• Title/Summary/Keyword: reference measurements

Search Result 848, Processing Time 0.029 seconds

Zero-Sean-Back Reference Height Generation Filter (Zero-Scan-Back 기준 고도 생성 필터)

  • Whang, Ick-Ho;Ra, Won-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.386-388
    • /
    • 2007
  • In many applications of UAVs flying in low altitude, the steady supply of accurate height measurements is very important for the UAVs to complete their mission successfully. In order to do this, a barometer or GPS height measurements are widely used. However, because these two sensors have their limitations in the application environment, a method for fusing these two measurements to produce reference heights are required. In this paper, a reference height generation filter is designed for UAV(Unmanned Air Vehicle) applications. The barometer errors originated by the change of the atmospheric environment are modeled using random walk models, and then the errors are identified and compensated through the ZSB(zero-scan-back) filter algorithm using the GPS height measurements. The performance of the proposed filter is demonstrated by realistic simulations.

  • PDF

Confirmation of reference value using uncertainty of multiple measurements (반복측정의 불확도를 이용한 인증값 확인)

  • Choi, Jong-Oh;So, Hun-Young;Woo, Jin-Chun;Hwang, Eui-Jin
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.580-583
    • /
    • 2002
  • New approach is developed employing the overall uncertainty obtained from multiple measurements to evaluate the statistical significance for the difference between a given reference value and its measured value determined in a lab. The overall uncertainty is determined by separate combinations of the uncertainties arising from systematic and random effects. It is shown that the uncertainty term in regular t-test can be underestimated by n measurements.

Reference line for computed tomogram of the mandible (하악골 전산화단층사진촬영시 기준선에 관한 연구)

  • You Choong-Hyun;Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.153-157
    • /
    • 2002
  • Purpose : This study was performed to determine the proper reference line for taking axial computed tomograms from which the good cross-sectional views can be reformatted by multiplanar reconstruction. Methods : Three dry mandibles with implanted gutta percha cones in the extracted socket were scanned axially according to 6 reference lines of 2 mandibular positions with computed tomogram Hitachi W550. The accuracy of measurements of the lengths of implanted gutta perch a cones in the each cross-sectional view reformatted from axial computed tomogram by multiplanar reconstruction was evaluated. Results: The difference between the measurements and the real length of implant was smallest in the bucco-lingual views reformatted from the axial views scanned according to the reference line of group V-a. The smaller the angle difference between reference line and occlusal line was, the smaller the difference between the measurements in the bucco-lingual views reformatted from axial views and the real length of implant. The majority of measured widths of implants in the bucco-lingually reformatted views were larger than the actual values. Conclusions : When the mandible is inclined within the limitation of gantry angle and scanned with the reference line coincident with occlusal plane, the bucco-lingual view can be reformatted without deformation of images from the axially scanned images.

  • PDF

The Apparel Sizing System of Early Adolescent Gins - focusing on Upper Garments - (청소년 전기 여학생의 상의 치수 규격에 관한 연구)

  • Suh Mi-A;Jeong Hwa-Yeon
    • The Research Journal of the Costume Culture
    • /
    • v.13 no.4 s.57
    • /
    • pp.526-539
    • /
    • 2005
  • Recently in the apparel industry, early adolescent girls are emerging as a new consumer group. In response to this, companies are developing clothes, cosmetics, underwear, etc. This study proposed a new size range and size interval for early adolescent girls and presented reference measurements for body parts necessary in designing clothes. For this purpose, a total of 529 girls aged between 10 and 14 were measured and data were collected from 42 anthropometric measurements and 41 photographic measurements per a person. SAS 8.1 was used in data analysis including means, standard deviations, frequency analysis. Based on the results, this study proposed: for Type A - 7 sizes (140A-67, 145A-65, 145A-69, 150A-69, 150A-73, 155A-73, 155A-76): for Type X - 7 sizes (150x-72, 155x-72, 155x-77, 160x-77, 160x-80, 165x-77, 165x-80); and for Type H - 8 sizes (145H-74, 145H-82, 150H-78, 150H-82, 155H-82, 155H-86, 160H-86, 160H-88). Reference measurements suggested for upper garments were 9 items. The outcome of this study may be used as a basic material for adolescent apparel manufacturers to set their apparel sizing system and to supply their consumers, namely, adolescent girls with products fitting their somatotype.

