4 wave)

  • 송규조;박종호;고득용;박성제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.229-234
    • /
    • 2001
  • The thermoacoustic refrigerator bas not only considerable possibility but also commercial usability, because it bas high reliability, lower vibration, no moving part, and can easily be constructed. In this study, the resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, varying length of the resonance tube to 400mm, 500mm, 600mm, 700mm. In order to determine the optimum resonance tube length and the frequency, the $\lambda/4$ thermoacoustic engine and the similar apparatus of Wheatly type refrigerator were constructed. It was used air as a coolant. in the fifth harmonic, it was taken the highest ${\Delta}t$ that was $56.3^{\circ}C$ at 626Hz in 400mm tube with 40mm stack.

  • PDF

1/2파장 열음향 냉동기의 공명관 길이 의존 특성 연구 (An Experimental Study that depend on the Resonance Tube Length for a Thermoacoustic Refrigerator of 1/2 wave)

  • 송규조;박종호;고득용;김효봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.217-222
    • /
    • 2001
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In this study, the resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, varying the length of Resonant Tube to 400mm $\sim850mm$. In order to determine the optimum position of stack in the resonance tube and the frequency, the simple $\lambda/2$ thermoacoustic refrigerator was constructed. It was used air as a coolant. in the fifth harmonic, it was taken the highest ${\Delta}t$ that was $52.6^{\circ}C$ at 827Hz in 400mm tube with 40mm stack.

  • PDF

1/4파장 열음향 냉동기의 제작 및 성능시험 (The Construction and Investigation of The 1/4 Wavelength Thermoacoustic Refrigerator)

  • 송규조;박종호;이성노;이재호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.223-228
    • /
    • 2001
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In this study, The thermoacoustic refrigerator were constructed. The apparatus is capable of driving closed systems containing He or air at mean pressures ranging from 1-9.3 bar, at frequencies ranging from 100-1000Hz. The resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, The resonance tube is 340.5mm in length. In case of using air as a coolant. Freezing frequency is 174Hz, In case of using He as a coolant Freezing frequency is 625Hz. Using He, The cold-part temperature of the heat exchanger fell to $-23.7^{\circ}C$ after 120 minutes in 70W.

  • PDF

Optimal Inner Case Design for Refrigerator by Utilizing Artificial Neural Networks and Genetic Algorithm

  • Zhai, Jianguang;Cho, Jong-Rae;Roh, Min-Shik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권7호
    • /
    • pp.971-980
    • /
    • 2010
  • In this paper, an artificial neural network (ANN) was employed to build a predicting model for refrigerator structure. The predicting model includes three input variables of the plaque depth (D), width (W) and interval distance(S) on the inner wall. Finite element method was utilized to obtain the data, which would be necessary for the ANN training process. Finally, a genetic algorithm (GA) was applied to find the optimal parameters that leaded to the minimum inner case deformation under operating condition. The optimal combination found is the depth(D) of 2.63mm, the width(W) of 19.24mm and the interval distance(S) of 49.38mm which leaded to the smallest deformation of 1.88mm for the given refrigerator model.

공기 압축기와 암모니아 냉동기의 진동 분석 사례 (Case study of the Vibration Analysis of the Compressor Ammonia Refrigerator)

  • 장용석;임장익;김병수;김효중;최병근
    • 동력기계공학회지
    • /
    • 제12권4호
    • /
    • pp.52-56
    • /
    • 2008
  • The necessity of diagnosis of the rotating machinery which is widely used in the industry is increasing. Because vibration diagnosis can avoid sudden breakdown of machine and reduce the maintenance costs. In chemical factory, Air-compressor and refrigerator which can affect the performance and capacity of output are important machine. Therefore, in this paper, the vibration of reassembled air-compressor and refrigerator after explosion is measured for checking the machine condition. The result of diagnosis and solution is discussed in this paper.

