• Title/Summary/Keyword: reference ST set

Search Result 18, Processing Time 0.027 seconds

An Algorithm for Classification of ST Shape using Reference ST set and Polynomial Approximation (레퍼런스 ST 셋과 다항식 근사를 이용한 ST 형상 분류 알고리즘)

  • Jeong, Gu-Young;Yu, Kee-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.665-675
    • /
    • 2007
  • The morphological change of ECG is the important diagnostic parameter to finding the malfunction of a heart. Generally ST segment deviation is concerned with myocardial abnormality. The aim of this study is to detect the change of ST in shape using a polynomial approximation method and the reference ST type. The developed algorithm consists of feature point detection, ST level detection and ST shape classification. The detection of QRS complex is accomplished using it's the morphological characteristics such as the steep slope and high amplitude. The developed algorithm detects the ST level change, and then classifies the ST shape type using the polynomial approximation. The algorithm finds the least squares curve for the data between S wave and T wave in ECG. This curve is used for the classification of the ST shapes. ST type is classified by comparing the slopes of the specified points between the reference ST set and the least square curve. Through the result from the developed algorithm, we can know when the ST level change occurs and what the ST shape type is.

Positional Changes of the Internal Reference Points Followed by Reposition of the Maxilla - A Study of a 3D Virtual Surgery Program (상악골 재위치술 시행 시 골편의 이동량에 따른 내측기준점의 변화 - 3차원 가상수술 프로그램을 이용한 연구)

  • Suh, Young-Bin;Park, Jae-Woo;Kwon, Min-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.5
    • /
    • pp.413-419
    • /
    • 2011
  • Purpose: Reposition of the maxilla is a common technique for correction of midfacial deformities. To achieve the goal of the surgery, the maxilla should be repositioned based on the precisely planned position during surgery. The internal reference points (IRPs) and the external reference points (ERPs) are usually used to determine vertical dimension of maxilla, which is an important factor for confirming maxillary position. However, the IRPs are known to be inaccurate in determining the vertical dimension. In this study, we investigated the correlation of positional change of the modified IRPs with repositioned maxilla. Methods: The study group consisted of 26 patients with dentofacial deformities. For the simulation of the surgery, patient maxillary CT data and 3-D virtual surgery programs (V-$Works^{(R)}$ and V-$Surgery^{(R)}$) were used. IRPs of this study were set on both the lateral wall of piriform aperture, inferior margin of both infraorbital foramen, and the labial surfaces of the canine and first molar. The distance from the point on lateral wall of the piriform aperture to the point on the buccal surface of the canine was defined as IRP-C, and the distance from the point on the inferior margin of the infraorbital foramen to the point on the buccal surface of the $1^{st}$ molar was defined as IRP-M. After the virtual simulation of Le Fort I osteotomy, the changes in IRP-C and IRP-M were compared with the maxillary movement. All measures were analyzed statistically. Results: With respect to vertical movements, the IRP-C (approximately 98%) and the IRP-M (approximately 96%) represented the movement of the canine and the $1^{st}$ molar. Regarding rotating movement, the IRPs changed according to the movement of the canine and the $1^{st}$ molar. In particular, the IRP-C was changed in accordance with the canine. Conclusion: IRPs could be good indicators for predicting vertical movements of the maxilla during surgery.

Feedback Burst Loss Ratio Control for Link Performance Improvement in Optical Bur st Switching Networks

  • Linh, To Hoang;Yoon, Gwi-Ok;Nam, Jae-Hyun;Solongo, Ganbold;Hwang, Won-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.9
    • /
    • pp.1067-1076
    • /
    • 2013
  • Known as an important criterion that evaluates performance of future high-speed backbone networks, burst data loss ratio is well-studied in Optical Burst Switching networks. Current literatures mostly focus on reduce burst loss ratio without considering the system stability and link utilization after reducing. In this paper, we propose a novel framework which comes from feedback theoretic to dynamically control burst loss ratio in OBS. The proposed scheme tries to track the pre-set values of burst loss ratio and increases the stability and link utilization degree. The simulation results show that measured burst loss ratio always tracks setup reference with small errors, wavelength channel utilization is increased up to 2% and the system stability is also improved.

Establishment of Reference Range of Proinsulin (Proinsulin 참고치 설정에 관한 연구)

