• Title/Summary/Keyword: reference standard

Search Result 2,153, Processing Time 0.024 seconds

The Value of Adding Ductography to Ultrasonography for the Evaluation of Pathologic Nipple Discharge in Women with Negative Mammography

  • Younjung Choi;Sun Mi Kim;Mijung Jang;Bo La Yun;Eunyoung Kang;Eun-Kyu Kim;So Yeon Park;Bohyoung Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.866-877
    • /
    • 2022
  • Objective: The optimal imaging approach for evaluating pathological nipple discharge remains unclear. We investigated the value of adding ductography to ultrasound (US) for evaluating pathologic nipple discharge in patients with negative mammography findings. Materials and Methods: From July 2003 to December 2018, 101 women (mean age, 46.3 ± 12.2 years; range, 23-75 years) with pathologic nipple discharge were evaluated using pre-ductography (initial) US, ductography, and post-ductography US. The imaging findings were reviewed retrospectively. The standard reference was surgery (70 patients) or > 2 years of follow-up with US (31 patients). The diagnostic performances of initial US, ductography, and post-ductography US for detecting malignancy were compared using the McNemar's test or a generalized estimating equation. Results: In total, 47 papillomas, 30 other benign lesions, seven high-risk lesions, and 17 malignant lesions were identified as underlying causes of pathologic nipple discharge. Only eight of the 17 malignancies were detected on the initial US, while the remaining nine malignancies were detected by ductography. Among the nine malignancies detected by ductography, eight were detected on post-ductography US and could be localized for US-guided intervention. The sensitivities of ductography (94.1% [16/17]) and post-ductography US (94.1% [16/17]) were significantly higher than those of initial US (47.1% [8/17]; p = 0.027 and 0.013, respectively). The negative predictive value of post-ductography US (96.9% [31/32]) was significantly higher than that of the initial US (83.3% [45/54]; p = 0.006). Specificity was significantly higher for initial US than for ductography and post-ductography US (p = 0.001 for all). Conclusion: The combined use of ductography and US has a high sensitivity for detecting malignancy in patients with pathologic nipple discharge and negative mammography. Ductography findings enable lesion localization on second-look post-ductography US, thus facilitating the selection of optimal treatment plans.

Diagnostic Performance of Core Needle Biopsy for Characterizing Thyroidectomy Bed Lesions

  • So Yeong Jeong;Jung Hwan Baek;Sae Rom Chung;Young Jun Choi;Dong Eun Song;Ki-Wook Chung;Won Woong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.1019-1027
    • /
    • 2022
  • Objective: Thyroidectomy bed lesions frequently show suspicious ultrasound (US) features after thyroid surgery. Fine-needle aspiration (FNA) may not provide definitive pathological information about the lesions. Although core-needle biopsy (CNB) has excellent diagnostic performance in characterizing suspicious thyroid nodules, no published studies have evaluated the performance of CNB specifically for thyroidectomy bed lesions. Therefore, we aimed to evaluate the diagnostic performance and safety of CNB for characterizing thyroidectomy bed lesions. Materials and Methods: A total of 124 thyroidectomy bed lesions in 113 patients (79 female and 34 male; age, 23-85 years) who underwent US-guided CNB between December 2008 and December 2020 were included. We reviewed the US imaging features of the target lesions and the histories of previous biopsies. The pathologic results, diagnostic performance for malignancy, and complications of CNB were analyzed. Results: All samples (100%) obtained by CNB were adequate for pathological analysis. Pathological analysis revealed inconclusive results in two lesions (1.6%). According to the reference standard, 50 lesions were ultimately malignant (40.3%), and 72 were benign (58.1%), excluding the two inconclusive lesions. The performance of CNB for diagnosing malignant thyroidectomy bed lesions in the 122 lesions had a sensitivity of 98.0% (49/50), a specificity of 100% (72/72), positive predictive value of 100% (49/49), and negative predictive value of 98.6% (72/73). Eleven lesions were referred for CNB after prior inconclusive FNA results in thyroidectomy bed lesions, for all of which CNB yielded correct conclusive pathologic diagnoses. According to the pathological analysis of CNB, there were various benign lesions (58.9%, 73/124) besides recurrence, including benign postoperative lesions other than suture granuloma (32.3%, 40/124), suture granuloma (15.3%, 19/124), remnant thyroid tissue (5.6%, 7/124), parathyroid lesions (4%, 5/124), and abscesses (1.6%, 2/124). No major or minor complications were associated with the CNB procedure. Conclusion: US-guided CNB is accurate and safe for characterizing thyroidectomy bed lesions.

