• Title/Summary/Keyword: reduction of fouling

Search Result 135, Processing Time 0.021 seconds

Direct and Indirect Membrane Integrity Tests for Monitoring Microbial Removal by Microfiltration (정밀여과(MF)막 미생물 제거율 모니터링을 위한 막 완전성시험)

  • Hong, Seungkwan;Miller, Frank;Taylor, James
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.801-806
    • /
    • 2004
  • The pilot study was conducted to (i) investigate the ability of various membrane integrity monitoring methods to detect changes in membrane integrity during operation, and (ii) determine the impact of membrane damage on microbial removal by microfiltration. Two variations of air pressure hold tests were investigated for direct integrity monitoring: pressure decay (PD) and diffusive air flow (DAF) tests which are most commonly used integrity tests for microfiltration (MF) membranes. Both PD and DAF tests were sensitive enough to detect one damaged fiber out of 66,000 under field operaing conditions. Indirect integrity monitoring such as turbidity and particle counting, however, responded poorly to defects in membrane systems. Microbial challenge study was performed using both new and deliberately damaged membranes, as well as varying the state of fouling of the membrane. This study demonstrated that MF membrane with nominal pore size $0.2{\mu}m$ was capable of removing various pathogens including coliform, spore, and cryptosporidium, at the level required by drinking water regulations, even when high operating pressures were applied. A sharp decrease in average log reduction value (LRV) was observed when one fiber was damaged, emphasizing the importance of membrane integrity in control of microbial contamination.

A Study on Heat Exchange Efficiency of EGR Cooler for Diesel Engine to Meet Euro-5 Emission Regulation (Euro-5 대응 디젤엔진용 EGR 쿨러의 열교환 효율 연구)

  • Lee, Joon;Han, Chang-Suk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.183-188
    • /
    • 2007
  • Recently, diesel engine has been frequently applied to RV, SUV and light duty truck due to the good fuel economy and high thermal efficiency. $NO_x$ and PM, environmental pollution materials are basically produced in diesel combustion process. The most important target in diesel engine research is the development of system to reduce the emissions of $NO_x$ and PM. Cooled EGR system is an effective method for the reduction of $NO_x$ emission and PM emission from a diesel engine and EGR cooler is the key component of the system. This study investigates the EGR cooler of oval gas tubes compared with the EGR cooler of shell & tubes to verify the heat exchange efficiency of cooler by means of engine dynamometer tests, rig performance tests and numerical analyses.

Recent trends in anaerobic membrane bioreactor treatment of domestic wastewater (혐기성 막 생물반응조를 이용한 하수처리의 최근 동향)

  • Shin, Chung-Heon;Bae, Jae-Ho;Kim, Jeong-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.529-545
    • /
    • 2013
  • With the increasing concern on climate changes and energy shortage, anaerobic membrane bioreactors (AnMBR) become a promising alternative to aerobic processes for domestic wastewater treatment. Two major advantages of AnMBRs are energy production and sludge reduction. Recently, several different configurations of AnMBRs have been proved to produce high quality effluent at reasonable hydraulic retention time and ambient temperature. One of the major problems of the AnMBR is membrane fouling control, and some solutions are already suggested. Other problems to be solved before the full application of the AnMBR are recovery of dissolved methane, management of residual nutrients and sulfide. Considering the potential advantages and future technology development, AnMBR will become major domestic wastewater treatment process in near future.

Physiological effects of biocide on marine bivalve blue mussels in context prevent macrofouling

  • Haque, Md Niamul;Kwon, Sung-Hyun
    • Journal of Ecology and Environment
    • /
    • v.40 no.3
    • /
    • pp.136-143
    • /
    • 2016
  • Background: Mussels are stubborn organisms attached to solid substrata by means of byssus threads. The abundance of marine mussel Mytilus edulis in marine facilities like power stations was reason to select among fouling animals. Methods: Mortality patterns as well as physiological behavior (oxygen consumption, foot activity, and byssus thread production) of two different size groups (14- and 25-mm shell length) of M. edulis were studied at different hydrogen peroxide concentrations ($1-4mg\;l^{-1}$). Results: Studied mussels showed progressive reduction in physiological activities as the hydrogen peroxide concentration increased. Mussel mortality was tested in 30 days exposure, and 14 mm mussels reached the highest percentage of 90% while 25 mm mussels reached 81%. Produced data was echoed by Chick-Watson model extracted equation. Conclusions: This study points that, while it could affect the mussel mortality moderately in its low concentrations, hydrogen peroxide has a strong influence on mussels' physiological activities related to colonization. Therefore, hydrogen peroxide can be an alternative for preventing mussel colonization on facilities of marine environment.

