• Title/Summary/Keyword: reference surfaces

Search Result 143, Processing Time 0.024 seconds

Development of 3D statistical mandible models for cephalometric measurements

  • Kim, Sung-Goo;Yi, Won-Jin;Hwang, Soon-Jung;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Hong, Helen;Yoo, Ji-Hyun
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.175-182
    • /
    • 2012
  • Purpose: The aim of this study was to provide sex-matched three-dimensional (3D) statistical shape models of the mandible, which would provide cephalometric parameters for 3D treatment planning and cephalometric measurements in orthognathic surgery. Materials and Methods: The subjects used to create the 3D shape models of the mandible included 23 males and 23 females. The mandibles were segmented semi-automatically from 3D facial CT images. Each individual mandible shape was reconstructed as a 3D surface model, which was parameterized to establish correspondence between different individual surfaces. The principal component analysis (PCA) applied to all mandible shapes produced a mean model and characteristic models of variation. The cephalometric parameters were measured directly from the mean models to evaluate the 3D shape models. The means of the measured parameters were compared with those from other conventional studies. The male and female 3D statistical mean models were developed from 23 individual mandibles, respectively. Results: The male and female characteristic shapes of variation produced by PCA showed a large variability included in the individual mandibles. The cephalometric measurements from the developed models were very close to those from some conventional studies. Conclusion: We described the construction of 3D mandibular shape models and presented the application of the 3D mandibular template in cephalometric measurements. Optimal reference models determined from variations produced by PCA could be used for craniofacial patients with various types of skeletal shape.

A comparative study of periodontal conditions around mesially tipped molars by a tipping degree (대구치의 근심 경사 정도에 따른 치주 상태의 비교 연구)

  • Park, So-Young;Choi, Seoung-Hwan;Lee, Su-Jeong;Chang, Moon-Taek;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.41-49
    • /
    • 2002
  • The aim of this study was to compare periodontal conditions around mesially tipped molars by a tipping degree. Patients who had been consecutively treated at the Department of Periodontology, Chonbuk National University Hospital from October 1999 to August 2001 were assessed with radiographs taken at their molar regions. Of all molars investigated, 142 molars of 116 patients tipped mesially more than 10 degrees to the line perpendicular to an occlusal plane were selected for the study. The tipped molars were divided into 2 groups with a reference to a tipping degree, i.e., 66 slightly tipped(group 1 : <$30^{\circ}$) and 76 severely tipped molars (group 2 : ${\geq}30^{\circ}$). Probing depth(PD), plaque retention index(PRI) at mesial surfaces of tipped molars and tooth mobility(TM) were recorded at the clinical examination. Tipping degree(TD) and alveolar bony defect(ABD) at the mesial surface of the molars were measured in a radiograph. The results showed that no statistical differences were found between groups in all measured variables. In Pearson correlation analysis performed in the same group, a positive relationship was shown between PRI and PD in the group 1 and, in the group 2, between PRI and PD as well as PRI and ABD(p < 0.01). However, no statistically significant relationship was found between TD and all other variables in both groups. Within limitations of this study, it may be concluded that tipping degree did not seem to influence periodontal conditions, i.e., PD, ABD and TM of mesially tipped molars per se, but plaque presence/absence seemed to mainly affect the periodontal conditions of the tipped molars.

Fully Automated Generation of Cloud-free Imagery Using Landsat-8 (Landsat-8을 이용한 자동화된 구름 제거 영상 생성)

  • Kim, Byeong Hee;Kim, Yong;Han, You Kyung;Choi, Won Seok;Kim, Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.2
    • /
    • pp.133-142
    • /
    • 2014
  • Landsat is one of the popular satellites for observing land surface that is used in various areas including monitoring, detecting and classifying changes in land surface. However, shades, which cloud itself and its shadow, interrupted often clear observation and analysis of ground surface. For this reason, the process of removing shades and restoring original ground surfaces are critical for geospatial users. This study is planned to recommend a methodology for more accurate and clear images of Landsat-8 sensor, which provided two additional bands of costal/aerosol and cirrus. In fact, those bands are known as functioned effectively in detecting and restoring shades. Otsu's thresholding technique to detect clouds, we replaced those detective shades by using experimental and reference images. In accurate assessment, the overall accuracy and kappa coefficients were about 85% and 0.7128, respectively. This indicates that the proposed technique is effective for recovering the original land surface.