Diagnostic Performance of Spin-Echo Echo-Planar Imaging Magnetic Resonance Elastography in 3T System for Noninvasive Assessment of Hepatic Fibrosis

  • Se Woo Kim;Jeong Min Lee;Sungeun Park;Ijin Joo;Jeong Hee Yoon;Won Chang;Haeryoung Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.180-188
    • /
    • 2022
  • Objective: To validate the performance of 3T spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) for staging hepatic fibrosis in a large population, using surgical specimens as the reference standard. Materials and Methods: This retrospective study initially included 310 adults (155 undergoing hepatic resection and 155 undergoing donor hepatectomy) with histopathologic results from surgical liver specimens. They underwent 3T SE-EPI MRE ≤ 3 months prior to surgery. Demographic findings, underlying liver disease, and hepatic fibrosis pathologic stage according to METAVIR were recorded. Liver stiffness (LS) was measured by two radiologists, and inter-reader reproducibility was evaluated using the intraclass correlation coefficient (ICC). The mean LS of each fibrosis stage (F0-F4) was calculated in total and for each etiologic subgroup. Comparisons among subgroups were performed using the Kruskal-Wallis test and Conover post-hoc test. The cutoff values for fibrosis staging were estimated using receiver operating characteristic (ROC) curve analysis. Results: Inter-reader reproducibility was excellent (ICC, 0.98; 95% confidence interval, 0.97-0.99). The mean LS values were 1.91, 2.41, 3.24, and 5.41 kPa in F0-F1 (n = 171), F2 (n = 26), F3 (n = 38), and F4 (n = 72), respectively. The discriminating cutoff values for diagnosing ≥ F2, ≥ F3, and F4 were 2.18, 2.71, and 3.15 kPa, respectively, with the ROC curve areas of 0.97-0.98 (sensitivity 91.2%-95.9%, specificity 90.7%-99.0%). The mean LS was significantly higher in patients with cirrhosis (F4) of nonviral causes, such as primary biliary cirrhosis (9.56 kPa) and alcoholic liver disease (7.17 kPa) than in those with hepatitis B or C cirrhosis (4.28 and 4.92 kPa, respectively). There were no statistically significant differences in LS among the different etiologic subgroups in the F0-F3 stages. Conclusion: The 3T SE-EPI MRE demonstrated high interobserver reproducibility, and our criteria for staging hepatic fibrosis showed high diagnostic performance. LS was significantly higher in patients with non-viral cirrhosis than in those with viral cirrhosis.

Comparison Between Contrast-Enhanced Computed Tomography and Contrast-Enhanced Magnetic Resonance Imaging With Magnetic Resonance Cholangiopancreatography for Resectability Assessment in Extrahepatic Cholangiocarcinoma

  • Jeongin Yoo;Jeong Min Lee;Hyo-Jin Kang;Jae Seok Bae;Sun Kyung Jeon;Jeong Hee Yoon
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.983-995
    • /
    • 2023
  • Objective: To compare the diagnostic performance and interobserver agreement between contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CE-MRI) with magnetic resonance cholangiopancreatography (MRCP) for evaluating the resectability in patients with extrahepatic cholangiocarcinoma (eCCA). Materials and Methods: This retrospective study included treatment-naïve patients with pathologically confirmed eCCA, who underwent both CECT and CE-MRI with MRCP using extracellular contrast media between January 2015 and December 2020. Among the 214 patients (146 males; mean age ± standard deviation, 68 ± 9 years) included, 121 (56.5%) had perihilar cholangiocarcinoma. R0 resection was achieved in 108 of the 153 (70.6%) patients who underwent curative-intent surgery. Four fellowship-trained radiologists independently reviewed the findings of both CECT and CE-MRI with MRCP to assess the local tumor extent and distant metastasis for determining resectability. The pooled area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of CECT and CE-MRI with MRCP were compared using clinical, surgical, and pathological findings as reference standards. The interobserver agreement of resectability was evaluated using Fleiss kappa (κ). Results: No significant differences were observed between CECT and CE-MRI with MRCP in the pooled AUC (0.753 vs. 0.767), sensitivity (84.7% [366/432] vs. 90.3% [390/432]), and specificity (52.6% [223/424] vs. 51.4% [218/424]) (P > 0.05 for all). The AUC for determining resectability was higher when CECT and CE-MRI with MRCP were reviewed together than when CECT was reviewed alone in patients with discrepancies between the imaging modalities or with indeterminate resectability (0.798 [0.754-0.841] vs. 0.753 [0.697-0.808], P = 0.014). The interobserver agreement for overall resectability was fair for both CECT (κ = 0.323) and CE-MRI with MRCP (κ = 0.320), without a significant difference (P = 0.884). Conclusion: CECT and CE-MRI with MRCP showed no significant differences in the diagnostic performance and interobserver agreement in determining the resectability in patients with eCCA.

