• Title/Summary/Keyword: reference implant

Search Result 97, Processing Time 0.022 seconds

Nitric Oxide on the MMP-2 expression by human gingival fibroblasts (치은섬유아세포의 MMP 발현에 대한 Nitric Oxide의 영향)

  • Shin, In-Sik;Yoon, Sang-Oh;Chung, Hyun-Ju;Koh, Jung-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.2
    • /
    • pp.277-288
    • /
    • 2003
  • It has been suggested that increased number and activity of phagocytes in periodontitis lesion results in a high degree of reactive oxygen species (ROS) such as superoxide anion, hydrogen peroxide, nitric oxide and peroxynitrite. There are few reports on the relationship between ROS and MMPs expressions in gingival fibroblast. We studied to elucidate whether and how ROS, especially nitric oxide affects the MMP expression. Human gingival fibroblasts and HTl080 cells (human fibrosarcoma sell line as reference) were grown in DMEM supplemented with 10 mM HEPES, 50 mg/L gentamicin, and 10% heat inactivated fetal bovine serum with addition of various reactive oxygen species (ROS). Culture media conditioned by cells were examined by gelatin zymography. HT1080 cells expressed proMMP-2 and proMMP-9, but human gingival fibroblasts (HGF) produced only proMMP-2. Hydrogen peroxide upregulated MMP-9 expression in HT1080 cells, whereas in human gingival fibroblast SNP treatment showed marked increase in MMP-2 level compared to other ROS. These results suggest that the effects of ROS on MMPs expressions are cell-type specific. RT-PCR for MMP-2 and TIMP-2 m-RNA were performed using total RNA from cultured cells under the influence various kinase inhibitors. In HT1080 cells, treatment with FPTI III (Ras processing inhibitor) and LY294002 (PI3-kinase inhibitor) resulted in inhibition of MMP-2 and MMP-9 expressions, suggesting that Ras/P13-kinase pathway is important for MMPs expression in HT1080 cells. In gingival fibroblasts, treatment with FPTI III and PDTC (NF-kB inhibitor) showed marked decrease in MMP-2 regardless of the of SNP , suggesting that Ras/NF-kB could be the key pathway for NO-induced MMP-2 expression in gingival fibroblasts. This study showed that ROS, especially nitric oxide, could be the critical mediator of periodontal disease progression through control of MMP-2 expression in gingival fibroblasts possibly via Ras/NF-kB pathway.

CELLULAR RESPONSES ON ANODIZED TITANIUM DISCS COATED WITH $1{\alpha}$,25-DIHYDROXYVITAMIN D3 INCORPORATED POLY (D,L-LACTIDE-CO-GLYCOLIDE) (PLGA) NANOPARTICLES

  • Cho, Young-Jin;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.620-627
    • /
    • 2008
  • STATEMENT OF PROBLEM: A biochemical approach for surface modification has offered an alternative for physicochemical and morphological methods to obtain desirable bone-implant interfaces. PURPOSE: The purpose of the present study was to investigate cell responses to poly (D,L-lactide-co-glycolide) (PLGA)/$1{\alpha}$,25-(OH)$_2D_3$ coating with reference to cellular proliferation and differentiation in vitro. MATERIAL AND METHODS: 96 titanium discs were fabricated and divided into four groups. Group 1 was anodized under 300 V as control. Group 2, 3 and 4 were anodized then coated with 3 ml PLGA/$1{\alpha}$,25-(OH)$_2D_3$ solutions. Amount of the solutions were 2 ul, 20 ul and 200ul respectively. The osteoblast-like Human Osteogenic Sarcoma (HOS) cells were seeded and cultured for 1, 3 and 7 days. MTSbased cell proliferation assay and ALPase activity test were carried out. RESULTS: PLGA nanoparticles were observed as fine, smooth and round and HOS cells attached to the anodized surfaces through strand-like and sheet-like filopodia. After 3 days of culture, the dendritic filopodia were exaggerated and sheet-like cytoplasmic projections covered the coated titanium surfaces. After 3 days of culture, all of the groups showed increased cellular proliferation and the lowest proliferation rate was measured on group 2. Higher amount of incorporated $1{\alpha}$,25-(OH)$_2D_3$ (Group 3 and 4) improved cellular proliferation but the differences were not significant statistically (P > .05). But they increased the rate of ALP activities than the control group at day 3 (P < .05). CONCLUSION: Biodegradable PLGA nanoparticles incorporated with vitamin D metabolite positively affected proliferation and differentiation of cells on the anodized titanium surface.

