• Title/Summary/Keyword: reduction-scale experiment

Search Result 162, Processing Time 0.026 seconds

The Treatment of Volatile Organic Compounds Using a Pilot-Scale Biofilter (Pilot 규모의 바이오필터를 이용한 휘발성유기화합물질 제거)

  • Son, Hyun-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.245-252
    • /
    • 2004
  • Two biofilter tests were conducted under different operating conditions. Test # 1 was performed to treat VOCs generated from a paint booth. The second test was performed to treat VOCs generated from chemical manufacturing processes. The volume of biofilter media was 4.3 $m^3$. For the test # 1, the biofilter was operated for 30 days with 99.9% reduction ratio. Range of temperature of each stage of the biofilter media was measured between $34^{\circ}C$ and $73^{\circ}C$. All the temperatures of stages reduced gradually after the initial dramatic increase. For the test # 2, the biofilter experiment was conducted for 14 days. In this case, the biofilter was installed outdoor and the experiment was performed during wintertime. Therefore, temperature management for the biofilter was needed. Seven-centimeter thick fiberglass insulation and $150^{\circ}C$ steam heating were used to overcome the outside freezing cold weather during test # 2. Temperature of stage # 5 was measured the highest and that of stage # 1 was the lowest. More acclimation time and test period was needed to determine the maximum loading rate.

Reduction of Hexavalent Chromium by Leachate Microorganisms in a Continuous Suspended Growth Culture (연속배양 체제에서의 침출수 미생물에 의한 6가 크롬이온의 환원)

  • Kim, Hyoun-Young;Oh, Young-Sook;Kim, Yeong-Kwan;Choi, Sung-Chan
    • Korean Journal of Microbiology
    • /
    • v.34 no.3
    • /
    • pp.126-131
    • /
    • 1998
  • Reduction of hexavalent chromium to its trivalent form by leachate microorganisms was studied in batch and bench-scale continuous stirred tank reactor. The inoculum was a culture of microorganisms in leachate and capable of providing up to 90% chromate reduction during 72 h batch assay with $20mg\;Cr(VI)\;L^{-1}$ in minimal media containing different levels of leachate (10 to 60%) and glucose (50 to 200 mM). Addition of glucose increased the efficiency of chromate reduction, but adverse effect was observed with increase of leachate probably due to the competitive inhibition between chromate and sulfate ions. The continuous culture experiment was conducted for 124 days using synthetic feed containing different levels of chromate (5 to $65mg\;L^{-1}$) at room temperature. With a hydraulic retention time of 36 h, chromate reduction efficiency was mostly 100% when Cr(VI) concentrations in the reactor were in the range of 5 to $50mg\;L^{-1}$ Specific rate of Cr(VI) removal was calculated as $3.492mg\;g^{-1}\;protein\;h^{-1}$ during the period of 101~124 days from the start-up which showed 81.2% of average reduction efficiency. The results indicate the potential application of using leachate microorganisms for detoxification of hexavalent chromium in various chromium-contaminated wastewater from landfill or tannery sites.

  • PDF

A Plot Scale Experiment to Assess the NPS Reduction of Sediment Trap for Non-irrigated Cropland (침사구의 밭 비점오염 저감효과 평가를 위한 포장실험 연구)

  • Park, Tae-Yang;Kim, Sung-Jae;Jang, Jeong-Ryeol;Choi, Kang-Won;Kim, Sang-Min
    • Journal of agriculture & life science
    • /
    • v.45 no.5
    • /
    • pp.97-103
    • /
    • 2011
  • The purpose of this study was to analyze the pollutant reduction effect for non-irrigated crop land by nonpoint source pollution control. For a field scale monitoring, 6 plots (5m width and 22m length) and 3 sediment traps were installed. At the outlet of each plot, the stage gauges were installed for runoff monitoring. For a rainfall monitoring, tipping bucket rain gage was installed within the experiment site. Through the artificial irrigation, runoff from the plots were monitored. The SS, TOC, T-N, T-P, COD, NTU of sampled water were analyzed by standard methods. The SS, TOC, T-N, T-P, COD, NTU concentration of initial runoff were 15.00, 1.54, 5.27, 0.07, 4.72, 0.45mg/L, respectively. Four hours later than the initial runoff, the concentration was changed to 1.00, 0.94, 4.06, 0.01, 0.60, 0.33 mg/L, respectively. As a result of artificial irrigation, three out of four sediment traps were filled with runoff water from the experimental plots. One sediment trap was not filled with runoff water because the artificial irrigation was not supplied for two experimental plots. The stage of sediment traps were gradually lowered. However, the water quality didn't showed a decrease trend as the stage went down because the suspended solid was not equally collected during the water sampling.