Wettability Simulation of Oil Droplet on Riblet Surface (리블렛 표면에서 유적의 젖음성에 대한 수치 해석)

  • Kim, TaeWan
    • Tribology and Lubricants
    • /
    • v.35 no.2
    • /
    • pp.94-98
    • /
    • 2019
  • The riblet structure like shark skin has been widely studied owing to its drag reduction and anti-fouling properties. In this study we simulated the wettability of an oil droplet on a riblet surface. We developed a numerical analysis method using the Wenzel equation and Cassie-Baxter equation that can estimate the contact angle with a penetrated depth of the droplet on rough surfaces. Riblet surfaces with nine scales composed of five hemi-elliptical ribs are generated numerically. The variation of contact angles with fractional depth of penetration for the generated riblet surfaces with and without coatings is demonstrated in the condition of solid-air-oil and solid-water-oil interfaces. The contact angle for the uncoated surface decreases with increasing fractional depth of penetration more drastically than that for the coated surface. For the effect of surface roughness on the contact angle of the droplet, the oleophilic surface gives lower contact angle when the surface is rougher, whereas the oleoophobic surface gives higher contact angle with higher roughness To verify the analysis results, the wetting angle was measured in the solid-air-oil interface and solid-water-oil interface for the shark-skin template and shark-skin replica. The effects of teflon coating were also evaluated. It is shown that the simulation results cover the experimental ones.

Carbonate scale reduction in reverse osmosis membrane by CO2 in wastewater reclamation

  • Shahid, Muhammad Kashif;Pyo, Minsu;Choi, Young-Gyun
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.125-136
    • /
    • 2017
  • Reverse osmosis technology is being used on large scale for treatment of ground water, brackish water, wastewater and sea water. The most challenging issue in RO process is carbonate scaling which is directly linked with the efficiency and economy. Considering the natural phenomena of carbonate scaling different adaptations have been made to control scaling on the surface of RO membrane including acid dosage and antiscalant addition. As carbonate scaling is directly related with pH level of feed water, present study describes an experimental approach to reduce scaling on RO membrane by lowering the feed water pH by purging $CO_2$. In this comparative study four different conditions including control process (without any scale inhibitor), with dosage of antiscalant, with purging of $CO_2$ and with co addition of antiscalant and $CO_2$ in a feed stream line; it was established that $CO_2$ is a better appliance to reduce carbonate scaling on the membrane surface by reduce pH of feed stream. It was also observed that $CO_2$ and antiscalant mutually function better for scale control.

A Study on the Effect of Non-Clean Water Treatment Chemicals for R-134a Turbo-Chiller Condensers (R-134a 터보냉동기 응축기의 무세정 수처리 약품 효과 연구)

  • JUNG, DA-WOON;KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.437-445
    • /
    • 2022
  • This paper presents an experimental study on the main management factors of the condenser contamination such as fouling and corrosion for the R-134a turbo-chiller to save energy, reduce corrosion rates, and reduce maintenance costs through the application of condenser non-cleaning water treatment chemical. The series of experiment is conducted using combining oxidative microbial sterilizers, non-oxidizing microbial sterilizers, and anti-corrosion agents. The leaving temperature difference and corrosion rates for three different combination of chemicals are collected and analyzed. The experimental results show that the cost reduction (4,066,000 Won/year) of the disinfectant (FT-830) can be achieved by adding the oxidative disinfectant (NaOCl) and the non-oxidizing disinfectant (NX-1116). The LTD value is maintained at 1.9℃, and the corrosion rates of copper and carbon steel specimens are 0.07 mpy and 1.61 mpy, respectively.

