• Title/Summary/Keyword: reference equation

Search Result 539, Processing Time 0.034 seconds

A proposal of spirometry reference equations for Korean workers

  • Yonglim Won;Hwa-Yeon Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • v.34
    • /
    • pp.14.1-14.14
    • /
    • 2022
  • Background: Although spirometry results can be interpreted differently depending on the reference equation used, there are no established criteria for selecting reference equations as part of the special health examinations for Korean workers. Thus, it is essential to examine the current use of reference equations in Korea, quantify their impact on result interpretation, and propose reference equations suitable for Korean workers, while also considering the environmental conditions of special health examination facilities. Methods: The 213,640 results from the special health examination database were analyzed to identify changes in the ratio of measured values to reference values of lung capacity in Korean workers with changes in age or height, and changes in the agreement of interpretations with the reference equation used. Data from 238 organizations that participated in the 2018-2019 quality control assessment by the Korea Occupational Safety and Health Agency were used to identify the spirometer model and reference equations used in each special health examination facility. Results: Korean special health examination facilities used six reference equations, and the rate of normal or abnormal ventilatory diagnoses varied with the reference equation used. The prediction curve of the Global Lung Function Initiative 2012-Northeast Asian (GLI2012) equation most resembled that of the normal group, but the spirometry model most commonly used by examination facilities was not compliant with the GLI2012 equation. With a scaling factor of 0.95 applied to the Dr. Choi equation, the agreement with the GLI2012 equation was > 0.81 for men and women. Conclusions: We propose the GLI2012 equation as reference equation for spirometry in Korean workers. The GLI2012 equation exhibited the most suitable prediction curve against the normal lung function group. For devices that cannot use the GLI2012 equation, we recommend applying a scaling factor of 0.95 to the Dr. Choi equation.

Assessment of Reference Evapotranspiration Equations for Missing and Estimated Weather Data (기상자료의 결측과 산정에 따른 기준작물 증발산량 공식의 비교 평가)

  • Yoon, Pu Reun;Choi, Jin-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.3
    • /
    • pp.15-25
    • /
    • 2018
  • Estimating the reference evapotranspiration is an important factor to consider in irrigation system design and agricultural water use. However, there is a limitation in using the FAO Penman-Monteith (FAO P-M) equation, which requires various meteorological data. The purpose of this study is to compare three reference evapotranspiration (ETo) equations in the case of meteorological data missing for 11 study weather stations. Firstly, the FAO P-M equation is used for reference potential evapotranspiration estimation with the actual solar radiation data $R_n$ and the actual vapor pressure $e_a$. Then, in the case of $R_n$, and $e_a$ are missed, the reference evapotranspirations applying FAO P-M, Priestley-Taylor (P-T), Hargreaves (HG) equation were calculated using other meteorological factors. Secondly, MAE, RMSE, $R^2$ were calculated to compare ETo relationship from the ETo equations. From the results, ETo with Hargreaves equation in coastal areas and the Priestley-Taylor equation in the inland areas showed relatively high correlation with FAO P-M when $e_a$ data is missed. In the case of $R_n$ data is missed or two weather data, $e_a$, and $R_n$ data are all missed, $R^2$ value in Priestley-Taylor equation was highest in coastal areas, and $R^2$ values in Hargreaves equation were the high values for 7 inland areas. The results of sensitivity analysis showed that net radiation was the most sensitive for P-T and HG equation, and for FAO P-M, the most sensitive factor was net radiation and relative humidity, air temperature and wind speed were follows. Therefore, in considering of the accessibility to the coast, the types of the missing wether data, and the correlation and the magnitude of error, the reference evapotranspiration equations would be selected in sense of different conditions.

Engineering J-Integral Estimation for Internal Axial Surface Cracks in Cylinders (II) -Optimised Reference Stress Based Estimation- (실린더에 존재하는 축방향 표면균열에 대한 공학적 J-적분식 (II) - 최적참조응력에 기초한 방법-)

  • Kim, Jin-Su;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2442-2449
    • /
    • 2002
  • This paper provides an reference stress based J estimation equation fur cylinders with finite internal axial surface cracks under internal pressure. In part 1, the J estimation equation based on deformation plasticity using Ramberg-Osgood (R-0) materials is proposed. In this paper, the developed CE/EPRI -type solutions ale then re-formulated based on the reference stress concept. Such a re-formulation provides a simpler equation for J. estimation are then further extended to combined internal pressure and bending. The proposed reference stress based J estimation equation is compared with elastic-plastic 3-D FE results using actual stress-strain data for a Type 304 stainless steel. Good agreement between the FE results and the proposed reference stress based J estimations provides confidence in the use of the proposed method to elastic -plastic fracture mechanics of pressurised piping.