Reduction Potential for Thermal Load by Extensive Green Roofs (경량형 옥상녹화에 따른 열부하 저감 잠재성 연구)

  • Kim, Yeon Mee;Nam, Mi A;Jang, Dae Hee;Kim, Hyeon Soo;Kim, Hyun Ok
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.67-77
    • /
    • 2013
  • Based on the increasing demand for a solution to reduce thermal load, extensive green roofs have great opportunity for application to existing roofs due to their light-weight and easy maintenance. The present study delivers data regarding thermal behavior and heat reduction potential in relation to vegetation coverage between green roof types. 1) In the hottest hour in a day, green roofs showed considerable potential to mitigate heat load in roof environments, which can be up to $10^{\circ}C$ difference. 2) Compared to conventional cement roofs, the extensive green roofs only have a slight potential to cool the air over green roofs. By statistical analysis of linear regression, green coverage has little to do with the reduction of air temperature; the cooling effect was proven only in nighttime. 3) Green roofs act as an insulating roof membrane, the inner substrate of green roofs remained cooler than cement roof surfaces in the daytime, but in the nighttime the green roofs generally were warmer than the cement roof surfaces. 4) The variable of vegetation coverage resulted in no significant difference in thermal behavior in the air, but had the greatest effect in keeping the substrate cool in the daytime. The high vegetation coverage also hindered the rapid cooling of the substrate in the nighttime, and therefore was warmer than other measured temperatures. In order to draw a clear conclusion to combat urban heat island effect with extensive green roofs, the experiment needs to be applied on a larger scale.

Investigation of Frost Reduction Effect using Mesh Net (그물망을 이용한 서리 저감 효과 구명)

  • Yu, Seok cheol;Kim, Yu yong;Lim, Seong yoon;Song, Ho sung
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.448-455
    • /
    • 2020
  • This study was carried out to investigate reduction of the frost damage using the mesh net used for the purpose of non-bagged cultivation. A device measuring the weight of frost was developed and installed in both the control and the experimental, and the effect of frost reduction was evaluated with their weights. As a result, weight of frost in the control was reduced from 37% to 59% with mesh net on the day the frost was observed. In addition, the device for automatically observing the amount of frost was developed and the height of the windbreak of the frost measuring device was determined to be 30 cm through wind tunnel experiment. The results of this study are expected to reduce frost damage during the flowering season of fruit trees by installing mesh net and it is expected to be used as basic data for agricultural use of mesh net.

Comparison of Fragility Using Natural Frequency and Damping Parameter in System (고유주파수와 감쇠비에 대한 시스템 손상도 비교)

  • Lee, Seok-Min;Jung, Beom-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.48-55
    • /
    • 2018
  • The purpose of the present study is to compare the reduction rate of natural frequency and the increase rate of damping parameter with structural damage in system. For this purpose, experiment and numerical simulation analysis are performed for the 2-span H-Beam with lower natural frequency and higher damping parameter from free vibration in structure. The response signal by impact load before and after damage is analyzed at 14 locations. The response signals for all locations are performed fast fourier transform to estimate the natural frequency reduction rate and wavelet transform to estimate the damping parameter increase rate. The time domain function corresponding to each scale(frequency) is separated from the response signal by wavelet parameter. The estimation of damping parameter increase rate using wavelet transform is more sensitive than the estimation of natural frequency reduction rate in structure.

Image Downscaling Method Optimized for Future Magnification (확대에 최적화 된 영상 축소 방법)

  • Shin, Hyun-Joon;Wee, Young-Cheul
    • Journal of the Korea Computer Graphics Society
    • /
    • v.17 no.1
    • /
    • pp.39-44
    • /
    • 2011
  • In this paper, we introduce a novel method to reduce image to a small size, such that the quality of the image is improved when it is up-scaled. Recent hardwares including cameras and display devices allow us to capture and display high-resolution images. However, it is not always realistic to store and transmit those high-resolution images due to limitation of storage and network bandwidth. Therefore, high-resolution images are often down-scaled to be stored and transmitted, and then up-scaled back for display. To improve final image quality in this scenario, we first formulate selected up-scale methods as linear transformations. The optimal reduction methods are obtained as its inverse transformation. Based on this basic idea, we develop down-scale kernel that is optimized for each up-scale method. In our experiment, the proposed method could improve the quality of the up-scaled image noticeable.

Analysis of Turbidity Reduction Efficiency according to the Configuration of Filter Media in Open-cut River Bed Infiltration Process : Lab Scale Experiment (개착식 하상여과에서 여재 구성에 따른 탁도 저감 효율 분석: Lab Scale 실험을 통한 접근)

