• Title/Summary/Keyword: reduced overflow

Search Result 39, Processing Time 0.029 seconds

A Study on the Application of an Environment Friendly Crossing Wood Drain for Easy Forest Road Management (산림관리도로의 생력화를 위한 친환경적 횡단목 배수로의 적용에 관한 연구)

  • Lee Sung-Gie;Lee Kab-Yeon;Kim Jong-Han;Kang Young-Je;Byun Kwang-Ok
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.521-524
    • /
    • 2005
  • We introduce a simplified crossing wood drain disperses rain water concentration and is used to protect the road surface from erosion due to flooding over the unpaved road. The efficiency of a simplified crossing wood drain was also investigated. A structure of simplified crossing wood drain can be produced within 10 minutes and installed within 18 minutes. The cost of the this product is 1/5 of that of the existing crossing drain product. The production and installation cost can be reduced according to dexterity. In the context of such applications, the degrees of damage for a rubber pad, which preventing the rain overflow, were varied according to their materials. A type of 8.2mm thick fabric rubber was the most suitable in this study.

Experimental Study on Pressures Changes on Infilling Soil and Geotextile Drain in Circular Acrylic Tube Structure (토사 주입과 배수 시 원형 아크릴 튜브 구조체의 압력 변화에 대한 실험적 연구)

  • Kim, Hyeong-Joo;Won, Myoung-Soo;Lee, Jang-Baek;Park, Tae-Woong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.3
    • /
    • pp.86-94
    • /
    • 2015
  • A series of injection and drainage test were conducted on an circular acrylic tube to investigate the pressure generated by the accumulated fill materials inside a circular acrylic tube structure. The acrylic tube was filled by means of gravity filling with a slurry material having an average water content of 700%. The water head during the filling process was 1.8m and the bottom pressure during initial filling was 20.18kPa. The recorded stress at the sides of the acrylic tube was 17.89kPa during the filling process and was reduced to 13.58kPa during the leaving process. Continuous drainage of the acrylic tube has greatly influenced the stresses around the tube structure. As the water is gradually allowed to overflow, the generated pressure at the topmost pressure sensor of the tube was reduced further to 2.17kPa. Eventually, the initially liquid state slurry material transforms into plastic state after water has dissipated and substantial soil particles are deposited in the acrylic tube. The final water content of the deposited silt inside the acrylic tube after the test was 42%. It was found that the state of stresses(geo-static earth pressures) in the acrylic tube was anisotropic rather than isotropic.

Separation Performance of a Low-pressure Hydrocyclone for Suspended Solids in a Recirculating Aquaculture System

  • Lee, Jin-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.2
    • /
    • pp.150-156
    • /
    • 2010
  • The separation performance of a low-pressure hydrocyclone (LPH) was evaluated for suspended-solids removal in a recirculating aquaculture system (RAS). The dimensions of the LPH were 335 mm cylinder diameter, 575 mm cylinder height, 60 mm overflow diameter, 50 mm underflow diameter, and $68^{\circ}$ cone angle. The inflow rate varied (400, 600, 800, and 1,000 mL $s^{-1}$) with 25%, 25%, 20%, and 10% of bypass ($R_f$), respectively. The maximum total separation efficiency (Et) and reduced separation efficiency (E't) for suspended solids from the effluent of the second settlement tank (before biofiltration) were 58.9% and 45.2%, respectively, at an inflow rate of 600 mL $s^{-1}$ and 25% of $R_f$. The maximum Et and E't for suspended solids from the water supply channel (after biofiltration) were 24.4% and 16%, respectively, at an inflow rate of 1,000 mL $s^{-1}$ and 10% of $R_f$. The maximum grade efficiency (Ei) was 51.6% for a 300 ${\mu}m$ particle size at an inflow rate of 600 mL $s^{-1}$ with 23% of $R_f$. The maximum reduced grade efficiency (E'i) was 37.6% for a 300 ${\mu}m$ particle size at an inflow rate of 1,000 mL $s^{-1}$ with 11% of $R_f$. The results indicate that the separation performance of the LPH for suspended solids removal was size selective and that maximum removal occurred at particle sizes ranging from 300 to 500 ${\mu}m$.

