• Title/Summary/Keyword: reference standard

Search Result 2,162, Processing Time 0.023 seconds

Study of Clinical Practice Standardization in Dental Hygiene (치위생(학)과 임상실습 표준화 방안)

  • Shin, Sun-Jung;Kim, Mi-Jeong;Yang, Jin-Young;Yu, Ji-Su;Jeoung, A-Yeon;Shin, Myong-Suk
    • Journal of dental hygiene science
    • /
    • v.17 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • There are 82 dental hygiene departments and clinical training institutes across the country with a very wide range of clinical practice content and evaluation methods, making standardization difficult. Therefore, there is a need to establish a standard protocol outlining clinical practice content and evaluation methods for systematic and efficient operation of clinical practice. Thus, this study attempted to propose such a protocol for standardization of dental hygiene clinical practice in dental clinics and hospitals to examine the contents of clinical practice by reviewing relevant literature, and relating it to professional practice within the dental hygienic curriculum to facilitate enhancement of expertise. Clinical practice content was extracted from 74 cases, and was consisted of classifying mandatory and optional clinical practice, training time, and activity methods for each component. To standardize effective clinical practice, it is necessary to organize the components acquired in the course of clinical dentistry training in line with their arrangement on each university's curriculum, in order to learn all components step by step. To do this, it is necessary to present a standardized clinical practice protocol and a organic cooperation between educational institutions and clinical training institutions.

A Hardwired Location-Aware Engine based on Weighted Maximum Likelihood Estimation for IoT Network (IoT Network에서 위치 인식을 위한 가중치 방식의 최대우도방법을 이용한 하드웨어 위치인식엔진 개발 연구)

  • Kim, Dong-Sun;Park, Hyun-moon;Hwang, Tae-ho;Won, Tae-ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.32-40
    • /
    • 2016
  • IEEE 802.15.4 is the one of the protocols for radio communication in a personal area network. Because of low cost and low power communication for IoT communication, it requires the highest optimization level in the implementation. Recently, the studies of location aware algorithm based on IEEE802.15.4 standard has been achieved. Location estimation is performed basically in equal consideration of reference node information and blind node information. However, an error is not calculated in this algorithm despite the fact that the coordinates of the estimated location of the blind node include an error. In this paper, we enhanced a conventual maximum likelihood estimation using weighted coefficient and implement the hardwired location aware engine for small code size and low power consumption. On the field test using test-beds, the suggested hardware based location awareness method results better accuracy by 10 percents and reduces both calculation and memory access by 30 percents, which improves the systems power consumption.

Characteristics of Heavy Metals (Ba, Cr) Distribution in Soil (토양 중 중금속(Ba, Cr)의 분포특성 평가)

  • Yoon, Jeong-Ki;Kim, Rog-Young;Kim, Ji In;Noh, Hoe-Jung;Yu, Soon-Ju;Kim, Tae Seung;Lee, Myung Gyu;Yun, Dae-Geun;Lee, Hong-gil;Kim, In Ja;Park, Gyoung-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.7
    • /
    • pp.61-69
    • /
    • 2015
  • This study was performed to provide fundamental data to establish the new soil pollution standards and the soil contamination management plans in a rational manner. The distribution characteristics of new soil contaminants such as barium (Ba) and chromium (Cr) in soils (n=140) were investigated in relation to land-use classification and geological features. Also, the sequential extraction test was conducted to evaluate fate and mobility of new soil contaminants. The soil samples taken from 140 sites were analyzed to survey distribution levels of selected new soil contaminants. The average concentration and range for hazardous metals (Ba, Cr) were Ba 128.946 (26.757~489.587) mg/kg, Cr 30.121 (2.579~132.783) mg/kg. Based on land use classification, the highest Ba concentration was found in factory soils, followed by dry field and park soils, while Cr concentration was highest in rice paddy soils, followed by dry field and factory soils. Within 10 geological units investigated the highest Ba and Cr concentrations were observed in the soils from Okcheon group and metamorphic rocks, respectively. The BCR (European Community Bureau of Reference) sequential extraction was conducted to identify chemical distributional existence of 2 elements of soils from each geological unit. Ba in soils is mainly assumed to exists as reducible form (such as BaSO4, BaCO3) and Cr in soils mainly is assumed to exist as residual form (such as Cr2O3, CrxFe1-x(OH)3(x < 1)).

