• Title/Summary/Keyword: reduction in area

Search Result 3,828, Processing Time 0.024 seconds

Mapping of Functionally Reduced Potential Area for Improving Utilization of Agricultural Reservoir in Terms of Environmental Planning (환경생태계획 측면에서 농업용저수지 활용성 제고를 위한 기능저하 잠재지역 맵핑 연구)

  • Yeum, Jung-Hun
    • Journal of Environmental Science International
    • /
    • v.28 no.11
    • /
    • pp.1027-1032
    • /
    • 2019
  • This study aimed to analyze the prioritized area for the functional change of agricultural reservoir according to the rapid urbanization and social changes through the mapping method. Changwon-si, Gimhae-si, and Jinju-si in Gyeongnam province were selected as the study area, considering the results of land-use and cluster analysis. As the planning unit of management area, watershed was used and land coverage map from 1975 to 2015 were analyzed for changes of land use. The reduction ratio (%) of farmland was calculated for identifying the changes in 2013 compared to 1975. As a result, the reduction ratio was 11.9% for Changwon-si, 12.2% for Gimhae-si and 9.3% for Jinju-si, and the number of watershed having functionally reduced potential-area was relatively high in the proportion to the city size.

A Study on the Pollutants Reduction of Venturi Type After-burner by oxygen enrichment and Induced Air (산소부화와 유인공기를 이용한 벤츄리형 후연소기의 오염물질 저감에 관한 연구)

  • 오세원;박준홍;이용후;이진석;이도형
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.845-851
    • /
    • 2003
  • The purpose of this experimental study is to investigate the quantitative pollutants reduction by oxygen enrichment and induced air effect in venturi type after-burner. For this purpose, CO, $CO_2$, $O_2$. and HC concentrations were measured before and after the after-burner by changing the Oxygen flow rate and area ratio which is defined as the ratio of air inducing area divided by total area. As results of this study, when the area ratio were increased, the emission reduction effect was increased even less oxygen flow rate. In that case when oxygen was injected too little, the pollutants were increased.

Reduction Behaviors of Nitric Oxides on Copper-decorated Mesoporous Molecular Sieves

  • Cho, Ki-Sook;Kim, Byung-Joo;Kim, Seok;Kim, Sung-Hyun;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.100-103
    • /
    • 2010
  • In this study, NO reduction behaviors of copper-loaded mesoporous molecular sieves (Cu/MCM-41) have been investigated. The Cu loading on MCM-41 surfaces was accomplished by a chemical reduction method with different Cu contents (5, 10, 20, and 40%). $N_2/77$ K adsorption isotherm characteristics, including the specific surface area and pore volume, were studied by BET's equation. NO reduction behaviors were confirmed by a gas chromatography. From the experimental results, the Cu loading amount on MCM-41 led to the increase of NO reduction efficiency in spite of decreasing the specific surface area of catalysts. This result indicates that highly ordered porous structure in the MCM-41 and the presence of active metal particles lead the synergistical NO reduction reactions due to the increase in adsorption energy of MCM-41 surfaces by the Cu particles.

Effect of High Temperature Treatment and Subsequent Oxidation anil Reduction on Powder Property of Simulated Spent Fuel

  • Song, Kun-Woo;Kim, Young-Ho;Kim, Bong-Goo;Lee, Jung-Won;Kim, Han-Soo;Yang, Myung-Seung;Park, Hyun-Soo
    • Nuclear Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.366-372
    • /
    • 1996
  • The simulated spent PWR fuel pellet which is corresponding to the turnup of 33,000 MWD/MTU is prepared by adding 11 fission-product elements to UO$_2$. The simulated spent fuel pellet is treated at 40$0^{\circ}C$ in air (oxidation), at 110$0^{\circ}C$ in air (high-temperature treatment), and at $600^{\circ}C$ in hydrogen (reduction). The product is treated through additional addition and reduction up to 3 cycles. Pellets are completely pulverized by the first oxidation, and the high-temperature treatment causes particle and crystallite to grow and surface to be smooth, and thus particle size significantly increases and surface area decreases. The reduction following the high-temperature treatment decreases much the particle size by means of the formation of intercrystalline cracks. The particle size decreases a little during the second oxidation and reduction cycle and then remains nearly constant during the third and fourth cycles. Surface area of pounder increases progressively with the repetition of oxidation and reduction cycles, mainly due to the formation of Surface cracks. The degradation of surface area resulting from high-temperature treatment is restored by too subsequent resulting oxidation and reduction cycles.

