• Title/Summary/Keyword: reflection Loss

Search Result 437, Processing Time 0.028 seconds

Reflection and Transmission Coefficients by a Circular Pile Breakwater (원형 파일 방파제에 의한 반사율과 투과율)

  • Cho, Il-Hyoung;Koh, Hyeok-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.1
    • /
    • pp.38-44
    • /
    • 2007
  • Using the mathematical model suggested by Bennet et al.(1992), the reflection and transmission coefficients by a circular pile breakwater has been investigated in the framework of potential theory. Flow separation due to sudden contraction and expansion is generated and is the main cause of significant energy loss. Therefore, evaluation of exact energy loss coefficient is critical to enhance the reliability of mathematical model. To obtain the energy loss coefficient, 2-dimensional turbulent flow is analyzed using the FLUENT commercial code. The energy loss coefficient can be obtained from the pressure difference between upstream and downstream. Energy loss coefficient is the function of porosity and the relation equation between them is suggested throughout the curve fitting processing. To validated the suggested relation, comparison between the analytical results and the experimental results is made for four different porosities with good agreement.

Consideration of a structural-change point in the chain-ladder method

  • Kwon, Hyuk Sung;Vu, Uy Quoc
    • Communications for Statistical Applications and Methods
    • /
    • v.24 no.3
    • /
    • pp.211-226
    • /
    • 2017
  • The chain-ladder method, for which run-off data is employed is popularly used in the rate-adjustment and loss-reserving practices of non-life-insurance and health-insurance companies. The method is applicable when the underlying assumption of a consistent development pattern is in regards to a cumulative loss payment after the occurrence of an insurance event. In this study, a modified chain-ladder algorithm is proposed for when the assumption is considered to be only partially appropriate for the given run-off data. The concept of a structural-change point in the run-off data and its reflection in the estimation of unpaid loss amounts are discussed with numerical illustrations. Experience data from private health insurance coverage in Korea were analyzed based on the suggested method. The performance in estimation of loss reserve was also compared with traditional approaches. We present evidence in this paper that shows that a reflection of a structural-change point in the chain-ladder method can improve the risk management of the relevant insurance products. The suggested method is expected to be utilized easily in actuarial practice as the algorithm is straightforward.

Numerical Analysis of Loss Power Properties in the Near-Field Electromagnetic Wave Through A Microstrip Line for Multilayer Magnetic Films with Different Levels of Electrical Conductivity

  • Lee, Jung-Hwan;Kim, Sang-Woo
    • Journal of Magnetics
    • /
    • v.13 no.3
    • /
    • pp.92-96
    • /
    • 2008
  • There are few reports of high frequency loss behavior in the near-field for magnetic films with semiconducting properties, even though semiconducting magnetic materials, such as soft magnetic amorphous alloys and nanocrystalline thin films, have been demonstrated. The electromagnetic loss behavior of multilayer magnetic films with semiconducting properties on the microstrip line in quasi-microwave frequency band was analyzed numerically using a commercial finite-element based electromagnetic solver. The large increase in the absorption performance and broadband characteristics of the semiconducting/insulating layer magnetic films examined in this study were attributed to an increase in the loss factor of resistive loss. The electromagnetic reflection increased significantly with increasing conductivity, and the loss power deteriorated significantly. The numerical results of the magnetic field distribution showed that a strong radiated signal on the microstrip line was emitted with increasing conductivity and decreasing film thickness due to re-reflection of the radiated wave from the surface of the magnetic film, even though the emitted levels varied with film thickness.

Validity of Empirical Formulas for Estimation of Reflection Coefficient of Waves Due to Perforated Wall (유공벽에 의한 파의 반사율 산정에 있어서 경험공식의 타당성)

  • Yoon, Sung Bum;Lee, Jong In;Han, Sang Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.633-639
    • /
    • 2006
  • The validity of the existing formulas for the estimation of reflection coefficient of waves due to perforated wall is investigated using the result of hydraulic experiments conducted with perforated walls of various thickness. The result shows that, when the wall is thick, the energy loss coefficient is reduced to 62% of the value evaluated using the existing formula for sharp-crested orifice. The result also shows that the length of inertia resistance increases linearly as the thickness of the wall increases. The width of chamber to achieve the minimum reflection of waves decreases as the length of inertia resistance increases. Thus, the result found in the present study can be usful for the design of perforated wall.

