• Title/Summary/Keyword: reduction-scale experiment

Search Result 161, Processing Time 0.022 seconds

Study on the Continuous Composting Process to Reduce the Use of Bulking Agent in Pig Slurry (톱밥 절감형 돈분 슬러리 연속 퇴비화 공정 연구)

  • Ryoo, J,.W.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.121-128
    • /
    • 2007
  • To develop the composting system to reduce the use of bulking agent, continuous composting was performed with farmer scale facility, The plant comprises a horizontal pit reactor closed inside a greenhouse and equipped with a turning machine moving on rails. The pit was 9m wide and 50m long and the maximum height of loaded materials was $1.8m^2$. The materials remained in the reactor for 5 months. During the composting process, temperature and water content measured and water balance was evaluated. The reaction temperature of composting was changed $30{\sim}50^{\circ}C$ and high in the middle and low in under composting piles. The moisture contents of the compost were approximately 70% during the experiment. The amount of effluent was 10.6% and $3.16m^3$ of pig slurry per $1m^3$ of bulking agent was treated during continuous composting process. BOD and SS reduction of the effluent in continuous composting was 86.5% and 92.2%, respectively. Indoor relative humidity in night time was changed between 80 and 100%.

  • PDF

Comparison of the Effects of Ultrasound, Laser, Ultrasound-Laser Integration in Patients with Knee Degenerative Osteoarthritis (무릎관절 퇴행성 골관절염 환자에 대한 초음파, 레이저, 초음파-레이저 복합치료의 효과 비교)

  • Jeon, Bom-Su;Kwon, Hyuk-Su;Jeong, Seong-Gwan;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.18 no.1
    • /
    • pp.57-63
    • /
    • 2012
  • Background: The number of old people with degenerative osteoarthritis one of the chronic disease, were constantly increased. Many researchers have made a great effort to verify the effects of ultrasound and laser therapy in degenerative osteoarthritis treatment. This study applied ultrasound-laser integration therapy on knee joint degenerative osteoarthritis and compared its effect with ultrasound and laser. Methods: We assigned 60 patients age 65 to 85 who had been diagnosed as knee joint degenerative osteoarthritis in G nursing home in Daejeon city. Randomization was done in blocks of three, holding twenty people per each group to receive either ultrasound, laser, ultrasound-laser integration therapy. This study carried out the experiment for 6 weeks to from April 17, 2010. We measured variables using visual analog scale (VAS) and pressure threshold meter (PTM) of the effects by before and after exercise. Results: It has been found that VAS was reduced and PTM was increased in all three groups. Compare with the other groups, Ultrasound-laser integration therapy group had lower VAS and higher PTM than ultrasound therapy and laser therapy group. Conclusions: These results lead us to the conclusion that ultrasound-laser integration have influenced the pain reduction of the knee degenerative osteoarthritis.

  • PDF

Assessment of Water Purification Capacity of Vegetation Mats for the Reduction of Nonpoint-Source Pollution Loads (비점오염 부하 저감을 위한 식생 매트의 수질정화능 평가)

  • Song, Kyu Sung;Han, Sang Hun
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.1
    • /
    • pp.70-75
    • /
    • 2016
  • The purpose of this study was to develop water-purification vegetation mats consisting of the eco-friendly materials and to validate their water purification capabilities with the objective of reducing nonpoint pollution into streams. The developed vegetation mats are made of coconut fiber shell and filling consisted of zeolite, diatomaceous earth or a mixture of calcinated foam media. The bench scale assessment of the water purification capability of the three filling materials showed that the removal efficiencies of suspended solid (SS), total nitrogen (T-N) and total phosphorus (T-P) were higher in the foam media than in zeolite or diatomaceous earth. From the results of the field experiment, the removal efficiencies of the vegetation mats filled with the foam media were 60.1% in SS, 32.2% in T-N and 20.2% in T-P. Therefore the vegetation mats filled with the foam media calcinated from zeolite and diatomaceous earth should have higher efficiencies in controlling the nonpoint source pollutions in streams.

