• 제목/요약/키워드: refinery wastewater

검색결과 17건 처리시간 0.025초

Industrial wastewater treatment by using of membrane

  • Razavi, Seyed Mohammad Reza;Miri, Taghi;Barati, Abolfazl;Nazemian, Mahboobeh;Sepasi, Mohammad
    • Membrane and Water Treatment
    • /
    • 제6권6호
    • /
    • pp.489-499
    • /
    • 2015
  • In this work, treatment of real hypersaline refinery wastewater by hollow fiber membrane bioreactor coupled with reverse osmosis unit was studied. The ability of HF-MBR and RO developed in this work, was evaluated through examination of the effluent properties under various operating conditions including hydraulic retention time and flux. Arak refinery wastewater was employed as influent of the bioreactor which consists of an immersed ultrafiltation membrane. The HF-MBR/RO was run for 6 months. Average elimination performance of chemical oxygen demand, biological oxygen demand, total suspended solids, volatile suspended solids, total dissolved soild and turbidity were obtained 82%, 89%, 98%, 99%, 99% and 98% respectively. Highly removal performance of oily contaminant, TDS and the complete retention of suspends solids implies good potential of the HF-MBR/RO system for wastewater refinement.

활성슬러지법에서 정유폐수처리의 동역학적 Simulation (A Dynamic Simulation for Refinery Wastewater in Activated Sludge Treatment)

  • 이우범;김종오
    • 대한환경공학회지
    • /
    • 제22권11호
    • /
    • pp.2017-2023
    • /
    • 2000
  • 정유폐수의 성상에 적합한 동역학적 모델을 적용하여 활성슬러지법으로 처리할 때 모델의 적합성을 검토하기 위하여 실제 정유폐수 처리장 포기조내의 환경인자의 변화와 유출수 특성을 비교하였다 활성슬러지 포기조내 DO, pH, MLSS, COD의 실제 측정값과 비교하였다. Simulation한 결과, 유출수 평균 COD가 19.0~19.4mg/L로 측정 COD 23.1mg/L와 잘 일치하였고, 포기조내 평균 DO는 1.9~2.4mg/L로 예측되었는데 측정된 평균 DO가 2.2mg/L로 잘 일치하여 모델의 정유폐수 처리장의 적용 가능성이 검토되었다.

  • PDF

Optimization of photo-catalytic degradation of oil refinery wastewater using Box-Behnken design

  • Tetteh, Emmanuel Kweinor;Naidoo, Dushen Bisetty;Rathilal, Sudesh
    • Environmental Engineering Research
    • /
    • 제24권4호
    • /
    • pp.711-717
    • /
    • 2019
  • The application of advanced oxidation for the treatment of oil refinery wastewater under UV radiation by using nanoparticles of titanium dioxide was investigated. Synthetic wastewater prepared from phenol crystals; Power Glide SAE40 motor vehicle oil and water was used. Response surface methodology (RSM) based on the Box-Behnken design was employed to design the experimental runs, optimize and study the interaction effects of the operating parameters including catalyst concentration, run time and airflow rate to maximize the degradation of oil (SOG) and phenol. The analysis of variance and the response models developed were used to evaluate the data obtained at a 95% confidence level. The use of the RSM demonstrated the graphical relationship that exists between individual factors and their interactive effects on the response, as compared to the one factor at time approach. The obtained optimum conditions of photocatalytic degradation are the catalyst concentration of 2 g/L, the run time of 30 min and the airflow rate of 1.04 L/min. Under the optimum conditions, a 68% desirability performance was obtained, representing 81% and 66% of SOG and phenol degradability, respectively. Thus, the hydrocarbon oils were readily degradable, while the phenols were more resistant to photocatalytic degradation.

