• Title/Summary/Keyword: reference line

Search Result 1,106, Processing Time 0.024 seconds

A development of the simple camera calibration system using the grid type frame with different line widths (다른 선폭들로 구성된 격자형 교정판을 이용한 간단한 카메라 교정 시스템의 개발)

  • 정준익;최성구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.371-374
    • /
    • 1997
  • Recently, the development of computer achieves a system which is similar to the mechanics of human visual system. The 3-dimensional measurement using monocular vision system must be achieved a camera calibration. So far, the camera calibration technique required reference target in a scene. But, these methods are inefficient because they have many calculation procedures and difficulties in analysis. Therefore, this paper proposes a native method that without reference target in a scene. We use the grid type frame with different line widths. This method uses vanishing point concept that possess a rotation parameter of the camera and perspective ration that perspect each line widths into a image. We confirmed accuracy of calibration parameter estimation through experiment on the algorithm with a grid paper with different line widths.

  • PDF

Estimation of Fault Location on a Power Line using the Time-Frequency Domain Reflectometry (절연전선 결함 위치 추정에 대한 시간-주파수 영역 반사파 계측법의 적용)

  • Doo, Seung-Ho;Kwak, Ki-Seok;Park, Jin-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.268-275
    • /
    • 2008
  • In this paper, we introduce a new method for detecting and estimating faults on a power line using the time-frequency domain reflectometry system. The system rests upon time-frequency signal analysis and uses a chirp signal which is multiplied by Gaussian envelope. The chirp signal is used as a reference signal, and we can get the reflected signal from a fault on a wire. To detect and estimate faults, we analyze the reflected signal by Wigner time-frequency distribution function and normalized time-frequency cross correlation function. In this paper we design an optimal reference signal for power line and implement a system for estimating fault distance on a power line with the TFDR implemented by PXI equipments. This approach is verified by some experiments with HIV 2.25mm power lines.

A Preliminary Cut-off Indoor Positioning Scheme Using Beacons (비콘을 활용하여 실내위치 찾는 사전 컷-오프 방식)

  • Kim, Dongjun;Park, Byoungkwan;Son, Jooyoung
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.2
    • /
    • pp.110-115
    • /
    • 2017
  • We propose a new indoor positioning algorithm named Cut-off algorithm. This algorithm cuts off candidates of beacons and reference points in advance, before looking for K neighbor reference points which are guessed to be closest to the user's actual location. The algorithm consists of two phases: off-line phase, and on-line phase. In the off-line phase, RSSI and UUID data from beacons are gathered at reference points placed in the indoor environment, and construct a fingerprint map of the data. In the on-line phase, the map is reduced to a smaller one according to the RSSI data of beacons received from the user's device. The nearest K reference points are selected using the reduced map, which are used for estimating user's location. In both phases, relative ranks of the peak signals received from each beacon are used, which smoothen the fluctuations of the signals. The algorithm is shown to be more efficient in terms of accuracy and estimating time.

Frankfort horizontal plane is an appropriate three-dimensinal reference in the evaluation of clinical and skeletal cant

  • Oh, Suseok;Ahn, Jaemyung;Nam, Ki-Uk;Paeng, Jun-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.2
    • /
    • pp.71-76
    • /
    • 2013
  • Objectives: In three-dimensional computed tomography (3D-CT), the cant is evaluated by measuring the distance between the reference plane (or line) and the tooth. The purpose of this study was to determine the horizontal skeletal reference plane that showed the greatest correlation with clinical evaluation. Materials and Methods: The subjects were 15 patients who closed their eyes during the CT image taking process. The menton points of all patients deviated by more than 3 mm. In the first evaluation, clinical cant was measured. The distance from the inner canthus to the ipsilateral canine tip and the distance from the eyelid to the ipsilateral first molar were obtained. The distance between the left and right sides was also measured. In the second evaluation, skeletal cant was measured. Six reference planes and one line were used for the evaluation of occlusal cant: 1) FH plane R: Or.R - Or.L - Po.R; 2) FH plane L: Or.R - Or.L - Po.L; 3) F. Ovale plane R: Rt.F.Ovale - Lt.F.Ovale - Or.R; 4) F. Ovale plane L: Rt.F.Ovale - Lt.F.Ovale - Or.L; 5) FZS plane R: Rt.FZS - Lt.FZS - Po.R; 6) FZS plane R: Rt.FZS - Lt.FZS - Po.L, and; 7) FZS line: Rt.FZS - Lt.FZS. Results: The clinical and skeletal cants were compared using linear regression analysis. The FH plane R, FH plane L, and FZS line showed the highest correlation (P<0.05). Conclusion: The FH plane R and FH plane L are the most appropriate horizontal reference plane in evaluation of occlusal cant on 3D-CT.

The Perceived Benefits of Electronic/digital Reference Services in Nigerian University Libraries: a survey

  • Uzoigwe, Comfort U.;Eze, Jacintha U.
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.8 no.2
    • /
    • pp.49-65
    • /
    • 2018
  • Are the benefits derived from ICT based reference and information service worth the financial and other commitments devoted to it? In an attempt to answer this, this study delved into finding out the perceived benefits; the rational for ICT based reference services in Nigerian university libraries. The main objectives were to find out the purposes for using ICT facilities in reference services delivery and the perceived benefits derived from using ICT resources in reference and information services. Being a survey, questionnaire was used to collect data from the librarians of twelve (12) universities; two (2) each sampled from the six geopolitical zones of Nigeria. Data was analyzed using frequencies, mean scores and standard deviations. ANOVA statistical analysis was used to test the hypothesis of no significance difference in the benefits derived from ICT based reference services using p-value of 0.05 to calculate the level of significance. Findings showed that librarians and library users made use of ICT facilities for different reference purposes especially to obtain information they need using the internet. Other reference needs for which patrons used the ICT facilities included: - access to current e-books and e - journals, user education and access to global information in other libraries. Provision of current awareness services (CAS) and selective dissemination of information services (SDI), on-line searching using workstations in the library, provision of on-line public access catalogue (OPAC) services, keeping statistics of users of the reference section and compilation of bibliographies. Further findings showed that the librarians and library users derive a lot of benefits from their use of ICT facilities in reference services. The results showed that easy retrieval and dissemination of information to patrons were ranked highest by the librarians amongst others.

