• 제목/요약/키워드: refrigerated warehouse

검색결과 12건 처리시간 0.023초

냉장물류센터 내 운반장비 운영계획에 관한 연구 (Transporter Operation Planning for Refrigerated Warehouse Using Simulation Method)

  • 황흥석;김호균;조규성
    • 산업공학
    • /
    • 제15권4호
    • /
    • pp.382-390
    • /
    • 2002
  • This paper deals with planning of order-picking warehouse considering the batch order picking for transportation equipments to pick consumers' orders at a time among order-picking methods and a systematic approach method in order to analyze the order-picking warehouse which can perform optimal operation. To estimate an operating time of transportation equipments to carry out order-picking, this paper suggests three operations : first, to design the refrigerated warehouse using warehouse design parameters, second, to calculate the travel time of transporters considering four types of times with the probabilistic picking frequency, and third, to analyze an order-picking warehouse to construct a simulation model with the AutoMod as a simulation tool. We apply this model to a refrigerated warehouse company in Busan.

생애비용 분석을 통한 외벽 및 단열재료 종류별 냉동냉장창고 외피의 적정 단열두께 산정 (Optimized Insulation Thickness of the Refrigerated Warehouse with Different Envelope Structures and Insulation Materials by L.C.C. Analysis)

  • 강승희;구보경;황혜주;석호태;안홍섭;송승영
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.372-381
    • /
    • 2003
  • This study aims to find out the optimized insulation thickness of refrigerated warehouse with different envelope structures (RC and PC wall) and insulation materials (urethane and icynene). Each of them is compared according to the thickness of insulation (100, 150, 200 mm/50 or 250 mm) and the temperature of cold storage room (0, -6, -15$^{\circ}C$). As results, it is proved to have the best economical efficiency in life cycle cost when PC wall with thickness of 100 mm (0 and -6$^{\circ}C$) and 150 m (-15$^{\circ}C$) urethane, respectively, are applied.

냉동냉장창고 침기방지장치의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Infiltration Prevent Devices in refrigerated Warehouse)

  • 곽현철;석호태;송승영;황혜주;안홍섭
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.55-62
    • /
    • 2002
  • In this paper, several types of infiltration prevention devices that are currently in use have been studied through experimental investigation. Firstly, the types of infiltration prevention devices were defined through investigating actual conditions of refrigerated warehouse in operates. Based on this investigation results, measured change of temperature and figured out air change rates of the type of infiltration prevention devices by using scale down model. After that, found the amount of air change rate in order to estimate the load of air change easily in facility plan.

Operation of Smart Refrigeration Logistics Center based on Cold Chain System

  • Cho, Gyu-Sung
    • Journal of Multimedia Information System
    • /
    • 제5권4호
    • /
    • pp.229-234
    • /
    • 2018
  • This paper focuses on the frozen storage warehouse located in Busan area, and it is because Busan is the most dense area in Korea. Busan is a port city, and almost all of the frozen refrigerated cargo imported from abroad is concentrated. By taking advantage of its strength as a fishery industry as well as importing, Busan is building the largest international fishery logistics base in Northeast Asia and plays an important role in the export of refrigerated cargo is. Therefore, although the freezing and chilling facilities seem to be developed with the latest technology, the reality is not so. Most of them are functioning as a warehouse, that is, a storage function, and a considerable number of refrigerated warehouses are in a state of aging. Therefore, in this paper, the facility and function restructuring of the freezing storage warehouse have been set as a solution task, and the introduction of the cold chain system containing the latest smart technology has been proposed as a solution.

냉장창고설비의 픽킹 및 재 보충설비계획문제의 연구 (A Study on Refrigerate Warehouse Facility Performance Planning for Picking and Replenishing Facility Using Simulation Method)

  • 황흥석;조규성;최배석
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2003년도 춘계공동학술대회
    • /
    • pp.1035-1041
    • /
    • 2003
  • Recent studies among various activities taking place in order-picking warehouse system have shown various researches to reduce the order-picking costs occupying more than half the total costs. One way of improving the warehouse system performance is to separate from a picking area and a reserve area in one unit rack. This study is concerned on the performance evaluation model for picking and replenishing facility of refrigerated warehouse using simulation method. In this study, we developed a mathematical model to compute the system performance solve this problem using simulation method. We demonstrate the system performance using AutoMod Simulator and verify the results to compare mathematical results of the system performance of warehouse system. A systematic approach proposed n this study for an optimal planning of order-picking warehouse is known as an effective method for planning of order-picking warehouse and a performance evaluation problem considering both picking and replenishment.