Hydride Generation Atomic Absorption Spectrometry를 이용한 석유정제폐수중의 selenium 분석 (Analysis of selenium in oil refinery wastewater by hydride generation atomic absorption spectrometry)

  • 천미희;김철;이현주;강임석
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.399-406
    • /
    • 2003
  • 본 연구는 수소화물 발생장치가 부착된 원자흡광 광도계 (HG-AAS)를 이용하여 비교적 고농도의 Se을 함유하고 있는 석유정제 폐수의 Se 분석을 위하여 적합한 분석조건을 선정하고자 수행되었다. Se(VI)의 Se(IV)로의 환원 실험에서 폐수량 10 mL, 염산 주입량 10 mL, 가열시간 30분이 최적 환원조건으로 결정되었다. 폐수의 조성성분과 유기물의 농도가 높은 경우에는 Se 회수율이 감소하였다. 따라서 3가지 산분해법 ($HNO_3/HClO_4$ 분해, $KMnO_4$ 분해 및 초단파 산분해)에 의한 유기물, 석유화합물 분해 및 유기성 Se(org.), Se(IV) 산화에 따른 Se 회수율을 검토하였다. 실험결과 산분해전 약 50~80%이었던 Se 회수율은 모든 산분해에서 90%이상이었으며 특히, 초단파 산분해에 의한 Se 회수율이 가장 높은 것으로 나타났다. 그러므로 HG-AAS를 이용한 석유정제 폐수의 Se 분석시에는 초단파 산분해후 염산 처리를 하는 전처리 과정이 가장 적합한 것으로 나타났다.

정유 공장에서 발생된 폐수 슬러지의 최적 감량화 방안 연구 (Study of optimal reduction plan for wastewater sludge generated from oil refinery)

  • 최재우;정종민;심나탈리아;이상협;박철희
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.395-406
    • /
    • 2010
  • In this study, anaerobic digestion, electro-oxidation and electro-fenton oxidation processes were investigated to reduce oily refinery sludge. Anaerobic digestion process was not suitable for oily activated sludge reduction because of characteristics itself and, as experimental results revealed, reduction efficiency was low for electro-oxidation process. However, 40% total suspended solid reduction of oily activated sludge was obtained by electro-fenton oxidation process, operating at pH=1, 0.5 A and $Fe^{2+}$:$H_2O_2$ ratio = 1:30. In addition, higher reduction efficiency was obtained as reaction time was increased (30, 60, 90, 120 min) despite of low $H_2O_2$ concentration. From the results, it has been investigated that electro-fenton oxidation is efficient process for oily activated sludge reduction.

광양만 백합양식장 수질에 미치는 영향에 대하여 (WATER QUALITY OF THE CULTURE BEDS OF HARD CLAM AND ADJACENT SEA OF THE Y대녀 REFINERY OF HONAM OIL REFINERY CO. IN KWANG YANG BAY)

  • 원종훈;고남표
    • 한국수산과학회지
    • /
    • 제8권2호
    • /
    • pp.73-84
    • /
    • 1975
  • 1) 호남정유공장 폐수 및 부근에 버려진 유류와 사포리의 원유저장 탱크에서 흘러나온 유류는 썰물을 따라 여수해만 쪽으로 흘렸다가 밀물을 따라 백합양식장으로 바로 흘러 들어가며 대조일의 조수에서 $6\~8 $시간만에 양식장 전역에 이른다. 2) 지점 9, 10은 강수의 혼입이 약간 많은 수질인 즉 pH가 상대적으로 낮고 암모니아 질소가 많고 n-헥산 가용물질량이 적은 편이지만 지점 $6\~10$은 수질이 동일하다. 3) 폐수배출관이 있는 지점 2에서의 수질은 표층, 중층, 하층에 별다른 차가 없다. 4) 호남정유공장 폐수에 있어서 유해성분으로서 pH, 황화물이 배출기준 보다 높고, COD, 페놀, n-확산 가용물질량은 배출 기준보다 낮은 편이나 n-헥산가용물질량은 상당히 높은 수준이라고 본다. 5) 호남정유공장 폐수에 함유되어 있는 유해성분의 각 수역에서의 농도는 n-확산가용성 이외는 정상해수와 별로 다른 바 없다. 그러나 n-확산가용물질의 농도는 정상해수보다 높다. 6)해역에서의 n-헥산가용물질량 및 COD 값이 Table 1에서 볼 때 공장에 가까운 수역일수록 높은 것으로 보아 백합양식장에서의 이들 성분농도가 높은 원인은 해구유동도 참작할 때 호남정유공장의 폐수 및 누출유에 있다고 본다.