Active Window to Reduce the Exterior Noise Flowed Through the Open Window (열린 창문을 통해 유입되는 소음을 저감하는 능동소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.820-827
    • /
    • 2011
  • Recently, noise has been regarded as one of the most notorious and frequent environmental pollutions which can be often encountered not only in the living space but also in the industrial site. Studies on physiological and psychological effects of long-term noise exposure to human being have commanded the public interest on noise issues. Since environmental noises such as traffic noise and construction noise is mainly flowed through the open window, it is necessary to develop the active noise control system to reduce it inside the building. Although control speakers and microphones for the noise signal measurement in the control region are essential for the conventional active noise control methods, it is impossible to implement them in the control region in the building environment because the control region is the living quarter and they may hinder activities of the residents. Therefore, we proposed the active window system to reduce the exterior noise flowed through the open window with microphones installed outside the window and control speakers installed at the frame of the window. To confirm the performance of the proposed active window, we carried out the simulation and experiment using active window system with 8 control speakers. Simulation results showed the noticeable noise reduction effect inside the control region within the frequency range without the spatial aliasing. Experimental result showed that the total acoustic potential energy inside the room of the scale model is reduced to about 10dB within the interest of frequency range.

A Study on Accalerated Vocous Condition in Siphon Spillway (싸이폰식 여수토의 진공촉진에 대한 연구)

  • 김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.6 no.2
    • /
    • pp.816-825
    • /
    • 1964
  • 1. Outline: The flow of the siphon spillway is very intricate and affected by vacuous condition. It is an intresting problem to make vacuum rapidly in_siphon, i.e, to provoke the perfect siphonaoge with the lowest water-level of overflow. The hydraulic experiments of siphon spillway have practiced at the Masan Lake, Haenam, the province of Junnam and gained rational and economical results which cannot be odtained by calculation. 2. Experiment: The model scale was a half of that of the prototype. 3. Results and discussion: In the experiments of 14 runs, washing, overflow water level, outlet, water level of cushion, phenomenon of water flying and water pressure of every part, etc. were studied. a) The relation of overflow water-level at siphon inlet and deflector When the elevation of the deflector is 10. 65m and the form of deflector O.4m long is the hypotenuse of an $45^{\circ}$ isosceles triangle, the over flow water-level is the minimum, i. e. the siphonage was excellent. There is no effect by the rising of overflow water-Ievel between 11.95m to 1O.65m of deflector elevation (in the first plan, it is 11.05m). But the overflow water-level rises remarkably in the outside region of the above limits. b) The relation of overflow water-level, the length of cushion and standard height of the base. The reduction of the length of cushion brings the rising of overflow waterlevel, and the rising of the standard height of the base brings the rising of overflow water level. For the long cushion length and low standard height of the base, it cannot be expeted to have the falling of overflow water-level. The most satisfactory data were obtained at 5.20m of the base standard height and 6.1m of the length of cushion. The first vah,le planned was 5.70 m and 4.30m.

  • PDF

Flutter analysis of Stonecutters Bridge

  • Hui, Michael C.H.;Ding, Q.S.;Xu, Y.L.
    • Wind and Structures
    • /
    • v.9 no.2
    • /
    • pp.125-146
    • /
    • 2006
  • Stonecutters Bridge of Hong Kong is a cable-stayed bridge with two single-column pylons each 298 m high and an aerodynamic twin deck. The total length of the bridge is 1596 m with a main span of 1018 m. The top 118 m of the tower will comprise structural steel and concrete composite while the bottom part will be of reinforced concrete. The bridge deck at the central span will be of steel whilst the side spans will be of concrete. Stonecutters Bridge has adopted a twin-girder deck design with a wide clear separation of 14.3 m between the two longitudinal girders. Although a number of studies have been conducted to investigate the aerodynamic performance of twin-girder deck, the actual real life application of this type of deck is extremely limited. This therefore triggered the need for conducting the present studies, the main objective of which is to investigate the performance of Stonecutters Bridge against flutter at its in-service stage as well as during construction. Based on the flutter derivatives obtained from the 1:80 scale rigid section model experiment, flutter analysis was carried out using 3-D finite element based single parameter searching method developed by the second author of this paper. A total of 6 finite element models of the bridge covering the in-service stage as well as 5 construction stages were established. The dynamic characteristics of the bridge associated with these stages were computed and applied in the analyses. Apart from the critical wind speeds for the onset of flutter, the dominant modes of vibration participating in the flutter vibration were also identified. The results indicate that the bridge will be stable against flutter at its in-service stage as well as during construction at wind speeds much higher than the verification wind speed of 95 m/s (1-minute mean).