Evaluation of The Hygrothermal Performance by Wall Layer Component of Wooden Houses Using WUFI Simulation Program (WUFI 시뮬레이션 프로그램을 이용한 목조주택 벽체 레이어 구성에 따른 hygrothermal 성능 평가)

  • Kang, Yujin;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.75-84
    • /
    • 2016
  • Thermal performance of wooden houses used by building materials effectively contributing to building energy saving has been improved. However, the performance was decreased to the condensation and mould growth from exterior wall because the moisture control was difficult to high insulation and airtightness. Therefore, the hygrothermal performance of exterior wall, that selected 5 types of wooden houses, evaluated using the hygrothermal simulation program: heat and moisture behavior, condensation and mould growth risk. Wooden houses were selected Rural houses standard plans '10 and '14, $2^{{\prime}{\prime}}{\times}6^{{\prime}{\prime}}$ type, EIFS and wood-based passive house. And the wall A, B, C, D and E were determined by layer component of each wall. The U-value of exterior wall are 0.171, 0.172, 0.221, 0.150, $0.079W/m^2K$. The OSB absolute water content of the wall A and C was exceeds the reference value of 20%, and it was confirmed that condensation occur at insulation material inner surface through the condensation evaluation in the winter. The wall D and E showed excellent results with condensation and water content evaluation compared to others. However, mould growth risk assessment in all five types of wall had have risk. We were determined that hygrothermal performance difference of exterior wall occur the difference in the layer structure rather than in thermal performance.

A Study on Phase-Multiplexed Volume Hologram using Spatial Light Modulator (공간광변조기를 이용한 위상다중화 체적 홀로그램에 관한 연구)

  • Jo, Jong-Dug;Kim, Kyu-Tae
    • 전자공학회논문지 IE
    • /
    • v.44 no.3
    • /
    • pp.23-34
    • /
    • 2007
  • For an effective phase multiplexing in a volume holographic system, four types of phase code, pseudo random code(PSC), Hadamard matrix(HAM), pure random code(PRC), equivalent random code(ERC), used as reference beams are generated. In case of $32{\times}32$ address beam, a phase error with 0%, 5%, 10%, 15%, 20%, and 25% error rate, is purposely added to the real phase values in order to consider the practical SLM's nonlinear characteristics of phase modulation in computer simulation. Crosstalks and SNRs(signal-to-ratio) are comparatively analyzed for these phase codes by the auto-correlation and cross-correlation. PSC has the lowest cross-correlation mean value of 0.067 among four types of phase code, which means the SNR of the pseudo random phase code is higher than other phase codes. Also, the standard deviation of the pseudo random phase code indicating the degree of recalled data degradation is the lowest value of 0.0113. In order to analyze the affect by variation of pixel size, simulation is carried out by same method for the case of $32{\times}32$, $64{\times}64$, $128{\times}128$, $256{\times}256$ address beams.

The Establishment and Design of the Science Class in Cyber Space (사이버과학교실시스템 설계 및 구현)

  • Kim, Mi-Young;Kweon, Hyo-Soon;Park, Hye-Ock
    • Journal of Engineering Education Research
    • /
    • v.9 no.4
    • /
    • pp.28-45
    • /
    • 2006
  • As society has changed to being more knowledge-based, it is indispensable that Internet usage is incorporated into education. Therefore, the e-learning system is being developed in order to provide a proper environment. However, many LCMS that were developed, currently are not based on SCORM, the world e-learning standard, nor KEM, the Korea Educational Metadata of Korea Education & Research Information Service(KERIS), and hence, it is difficult to share learning contents developed from such varied environments. National Science Museum, a non-educational institution, also provides the educational science exhibits in reality or in cyber space, which cannot be produced by elementary schools, and secondary schools. Consequently, new systems are necessary, whose modules should be divided into four, for example, 'teachers', 'learners', 'managers', and 'instructors', and be associated with each other so that they are able to integrate and manage such systems, and be used in school education as well. Therefore, in this study, more advanced LMS and LCMS, which are the web-portal sites used for a cyber science class at the National Science Museum, were designed and established. These sites were surely based on the KEM, and the SCORM.

Study on Physicochemical Properties of Pesticide. (I) Water Solubility, Hydrolysis, Vapor Pressure, and n-Octanol/water Partition Coefficient of Captafol (농약의 물리화학적 특성연구 (I) Captafol의 수용성, 가수분해, 증기압, 옥탄올/물 분배계수)