  • PDF

산업폐수 관리체계 개선을 위한 수질오염물질 배출목록 구축에 대한 연구: 1차 철강 제조업과 석유정제품 제조업 (A Study on the Water Pollutant Discharge Inventories for the Improvement of Industrial Wastewater Management System: Primary Steel Manufacturing Facility and Petroleum Refining Products Manufacturing Facility)

  • 안태웅;김동민;손대희;김재훈
    • 한국물환경학회지
    • /
    • 제36권5호
    • /
    • pp.453-467
    • /
    • 2020
  • This study aimed to inventory the water pollutant discharge of wastewater from two facilities, one primary steel manufacturing facility and one petroleum refinery, both of which are located in Korea, and to identify ways to improve the wastewater treatment process through field investigation. Probability evaluation was used to inventory the substances in polluted water. The samples collected in this study included original wastewater, on processing wastewater, and treated water. The general description of wastewater occurrence, major sources, and treatment facilities were also investigated to obtain an integrated database of the pollutants created by different industrial categories. Based on our analysis of raw wastewater and final effluent, the detected pollutants were confirmed by analyzing their presence in the raw or supplemental materials, the potential of formation as byproducts, and the possibility of inclusion as impurities. The compounds detected for each category were screened via investigation of their possible sources and confirmed as the final water pollutant inventories. Thirty kinds of water pollutants were emitted by the primary steel manufacturing facility (reference in case A), including 14 specified hazardous water pollutants. The petroleum refinery (reference in case B) emitted 36 water pollutants, including 16 specified hazardous water pollutants.

UF/RO 공정을 이용한 정유공장 방류수의 재활용을 위한 고도처리 (Advanced Treatment for Reuse of Oil Refinery Process Wastewater using UF/RO Processes)

  • 이광현
    • 멤브레인
    • /
    • 제10권4호
    • /
    • pp.220-229
    • /
    • 2000
  • 본 연구는 한외여과 중공사형 모듈과 역삼투 나권형 모듈로 구성된 모듈 set 1∼7을 이용하여 모듈 set에 따른 순수 및 2차 처리수의 투과 flux를 고찰하고, 적용압력과 온도변화에 의한 한외여과 막과 역삼투 막의 분리 특성을 고찰하였다. 탁도와 SS는 한외여과 막에서 효율적으로 제거되며 COD, T-N, TDS 등은 역삼투 막에서 우수한 제거효율을 나타내었다. 적용압력과 온도의 증가에 따른 투과 flux는 선형적으로 증가하는 경향을 보였다. 이로부터 한외여과 및 역삼투 막은 정유공장 방류수의 고도처리 및 재활용을 위해 적합한 것으로 나타났다.

  • PDF

역삼투막을 이용한 정유산업 폐수 재활용 연구 (Reuse of Petroleum Refinery Wastewater Using Reverse Osmosis Membrane)

  • 황종식;상병인;유제강;이규현;민병렬;김병식
    • 멤브레인
    • /
    • 제4권4호
    • /
    • pp.213-220
    • /
    • 1994
  • 정유산업 방출폐수를 재처리하여 양질의 공업용수로 활용하고자 역삼투막 및 공정으로 구성된 재활용 system을 고안하여 현장 pilot 실험을 수행하였다. 생산공정 운전상황에 따라 불규칙적으로 변하는 폐수 특성에도 불구하고 역삼투막의 경우 10~15$kg/cm^2$의 운전압력 범위내에서 96~99%정도의 비교적 높은 염배제율을 보였으며 본 실험을 통하여 얻은 재생수의 경우 냉각탑 공급용수로써의 충분한 가능성을 보여 주었다. 그러나 본 연구에서 제안 사용된 여과형 전처리 공정만으로는 충분한 처리효율을 기대하기 어려웠으며, 이는 각 여과공정법 처리수의 수질분석 결과 및 NaOH를 이용한 역삼투막 세정 결과로부터 쉽게 확인되었다.

  • PDF