Deacidification of Mandarin Orange Juice by Electrodialysis Combined with Ultrafiltration

  • Kang, Yeung-Joo;Rhee, Khee-Choon
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.4
    • /
    • pp.411-416
    • /
    • 2002
  • The effects of electrodialysis (ED) alone or ED plus ultrafiltration (UF) on deacidification of mandarin orange juice were studied by using a commercial ED stack with ion exchange membranes. ED processing, reduced the total acidity of the juices by 30% (0.6~0.7% as total acidity) after 50 min and by about 60~70% (0.23~0.4% as total acidity) after 100 min, as compared to the control juice. However, the acidity reduction after 50 min of ED was determined to be suitable, when considering total acidity (0.6~0.7%, w/w) and current efficiency. There was no color change in the juices following ED, and the pH and Brix were only slightly decreased. Furthermore, ascorbic acid and citric acid concentrations showed only minor decreases, and amino-N, free sugar, and flavonoid contents remained almost unchanged. Therefore, we concluded that the nutritional integrity of the juice was maintained. ED combined with UF may be effective, not only in preventing membrane fouling, but also in preserving the nutrients, such as ascorbic acid, in citrus juice.

Characteristics of Membrane Filtration as a Post Treatment to Anaerobic Digestion (혐기성 소화의 후처리로서 분리막의 여과특성 연구)

  • Choo, Kwang-Ho;Lee, Chung-Hak;Pek, Un-Hwa;Koh, Ui-Chan;Kim, Sang-Won;Koh, Jong-Ho
    • Applied Chemistry for Engineering
    • /
    • v.3 no.4
    • /
    • pp.730-738
    • /
    • 1992
  • Filtration characteristics according to membrane materials were studied In the ultrafiltration of anaerobic digestion broth as a post treatment method. A series of resistances for different membranes were quantitatively assessed on the basis of the resistance-in-series model. Flux behavior observed with the digestion broth was irrelevant to initial water permeabilities of each membrane. The fluoro polymer membrane showed the most significant improvement of flux with increase of cross-flow velocity, which suggests that the cake layer formed on this membrane is more weakly attached to the membrane surface than those on the other membranes. Flux reduction during longtime running was attrib-used to the polarization layer resistance ($R_p$) as well as the fouling layer resistance($R_f$). Continuous increase of $R_p$ may reflect the variation in the characteristics of cake layers, which could result from size, shape, and structure changes due to lysis and growth of biomass. Hydrophilic cellulosic membrane had a much lower fouling tendency than hydrophobic polysulfone membrane. The depressurization method induced a small increase in flux of $5-10L/m^2/h$. During washing and cleaning, filtrability of each membrane was rapidly recovered within 15 minutes until a stationary value was reached.

  • PDF

Design of Dead-end Membrane Module with Increased Permeate Flux by Natural Convection Instability Flow (자연대류 불안정 흐름에 의해 투과량을 증가시킨 전량여과 막모듈의 설계)

  • Kim, Gi-Jun;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.29 no.3
    • /
    • pp.147-154
    • /
    • 2019
  • The permeate flux increments of a natural convection instability flow (NCIF) caused by the change of inclined angles ($0{\sim}180^{\circ}$) to gravity of the commercial membrane module were tested in the dead-end membrane filtration of BSA protein solution. The NCIF are more generated as the inclined angle increased from $0^{\circ}$ to $180^{\circ}$, and the occurred NCIF enhances permeate flux. However, the commercial module can only generate NCIF by completely removing the air gap in module. Since the custom design module designed in this study is permeated in a crossward direction ($90^{\circ}$), NCIF is always generated even if there is the air gap in module. The results of membrane filtration of BSA and dextran solutions using a custom design module showed that the flux in the crossward direction is increased to about 3.8 times for BSA solution and 1.8 times for dextran solution after two hours of operation due to the occurrence of NCIF. Also, NCIF generation is continued during 20 hours filtration of BSA solution, increasing the permeate flux to about 7.5 times. Since the custom design module with a permeation in the crossward direction and NCIF is always generated within the module, so it is possible to expect an increase in permeate flux due to the suppression of fouling formation, and thus to be utilized as a superb dead-end membrane module.