A Study on the Reflection Type Analog Phase Shifter using Varactor and Branch Coupler (가변 캐패시터와 Branch Coupler를 이용한 반사형 아날로그 위상 변위기 연구)

  • 유강희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3A
    • /
    • pp.311-317
    • /
    • 2004
  • A low loss reflection type analog phase shifter which is realized with two varactors and branch coupler. is described. A new design technique for the large phase shift is applied using short stub microstripe lines. This paper presented the realization of design and experimental results. Through the experiment using the duroid microstrip line and varactors, the phase of 2.26GHz signal is controlled to the DC voltage with the phase shift range of 170$^{\circ}$. The achieved insertion loss of less than 3㏈ and the return loss of mote than 12㏈ are achieved over all phase states.

Wave Reflection from Porous Ocean Sediment With Depth Dependent Properties (깊이 방향의 변화가 있는 해저 퇴적물에서 반사 특성)

  • Lee, Keun-Hwa;Seong, Woo-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.1E
    • /
    • pp.1-7
    • /
    • 2006
  • This study examines the reflection characteristic of a thin transition layer of the ocean bottom showing variability with respect to depth. In order to model the surficial sediment simply, we reduce the Biot model to the depth dependent wave equation for the pseudo fluid using the fluid approximation (weak frame approximation). From the reduced equation, the difference between the inherent frequency dependency of the reflection and the frequency dependency resulting from a thin transition layer is investigated. Using Tang's depth porosity profile model of the surficial sediment [D. Tang et al., IEEE J. Oceanic Eng., vol.27(3), 546-560(2002)], we numerically simulated the reflection loss and investigated the contribution from both frequency dependencies. In addition, the effects of different sediment type and varying depth structure of the sediment are discussed.

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

Acoustic Characteristics of Wedge-shaped Anechoic Tiles with Different Wedge-apex Angles (꼭지각이 다른 쐐기형 무반향 타일의 음향특성)

  • 김성기;이강일;윤석왕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.5-11
    • /
    • 2001
  • Acoustic characteristics of the wedge-shaped anechoic tiles, used as absorbing lining materials for an anechoic water tank, were investigated for different wedge-apex angles. The anechoic tile base has the dimensions of 400mm x 385mm x 15.5mm. In order to investigate anechoic effect, the wedge-apex angles 30° and 60° were selected by using a ray-tracing method. The reflection loss of the anechoic tiles with and without wedges were experimentally studied at normal incident sound waves in water. In this experiment, the reflection loss of wedge-shaped anechoic tiles with the optimum wedge-apex angle 30° is larger than one with the angle 60° and one without wedges. The experimental results show that the wedge-shaped anechoic tiles with the wedge-apex angle 30°, optimized by using ray-tracing method, turn out better absorbing lining materials of an anechoic water tank.

  • PDF

Comparison & Analysis of Anti-Reflection Coatings for Crystalline Si Solar cells (결정질 실리콘 태양전지의 반사방지막 비교 분석)

  • Cho, Kyeong-Yeon;Lee, Ji-Hun;Lee, Soo-Hong;Lee, Kyu-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.221-222
    • /
    • 2008
  • In Crystalline Si solar cells, Anti-Reflection Coating is contribute to improvement in energy conversion efficiency due to decrease of optical loss and recombination owing to surface passivation. Porous Si is formed electrochemical etching that uses chemical solution and anodization etching. So It gives that advantage in rapid process time and without high cost equipment. In this paper, We compare Porous Si with $SiO_2$/SiNx ARC and analyze that by anti-reflection coating.

  • PDF

Reflection-Type 5-bit Digital Phase Shifter with Constant Insertion Loss (균일 삽입 손실 특성을 갖는 반사형의 5-비트 디지털 위상 변위기)

  • 고경석;최익권
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.6
    • /
    • pp.582-589
    • /
    • 2002
  • This paper presents 12.2 GHz ~ 12.7 GHz frequency band reflection type 5-bit digital phase shifter with constant insertion loss property that was fabricated with relatively low cost's InGaAs HEMT for amplifier. The unavoidable large insertion loss difference between on and off states of HEMT, when it is designed by conventional design theory based on ideal switching device, is removed by transforming the HEMT impedances at on and off states to other proper values connecting a certain length transmission line to HEMT and then applying the conventional design theory. The fabricated 5-bit digital phase shifter shows very good insertion loss properties of less than 1.5 dB insertion loss difference and -4.5 dB ~ -6 dB insertion loss in 35 phase steps at 12.2 GHz ~ 12.7 GHz. These results verify the design method presented in this paper, which is useful to design phase shifter of constant insertion loss with non-ideal switching device.