A comparative study of periodontal conditions around mesially tipped molars by a tipping degree (대구치의 근심 경사 정도에 따른 치주 상태의 비교 연구)

  • Park, So-Young;Choi, Seoung-Hwan;Lee, Su-Jeong;Chang, Moon-Taek;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.41-49
    • /
    • 2002
  • The aim of this study was to compare periodontal conditions around mesially tipped molars by a tipping degree. Patients who had been consecutively treated at the Department of Periodontology, Chonbuk National University Hospital from October 1999 to August 2001 were assessed with radiographs taken at their molar regions. Of all molars investigated, 142 molars of 116 patients tipped mesially more than 10 degrees to the line perpendicular to an occlusal plane were selected for the study. The tipped molars were divided into 2 groups with a reference to a tipping degree, i.e., 66 slightly tipped(group 1 : <$30^{\circ}$) and 76 severely tipped molars (group 2 : ${\geq}30^{\circ}$). Probing depth(PD), plaque retention index(PRI) at mesial surfaces of tipped molars and tooth mobility(TM) were recorded at the clinical examination. Tipping degree(TD) and alveolar bony defect(ABD) at the mesial surface of the molars were measured in a radiograph. The results showed that no statistical differences were found between groups in all measured variables. In Pearson correlation analysis performed in the same group, a positive relationship was shown between PRI and PD in the group 1 and, in the group 2, between PRI and PD as well as PRI and ABD(p < 0.01). However, no statistically significant relationship was found between TD and all other variables in both groups. Within limitations of this study, it may be concluded that tipping degree did not seem to influence periodontal conditions, i.e., PD, ABD and TM of mesially tipped molars per se, but plaque presence/absence seemed to mainly affect the periodontal conditions of the tipped molars.

EFFECTS OF SURFACE ROUGHNESS AND MULTILAYER COATING ON THE CORROSION RESISTANCE OF Ti-6Al-4V ALLOY

  • Ko, Yeong-Mu;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.134-135
    • /
    • 2003
  • The dental implant materials required good mechanical properties, such as fatigue strength, combined with a high resistance to corrosion. For increasing fatigue resistance and delaying onset of stress corrosion cracking, shot peening has been used for > 50 years to extend service life of metal components. However, there is no information on the electrochemical behavior of shot peened and hydroxyapatite(HA) coated Ti-6Al-4V alloys. To increase fatigue strength, good corrosion resistance, and biocompatibility, the electrochemical characteristics of Ti/TiN/HA coated and shot peened Ti-6Al-4V alloys by electron beam physical vapor deposition(EB-PVD) have been researched by various electrochemical method in 0.9%NaCl. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. The produced materials were quenched at 1000$^{\circ}C$ under high purity dried Ar atmosphere and were hold at 500$^{\circ}C$ for 2 hrs to achieve the fatigue strength(1140㎫) of materials. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. Shot peening(SP) and sand blasting treatment was carried out for 1, 5, and 10min. On the surface of Ti-6Al-4V alloys using the steel balls of 0.5mm and alumina sand of 40$\mu\textrm{m}$ size. Ti/TiN/HA multilayer coatings were carried out by using electron-beam deposition method(EB-PVD) as shown Fig. 1. Bulk Ti, powder TiN and hydroxyapatite were used as the source of the deposition materials. Electrons were accelerated by high voltage of 4.2kV with 80 - 120mA on the deposition materials at 350$^{\circ}C$ in 2.0 X 10-6 torr vacuum. Ti/TiN/HA multilayer coated surfaces and layers were investigated by SEM and XRD. A saturated calomel electrode as a reference electrode, and high density carbon electrode as a counter electrode, were set according to ASTM GS-87. The potentials were controlled at a scan rate of 100 mV/min. by a potentiostat (EG&G Co.273A) connected to a computer system. Electrochemical tests were used to investigate the electrochemical characteristics of Ti/TiN/HA coated and shot peened materials in 0.9% NaCl solution at 36.5$^{\circ}C$. After each electrochemical measurement, the corrosion surface of each sample was investigated by SEM.