Quantitative Assessment on Contributions of Foreign NOx and VOC Emission to Ozone Concentrations over Gwangyang Bay with CMAQ-HDDM Simulations (CMAQ-HDDM을 이용한 광양만 오존 농도의 국외 기여도 분석)

  • Bae, Changhan;Kim, Byeong-Uk;Kim, Hyun Cheol;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.5
    • /
    • pp.708-726
    • /
    • 2018
  • In this study, we examined the contribution of nitrogen oxides and volatile organic compounds emitted from China and Japan to ozone concentrations over Gwangyang-bay, South Korea. We used a chemical transport model, Community Multi-scale Air Quality model, and its instrumented sensitivity tool, High-order Decoupled Direct Method. Intercontinental Chemical Transport Experiment-Phase B 2006 for East Asia and Clean Air Policy Support System 2007 emissions inventories for South Korea were used for the ozone simulation. During the study period, May 2007, the modeled maximum daily 8-hr average ozone concentration among seven air quality monitors in Gwangyang-bay was 68.8 ppb. The contribution of $NO_x$ emissions from China was 19.5 ppb (28%). The highest modeled ozone concentrations and Chinese contributions appeared when air parcels were originated from Shanghai area. The observed 8-hr average ozone concentrations in Gwangyang Bay exceeded the national ambient air quality standard (60 ppb) 203 times by daytime and 56 times by nighttime during the period. It was noticed that many exeedances happened when contribution of Chinese emissions to ozone concentrations over the area increased. Sensitivity analysis shows that a reduction in Chinese $NO_x$ and VOC emissions by 15% could lessen the total exceedance hours by 24%. This result indicates that high ozone concentrations over Gwangyang-bay are strongly enhanced by Chinese emissions.

Active Window system based on Finite Thickness Window Model (유한 두께 창문 모델을 적용한 능동 소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.763-768
    • /
    • 2012
  • Active window system which can reduce the environmental noises, such as traffic noise and construction noise, from an open window into a room was proposed in the previous works. The key idea of the proposed active window system was that the control sources are approximately collocated with the primary noise source in terms of the acoustic power for global noise reduction throughout the interior room. Moreover, because it is important not to intrude into the living space in the building environment, no error sensors were used and an open-loop control method using control sources at the window frame and the reference sensors outside the room was used for the proposed system. The open-loop control gain was calculated by the interior room model assumed as the semi-infinite space, and the interior sound field was estimated by Rayleigh integral equation under the baffled window model assumption. However, windows with a finite thickness should were considered for the calculation of the open-loop control gain of the active window system since these are representative of most window cases. Therefore, the finite thickness window model based on the Sgard's model was derived and the open-loop control gain using the interior sound field estimated by that model was calculated for active window system. To compare the performance of these two models, a scale-model experiment was performed in an anechoic chamber according to noise source directions. Experimental results showed that the performance for the thickness window model is better than the baffled window model as the angle with respect to the perpendicular direction is larger.

  • PDF

An Experimental Study on Size-effect for Characteristic of Flexural Strength of Pavement Concrete (포장 콘크리트의 크기 효과에 따른 휨 강도 특성 분석에 관한 실험적 연구)

  • Lee, Hyeongi;Oh, Hongseob;Sim, Jongsung;Sim, Jaewon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.299-306
    • /
    • 2015
  • The quality for the domestic pavement is evaluated based on flexural strength at the age of 28 days in accordance with KS regulation. Most specimens of the flexural tensile strength used currently are relatively large ones with a dimension of $150{\times}150{\times}550mm$. Accordingly, it is difficult to treat the specimens, and the utilization of a curing tank is low. In this paper, the study tried to resolve the problem by specimen size specified in the code. For this purpose, a flexural strength test was conducted according to the log scale within the specimen size specified by the KS. And, based on the results of this experiment, a comparative analysis was conducted using the prediction formula of Size Effect Law (SEL) proposed by Bazant to examine the correlation between specimen sizes, so as to use the result as basic data for the reduction of the specimen size in the quality evaluation of concrete pavement.

An Experimental Study on Energy Reduction of an Exhaust Air Heat Recovery Type Outdoor Air Conditioning System for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 배기 열회수식 외기공조시스템의 에너지절감에 관한 실험적 연구)

  • Song, Gen-Soo;Yoo, Kyung-Hoon;Kang, Shin-Young;Son, Seung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.5
    • /
    • pp.273-281
    • /
    • 2009
  • In recent semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems represents about 45% of the total air conditioning load required to maintain a clean room environment. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery from the exhaust air is therefore useful for reducing the outdoor air conditioning load for a clean room. In the present work, an energy-efficient outdoor air conditioning system was proposed to reduce the outdoor air conditioning load by utilizing an air washer to recover heat from the exhaust air. The proposed outdoor air conditioning system consisted mainly of a preheating coil, an air washer, two stage cooling coils, a reheating coil, a humidifier and two heat recovery cooling coils inserted into the air washer and connected to a wet scrubber. It was shown from the lab-scale experiment with outdoor air flow of $1,000\;m^3/h$ that the proposed system was more energy-efficient for the summer and winter operations than an outdoor air conditioning system with a simple air washer.