  • PDF

Test Results of Wide-Area Differential Global Positioning System with Combined Use of Precise Positioning Service and Standard Positioning Service Receiver

  • Kim, Kap Jin;Ahn, Jae Min
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.1
    • /
    • pp.43-48
    • /
    • 2021
  • Most existing studies on the wide-area differential global positioning system (WADGPS) used standard positioning service (SPS) receivers in their observation reference stations which provide the central control station global positioning system (GPS) measurements to generate augmentation data. In the present study, it is considered to apply a precise positioning service (PPS) receiver to an observation reference station which is located in the threatened jamming area. Therefore, the reference station network consists of a PPS receiver based observation reference station and SPS receiver based observation reference stations. In this case, to maintain correction performance P1C1 differential code bias (DCB) should be compensated. In this paper, P1C1 DCB estimation algorithm was applied to the PPS/WADGPS system and performance test results using measurements in the Korean Peninsula were presented.

COMPARISONS OF MEASUREMENTS OBTAINED FROM LATERAL CEPHALOMETRIC RADIOGRAPHS AND DIGIGRAPHS OF DOLPHIN IMAGING SYSTEM (측모 두부 방사선사진과 컴퓨터 영상사진 (Dolphin Imaging System)의 계측치 에 관한 비교)

  • Park, Hae-Joon;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.24 no.3 s.46
    • /
    • pp.521-534
    • /
    • 1994
  • The purpose of this study was to compare the differences in measurements between cephalometric radiographs and digigraphs of Dolphin Imaging System. 26 Korean adult male and 24 adult female with normal occlusion were selected. For each subject lateral cephalogram was taken. Digitizing with Digigraph Work Station of Dolphin in System. was performed as well. 50 tracings and 50 digigraphs were analyzed with Yonsei, Ricketts, Burstone analyses. The comparable measurements between tracing group and digigraph group were statistically analyzed. The results were as follows: 1. 13 of 64 comparable measurements did not show any statistically significant difference (P>0.05) between tracing group and digigraph group. 2. Three of the measurements with FH plane as a reference plane did not show any statistically insignificant difference. All measurement with SN plane as a reference plane showed statistically significant difference(p<0.05). 3. The measurements which showhed no statistically significant difference were mostly short distance linear measurements while most of the angular measurements showed statistically significant difference(p<0.05).

  • PDF

Assessment of The Accuracy of The MR Abdominal Adipose Tissue Volumetry using 3D Gradient Dual Echo 2-Point DIXON Technique using CT as Reference

  • Kang, Sung-Jin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.603-615
    • /
    • 2016
  • In this study, in order to determine the validity and accuracy of MR imaging of 3D gradient dual echo 2-point DIXON technique for measuring abdominal adipose tissue volume and distribution, the measurements obtained by CT were set as a reference for comparison and their correlations were evaluated. CT and MRI scans were performed on each subject (17 healthy male volunteers who were fully informed about this study) to measure abdominal adipose tissue volume. Two skilled investigators individually observed the images acquired by CT and MRI in an independent environment, and directly separated the total volume using region-based thresholding segmentation method, and based on this, the total adipose tissue volume, subcutaneous adipose tissue volume and visceral adipose tissue volume were respectively measured. The correlation of the adipose tissue volume measurements with respect to the observer was examined using the Spearman test and the inter-observer agreement was evaluated using the intra-class correlation test. The correlation of the adipose tissue volume measurements by CT and MRI imaging methods was examined by simple regression analysis. In addition, using the Bland-Altman plot, the degree of agreement between the two imaging methods was evaluated. All of the statistical analysis results showed highly statistically significant correlation (p<0.05) respectively from the results of each adipose tissue volume measurements. In conclusion, MR abdominal adipose volumetry using the technique of 3D gradient dual echo 2-point DIXON showed a very high level of concordance even when compared with the adipose tissue measuring method using CT as reference.