  • PDF

Evaluation of Suitable REDD+ Sites Based on Multiple-Criteria Decision Analysis (MCDA): A Case Study of Myanmar

  • Park, Jeongmook;Sim, Woodam;Lee, Jungsoo
    • Journal of Forest and Environmental Science
    • /
    • v.34 no.6
    • /
    • pp.461-471
    • /
    • 2018
  • In this study, the deforestation and forest degradation areas have been obtained in Myanmar using a land cover lamp (LCM) and a tree cover map (TCM) to get the $CO_2$ potential reduction and the strength of occurrence was evaluated by using the geostatistical technique. By applying a multiple criteria decision-making method to the regions having high strength of occurrence for the $CO_2$ potential reduction for the deforestation and forest degradation areas, the priority was selected for candidate lands for REDD+ project. The areas of deforestation and forest degradation were 609,690ha and 43,515ha each from 2010 to 2015. By township, Mong Kung had the highest among the area of deforestation with 3,069ha while Thlangtlang had the highest in the area of forest degradation with 9,213 ha. The number of $CO_2$ potential reduction hotspot areas among the deforestation areas was 15, taking up the $CO_2$ potential reduction of 192,000 ton in average, which is 6 times higher than that of all target areas. Especially, the township of Hsipaw inside the Shan region had a $CO_2$ potential reduction of about 772,000 tons, the largest reduction potential among the hotpot areas. There were many $CO_2$ potential reduction hot spot areas among the forest degradation area in the eastern part of the target region and has the $CO_2$ potential reduction of 1,164,000 tons, which was 27 times higher than that of the total area. AHP importance analysis showed that the topographic characteristic was 0.41 (0.40 for height from surface, 0.29 for the slope and 0.31 for the distance from water area) while the geographical characteristic was 0.59 (0.56 for the distance from road, 0.56 for the distance from settlement area and 0.19 for the distance from Capital). Yawunghwe, Kalaw, and Hsi Hseng were selected as the preferred locations for the REDD+ candidate region for the deforestation area while Einme, Tiddim, and Falam were selected as the preferred locations for the forest degradation area.

Melting of Ice Inside a Horizontal Cylinder under the Volume Change (수평원관내 체적변화를 고려한 얼음의 용용시 전열특성에 관한 연구)

  • 조남철;김동춘;이채탈;임장순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1266-1274
    • /
    • 2001
  • Heat transfer phenomena during melting process of the phase change material (ice) was studied by numerical analysis and experiments. In a horizontal ice storage tube, the natural convection caused an increase in melting rate. However, the reduction of the heating surface area caused a decrease in melting rate. Therefore, during the melting process of ice in a horizontal cylinder, the reduction of the heating surface area should be considered. Under the same heating wall and initial water temperature condition, the melting rate became higher for $V_s/V_tot/=0.545 \;than \;that\; for\; V_s/V_tot$/=1.00 due to the difference in the reduction of heating surface area. A modified melting model considering the equivalent thermal conductivity of liquid phase and volume reduction was proposed. The results of the model were compared with the measured values and found to be in good agreement.

  • PDF

A Network Reduction using Weak Coupling Method (Weak Coupling Method를 이용한 계통 축약)

  • Lee, H.M.;Rho, K.M.;Kwon, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1067-1069
    • /
    • 1999
  • This paper presents a network reduction using weak coupling method. Weak coupling method of identifying coherent generator groups are proposed. The partitioning technique used in this paper is based on a property of sparse matrix factorization. When a matrix has been factorized, a system is divided into study area, boundary buses and external area. A reduction process for external system starts with the load bus elimination and coherent generator aggregation. An identification of coherent generator group, network partitioning and network reduction are presented.

