• Title/Summary/Keyword: refrigerated warehouse

Search Result 12, Processing Time 0.034 seconds

Transporter Operation Planning for Refrigerated Warehouse Using Simulation Method (냉장물류센터 내 운반장비 운영계획에 관한 연구)

  • Hwang, Heung-Suk;Kim, Ho-Gyun;Cho, Gyu-Sung
    • IE interfaces
    • /
    • v.15 no.4
    • /
    • pp.382-390
    • /
    • 2002
  • This paper deals with planning of order-picking warehouse considering the batch order picking for transportation equipments to pick consumers' orders at a time among order-picking methods and a systematic approach method in order to analyze the order-picking warehouse which can perform optimal operation. To estimate an operating time of transportation equipments to carry out order-picking, this paper suggests three operations : first, to design the refrigerated warehouse using warehouse design parameters, second, to calculate the travel time of transporters considering four types of times with the probabilistic picking frequency, and third, to analyze an order-picking warehouse to construct a simulation model with the AutoMod as a simulation tool. We apply this model to a refrigerated warehouse company in Busan.

Optimized Insulation Thickness of the Refrigerated Warehouse with Different Envelope Structures and Insulation Materials by L.C.C. Analysis (생애비용 분석을 통한 외벽 및 단열재료 종류별 냉동냉장창고 외피의 적정 단열두께 산정)

  • 강승희;구보경;황혜주;석호태;안홍섭;송승영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.372-381
    • /
    • 2003
  • This study aims to find out the optimized insulation thickness of refrigerated warehouse with different envelope structures (RC and PC wall) and insulation materials (urethane and icynene). Each of them is compared according to the thickness of insulation (100, 150, 200 mm/50 or 250 mm) and the temperature of cold storage room (0, -6, -15$^{\circ}C$). As results, it is proved to have the best economical efficiency in life cycle cost when PC wall with thickness of 100 mm (0 and -6$^{\circ}C$) and 150 m (-15$^{\circ}C$) urethane, respectively, are applied.

A Study on the Performance Evaluation of Infiltration Prevent Devices in refrigerated Warehouse (냉동냉장창고 침기방지장치의 성능평가에 관한 연구)

  • 곽현철;석호태;송승영;황혜주;안홍섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • In this paper, several types of infiltration prevention devices that are currently in use have been studied through experimental investigation. Firstly, the types of infiltration prevention devices were defined through investigating actual conditions of refrigerated warehouse in operates. Based on this investigation results, measured change of temperature and figured out air change rates of the type of infiltration prevention devices by using scale down model. After that, found the amount of air change rate in order to estimate the load of air change easily in facility plan.

Operation of Smart Refrigeration Logistics Center based on Cold Chain System

  • Cho, Gyu-Sung
    • Journal of Multimedia Information System
    • /
    • v.5 no.4
    • /
    • pp.229-234
    • /
    • 2018
  • This paper focuses on the frozen storage warehouse located in Busan area, and it is because Busan is the most dense area in Korea. Busan is a port city, and almost all of the frozen refrigerated cargo imported from abroad is concentrated. By taking advantage of its strength as a fishery industry as well as importing, Busan is building the largest international fishery logistics base in Northeast Asia and plays an important role in the export of refrigerated cargo is. Therefore, although the freezing and chilling facilities seem to be developed with the latest technology, the reality is not so. Most of them are functioning as a warehouse, that is, a storage function, and a considerable number of refrigerated warehouses are in a state of aging. Therefore, in this paper, the facility and function restructuring of the freezing storage warehouse have been set as a solution task, and the introduction of the cold chain system containing the latest smart technology has been proposed as a solution.