EFFECTS OF SURFACE ROUGHNESS AND MULTILAYER COATING ON THE CORROSION RESISTANCE OF Ti-6Al-4V ALLOY

  • Ko, Yeong-Mu;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.134-135
    • /
    • 2003
  • The dental implant materials required good mechanical properties, such as fatigue strength, combined with a high resistance to corrosion. For increasing fatigue resistance and delaying onset of stress corrosion cracking, shot peening has been used for > 50 years to extend service life of metal components. However, there is no information on the electrochemical behavior of shot peened and hydroxyapatite(HA) coated Ti-6Al-4V alloys. To increase fatigue strength, good corrosion resistance, and biocompatibility, the electrochemical characteristics of Ti/TiN/HA coated and shot peened Ti-6Al-4V alloys by electron beam physical vapor deposition(EB-PVD) have been researched by various electrochemical method in 0.9%NaCl. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. The produced materials were quenched at 1000$^{\circ}C$ under high purity dried Ar atmosphere and were hold at 500$^{\circ}C$ for 2 hrs to achieve the fatigue strength(1140㎫) of materials. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. Shot peening(SP) and sand blasting treatment was carried out for 1, 5, and 10min. On the surface of Ti-6Al-4V alloys using the steel balls of 0.5mm and alumina sand of 40$\mu\textrm{m}$ size. Ti/TiN/HA multilayer coatings were carried out by using electron-beam deposition method(EB-PVD) as shown Fig. 1. Bulk Ti, powder TiN and hydroxyapatite were used as the source of the deposition materials. Electrons were accelerated by high voltage of 4.2kV with 80 - 120mA on the deposition materials at 350$^{\circ}C$ in 2.0 X 10-6 torr vacuum. Ti/TiN/HA multilayer coated surfaces and layers were investigated by SEM and XRD. A saturated calomel electrode as a reference electrode, and high density carbon electrode as a counter electrode, were set according to ASTM GS-87. The potentials were controlled at a scan rate of 100 mV/min. by a potentiostat (EG&G Co.273A) connected to a computer system. Electrochemical tests were used to investigate the electrochemical characteristics of Ti/TiN/HA coated and shot peened materials in 0.9% NaCl solution at 36.5$^{\circ}C$. After each electrochemical measurement, the corrosion surface of each sample was investigated by SEM.

  • PDF

Biocompatibility of experimental mixture of mineral trioxide aggregate and glass ionomer cement (Glass ionomer cement와 혼합한 mineral trioxide aggregate의 생체친화성)

  • Oh, Min-Jae;Jeong, Yu-Na;Bae, In-Ho;Yang, So-Young;Park, Bum-Jun;Koh, Jeong-Tae;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.359-367
    • /
    • 2010
  • Objectives: The purpose of the present in vitro study was to evaluate the biocompatibility of mineral trioxide aggregate (MTA) mixed with glass ionomer cement (GIC), and to compare it with that of MTA, GIC, IRM and SuperEBA. Materials and Methods: Experimental groups were divided into 3 groups such as 1 : 1, 2 : 1, and 1 : 2 groups depending on the mixing ratios of MTA powder and GIC powder. Instead of distilled water, GIC liquid was mixed with the powder. This study was carried out using MG-63 cells derived from human osteosarcoma. They were incubated for 1 day on the surfaces of disc samples and examined by scanning electron microscopy. To evaluate the cytotoxicity of test materials quantitatively, XTT assay was used. The cells were exposed to the extracts and incubated. Cell viability was recorded by measuring the optical density of each test well in reference to controls. Results: The SEM revealed that elongated, dense, and almost confluent cells were observed in the cultures of MTA mixed with GIC, MTA and GIC. On the contrary, cells on the surface of IRM or SuperEBA were round in shape. In XTT assay, cell viability of MTA mixed with GIC group was similar to that of MTA or GIC at all time points. IRM and SuperEBA showed significantly lower cell viability than other groups at all time points (p < 0.05). Conclusions: In this research MTA mixed with GIC showed similar cellular responses as MTA and GIC. It suggests that MTA mixed with GIC has good biocompatibility like MTA and GIC.