  • Yang, Jeong-Seok;Kim, Il-Hwan;Lee, Jae-Beom;Jeong, Jae Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.515-515
    • /
    • 2017
  • 하천에서 취수원을 개발하는데 있어 지층의 구성으로 물리, 화학적 여과, 흡착 등을 통해 자연 정화되는 간접 취수 방식이 활발히 도입되고 있다. 양질의 취수원을 공급할 수 있는 간접 취수 방식은 수량 확보 측면에서의 불확실성과 유지관리상의 어려움 때문에 많은 시행착오가 발생된다. 이와 같은 단점을 개선하기 위해 하상을 개착하여 불균질한 대수층을 치환하고 스크린을 통해 간접 취수원을 개발하는 하상여과 방식이 도입되고 있다. 대수층을 치환하여 여재를 구성함에 있어 오염물질 및 탁도의 저감 효율을 극대화하기 위해 다양한 연구가 진행되고 있다. 본 연구에서는 개착식 하상여과에서 치환하는 여재의 구성에 따른 탁도의 저감 효율을 분석하기 위해 축소 모형실험으로 구성하였다. 각각의 여재의 구성에 대해서는 상수도 시설기준을 통해 축소된 입경의 매질로 구성하였다. 실험실 규모의 모형 수조($1500mm{\times}500mm{\times}1700mm$)를 구성하고 하부에는 내경 80mm이고 길이 1300mm인 기능성 스크린이 부착된 취수관을 설치하였다. 모형 수조에서 여재의 두께는 총 1000mm로 구성하였고, 각각의 층에 대해서는 250mm로 하여 4개의 층을 구성할 수 있도록 하였다. 치환하는 여재의 매질에는 자갈, 왕사, 중사, 화산석을 사용하였고, 각각의 입경은 5-10mm, 2-5mm, 1-2mm, 2-5mm이고, 탁도를 유발하는 물질로는 입경이 $20{\mu}m$인 황토를 사용하였다. 단일매질 구성을 통해 각각의 여재 종류에 따른 탁도 저감 효과에 대해서 분석하였고, 세 가지의 혼합매질 구성을 통해 치환층 여재의 배치에 따른 탁도 저감 효과를 분석하였고, 각각의 구성은 중사-왕사-자갈-화산석, 화산석-중사-왕사-자갈, 중사-왕사-화산석-자갈로 하였다. 주입수는 30-50NTU를 유지하였으며 유출수의 탁도를 통해 저감 효율을 분석하였다. 분석된 결과를 통해 개착식 하상여과 방식의 여재 구성에 대해서 탁도 저감에 효율을 극대화할 수 있을 것으로 보여진다.

  • PDF

Simultaneous Removal of Phenol and Hexavalent Chromium by Rhodococcus sp. CP01 (Rhodococcus sp. CP01에 의한 페놀과 6가 크롬이온의 동시 제거)

  • 최광현;오영숙;김병동;최성찬
    • Korean Journal of Microbiology
    • /
    • v.36 no.4
    • /
    • pp.279-284
    • /
    • 2000
  • Simultaneous reduction of Cr(VI) and degradation of phenol was observed in batch and bench-scale continuous stirred tank reactors using Rhodococcus sp. CP01 isolated from leachate. The strain CP01, which was capable of utilizing phenol as a sole source of carbon and energy, completely reduced added hexavalent chromium (0.25 mM) to its trivalent form during 60 hr batch assay under optimal conditions (pH 7.0 and 1,000 mg/L of phenol concentration). The rates of Cr(VI) reduction and phenol degradation were estimated as 4.17 $\mu$M Cr(VI) and 38.4 mg phenol.$L^{-1}{\cdot}hr^{-1}$, respectively. The continuous culture experiment was conducted for 46 days using synthetic feed containing different levels of chromate (0.0625 to 0.25 mM) and phenol(1,000 to 4,000 mg/L). With a hydraulic retention time of 100 hr, Cr(VI) reduction efficiency was mostly 100% for influent Cr(VI) and phenol concentrations of 0.125 mM and 3,000 mg/L, respectively. During quasi-steady-state operation, specific rate of Cr(VI) reduction was calculated as 0.34 mg Cr(VI).g $protein^{-1}{\cdot}hr^{-1}$ which was comparable to reported values obtained by using glucose as growth substrate. The results suggest the potential application of biological treatment for detoxification of wastewater contaminated simultaneously with Cr(VI) and pheonol.

  • PDF

Effects of the water level reduction and the flow distribution according to change of the side weir location in detention reservoir (홍수조절지 횡월류위어의 위치 변화에 따른 수위 저감 및 유량 분담 효과)

  • Seong, Hoje;Park, Inhwan;Rhee, Dong Sop
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.7
    • /
    • pp.555-564
    • /
    • 2018
  • The detention reservoir is a hydraulic structure that constructs a levee on the inland of river and sets up side weir in a section of the levee, and this facility stores a part of the flood volume in case of a flood event over a certain scale. In order to optimize the operation of detention reservoir, it is necessary to review the linkage with existing facilities in the river. In this study, the effect of water level reduction and the flow distribution was analyzed according to the location of the side weir in the detention reservoir considering the run-of-the-river gate. Two radial gates were installed in the experimental channel, and the water level in channel and the overflow of weir were measured by moving the location of the side weir upstream from the gate. As a results of experiment, it was confirmed that the water level reduction is more remarkable as the location of the side weir was closer to the gate, and the effect of flow distribution is not greatly changed. When two or more side weirs were operated, it is confirmed that the sufficient storage space was secured and the water level reduction effect with the location of the side weir is not large. In addition, the water level reduction rate according to the location of the side weir was estimated by empirical formula and it is provided as basic data that can be used in the planning of the detention reservoir.