EFFICACY OF ENaP(ESTHETIC NaP)-LINE FOR ORTHOGNATHIC SURGERY OF KOREAN MANDIBULAR PROGNATHISM (한국인 하악골 전돌증 환자의 악교정수술을 위한 ENaP(Esthetic NaP)선의 유효성에 관한 연구)

  • Kim, Jong-Kook;Park, Hyung-Sik
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.5
    • /
    • pp.372-382
    • /
    • 2002
  • As the most of dentofacial deformity patients indicated to orthognathic surgery have strong desire for esthetic improvement as well as functional improvement, ideal esthetic evaluation should be made at surgical prediction. Lateral cephalographs has been commonly used for surgical prediction, however, remarkable discrepancy between esthetic viewpoint by simple looking and analysis on lateral cephalographs often found on evaluation of sagittal position of the upper and lower jaws especially in cases of mandibular prognathism of Koreans. In these cases, we have been employed Esthetic NaP(ENaP)-line for corrective evaluation and ideal surgical prediction on lateral cephalographs, but the efficacy of ENaP-line has not been evaluated. This is a study on efficacy of ENaP-line for orthognathic surgery of Korean mandibular prognathism. 170 Korean patients who had been diagnosed as mandibular prognathism and planned for orthognathic surgery at Department of Oral and Maxillofacial Surgery, College of Dentistry, Yonsei University during last 10 years are studied. The obtained results are as followings; among 170 patients of mandibular prognathism, 132 patients(77.6%) had not discrepancy in evaluation of sagittal position of the maxilla between cephalometric and esthetic evaluation(they are classified as Group I), however, 38 patients(22.4%) had definite discrepancy(they are classified as Group II). ENaP-line was employed in all cephalometric analysis of Group II. The proportions of male and female were similar in both Groups. Sixteen vertical reference lines perpendicular to 16 horizontal reference lines were obtained as followings; Each of the representative degree of ${\angle}SN/AFH$, ${\angle}SN/CFH$ and ${\angle}AFH/CFH$ obtained at Group I was applied to SN plane, AFH plane and CFH plane of Group II each other, and so 16 horizontal reference lines could be obtained individually according to each of the applied degree to each plane. And then their reliability to coincide with ENaP-line of Group II was evaluated. A vertical reference line perpendicular to a horizontal line made by application of the representative degree of ${\angle}$AFH/CFH in Group I to AFH line in Group II had the most highest coincidence with ENaP-line of Group II, however, its agreement was 42% in male and 47% in female. From this results, the rest of them should be determined their corrective jaw position definitely depend on

Open Reduction of Mandibular Condyle Fracture Via Preauricular Approach (전이개 접근을 이용한 하악 과두 골절의 정복)

  • Kim, Bum-Joon;Cha, Yong-Hoon;Lim, Jae-Hyung;Park, Kwang-Ho;Huh, Jong-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.521-528
    • /
    • 2010
  • Purpose: Anatomical reduction of the fractured condylar process is an important prerequisite for re-establishing function. The authors reported about effectiveness of transoral approach for mandibular subcondyle fracture using trochar device in cases that the fracture line is below the reference line, the perpendicular line of the longitudinal axis of condylar process passing the lowest point of sigmoid notch. As a serial study, we report the open reduction via preauricular approach for mandibular condyle fracture, in cases that the fracture line is above the reference line. Patients and Methods: Sixteen condylar fractures of 15 adult patients were divided two groups and treated by open reduction via preauricular approach (8 cases) or by closed reduction (8 cases). The degree of maximal mouth opening, occlusion, anatomical reduction, condylar resorption and complications were assessed and evaluated for the two groups. Results: The open reduction of condyle via preauricular approach leads to good results without permanent complications. Anatomical reduction of open reduction group and maximal mouth opening range of the closed reduction group is significantly better than the other group. No significant differences were found in the condylar resorption and the occlusion. Conclusion: The preauricular approach was useful to reduce and fix the condylar fragment, in cases that the fracture line is above the reference line.

Prediction of Electrical Characteristics for MIS transmission line using FDTD Simulations (FDTD 수치해석에 의한 MIS transmission line의 전기적 특성 예측)

  • 이준호;남승기;정지채
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.373-376
    • /
    • 2000
  • Coplanar-type MIS transmission lines have been simulated using FDTD method and compared with the measured results and the simulated results of the reference paper[3]. We can confirm that our simulation results are similar to measured results compared to the previous simulated results of the reference paper. Moreover, variations of characteristic impedance by insulator thickness are calculated for the insulator thickness of 0.0,0.5 and 1.0$\mu\textrm{m}$.

  • PDF

Single-row Routing Algorithm with Between Node Congestion (간노드과잉을 고려한 단층 열 라우팅 알고리즘)

  • 이남일;이상조
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.603-609
    • /
    • 1987
  • In this paper, the single-row routing algorithm for munimizing the street congestion and reducing the between node congestion is deviced. To reduce the between node congestion, reference line crossing is defined and used. Reducing the number of total reference line crossing means reducing the total length which help reduce the power consumption of the integrated system and reducing the between node congestin which help reduce the wiring area. This algorithm has been implemented and tested with various example, then produced good results.

  • PDF