Measurements of the rheological properties of standard reference material 2490 using an in-line micro-Fourier rheometer

  • Smith R. S.;Glasscock J. A.
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.4
    • /
    • pp.169-173
    • /
    • 2004
  • The control of the rheological properties of a fluid during processing is important and can determine the efficiency of the production in addition to the performance of the final product. The vast majority of process fluids are viscoelastic, hence an instrument that measures both the viscous and elastic properties of the material during processing would be of great practical use. However, most in-line instruments commercially available to date are only capable of measuring viscosity at a single shear rate. An in-line rheometer that measures both the viscous and elastic properties of fluids over a wide range of shear rates simultaneously has been described in a previous publication (Glasscock et at., 2003) in which the results of measurements on flowing sunflower oil were presented. Before this instrument can be used in an industrial situation, it must be demonstrated that the generated results are the same as, or bear some fixed relationship to, the results obtained by conventional off-line rheometers. To this end, the present investigation describes the measurements of a standard reference fluid, polyisobutylene dissolved in 2,6,10,14-tetramethylpentadecane, labelled SRM2490 by the National Institute of Standards and Technology (NIST) in the USA. The results obtained using the in-line rheometer show remarkably good correlation for viscosity, using a modified Cox­Merz rule, with the results supplied with the reference material from NIST.

A Study on the Current Status of Sizing System for Infants' & Children's Clothing (시판 유아동복 치수체계에 관한 연구)

  • Jung, Myoung Sook;Kang, Hye Jin;Jang, In Sun
    • Journal of the Korean Society of Costume
    • /
    • v.64 no.2
    • /
    • pp.70-83
    • /
    • 2014
  • This study was done to provide the basic data for improving the sizing system for infants and children's clothing. The 97 brands were surveyed through market research and on-line searching. Size and body measurements were analyzed according to the content of nominal size, type of market, national and foreign brands, and meaning of reference size. The results are as follows: 1. The meaning of nominal sizes was categorized as five cases: the size based on body measurements, the size based on age, the meaningless size, letter cord and combination of 2 out of 4 cases above. The nominal size based on height was most observed, and the meaningless nominal size was second. The meaningless nominal size can cause confusion when consumer buys clothing. 2. The department stores mainly used the nominal size based on body measurements, but the Internet shopping malls largely used the meaningless nominal size. 3. Both national brands and foreign brands mainly used the nominal size based on height. But national brands largely used the different nominal sizes. 4. 41 brands indicated body measurements as reference size and 26 brands indicated product measurements as reference size. Therefore consumers tended to confuse the body measurements with the product measurement.

Electrical Power and Energy Reference Measurement System with Asynchronous Sampling (비동기 샘플링에 의한 전력과 에너지 측정 기준시스템)

  • Wijesinghe, W.M.S.;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.684_685
    • /
    • 2009
  • A digital sampling algorithm that uses a two high resolution integrating Voltmeters which are synchronized by Phase Lock Loop (PLL) time clock for accurately measuring the parameters, active and reactive power, for sinusoidal power measurements is presented. The PLL technique provides high precision measurements, root mean square (rms), phase and complex voltage ratio, of the AC signal. The system has been designed to be used at the Korean Research Institute of Standards and Science (KRISS) as a reference power standard for electrical power calibrations. The test results have shown that the accuracy of the measurements is better than $10 {\mu}W/VA$ and the level of uncertainty is valid for the power factor range zero to 1 for both lead and lag conditions. The system is fully automated and allows power measurements and calibration of high precision wattmeters and power calibrators at the main power frequencies 50 and 60 Hz.

  • PDF