  • Kim, Jeong-Han;Lee, Sung-Kyu;Kim, Yong-Hwa;Kim, Kyun
    • Applied Biological Chemistry
    • /
    • v.40 no.1
    • /
    • pp.71-75
    • /
    • 1997
  • Important physicochemical properties of captafol [N-(1,1,2,2-tetrachloro-ethylthio)cyclohex-4-ene-1,2-dicarboximide], water solubility, vapor pressure, hydrolysis and octanol/water partition coefficient(Kow) were measured based on the standard EPA and OECD methods. Water solubility of the chemical was 2.24 ppm at $25^{\circ}C$. Half-life by hydrolysis at $25^{\circ}C$ in the buffer solution of pH 3.0, pH 7.0, and pH 8.0 was 77.8 hr, 6.54 hr and 0.72 hr, respectively, demonstrating instability in alkaline solution. The half-life in acid condition was not significantly different by temperature change, however, that in neutral or alkaline solution became shorter at $40^{\circ}C$. Hydrolysis study with a reference compound, diazinon, proved that the experimental method of the present study is reliable. Vapor pressure of captafol, $8.27{\times}10^{-9}$ torr at $20^{\circ}C$, was calculated from the equation, log P=6.94-(4401.6/T) plotted on the experiment results under different temperature conditions, 40, 50, and $60^{\circ}C$. pressure of captafol, the contamination of captafol would not happen easily in environment by vaporization. High Kow value of 1,523 was observed and this might result in bioconcentration through food chain when captafol was exposed. However, affecting human health through aquatic bioaccumulation is not likely to occur due to its rapid hydrolysis in the environment.

  • PDF

A Hierarchical Group-Based CAVLC Decoder (계층적 그룹 기반의 CAVLC 복호기)

  • Ham, Dong-Hyeon;Lee, Hyoung-Pyo;Lee, Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.2
    • /
    • pp.26-32
    • /
    • 2008
  • Video compression schemes have been developed and used for many years. Currently, H.264/AVC is the most efficient video coding standard. The H.264/AVC baseline profile adopts CAVLC(Context-Adaptive Variable Length Coding) method as an entropy coding method. CAVLC gives better performance in compression ratios than conventional VLC(Variable Length Coding). However, because CAVLC decoder uses a lot of VLC tables, the CAVLC decoder requires a lot of area in terms of hardware. Conversely, since it must look up the VLC tables, it gives a worse performance in terms of software. In this paper, we propose a new hierarchical grouping method for the VLC tables. We can obtain an index of codes in the reconstructed VLC tables by simple arithmetic operations. In this method, the VLC tables are accessed just once in decoding a symbol. We modeled the proposed algorithm in C language, compiled under ARM ADS1.2 and simulated it with Armulator. Experimental results show that the proposed algorithm reduces execution time by about 80% and 15% compared with the H.264/AVC reference program JM(Joint Model) 10.2 and the arithmetic operation algorithm which is recently proposed, respectively.

Production and properties of ale beer with Nuruk, a Korean fermentation starter (전통누룩을 이용한 ale맥주 제조 및 품질특성)

  • Jung, Suji;Chung, Chang-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.132-140
    • /
    • 2017
  • Nuruk, a traditional Korean alcoholic beverage starter, was evaluated as an additional saccharifying agent comprising up to 1.5% (w/w) of malt weight in ale-type beer processing. Sample characteristics were monitored during fermentation, ripening, and storage. Beer containing nuruk showed higher numbers of total viable bacteria and yeast cell counts. Additionally, ethanol (6.19-6.35%), color (Standard Reference Method), foam stability ($228.49-368.24{Sigma}$), saccharogenic power (307-417), and reducing sugar (3.83-5.25%) increased as the amount of nuruk was increased, while viscosity (3.13-2.07 cP) and bitterness unit (19.68-13.13) were lower than in samples without nuruk. Overall acceptance and aftertaste of the beer were significantly higher in a preference test. These results demonstrate that nuruk can be used to produce a new type of ale.

Calibration of Hydrographic Survey Multibeam System Using Terrestrial Laser Scanning and TS Surveying (지상 레이저 스캐닝과 TS 측량을 이용한 멀티빔 시스템의 검·보정)

  • Kim, Jin Soo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.3
    • /
    • pp.199-207
    • /
    • 2013
  • In hydrographic survey, data surveyed with multibeam system includes various errors due to multiple factors. These are corrected by a calibration called patch test, and if existing method is used, the test needs to be conducted for about 8 times for precise system calibration. For more prompt and precise multibeam system calibration, the exact offset of a ship was determined using terrestrial laser scanning and TS surveying, which was used as the initial input for the patch test. In the result, the error of closure was 0.001 m or less for TS surveying and backsight error was 0.005 m or less for scanning. All the surveying data based on the same local coordinate was converted into vessel reference coordinate during which R-square for all rotation angles was 0.99 or higher and standard deviation was 0.008 m or less. Finally, in a patch test using calculated offset of sensors and motion sensor offset, the offset of MBES transducer satisfied manual on hydrography only with 1-time calibration. With these results, it is thought that terrestrial laser scanning and TS surveying can fully be utilized for multibeam system calibration.