A Study on Refrigerate Warehouse Facility Performance Planning for Picking and Replenishing Facility Using Simulation Method (냉장창고설비의 픽킹 및 재 보충설비계획문제의 연구)

  • Hwang Heung Seok;Jo Gyu Seong;Choe Bae Seok
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.05a
    • /
    • pp.1035-1041
    • /
    • 2003
  • Recent studies among various activities taking place in order-picking warehouse system have shown various researches to reduce the order-picking costs occupying more than half the total costs. One way of improving the warehouse system performance is to separate from a picking area and a reserve area in one unit rack. This study is concerned on the performance evaluation model for picking and replenishing facility of refrigerated warehouse using simulation method. In this study, we developed a mathematical model to compute the system performance solve this problem using simulation method. We demonstrate the system performance using AutoMod Simulator and verify the results to compare mathematical results of the system performance of warehouse system. A systematic approach proposed n this study for an optimal planning of order-picking warehouse is known as an effective method for planning of order-picking warehouse and a performance evaluation problem considering both picking and replenishment.

  • PDF

A Study of Simulation on the Refrigerated Warehouse System Based on the Cold Energy of Lng Using the Pro-Ii Simulator (LNG 냉열을 이용한 냉장·냉동 창고 모사에 관한 연구)

  • HAN, DANBEE;KIM, YOONJI;YEOM, KYUIN;SHIN, JAERIN;BAEK, YOUNGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.401-406
    • /
    • 2017
  • When Liquified Natural Gas (LNG) is vaporized into NG for industrial and household usage, tremendous cold energy was transferred from LNG to seawater during phase-changing process. This heat exchanger loop is not only a waste of huge cold energy, but will cause thermal pollution to the coastal fishery area also when cold water was re-injected into the sea. In this study, an innovation design has been performed to reclaim the cold energy for -35 to $62^{\circ}C$ refrigerated warehouse. Conventionally, this was done by installing mechanical refrigeration systems, necessitating tremendous electrical power to drive temperature. A closed loop LNG heat exchangers in series was designed to replace the mechanical or vapor-compression refrigeration cycle by process simulator. The process simulation software of PRO II with provision has been used to simulate this process for various conditions, what to effect on cold energy and used energy for re-liquefaction and evaporation process. In addition, through analysis the effect of the change of LNG supply pressure on sensible and latent heat, optimum operational conditions was suggested for LNG cold energy warehouse.

Design and Implementation of a Mobile Framework for Efficient Inventory Management of Refrigerated Warehouses (효율적인 냉동창고 재고관리를 위한 모바일 프레임워크의 설계 및 구현)

  • Ban, ChaeHoon;Kim, DongHyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.341-346
    • /
    • 2013
  • Refrigerated warehouse inventory management program which manages the logistics of shipping&receiving and inventory quickly and accurately is a costly and labor-intensive maintenance because it is operated in the legacy system on a closed client-server environment. There are no services available for consignees who are the consumers of refrigerated warehouses except fax or phone for orders which makes the business process inefficient and creates many problems such as error and inaccuracy. In this paper, we design and implement a mobile framework with a legacy system supporting various services to the consignees for solving problems of outdated legacy systems and no services to use. The system supports promptness and accuracy which give the users improved satisfaction by providing orders and queries of inventory for the consignees on mobile devices.

Effect of the Array Type of Heat Exchangers on Performance of Refrigerated Warehouse for Utilization of LNG Cold Energy (LNG 냉열활용을 위한 열교환기의 배열 형태가 냉동창고 성능에 미치는 연구)

  • HAN, DANBEE;KIM, YUNJI;BYUN, HYUNSEUNG;BAEK, YOUNGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.282-288
    • /
    • 2019
  • When liquefied natural gas (LNG) is vaporized to form natural gas for industrial and household consumption, a tremendous amount of cold energy is transferred from LNG to seawater as a part of the phase-change process. This heat exchange loop is not only a waste of cold energy, but causes thermal pollution to coastal fishery areas by dumping the cold energy into the sea. This project describes an innovative new design for reclaiming cold energy for use by cold storage warehouses (operating in the 35 to $62^{\circ}C$ range). Conventionally, warehouse cooling is done by mechanical refrigeration systems that consume large amounts of electricity for the maintenance of low temperatures. Here, a closed loop LNG heat exchange system was designed (by simulator) to replace mechanical or vapor-compression refrigeration systems. The software PRO II with PROVISION V9.4 was used to simulate LNG cold energy, gas re-liquefaction, and the vaporized process under various conditions. The effects on sensible and latent heats from changes to the array type of heat exchangers have been investigated, as well as an examination of the optimum.

Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space (난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.