  • Nam, Yee Moon;Shin, Yong Hwan;Kim, Ji Young;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.76-79
    • /
    • 2013
  • Purpose: It is very important to establish the appropriate reference range in the laboratory for preventing mistakes like false positive or false negative. Because the reference range in the laboratory is standard of patient test results interpretation. Proinsulin is precursor hormone of insulin, and the importance is increasing for diagnosing diabetes or insulinoma. Proinsulin reagent used in our laboratory is produced in the USA, and the reference range provided by manufacturer was adapted to our reference range after the validation test. But, it is generally recommend for the every laboratory to establish the their own reference range. So, we decided to re-evaluate the reference range with our patients' test results. Materials and Methods: Among 737 patients who had been to health promotion center in our hospital between Dec. $8^{th}$ 2011 and Dec. $21^{st}$ 2011, 563 patients are chosen with exception of diabetics patients and patients showing abnormal test results in Fasting Glucose, HbA1c, Insulin, and C-peptide. The 563 test results (275 males and 288 females) were classified with three groups(entire, male, female), and analysis of normal distribution was performed with aid of SPSS(version 19.0). Because Each group didn't show normal distribution, the reference range was set from the lowest limit of 2.5% to the highest limit of 97.5% with Percentile method used in non-normal distribution. Results: When evaluation values are sorted in ascending order, the entire range is 4.5~52.0 pM and 5.3~51.9 pM for male and 4.5~52.0 pM for female. The calculated reference range with percentile method shows 6.7~26.5 pM for entire group, 6.8~26.5 pM for male and 6.7~26.5 pM for female, respectively. Conclusion: The reference range provided by reagent manufacturer is 6.4~9.4 pM and the one established in this study is 6.7~26.5 pM. This difference might be caused by racial characteristics between Western people and Koreans. So an ideal reference range can be gotten with normal population visiting to every hospital. Our hospital has been using the newly re-establishing reference range under consultation with the department of endocrinology since Aug. $1^{st}$ 2012.

  • PDF

A Study on the Characteristics of the Spatial Components of Stage - Focused on Domestic Proscenium type of Stage - (공연장 무대공간 구성요소의 특성에 관한 연구 - 국내 프로시니엄 형식의 무대를 중심으로 -)

  • John, Yong-Seok
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.4
    • /
    • pp.68-79
    • /
    • 2016
  • The purpose of this study is to provide a reference for stage space planning in modern theaters by analyzing and understanding stage components in terms of spatial composition, purposes, and correlation between them, and collecting various opinions from stage managers an directors. The findings are as follow: the determination of the size of proscenium arch is crucial, and it needs to be considered not only with the genre of the performance and the number of seats, but also with the size of the stage facility. The two-dimensional size of proscenium arch affects the scale of stage area in three-dimensional way; the size of main stage comes from the width of the arch, and the length of set battens comes from the stage width, and so on. The height of the arch affects the elevation of gridiron, and the height of the building itself ultimately. The number and length of the set battens are directly linked to the size of the winch room, and so is the number of the winches to the Mcc panel room. The 1st level gallery supplying power to lighting equipment needs to be wide enough for staffs to work with various equipments effectively and safely. Degree of practical usage of under-stage machinery turned out to be very low. In order to cut unnecessary waste and cost, the characteristics of the theater must get set first, and experts who know how stage works need to get involved in planning stage.

Establishment of Local Diagnostic Reference Levels of Pediatric Abdominopelvic and Chest CT Examinations Based on the Body Weight and Size in Korea

  • Jae-Yeon Hwang;Young Hun Choi;Hee Mang Yoon;Young Jin Ryu;Hyun Joo Shin;Hyun Gi Kim;So Mi Lee;Sun Kyung You;Ji Eun Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1172-1184
    • /
    • 2021
  • Objective: The purposes of this study were to analyze the radiation doses for pediatric abdominopelvic and chest CT examinations from university hospitals in Korea and to establish the local diagnostic reference levels (DRLs) based on the body weight and size. Materials and Methods: At seven university hospitals in Korea, 2494 CT examinations of patients aged 15 years or younger (1625 abdominopelvic and 869 chest CT examinations) between January and December 2017 were analyzed in this study. CT scans were transferred to commercial automated dose management software for the analysis after being de-identified. DRLs were calculated after grouping the patients according to the body weight and effective diameter. DRLs were set at the 75th percentile of the distribution of each institution's typical values. Results: For body weights of 5, 15, 30, 50, and 80 kg, DRLs (volume CT dose index [CTDIvol]) were 1.4, 2.2, 2.7, 4.0, and 4.7 mGy, respectively, for abdominopelvic CT and 1.2, 1.5, 2.3, 3.7, and 5.8 mGy, respectively, for chest CT. For effective diameters of < 13 cm, 14-16 cm, 17-20 cm, 21-24 cm, and > 24 cm, DRLs (size-specific dose estimates [SSDE]) were 4.1, 5.0, 5.7, 7.1, and 7.2 mGy, respectively, for abdominopelvic CT and 2.8, 4.6, 4.3, 5.3, and 7.5 mGy, respectively, for chest CT. SSDE was greater than CTDIvol in all age groups. Overall, the local DRL was lower than DRLs in previously conducted dose surveys and other countries. Conclusion: Our study set local DRLs in pediatric abdominopelvic and chest CT examinations for the body weight and size. Further research involving more facilities and CT examinations is required to develop national DRLs and update the current DRLs.