Changes of Pulmonary Disability Grades according to the Spirometry Reference Equations (폐기능 예측식에 따른 폐환기능 장해도 변화)

  • Lee, Joung-Oh;Choi, Byung-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.2
    • /
    • pp.108-114
    • /
    • 2010
  • Background: The aim was to estimate the differences between pulmonary disability grades according to the spirometry reference equations (the Korean equation and the Morris equation). Methods: Spirometry was performed on 16,916 male and 1,353 female special examination for pneumoconiosis, in the period of 2007~2009. Changes in predictive values for forced expiratory volume in one second ($FEV_1$), forced vital capacity (FVC) and $FEV_1$/FVC and in disability grade were evaluated using both equations. Results: Mean FVCs for men and women were 4,218.7 mL and 2,801.5 mL in predictive values after the application of the Korean equation, and 3,763.9 mL and 2,395.6 mL after the Morris equation, respectively. Compared with the Morris equation, the Korean equation showed 10.8% and 14.5% of excesses for men and women (p<0.001). Mean $FEV_1s$ for men and women were 3,102.5 mL and 2,107.1 mL in the Korean equation, and 2,667.8 mL and 1,699.6 mL in the Morris equation, respectively. Compared with the Morris equation, the Korean equation showed 14.0% and 19.3% of excesses for men and women (p<0.001). Men and women who showed the changes of disability grades using the Korean equation in place of the Morris equation were 23.9% (4,052/16,916) and 22.9% (311/1,353) on FVC, and 23.1% (3,913/16,916) and 10.7% (145/1,353) on $FEV_1$. Conclusion: Applying different reference equations for spirometry has resulted in changes for disability grades in special examination for pneumoconiosis.

Non-Linear Fracture Mechanics Analyses for Axial Semi-Elliptical Surface Cracked Pipes (배관 내 축방향 반타원 표면균열에 대한 비선형 파괴역학 해석)

  • Kim, Jin-Su;Kim, Yun-Jae;Kim, Young-Jin
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.143-148
    • /
    • 2003
  • This paper provides two types of engineering J estimation equations for cylinders with finite internal axial surface cracks under internal pressure. The first type is the so-called GE/EPRI type J estimation equation based on Ramberg-Osgood materials. Based on detailed 3-D FE results the GE/EPRI-type J estimation equation along the crack front is proposed and validated for Ramberg-Osgood materials. For more general application, the developed GE/EPRI-type solutions are then re-formulated based on the reference stress concept. The proposed reference stress based J estimation equation has good agreement between the FE results and the proposed reference stress based J estimation provides confidence in the use of the proposed method for elastic-plastic fracture mechanics of pressurised piping

  • PDF

Parameter Regionalization of Hargreaves Equation Based on Climatological Characteristics in Korea (우리나라 기후특성을 고려한 Hargreaves 공식의 매개변수 지역화)

  • Moon, Jang Won;Jung, Chung Gil;Lee, Dong Ryul
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.9
    • /
    • pp.933-946
    • /
    • 2013
  • The quantitative analysis of evapotranspiration (ET) is a key component in hydrological studies and the establishment of water resources planning. Generally, the quantitative analysis of ET is performed by the estimation method of potential or reference ET based on meteorological factors such as air temperature, wind speed, etc. Hargreaves equation is one of empirical methods for reference ET using air temperature data. In this study, in order to estimate more exact reference ET considering climatological characteristics in Korea, parameter regionalization of Hargreaves equation is carried out. Firstly, modified Hargreaves equation is presented after the analysis of the relationship between solar radiation and temperature. Secondly, parameter ($K_{ET}$) optimization of Hargreaves equation is performed using Penman-Monteith method and modified equation at 71 weather stations. Lastly, the equation for calculating $K_{ET}$ using temperature data is proposed and verified. As a result, reference ET from original Hargreaves equation is overestimated or underestimated compared with Penman-Monteith method. But modified equation in this study is more accurate in the climatic conditions of Korea. In addition, the applicability of the equation between $K_{ET}$ and temperature is confirmed.

Creep Analysis of Type 316LN Stainless Steel Using Reference Stress (참조응력을 이용한 316LN 스테인리스강의 크리프 해석)

  • Kim, Woo-Gon;Ryu, Woo-Seog
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.10
    • /
    • pp.2122-2129
    • /
    • 2002
  • Creep damage using a reference stress(RS) was analyzed for type 316LN stainless steel. The generalized K-R equation was reconstructed into the RS equation using a critical stress value $\sigma$. The RS equation was derived from the critical stress in failure time $t_f$ instead of material damage parameter $\omega$, which indicates the critical condition of collapse or approach to gross instability of materials during creep. For obtaining the reference stress, a series of creep tests and tensile tests were conducted with at 55$0^{\circ}C$ and $600^{\circ}C$. The stress-time data obtained from creep tests were applied to the RS equations to characterize the creep damage of type 316LN stainless steel. The value of creep constant r with stress levels was about 18 at 55$0^{\circ}C$ and 21 at $600^{\circ}C$. This value was almost similar with r = 24 in the K-R equation, which was obtained by using damage parameter $\omega$. Relationship plots of creep failure strain and life fraction $(t_f /t_r)$ were also obtained with different λ values. The RS equation was therefore more convenient than the generalized K-R equation, because the measuring process to quantify the damage parameter $\omega$ such as voids or micro cracks in crept materials was omitted. The RS method can be easily used by designers and plant operator as a creep design tool.