Is the Mixed Use of Magnetic Resonance Enterography and Computed Tomography Enterography Adequate for Routine Periodic Follow-Up of Bowel Inflammation in Patients with Crohn's Disease?

  • Jiyeon Ha;Seong Ho Park;Jung Hee Son;Ji Hun Kang;Byong Duk Ye;So Hyun Park;Bohyun Kim;Sang Hyun Choi;Sang Hyoung Park;Suk-Kyun Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.30-41
    • /
    • 2022
  • Objective: Computed tomography enterography (CTE) and magnetic resonance enterography (MRE) are considered substitutes for each other for evaluating Crohn's disease (CD). However, the adequacy of mixing them for routine periodic follow-up for CD has not been established. This study aimed to compare MRE alone with the mixed use of CTE and MRE for the periodic follow-up of small bowel inflammation in patients with CD. Materials and Methods: We retrospectively compared two non-randomized groups, each comprising 96 patients with CD. One group underwent CTE and MRE (MRE followed by CTE or vice versa) for the follow-up of CD (interval, 13-27 months [median, 22 months]), and the other group underwent MRE alone (interval, 15-26 months [median, 21 months]). However, these two groups were similar in clinical characteristics. Three independent readers from three different institutions determined whether inflammation had decreased, remained unchanged, or increased within the entire small bowel and the terminal ileum based on sequential enterography of the patients after appropriate blinding. We compared the two groups for inter-reader agreement and accuracy (terminal ileum only) using endoscopy as the reference standard for enterographic interpretation. Results: The inter-reader agreement was greater in the MRE alone group for the entire small bowel (intraclass correlation coefficient [ICC]: 0.683 vs. 0.473; p = 0.005) and the terminal ileum (ICC: 0.656 vs. 0.490; p = 0.030). The interpretation accuracy was higher in the MRE alone group without statistical significance (70.9%-74.5% vs. 57.9%-64.9% in individual readers; adjusted odds ratio = 3.21; p = 0.077). Conclusion: The mixed use of CTE and MRE was inferior to MRE alone in terms of inter-reader reliability and could probably be less accurate than MRE alone for routine monitoring of small bowel inflammation in patients with CD. Therefore, the consistent use of MRE is favored for this purpose.

Deep Learning-Assisted Diagnosis of Pediatric Skull Fractures on Plain Radiographs

  • Jae Won Choi;Yeon Jin Cho;Ji Young Ha;Yun Young Lee;Seok Young Koh;June Young Seo;Young Hun Choi;Jung-Eun Cheon;Ji Hoon Phi;Injoon Kim;Jaekwang Yang;Woo Sun Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.343-354
    • /
    • 2022
  • Objective: To develop and evaluate a deep learning-based artificial intelligence (AI) model for detecting skull fractures on plain radiographs in children. Materials and Methods: This retrospective multi-center study consisted of a development dataset acquired from two hospitals (n = 149 and 264) and an external test set (n = 95) from a third hospital. Datasets included children with head trauma who underwent both skull radiography and cranial computed tomography (CT). The development dataset was split into training, tuning, and internal test sets in a ratio of 7:1:2. The reference standard for skull fracture was cranial CT. Two radiology residents, a pediatric radiologist, and two emergency physicians participated in a two-session observer study on an external test set with and without AI assistance. We obtained the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity along with their 95% confidence intervals (CIs). Results: The AI model showed an AUROC of 0.922 (95% CI, 0.842-0.969) in the internal test set and 0.870 (95% CI, 0.785-0.930) in the external test set. The model had a sensitivity of 81.1% (95% CI, 64.8%-92.0%) and specificity of 91.3% (95% CI, 79.2%-97.6%) for the internal test set and 78.9% (95% CI, 54.4%-93.9%) and 88.2% (95% CI, 78.7%-94.4%), respectively, for the external test set. With the model's assistance, significant AUROC improvement was observed in radiology residents (pooled results) and emergency physicians (pooled results) with the difference from reading without AI assistance of 0.094 (95% CI, 0.020-0.168; p = 0.012) and 0.069 (95% CI, 0.002-0.136; p = 0.043), respectively, but not in the pediatric radiologist with the difference of 0.008 (95% CI, -0.074-0.090; p = 0.850). Conclusion: A deep learning-based AI model improved the performance of inexperienced radiologists and emergency physicians in diagnosing pediatric skull fractures on plain radiographs.