  • PDF

주관적 평가방법을 적용한 냉장고 소음대책 수립 (A Strategy of Refrigerator Noise Control by Using Subjective Assessment)

  • 정광일;김석관;이종구;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.191-196
    • /
    • 2001
  • The conventional methods for noise control attempts to simply reduce the level of product noise. This has been common practice in noise control industry. However, it is very straightforward common sense that we have consider human perception on noise. In this paper, we propose a noise control strategy which takes into account the subjective perception of product noise. We especially has concentrated on a refrigerator noise. The proposed method is composed of 3 steps. Firstly, the actual refrigerator noise signal is measured. Then, to make the sample noise set for subjective assessment the noise signal is edited in 1/3 octave bands. Finally, we establish a strategy of refrigerator noise control by using the results from subjective assessment of these noise signals

  • PDF

B/F형 냉장고 냉동실의 결빙원인에 관한 연구 (Fluid flow in the freezing compartment of the B/F Refrigerators)

  • 양수영;김윤규;박재성;정호윤;이연원
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.530-533
    • /
    • 2008
  • Refrigerators have some frost related problems in a freezing compartment. The frost formation in the refrigerator gives customers a bad impression concerning quality problems. Therefore, many engineers have been studying the optimum solution to avoid frost formation. But the problem of frost formation is very complex and hard to approach to the answer. The frost generation of a household refrigerator have been widely known that is closely related to the distribution of temperature inside the compartment. The distribution depends on the cold air circulation inside the refrigerator. So frost problem can be reduced and energy consumption efficiency also improved through optimization of air flow fields inside the freezing compartment. In this paper, numerical simulation has been carried out to check fluid flow. The variation of temperature at the walls was measured and quantitative analysis of frost generated from the freezing compartment was carried out. Through comparison between simulation and experiment, some correlation revealed.

  • PDF

3 밸브형 맥동관 냉동기의 작동 해석 (Analysis of the Operation of a 3 Valve-type Pulse Tube Refrigerator)

  • 송영식;조경철;정평석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.335-340
    • /
    • 2000
  • A 3 valve-type pulse tube refrigerator optains its cooling effect from pressure drop by releasing the part of the charged gas through hot end nozzle. The objective of this study is to analyze the performance and to find an optimal expansion pressure of the 3 valve-type pulse tube refrigerator. It is assumed that gas lumps are not mixed and periodically repeat the adiabatic compression and expansion processes. And the nodal model is applied for the analysis of the regenerator. As the result of analysis, the optimum pressure at the end of expansion process was about 80-90% of the maximum pressure.

  • PDF

양문형 냉장고 냉동실 결빙원인해석 및 최소화 방안 (Investigation on Freezing in the Freezing Compartment of a Side by Side Refrigerator)

  • 김윤규;정호윤;최윤환;이연원
    • 동력기계공학회지
    • /
    • 제14권1호
    • /
    • pp.34-39
    • /
    • 2010
  • A side by side refrigerator is popularly used one among electric home appliances according to the rise of the customer's living standard. But the frost problem in freezing compartment comes out whenever we develop the high quality refrigerator. In this research, internal flow simulation and temperature measurement were carried out by using CFD and T-type thermocouple respectively in order to understand freezing mechanism. It was revealed that the amount of frost beneath the 1st and 2nd shelves is approximately 40% of total frost and the cause of frost generation is due to bad circulation of low speed cold flow. Using this analysis, the shapes of outlets under shelves are modified. So, the amount of frost in this modified model decreases 6% comparing to original one.

깃 끝단 개선을 통한 냉장고용 축류홴 저소음화에 대한 연구 (Study on Noise Reduction of an Axial Fan for Refrigerator through Modification of the Blade Tip)

  • 김창준;전완호;정용규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.639-644
    • /
    • 2002
  • In this paper, a successful noise reduction of an axial flow fan for a refrigerator is presented. The vortex sheet generated at the blade tip of fan was suppressed by changing the shape of the tip. The structure of vortex sheet and detailed flow pattern around the fan were studied by two-dimensional LDV(Laser-Doppler Velocimetry). Effective ways to work out the result as mentioned above are to make the tip of the blade varied in thickness and to have elliptical shapes. To seek the optimal value fur the shape of new fan, several cases were examined. Through the application of the methods, the refrigerator became less noisy by 3.8 dB(A) in terms of air-borne noise produced only by the axial flow fan compared to the current one.

  • PDF