Analysis of Hydraulic Characteristics of Spillway using Hydraulic Model Experiments and Numerical Analysis (수리모형실험 및 수치해석을 통한 여수로 수리특성 분석)

  • Lee, Jong-Kyu;Lee, Jai-Hong;Kim, Joo-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1818-1822
    • /
    • 2008
  • Generally, not only in order to design three dimensional hydraulic structures such a spillway and to investigate the hydraulic phenomena concerning hydraulic facilities, but also to grasp shape and stability, we simulate actuality phenomenon through hydraulic model experiments. However, it requires too much times, expense and space to perform hydraulic model experiments, as well as it is very difficult to measure reduced scale of actual hydraulic structures. Besides, surface tension can exert fair effect in experiment result, and occasionally an experiment of various case is impossible actually. Therefore, there is necessity to draw proper early result through numerical analysis, and if decide the case of a hydraulic model experiment through the numerical analysis and compare the result, finally economical and reasonable design hydraulic structures are available. This study performs numerical analysis of overflow spillway and an experimental study of hydraulic model tests to design the optimal spillway and suggest a better design to improve hydraulic conditions. From the measurements, revised designs for an hydraulic structure are suggested and consequent improvement effects by the new design are also investigated.

  • PDF

A Performance Evaluation of the Highly Efficient Coagulation System for the Treatment of Overflows from Primary Clarifier in WWTP (강우시 하수처리장 일차침전지 월류수 처리를 위한 고효율응집시스템의 적용성 평가)

  • Gwon, Eun-Mi;Oh, Seok-Jin;Kim, Heung-Seup;Cho, Seung-Ju;Lee, Seung-Chl;Ha, Sung-Ryong;Lim, Chea-Hoan;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.391-398
    • /
    • 2011
  • This study is to develop highly efficient coagulation system(HECS) that runs treatment with a short retention time to cover the overflow in the rain, which coagulation, mixing and settling are contacted in a single reactor and to estimate the applicability. Setting up 100ton/day-size pilot scale plant, the results of continuous operation in case of runoff, maintaining 20 minute-retention time at optimum chemical injection condition(Alum 100mg/L, Polymer 1.0mg/L) shows the highest removal efficiency(Turbidity 93.1%, TCODcr 80.6%, BOD 81.8%, SS 92.5%, TN 72.3% and T-P 87.3%). It was estimated that the large amount of cost for separate sewage system and the size of area for system instruction can be reduced if the HECS is applied for CSOs treatment because the HECS is so compact and quickly. When we see the results, HECS from this study could be able to treat the pollutant quickly within a short retention time only with coagulant and polymer, which could show high applicability.

An Analysis of Potential Environmental Impact Reduction for Combined Sewer Overflow Project using a LCA Methodology (LCA 기법을 활용한 합류식 하수도 월류수 사업의 잠재적 환경영향 저감효과 분석)

  • Jo, Hyun-Jung;Song, Jang-Hwan;Hwang, Yong-Woo;Park, Ji-Hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.885-892
    • /
    • 2011
  • In this study, LCA(Life Cycle Assessment) on 'Saemangum CSO Project' was carried out to evaluate environmental impact which occurred during the construction and operation periods and the potential environmental impact reduction was analyzed by comparing production and reduction level of pollution loads. LCA was conducted out according to the procedure of ISO14040 which suggested Goal and Scope Definition, Life Cycle Inventory Analysis, Life Cycle Impact Assessment and Interpretation. In the Goal and Scope Definition, the functional unit was 1 m3 of CSO, the system boundary was construction and operation phases, and the operation period was 20 years. For the data collection and inventory analysis, input energies and materials from civil, architecture, mechanical and electric fields are collected from design sheet but the landscape architecture field is excepted. LCIA(Life Cycle Impact Assessment) was performed following the procedure of Eco-Labelling Type III under 6 categories which were resource depletion, eutrophication, global warming, ozone-layer destruction, and photochemical oxide formation. In the result of LCA, 83.4% of environmental impact occurred in the construction phase and 16.6% in the operation phase. Especially 78% of environmental impact occurred in civil works. The Global warming category showed the highest contribution level in the environmental impact categories. For the analysis on potential environmental impact reduction, the reduction and increased of environmental impact which occurred on construction and operation phases were compared. In the case of considering only the operation phase, the result of the comparison showed that 78% of environmental impact is reduced. On the other hand, when considering both the construction and operation phases, 50% of environmental impact is increase. Therefore, this study showed that eco-friendly material and construction method should be used for reduction of environmental impact during life cycle, and it is strongly necessary to develop technology and skills to reduce environmental impact such as renewable energies.

VLSI Design of EPR-4 Viterbi Decoder for Magnetic Disk Read Channel (자기 디스크 출력 채널용 EPR-4 비터비 디코더의 VLSI 설계)

  • ;Bang-Sup Song
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.7A
    • /
    • pp.1090-1098
    • /
    • 1999
  • In this paper ERP-4 viterbi decoder for magnetic disk read channel is designed. The viterbi decoder consists of ACS circuit, path memory circuit, minimum detection circuit, and output selection circuit. In the viterbi decoder the number of state is reduced from 8 to 6 using (1,7) RLL codes and modulo comparison based on 2's complement arithmetic is applied to handle overflow problem of ACS module. Also to determine the correct symbol values in nonconvergent condition of path memory, pipelined minimum detector which determines path with minimum state metric is used. The EPR-4 viterbi decoder is designed using 0.35${\mu}{\textrm}{m}$ CMOS technology and consists of about 15,300 transistors and has 250 Mbps data rates under 3.3 volts.