99mTc-3PRGD2 SPECT/CT Imaging for Diagnosing Lymph Node Metastasis of Primary Malignant Lung Tumors

  • Liming Xiao;Shupeng Yu;Weina Xu;Yishan Sun;Jun Xin
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1142-1150
    • /
    • 2023
  • Objective: To evaluate 99mtechnetium-three polyethylene glycol spacers-arginine-glycine-aspartic acid (99mTc-3PRGD2) single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging for diagnosing lymph node metastasis of primary malignant lung neoplasms. Materials and Methods: We prospectively enrolled 26 patients with primary malignant lung tumors who underwent 99mTc-3PRGD2 SPECT/CT and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT imaging. Both imaging methods were analyzed in qualitative (visual dichotomous and 5-point grades for lymph nodes and lung tumors, respectively) and semiquantitative (maximum tissue-to-background radioactive count) manners for the lymph nodes and lung tumors. The performance of the differentiation of lymph nodes with and without metastasis was determined at the per-lymph node station and per-patient levels using histopathological results as the reference standard. Results: Total 42 stations had metastatic lymph nodes and 136 stations had benign lymph nodes. The differences between metastatic and benign lymph nodes in the visual qualitative and semiquantitative analyses of 99mTc-3PRGD2 SPECT/CT and 18F-FDG PET/CT were statistically significant (all P < 0.001). The area under the receiver operating characteristic curve (AUC) in the semi-quantitative analysis of 99mTc-3PRGD2 SPECT/CT was 0.908 (95% confidence interval [CI], 0.851-0.966), and the sensitivity, specificity, positive predictive value, and negative predictive value were 0.86 (36/42), 0.88 (120/136), 0.69 (36/52), and 0.95 (120/126), respectively. Among the 26 patients (including two patients each with two lung tumors), 15 had pathologically confirmed lymph node metastasis. The difference between primary lung lesions in patients with and without lymph node metastasis was statistically significant only in the semi-quantitative analysis of 99mTc-3PRGD2 SPECT/CT (P = 0.007), with an AUC of 0.807 (95% CI, 0.641-0.974). Conclusion: 99mTc-3PRGD2 SPECT/CT imaging may notably perform in the direct diagnosis of lymph node metastasis of primary malignant lung tumors and indirectly predict the presence of lymph node metastasis through uptake in the primary lesions.

The Error Pattern Analysis of the HMM-Based Automatic Phoneme Segmentation (HMM기반 자동음소분할기의 음소분할 오류 유형 분석)

  • Kim Min-Je;Lee Jung-Chul;Kim Jong-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.5
    • /
    • pp.213-221
    • /
    • 2006
  • Phone segmentation of speech waveform is especially important for concatenative text to speech synthesis which uses segmented corpora for the construction of synthetic units. because the quality of synthesized speech depends critically on the accuracy of the segmentation. In the beginning. the phone segmentation was manually performed. but it brings the huge effort and the large time delay. HMM-based approaches adopted from automatic speech recognition are most widely used for automatic segmentation in speech synthesis, providing a consistent and accurate phone labeling scheme. Even the HMM-based approach has been successful, it may locate a phone boundary at a different position than expected. In this paper. we categorized adjacent phoneme pairs and analyzed the mismatches between hand-labeled transcriptions and HMM-based labels. Then we described the dominant error patterns that must be improved for the speech synthesis. For the experiment. hand labeled standard Korean speech DB from ETRI was used as a reference DB. Time difference larger than 20ms between hand-labeled phoneme boundary and auto-aligned boundary is treated as an automatic segmentation error. Our experimental results from female speaker revealed that plosive-vowel, affricate-vowel and vowel-liquid pairs showed high accuracies, 99%, 99.5% and 99% respectively. But stop-nasal, stop-liquid and nasal-liquid pairs showed very low accuracies, 45%, 50% and 55%. And these from male speaker revealed similar tendency.