Ultrastructural studies on the surface of Puragonimus westermani metacercaria (폐흡충 피낭유충 표피의 형태학적 관찰)

  • Kim, Gyeong-Min;An, Myeong-Hui;Min, Deuk-Yeong
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.2
    • /
    • pp.129-140
    • /
    • 1987
  • The present study was undertaken to demonstrate the surface structure of Paragonimus westermani metacercaria in Korea with special reference to the distribution of sensory papillae. Metacercariae were isolated from crayfish, one of the second intermediate tost of P. westermani in Bogil island, Chollanam-do (Province), Korea, where has been known as an endemic area of human paragonimiasis. Isolated metacercariae were encysted and examined with light. scanning and transmission electron microscopes for morphological features. On the surface of iBetacercariae, three types of sensory FaFillae were identified. Large domed papillae ($3~5{\mu\textrm{m}}$), which were covered with wrinkled plasma n!embrane of the worm, were distributed on the oral and ventral suckers only. On the oral sucker, these large domed papillae were 12~13 in number. On the other hand large domed papillae on the ventral sucker were constantly 6 in number and hexagonal in distribution. Small domed papillae ($2~3{\mu\textrm{m}}$), of which surface was more smooth than those of large ones, were distributed symmetrically on the ventral (30~32 pairs) and dorsal surfaces (40~42 Pairs). Ciliated Papillae ($0.8~1.5{\mu\textrm{m}}$) were observed about 5~6 in number around the oral sucker and 3~5 pairs each on the ventral and dorsal surface of the body. Single Fcinted spines covered the entire surface of the body except around the excretory pore. Spines on the anterior fart of the body were 0.9~2.0${\mu\textrm{m}}$ in length and $45~55/100{\mu\textrm{m}}$2 in number, and were gradually reduced in length ($0.4~1.4{\mu\textrm{m}}$) and in nuns.her ($12~27/100{\mu\textrm{m}}$2) toward the posterior part. The body wall of p. westermoni metacercariae was consisted with anucleated syncytium layer, fibrous interstitial layer and musclar layer. In the anucleated syncytium, biconcave ($0.15~0.55{\mu\textrm{m}}$) and spherical ($0.08~0.16{\mu\textrm{m}}$) secretory granules, which were transferred from epidermal cells via protoplasmic tubules, mitochondria and rihoEorses, T-ere observed. Spines originated around the basement membrane protruded externally. Epidermal cells were consisted with a nucleus and a cytoplasm, and connected to syncytium with protoplasmic tubules. In the cytoplasm many secretory granules, mitochondria, Golgi complex, endoplasmic reticula, ribosomes and lipid droplets were observed.

  • PDF

Descent Dataset Generation and Landmark Extraction for Terrain Relative Navigation on Mars (화성 지형상대항법을 위한 하강 데이터셋 생성과 랜드마크 추출 방법)

  • Kim, Jae-In
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1015-1023
    • /
    • 2022
  • The Entry-Descent-Landing process of a lander involves many environmental and technical challenges. To solve these problems, recently, terrestrial relative navigation (TRN) technology has been essential for landers. TRN is a technology for estimating the position and attitude of a lander by comparing Inertial Measurement Unit (IMU) data and image data collected from a descending lander with pre-built reference data. In this paper, we present a method for generating descent dataset and extracting landmarks, which are key elements for developing TRN technologies to be used on Mars. The proposed method generates IMU data of a descending lander using a simulated Mars landing trajectory and generates descent images from high-resolution ortho-map and digital elevation map through a ray tracing technique. Landmark extraction is performed by an area-based extraction method due to the low-textured surfaces on Mars. In addition, search area reduction is carried out to improve matching accuracy and speed. The performance evaluation result for the descent dataset generation method showed that the proposed method can generate images that satisfy the imaging geometry. The performance evaluation result for the landmark extraction method showed that the proposed method ensures several meters of positioning accuracy while ensuring processing speed as fast as the feature-based methods.

A Study on Position Correction Sign for Autonomous Driving Vehicles (자율주행 자동차를 위한 측위 보정 표지 연구)

  • Young-Jae JEON;Chul-Woo PARK;Sang-Yeon WON;Jun-Hyuk LEE
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.4
    • /
    • pp.161-172
    • /
    • 2023
  • Autonomous driving vehicles recognize the surroundings through various sensors mounted on the vehicle and control the vehicle based on the collected information. The level of autonomous driving technology is improving due to the development of sensor technology and algorithms that process collected data, but the implementation of perfect autonomous driving technology has not been achieved. To overcome these limitations, through autonomous cooperative driving centered on infrastructure. In this study, developed a position correction sign that provides a reference for positioning of autonomous vehicles. First of all, an analysis was performed on the current status of positioning technology for autonomous driving. And measure the number of point clouds for the 1st sample consisting of two square reflective surfaces and 2nd sample that increased the vertical length of each reflective surface. Experimental results show that both primary and secondary products are installed at least 15 m apart It could be recognized as a sensor, and it was confirmed that the secondary production that increased the length of the top and bottom had a higher number of point clouds than the primary production and better expressed the shape of the facility.