Calibration of the Hargreaves Equation for the Reference Evapotranspiration Estimation on a Nation-Wide Scale (우리나라 기준 증발산량 산정을 위한 Hargreaves 계수 산정)

  • Lee, Khil-Ha;Park, Jae-Hyeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6B
    • /
    • pp.675-681
    • /
    • 2008
  • In this study, the daily-based reference evapotranspiration was evaluated with Hargreaves equation at the 23 meteorological stations for the time period of 1997-2006. The Hargreaves coefficient was self-calibrated to give the best fit with Penman-Monteith evapotranspiration, being regarded as a reference. On the basis of the estimated parameter set, a generalized regression was conducted to estimate the Hargreaves evapotranspiration by just using temperature data. This study will contribute to water resources planning, irrigation schedule, and environmental management.

Clinical Usefulness and the Accuracy of Korean Reference Equation for Diffusing Capacity (한국인 폐확산능 정상예측식의 임상적 유용성과 정확성)

  • Ra, Seung Won;Park, Tai Sun;Hong, Yoonki;Hong, Sang-Bum;Shim, Tae Sun;Lim, Chae-Man;Lee, Sang-Do;Koh, Younsuck;Kim, Woo Sung;Kim, Dong-Soon;Kim, Won Dong;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Background: Park et al. developed the Korean reference equation for the measurement of diffusing capacity in 1985. However, the equation has not been widely used in Korea and foreign reference equations have been popularly used. We intended to compare the clinical usefulness and the accuracy of the the Korean reference equation (Park's equation) with that of the foreign equation (Burrows' equation) that is commonly used in Korea. Methods: 1. Evaluation of clinical usefulness; Among 1,584 patients who underwent diffusing capacity ($D_LCO$) at the Asan Medical Center from July to December 2006, group A subjects included 276 patients who had different interpretations of $D_LCO$ in trials employing Burrows' equation and Park's equation. Clinical assessment was decided by consensus of two respiratory physicians. In order to evaluate the clinical usefulness of Burrows' equation and Park's equation, agreement of clinical assessment and $D_LCO$ interpretation were measured. 2. Evaluation of accuracy; Group B subjects were 81 patients with interstitial lung disease (ILD) and 39 normal subjects. The 81 ILD patients were diagnosed following a surgical lung biopsy. The accuracy of diagnosing ILD as well as sensitivity and specificity were evaluated according to the use of the reference equations (Burrows' equation and Park's equation) for $D_LCO$. Results: Agreement between clinical assessment and interpretation of $D_LCO$ was 22% for the use of Burrows' equation and 78% for the use of Park's equation. The sensitivity and specificity of the Burrows' equation for diagnosing ILD were 64.2% and 100%. The sensitivity and specificity of the Park's equation for diagnosing ILD were 90.1% and 100%. The sensitivity of the Park's equation for diagnosing ILD was significantly higher than that of Burrows' equation (p<0.001). Conclusion: The Korean reference equation (Park's equation) was more clinically useful and had higher sensitivity for diagnosing ILD than the foreign reference equation (Burrows' equation).

Accuracy of dietary reference intake predictive equation for estimated energy requirements in female tennis athletes and non-athlete college students: comparison with the doubly labeled water method

  • Ndahimana, Didace;Lee, Sun-Hee;Kim, Ye-Jin;Son, Hee-Ryoung;Ishikawa-Takata, Kazuko;Park, Jonghoon;Kim, Eun-Kyung
    • Nutrition Research and Practice
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2017
  • BACKGROUND/OBJECTIVES: The purpose of this study was to assess the accuracy of a dietary reference intake (DRI) predictive equation for estimated energy requirements (EER) in female college tennis athletes and non-athlete students using doubly labeled water (DLW) as a reference method. MATERIALS/METHODS: Fifteen female college students, including eight tennis athletes and seven non-athlete subjects (aged between 19 to 24 years), were involved in the study. Subjects' total energy expenditure (TEE) was measured by the DLW method, and EER were calculated using the DRI predictive equation. The accuracy of this equation was assessed by comparing the EER calculated using the DRI predictive equation ($EER_{DRI}$) and TEE measured by the DLW method ($TEE_{DLW}$) based on calculation of percentage difference mean and percentage of accurate prediction. The agreement between the two methods was assessed by the Bland-Altman method. RESULTS: The percentage difference mean between the methods was -1.1% in athletes and 1.8% in non-athlete subjects, whereas the percentage of accurate prediction was 37.5% and 85.7%, respectively. In the case of athletic subjects, the DRI predictive equation showed a clear bias negatively proportional to the subjects' TEE. CONCLUSIONS: The results from this study suggest that the DRI predictive equation could be used to obtain EER in non-athlete female college students at a group level. However, this equation would be difficult to use in the case of athletes at the group and individual levels. The development of a new and more appropriate equation for the prediction of energy expenditure in athletes is proposed.