  • PDF

Study on the Sweet Taste Perception, Perception of Sugar Reduction, and Utilization of Nutrition Labeling according to the Awareness of the Self-perceived Sugar Intake Reduction of University Students in Chungbuk Area (충북지역 대학생의 당류 저감 인식 여부에 따른 단맛 인지도, 당류 저감화 인식 및 영양표시 활용에 관한 연구)

  • Yeon, Jee-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.33 no.1
    • /
    • pp.18-25
    • /
    • 2018
  • This study examined the sweet taste perception, perception of sugar reduction, and utilization of nutrition labeling according to the awareness of the self-perceived sugar intake reduction of university students in Chungbuk Area. The subjects (n=419) were divided into two groups: Awareness of Sugar Intake Reduction (ASIR) group, male=110, female=109; Non Awareness of Sugar Intake Reduction (NASIR) group, male=115, female=85. The overweight/obesity was significantly higher in the ASIR group than in the NASIR group for both male and female students. The sweet taste perception was significantly lower in the ASIR group in male students than in the NASIR group. The purchase level of a product with reduced sugar instead of the original products was significantly higher in the ASIR group in male students than the NASIR group. Beverage purchases after identifying the sugar content were significantly higher in the ASIR group in male students than in the NASIR group. The necessity of nutrition labeling education was significantly higher in the ASIR group both male and female students. Based on these results, the correct perception of sugar reduction and continuous and practical nutrition education of sugar intake reduction need to maintain healthy dietary habits in university students.

Analysis of Reduction Strategies for Air Pollutants Discharged from Emission Sources and their Impact on the Seoul Metropolitan Area

  • Lee, Woo-Keun;SunWoo, Young
    • Asian Journal of Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.14-18
    • /
    • 2007
  • The Korean government enacted the "Special Law for Improving Air Quality of Metropolitan Area" in 2003. According to this plan, Korean government plan to lower the concentrations of $PM_{10}$ and $NO_x$ to $40{\mu}g/m^3$ and 22 ppb, respectively, by 2014. In this study, we analyze emission reduction strategies to lower their concentration. Emission reduction for the supply of mass energy and regenerative energy are compared with several scenarios. According to the results, 713 t/y of $NO_x$ and 165 t/y of $PM_{10}$ will be reduced by enhancing the number of households supplied by local heating and air conditioning. And also 5 t/y of $PM_{10}$ and 312 t/y of $NO_x$ will be reduced by replacing conventional energy with solar energy by 2014.

A Case Study on Development of Stormwater Retention and Infiltration Pond System (우수저류 및 침투연못 시스템개발 사례연구 - 우수 저류 및 침투 효과를 중심으로 -)

  • Lee, Jae Chul;Yoon, Yeo Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.4
    • /
    • pp.52-61
    • /
    • 2003
  • This study was carried out to analyze the effects of stormwater retention and infiltration pond on reduction of flood peak and volume in a experimentally developed ecological pond. The experimental site has 542$m^2$ watershed area, 1,310mm yearly-averaged rainfall. And the area of the retention pond is 60$m^2$, the maximum water depth is 0.5m, the maximum and average storage is 15$m^3$and 9.3$m^3$d. And the area of infiltration pond is 58$m^2$, and the water depth varies 0.2m~0.5m. The monitoring system consists of one rainfall gage, one Parshall flume and acoustic water level gage, two rectangular weirs and acoustic water level gage for discharge gaging, and one data recording unit. Data from ten storm events in total, three storm events in year 2000 and seven storm events in year 2001, were collected. From the data the evaporation rate was achieved with the water balance equation, and the result shows 5.0mm/day in average. The result from the analysis of the effects on reduction of flood peak and volume, is that 14% reduction of flood volume and 15% reduction of flood peak in retention pond and 49% reduction of flood volume in infiltration pond.