A Study on the labial & buccal surface contour in Korean permanent teeth using three-dimensional laser scanning (3차원 레이저 스캐너를 이용한 한국인 영구치의 순, 협측 치관 굴곡도에 관한 연구)

  • Ko, Sang-Duck;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.32 no.4 s.93
    • /
    • pp.275-291
    • /
    • 2002
  • Of various factors indicated for effective use of straight wire appliances, there was a great lack of studies both domestic and international about the curvatures of tooth crowns. This study was performed to investigate the labio/buccal clinical crown curvatures of Korean permanent teeth. For this study, three-dimensional laser scanning was performed on 36 dental casts with normal anatomic structures. Andrews plane and Facial axis of clinical crown (FACC) were designated as horizontal and vertical reference planes respectively. 2 or 3 lines, 1mm apart, were drawn superior, inferior, left and right of these reference planes. A three-dimensional coordinate table was made for points formed by crossing these lines, and averages of each coordinate point on the 36 dental casts were obtained. The curvature equation was made using three-dimensional coordinate points (x,y,z) and by this curvature equation, the curve ratio of each tooth was obtained. Curve ratio changes of each section of teeth were calculated by curve ratios of simplified curves. These two dimensional curves were simplified horizontally and vertically Conclusions for this study are as follows. 1. The basic data of labial and buccal clinical crown curvatures were obtained about Korean permanent teeth. 2. No significant difference was found between male and females. 3. Individual tooth characteristics 1) In maxillary central incisors, the difference in the curve ratio between the gingival and incisal sides was greater than for the other teeth. And the gingival side showed a greater curve ratio. 2) Maxillary canines showed more curvatures in the mesio-occlusal surface than the other surfaces. 3) In maxillary $1^{st}$ premolars, more curvatures were found in mesio-occlusal and disto-gingival surface, thus showing a twisted crown surface, but in maxillary $2^{nd}$ premolars, the crown curvatures of mesial and distal ends became parallel to each other. 4) No significant difference in crown curvatures was found between mandibular central and lateral incisors. 5) Occluso-gingival curvatures of mandibular$2^{nd}$ premolar turned out to be more rounded than mandibular $1^{st}$ premolars or maxillary $2^{nd}$ premolars. From the above conclusions, it can be deduced that the same bracket bases can be used for mandibular central and lateral incisors. But for maxillary $1^{st}\;and\;2^{nd}$ premolars and for mandibular $1^{st}\;and\;2^{nd}$ premolars, because crown curvatures showed significant differences, when making bracket bases there is ample reason to make bracket base curves differently for each type of tooth.

A Polarization-based Frequency Scanning Interferometer and the Measurement Processing Acceleration based on Parallel Programing (편광 기반 주파수 스캐닝 간섭 시스템 및 병렬 프로그래밍 기반 측정 고속화)

  • Lee, Seung Hyun;Kim, Min Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.253-263
    • /
    • 2013
  • Frequency Scanning Interferometry(FSI) system, one of the most promising optical surface measurement techniques, generally results in superior optical performance comparing with other 3-dimensional measuring methods as its hardware structure is fixed in operation and only the light frequency is scanned in a specific spectral band without vertical scanning of the target surface or the objective lens. FSI system collects a set of images of interference fringe by changing the frequency of light source. After that, it transforms intensity data of acquired image into frequency information, and calculates the height profile of target objects with the help of frequency analysis based on Fast Fourier Transform(FFT). However, it still suffers from optical noise on target surfaces and relatively long processing time due to the number of images acquired in frequency scanning phase. 1) a Polarization-based Frequency Scanning Interferometry(PFSI) is proposed for optical noise robustness. It consists of tunable laser for light source, ${\lambda}/4$ plate in front of reference mirror, ${\lambda}/4$ plate in front of target object, polarizing beam splitter, polarizer in front of image sensor, polarizer in front of the fiber coupled light source, ${\lambda}/2$ plate between PBS and polarizer of the light source. Using the proposed system, we can solve the problem of fringe image with low contrast by using polarization technique. Also, we can control light distribution of object beam and reference beam. 2) the signal processing acceleration method is proposed for PFSI, based on parallel processing architecture, which consists of parallel processing hardware and software such as Graphic Processing Unit(GPU) and Compute Unified Device Architecture(CUDA). As a result, the processing time reaches into tact time level of real-time processing. Finally, the proposed system is evaluated in terms of accuracy and processing speed through a series of experiment and the obtained results show the effectiveness of the proposed system and method.