  • PDF

Evaluation of Electric Pulp Test (EPT) as a Tool for Measurement of Dentinal Hypersensitivity (상아질 지각과민 측정 도구로서의 전기치수검사에 대한 평가)

  • Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.371-378
    • /
    • 2002
  • In this study, 40 hypersensitive teeth of 19 patients were investigated. The procedures performed were as follows: Before desensitization, EPT at occlusal third of buccal surface was done for the evaluation of pulp vitality and the EPT value was recorded for the reference value. And mechanical and thermal test was executed for the test of hypersensitivity. If the tooth responded to the above tests, we did EPT at the exposed surface, using toothpaste as a electrolite medium and recorded the EPT value at patient's response. After the tests had been done, desensitization procedures with Gluma(R) Desensitizer were performed according to the manufacturer's instructions. After desensitization, the same tests except EPT at occlusal third were repeated. All the 40 teeth responded positive before desensitization and negative after desensitization procedures. The EPT value at occlusal third ranged from 31 to 65 (48.9${\pm}$7.2). Before desensitization 34 teeth responded at EPT value of 2 and the remaining 6 teeth was in the range of 17 to 25. After desensitization all 40 teeth responded from 12 to 27 (19.6${\pm}$3.5). The 6 teeth responded at greater number than 2 before desensitization was in the range of 18 to 23. Within the limitations of this study we can conclude that: When a tooth with dentinal hypersensitivity responds to mechanical and thermal stimulation, the tooth shows very low resistance to electricity at the exposed surface while when a tooth is desensitized and doesn't show respond to mechanical and thermal stimuli, the tooth shows increased level of resistance to electric stimulation at the exposed surface. EPT can be used for the diagnosis of dentinal hypersensitivity. Furthermore EPT will be useful to evaluate the outcome of desensitization procedures. However, EPT is not a valid tool for measuring dentinal hypersensitivity.

A Survey on Preliminary Dental Hygienists' Senses of Employment (예비치과위생사의 취업에 관한 의식 조사)

  • Han, Su-Jin;Lee, Sun-Mi;Lim, Mi-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.4
    • /
    • pp.583-594
    • /
    • 2007
  • The purpose of this study was to conduct a survey on the senses that preliminary dental hygienists have on employment, who applied for the National Dental Hygienist Examination, so that it could provide a basic reference required for fostering good human resources specializing in oral health with a sense of mission and responsibility as professional. To meet these goals, a self-administered questionnaire survey was conducted for participants in a refresher education meeting for preliminary dental hygienists across three major regions(Seoul, Daejeon and Busan), which was held by the Korean Dental Hygienists Association(KDHA) on Jan. 15, 2006. Total 289 sheets of questionnaire were collected, and 262 sheets except invalid or incomplete ones were used for examination and analysis. As a result, this study came to the following conclusions: First, it was found that 40.4% respondents wanted to be employed in dental clinic or hospital. Most respondents(90.1%) answered that faithfulness is most valued as prerequisite qualification for employment in hospital, and highest percentage of respondents(39.3%) wanted to earn 16 to 17 million Korean won annually. For internship opportunities, 61.9% respondents replied that they could willingly accept the internship, provided that basic pay and switchover to regular employee are all assured. Second, as the results of survey on employment circumstances around respondents, it was found that most respondents(58.3%) were employed in dental clinic or hospital, and highest percentage of respondents(35.0%) earned 15 to 16 million Korean won. Third, it was found that interpersonal relationships among employees had most significant effects(4.81) on selection of employment, which was followed by in-house welfare benefits 1(monthly/annual vacation, resting room, etc; 4.56). For possible influential factors on the selection of employment depending on whether employed or not, it was found that there were Significant differences in pay, welfare benefit 2(seminar, orientation, refresher training opportunities, etc), post-wedding continued employment and merit system between employees and non-employees(pE0.05). Fourth, the survey on respondents' occupational senses of dental hygienist showed that major tasks of dental hygienists were represented by oral disease prevention(92.6%), case management(71.5%), oral health education(66.3%), hospital/clinic management and dental management support(10.4%) and public oral health activities(6.7%) respectively. For job satisfaction, it was found that almost half respondents(48.9%) showed satisfaction at their job and 32.6% felt satisfied at and proud of their job. That is, majority of respondents(81.5%) felt satisfied at their job as dental hygienist. For follow-up requirements to qualify for dental hygienists, it was found that 73.3% felt it necessary to give more investments to self-development, 62.2% respondents considered protection of membership's rights as one of future assignments that KDHA should be more committed to. For future social awareness about dental hygienists as occupation, 69.2% respondents expected that they would be better developed and treated as professional. And desired training courses as a part of qualification for professional dental hygienists were represented by case management(services, manners, etc; 33.3%), implant(28.9%), esthetics(correction, prosthesis, whitening; 18.9%) and so on. For an item on working years, it was noted that 75.9% respondents would keep working as dental hygienists as long as they could.

  • PDF

Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction (Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구)

  • So, Sung-Soo;Noh, Hyeun-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Kee-Deog;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.