A STUDY ON AN INTERPRETATION OF THE ORTHOPANTOMOGRAPH IN THE MIXED DENTITION (Orthopantomograph에 의(依)한 혼합치열상(混合齒列像)의 해석(解析)에 관(關)한 연구(硏究))

  • Kim, Kwang Won
    • The korean journal of orthodontics
    • /
    • v.12 no.2
    • /
    • pp.145-154
    • /
    • 1982
  • Plaster models were constructed and orthopantomographs were taken for 86 male and 70 female primary school pupils, whose upper and lower permanent 4 incisors and 1st molars were completely erupted without crowding; whose deciduous canines and molars were found almost uniformly even without any visible tooth fractures, dental caries or restorations on proximal surfaces of the teeth. Certain reference points on the orthophantomograph were set up and measured and the values were compared with actual or predicted values from the models. The following results were obtained: 1. In regards to available space, the values from the orthopantomograph were greater than the values from the models by a mean of 3.24% on the upper and 10.06% on the lower for males; 3.05% on the upper and 10.01% on the lower for females. 2. In regards to total mesiodistal widths of permanent canine, 1st and 2nd premolars, the values from the orthopantomograph were greater than the presumed values based on the size of lower permanent 4 incisors from the models by a mean of 18.50% on the upper and 24.09% on the lower for males; 14.54 on the upper and 20.51% on the lower for females. 3. Comparing the magnified values of total mesiodistal widths of permanent canine, 1st and 2nd premolars with those of available space, the regression constants of regression equation (Y = a + bX) between them were a=3.2336, b=0.6533 on the upper and a=5.0138, b=0.3290 on the lower for males; a=2.5994, b=0.6521 on the upper and a=3.0113, b=0.6586 on the lower for females. 4. The correlation coefficients between the magnified values of available space and permanent canine, 1st and 2nd premolars were moderately positive as 0.6474 in the upper and 0.505 on the lower for males; 0.6493 on the upper and 0.6183 on the lower for females. 5. In regards to magnified values of the available space from the orthopantomographs there were no significant difference between sexes, (P>0.05) but of the total mesiodistal widths of permanent canine, 1st and 2nd premolars, a significant difference between sexes was found.(p<0.01).

  • PDF

Analysis of Passenger Refuge Model Using EXODUS Refuge Simulator: Case of the Daegu Underground Station Fire (EXODUS 피난시물레이터를 이용한 대구지하역사화재 승객피난모델분석)

  • Lee, Chang-Hyun;Jang, Yong-Jun;Park, Won-Hee;Kim, Dong-Hyeon
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1807-1813
    • /
    • 2007
  • The study aims at analyzing an underground station refuge model using EXODUS, one of the refuge simulation programs. The model for simulation is the Daegu Subway (Joongang-ro station). The details of the accident are referred to as the simulation condition the refuge time of traveling from the $3^{rd}$ basement platform to the $1^{st}$ basement is mainly calculated, with passengers numbering 1,000 including 329 at car 1079, 320 at car 1080, and 360 who are not on board. Reference data is used to set up the position of passengers. CFAST fire simulator is also used, and a fast curve among the $t^2$ growth curves, selected as fire growth scenario. The zone is divided into a total of 24 including 18 at the $3^{rd}$ basement platform and 6 at the $2^{nd}$ basement the $1^{st}$ basement is excluded in the fire simulation, however.

  • PDF

A Prediction Model of Timely Processing on Medical Service using Classification and Regression Tree (분류회귀나무를 이용한 의료서비스 적기처리 예측모형)

  • Lee, Jong-Chan;Jeong, Seung-Woo;Lee, Won-Young
    • Journal of IKEEE
    • /
    • v.20 no.1
    • /
    • pp.16-25
    • /
    • 2016
  • Turnaround time (called, TAT) for imaging test, which is necessary for making a medical diagnosis, is directly related to the patient's waiting time and it is one of the important performance criteria for medical services. In this paper, we measured the TAT from major imaging tests to see it met the reference point set by the medical institutions. Prediction results from the algorithm of classification regression tree (called, CART) showed "clinics", "diagnosis", "modality", "test month" were identified as main factors for timely processing. This study had a contribution in providing means of prevention of the delay on medical services in advance.

Tools for Web-Based Security Management Level Analysis (웹기반 보안 관리 수준 분석 도구)

  • Kim, Jeom-Goo;Choi, Kyong-Ho;Noh, Si-Choon;Lee, Do-Hyeon
    • Convergence Security Journal
    • /
    • v.12 no.3
    • /
    • pp.85-92
    • /
    • 2012
  • Today, the typical web hacking attacks are cross-site scripting(XSS) attacks, injection vulnerabilities, malicious file execution and insecure direct object reference included. Web hacking security systems, access control solutions, access only to the web service and flow inside but do not control the packet. So you have been illegally modified to pass the packet even if the packet is considered as a unnormal packet. The defense system is to fail to appropriate controls. Therefore, in order to ensure a successful web services diagnostic system development is necessary. Web application diagnostic system is real and urgent need and alternative. The diagnostic system development process mu st be carried out step of established diagnostic systems, diagnostic scoping web system vulnerabilities, web application, analysis, security vulnerability assessment and selecting items. And diagnostic system as required by the web system environment using tools, programming languages, interfaces, parameters must be set.