  • PDF

Digital Down Converter System improving the computational complexity (복잡도를 개선한 Digital Down Converter 시스템)

  • Moon, Ki-Tak;Hong, Moo-Hyun;Lee, Joung-Seok;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.11-17
    • /
    • 2010
  • Multi-standard, multi-band, multi-service system to ensure a flexible interface between the SDR (Software Defined Radio) technology for the implementation of the Stability and Low-Power, Low-Calcualrion DDC (Digital Down Conversion) technology is essential. DDC technology consists of a digital channel filter. This is a typical digital filter because of the limited fisheries are vulnerable to overflow and rounding errors are drawbacks. In this paper, we overcome this disadvantage, we propose the structure of the DDC. The way WDF (Wave Digital Filter) Structural rounding error due to the structural resistance to noise. Therefore, This is the useful structure when the filter coefficients's word length is short. In addition, since IIR filters based on FIR filters based on the amount of computation is reduced because fewer than filter's tap. The proposed structure is used in DDC that CIC (Cascaded Integrator Comb) filter, WDF, IFOP (Interpolated Fourth-Order Polynomials) were analyzed with respect to, the results were confirmed by computer simulation.

The Traffic Congestion Solution after a Large Scale Event - Based on the Case of ROK Joint Officer Commissioning Ceremony - (대규모 행사 이후 교통정체 해소방안 - 계룡대 장교 합동임관식 사례를 중심으로 -)

  • Jang, Sun-Ki;Park, Seung-Hwan;Jeong, Kyung-Won
    • Journal of the Korea Society for Simulation
    • /
    • v.26 no.3
    • /
    • pp.95-104
    • /
    • 2017
  • This study focuses on resolving traffic congestion caused by a large scale event based on the case of ROK Joint Officer Commissioning Ceremony, and it was conducted through literature review as well as Arena Simulation. The study purpose is to appropriately allocate and disperse the traffic by utilizing nearby parking lots of facilities. The annual event draws about 7,400 vehicles to a limited number of parking lots, and all vehicles leave the parking lots concurrently, causing a severe bottleneck near the exit and a few roads. In order to resolve the issue, the optimal number of cars in the event area was analyzed. After the analysis, the study found that the overflow of cars in the event area should be allocated to nearby parking lots of facilities with shuttle buses operating to transport the attendees. As the proposed result of the simulation, the traffic congestion time was reduced from 150 minutes to 64 minutes, a total reduction of 86 minutes.

Performance assessment of an urban stormwater infiltration trench considering facility maintenance (침투도랑 유지관리를 통한 도시 강우유출수 처리 성능 평가)

  • Reyes, N.J. D.G.;Geronimo, F.K.F.;Choi, H.S.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.424-431
    • /
    • 2018
  • Stormwater runoff containing considerable amounts of pollutants such as particulates, organics, nutrients, and heavy metals contaminate natural bodies of water. At present, best management practices (BMP) intended to reduce the volume and treat pollutants from stormwater runoff were devised to serve as cost-effective measures of stormwater management. However, improper design and lack of proper maintenance can lead to degradation of the facility, making it unable to perform its intended function. This study evaluated an infiltration trench (IT) that went through a series of maintenance operations. 41 monitored rainfall events from 2009 to 2016 were used to evaluate the pollutant removal capabilities of the IT. Assessment of the water quality and hydrological data revealed that the inflow volume was the most relative factor affecting the unit pollutant loads (UPL) entering the facility. Seasonal variations also affected the pollutant removal capabilities of the IT. During the summer season, the increased rainfall depths and runoff volumes diminished the pollutant removal efficiency (RE) of the facility due to increased volumes that washed off larger pollutant loads and caused the IT to overflow. Moreover, the system also exhibited reduced pollutant RE for the winter season due to frozen media layers and chemical-related mechanisms impacted by the low winter temperature. Maintenance operations also posed considerable effects of the performance of the IT. During the first two years of operation, the IT exhibited a decrease in pollutant RE due to aging and lack of proper maintenance. However, some events also showed reduced pollutant RE succeeding the maintenance as a result of disturbed sediments that were not removed from the geotextile. Ultimately, the presented effects of maintenance operations in relation to the pollutant RE of the system may lead to the optimization of maintenance schedules and procedures for BMP of same structure.