Diagnostic Performance of Cardiac CT and Transthoracic Echocardiography for Detection of Surgically Confirmed Bicuspid Aortic Valve: Effect of Calcium Extent and Valve Subtypes (외과적으로 확진된 이첨 대동맥 판막의 진단을 위한 심장 CT 및 경흉부 심초음파의 진단적 성능: 판막 아형 및 칼슘의 양이 미치는 효과)

  • Jeongju Kim;Sung Mok Kim;Joonghyun Ahn;Jihoon Kim;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1324-1336
    • /
    • 2023
  • Purpose This study aimed to compare the diagnostic performance of cardiac CT and transthoracic echocardiogram (TTE) depending on the degree of valvular calcification and bicuspid aortic valve (BAV) subtype. Materials and Methods This retrospective study included 266 consecutive patients (106 with BAV and 160 with tricuspid aortic valve) who underwent cardiac CT and TTE before aortic valve replacement. Cardiac CT was used to evaluate the morphology of the aortic valve, and a calcium scoring scan was used to quantify valve calcium. The aortic valves were classified into fused and two-sinus types. The diagnostic accuracy of cardiac CT and TTE was calculated using a reference standard for intraoperative inspection. Results CT demonstrated significantly higher sensitivity, negative predictive value, and accuracy than TTE in detecting BAV (p < 0.001, p < 0.001, and p = 0.003, respectively). The TTE sensitivity tended to decrease as valvular calcification increased. The error rate of TTE for CT was 10.9% for the twosinus type of BAV and 28.3% for the fused type (p = 0.044). Conclusion Cardiac CT had a higher diagnostic performance in detecting BAV than TTE and may help diagnose BAV, particularly in patients with severe valvular calcification.

Development of evaluation items for accessing practice and compliance with dietary guidelines among Korean adults (성인 대상 한국인을 위한 식생활지침 실천 및 순응도 평가 항목 개발)

  • Min-Ah Kim;Sung-Min Yook;Jieun Oh;Jimin Lim;Hye Ji Seo;Young-Suk Lim;Ji Soo Oh;Hye-Young Kim ;Ji-Yun Hwang
    • Journal of Nutrition and Health
    • /
    • v.57 no.2
    • /
    • pp.244-260
    • /
    • 2024
  • Purpose: With the 2021 revision of dietary guidelines in Korean emphasizing environmentally sustainable dietary practices, this study attempted to develop an evaluation tool to comprehensively evaluate the degree of practice and compliance with food and nutrient intake, dietary habits, and dietary culture guidelines based on the revised dietary guidelines. Methods: The candidate evaluation items were collected by reviewing 934 literature reviews on domestic and foreign dietary evaluations. Fifty-nine candidate items were derived by selecting the items corresponding to dietary guidelines. The content validity ratio (CVR) cutoff point evaluation was conducted with 11 experts to delete 11 items that did not meet the CVR standard. Fifty-five pilot survey candidate items were selected through revision and additional process according to expert opinion. Seventy final candidate items were selected by adding 15 questions for validity verification and reference. A pilot survey was conducted online and offline on 332 adults aged 19-64 in Seoul and the metropolitan area, and exploratory factor analysis was used to verify the construct validity of the evaluation items. Through exploratory factor analysis, the Kaiser-Meyer-Olkin, Bartlett's sphericity test, variance explained, and Cronbach's alpha criteria were confirmed in each process. Results: Exploratory factor analyses derived three criteria: food and nutrient intakes (11 items), eating behaviors (9 items), and dietary culture (14 items), consisting of 34 evaluation items. Conclusion: The present scale was validated and can be used for comprehensive evaluations of the dietary guidelines for Korean adults in a simple way.