  • PDF

LNG 냉열을 이용한 냉장·냉동 창고 모사에 관한 연구 (A Study of Simulation on the Refrigerated Warehouse System Based on the Cold Energy of Lng Using the Pro-Ii Simulator)

  • 한단비;김윤지;염규인;신재린;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제28권4호
    • /
    • pp.401-406
    • /
    • 2017
  • When Liquified Natural Gas (LNG) is vaporized into NG for industrial and household usage, tremendous cold energy was transferred from LNG to seawater during phase-changing process. This heat exchanger loop is not only a waste of huge cold energy, but will cause thermal pollution to the coastal fishery area also when cold water was re-injected into the sea. In this study, an innovation design has been performed to reclaim the cold energy for -35 to $62^{\circ}C$ refrigerated warehouse. Conventionally, this was done by installing mechanical refrigeration systems, necessitating tremendous electrical power to drive temperature. A closed loop LNG heat exchangers in series was designed to replace the mechanical or vapor-compression refrigeration cycle by process simulator. The process simulation software of PRO II with provision has been used to simulate this process for various conditions, what to effect on cold energy and used energy for re-liquefaction and evaporation process. In addition, through analysis the effect of the change of LNG supply pressure on sensible and latent heat, optimum operational conditions was suggested for LNG cold energy warehouse.

효율적인 냉동창고 재고관리를 위한 모바일 프레임워크의 설계 및 구현 (Design and Implementation of a Mobile Framework for Efficient Inventory Management of Refrigerated Warehouses)

  • 반재훈;김동현
    • 한국정보통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.341-346
    • /
    • 2013
  • 물류의 입출고 및 재고현황을 신속하고 정확하게 관리하는 것이 매우 중요한 냉동창고 재고관리 프로그램은 폐쇄 클라이언트 서버 환경인 레거시 시스템에서 운용되고 있어 유지보수에 많은 비용과 인력이 소요된다. 이로 인해 소비자인 화주에게 제공되는 서비스가 전무하며, 기본적인 수 발주를 위해서 팩스나 전화를 이용하므로 업무 프로세스가 낙후되어 업무가 비효율적이며 오류와 부정확성 등의 문제가 발생하고 있다. 본 논문에서는 낙후된 기존 시스템의 문제와 냉동창고 소비자인 화주에게 제공되는 서비스가 없는 문제를 해결하기 위해 기존 시스템을 그대로 유지하면서 모바일로 화주에게 다양한 서비스를 제공하는 모바일 프레임워크를 설계하고 구현한다. 구현된 시스템에서 화주는 모바일기기를 이용하여 수 발주 업무, 재고량 조회 등의 서비스를 제공받아 관리 업무의 신속성과 정확성을 보장하였으며 다양한 서비스를 화주에게 제공함으로써 사용자만족도를 향상시켰다.

LNG 냉열활용을 위한 열교환기의 배열 형태가 냉동창고 성능에 미치는 연구 (Effect of the Array Type of Heat Exchangers on Performance of Refrigerated Warehouse for Utilization of LNG Cold Energy)

  • 한단비;김윤지;변현승;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.282-288
    • /
    • 2019
  • When liquefied natural gas (LNG) is vaporized to form natural gas for industrial and household consumption, a tremendous amount of cold energy is transferred from LNG to seawater as a part of the phase-change process. This heat exchange loop is not only a waste of cold energy, but causes thermal pollution to coastal fishery areas by dumping the cold energy into the sea. This project describes an innovative new design for reclaiming cold energy for use by cold storage warehouses (operating in the 35 to $62^{\circ}C$ range). Conventionally, warehouse cooling is done by mechanical refrigeration systems that consume large amounts of electricity for the maintenance of low temperatures. Here, a closed loop LNG heat exchange system was designed (by simulator) to replace mechanical or vapor-compression refrigeration systems. The software PRO II with PROVISION V9.4 was used to simulate LNG cold energy, gas re-liquefaction, and the vaporized process under various conditions. The effects on sensible and latent heats from changes to the array type of heat exchangers have been investigated, as well as an examination of the optimum.

난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화 (Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space)

  • 성순경
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.