• Title/Summary/Keyword: recovery pattern

Search Result 366, Processing Time 0.026 seconds

Research of Synchronization Schemes for Uplink Cable Modem System (상향 링크 케이블 모뎀 시스템을 위한 동기 방법)

  • Kim, Young-Je;Oh, Wang-Rok;Kim, Whan-Woo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.2
    • /
    • pp.6-12
    • /
    • 2008
  • In uplink cable modem link operated in time-division multiple access mode, it is crucial to employ a suitable preamble pattern enabling frame detection, coarse timing/carrier recovery. Preamble pattern based on the constant envelope zero autocorrelation sequence is proposed for the uplink cable modem compliant to the data over cable service interface specification. Frame detection, coarse/fine timing and carrier recovery algorithms suitable for the proposed preamble pattern are also proposed. We check up the performances using numerical results.

Stress and Coping on Home Treatment in Mothers of Children with Delayed Development (발달장애아동의 가정치료에 대한 어머니의 스트레스와 대처 특성에 관한 연구)

  • Park, Sang-Hee;Hwang, Byong-Yong;Yoon, Bum-Chul
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.727-734
    • /
    • 2001
  • The purpose of this study was to obtain the information of the home treatment state for children with delayed development and to identify stress and coping pattern in mothers of the children. Data were collected from 211 mothers of delayed developmental children(DDC) by means of structured questionnaires. The results of this study were that in the home treatment mothers had technical insufficiencies to treat their children. so they had a difficulties in treating their children at home. But the home treatment were effective and mothers were assisted by their family and others in their treatment. The mothers had stress by anxiety of prognosis. hurts, responsibility, technical insufficiencies and negligent in housework. And acquisition of home treatment technique, the existence of assistant, and emotion in treatment also influenced on stress in the mother. The coping pattern in the stress were regular medical examination. communication with medical team and other mothers with DDC, faith of recovery and treatment. confidence in home treatment, family coorperation. and leisure time without concern for treatment. The younger mother received the more help from other mothers with DDC. And the mothers with severe, complex DDC had the more help from faith of recovery. Regular medical examination and faith of recovery were helpful coping pattern in mothers who had no treatment skill. Confidence in family coorperation and leisure time without concern for treatment were particularly helpful in mothers whose treatment duration is longer, and home treatment was not effective.

  • PDF

Comparision of Heat Exchanging Performance Depending on Different Arrangement of Heat Exchanging Pipe (II) (열회수장치의 열교환 파이프배치형식별 열교환 성능 비교(II))

  • Suh, Won-Myung;Kang, Jong-Guk;Yoon, Yong-Cheol;Kim, Jung-Sub
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.281-285
    • /
    • 2001
  • This study was carried out to improve the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. Three different units were prepared for the comparison of heat recovery performance; AB-type(control unit) is exactly the same with the typical one fabricated for previous study of analyzing heat recovery performance in greenhouse heating system, other two types(C-type and D-type) modified from the control unit are different in the aspects of airflow direction(U-turn airflow) and pipe arrangement. The results are summarized as follows; 1. In the case of Type-AB, when considering the initial cost and current electricity fee required for system operation, it is expected that one or two years at most would be enough to return the whole cost invested. 2. Type-C and Type-D, basically different with Type-AB in the aspect of airflow pattern, are not sensitive to the change of blower capacity with higher than $25\;m^{3}/min$. Therefore, heat recovery performance was not improved so significantly with the increment of blower capacity. This is assumed to be that air flow resistance in high air capacity reduces the heat exchange rate as well. Never the less, compared with control unit, resultant heat recovery rate in Type-C and Type-D were improved by about 5% and 13%, respectively. 3. Desirable blower capacity for these heat recovery units experimented are expected to be about $25\;m^{3}/min$, and at the proper blower capacity, U-turn airflow units showed better heat recovery performance than control unit. But, without regard to the type of heat recovery unit, it is recommended that comprehensive consideration of system's physical factors such as pipe arrangement density, unit pipe length and pipe thickness, etc., are required for the optimization of heat recovery system in the aspects of not only energy conservation but economic system design.

  • PDF

Factors Influencing Visual Field Recovery after Transsphenoidal Resection of a Pituitary Adenoma

  • Lee, Dong Kyu;Sung, Mi Sun;Park, Sang Woo
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.488-496
    • /
    • 2018
  • Purpose: This study aimed to analyze the factors influencing visual field recovery after transsphenoidal approach-tumor resection (TSA-TR) in pituitary adenoma patients with visual field defects (VFDs). Methods: We retrospectively evaluated 102 eyes of 102 patients with VFDs induced by pituitary adenomas who underwent TSA-TR between January 2010 and December 2015. All patients had been observed for more than one year. The severity of the VFD in each patient was evaluated using the mean deviation (MD) and pattern standard deviation in the most-affected eye. Clinical and demographic data such as preoperative visual acuity and visual field, age, sex, tumor volume, neurological symptoms at diagnosis, duration of symptoms, patterns of the preoperative VFD, and preoperative central VFD were investigated and analyzed for association with recovery of the visual field. Results: Recovery from VFDs occurred in 71 (69.6%) eyes after a mean period of $18.36{\pm}5.21$ months. The recovery group was younger (p = 0.003), had higher preoperative MD values (p = 0.016), and had better preoperative visual acuity (p = 0.03), compared with the non-recovery group. Preoperative central VFD (p = 0.006) and preoperative bilateral VFD (p = 0.016) were significantly less frequent in the recovery group. Multivariate logistic regression revealed that age at diagnosis (odds ratio [OR], 0.962; p = 0.022), preoperative MD (OR, 1.069; p = 0.046), preoperative central VFD (OR, 0.212; p = 0.039), and preoperative bilateral VFD (OR, 0.212; p = 0.035) were associated with visual field recovery after TSA-TR. Conclusions: Younger age, higher preoperative MD, and the preoperative abscence of central VFD or bilateral VFD were favorable factors influencing visual field recovery after TSA-TR in patients with pituitary adenomas. An understanding of the associated clinical factors may help predict visual outcomes after TSA-TR in pituitary adenoma patients with VFDs.

Effects of Salinity on Chlorophyll Fluorescence from Porphyra Thalli and Comparison of Species with Different Intertidal Distribution

  • Hong Dang Diem;Kim Tae Hoon;Hwang Mi Sook;Chung Ik Kyo;Lee Choon-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • v.1 no.1
    • /
    • pp.122-128
    • /
    • 1998
  • Characteristic changes in chlorophyll fluorescence from thalli of red alga, Porphyra, under high salt stress and during subsequent recovery were investigated, and the differences in the sensitivity to the stress among four species of Porphyra with different intertidal distributions were compared. By the treatment of NaCl with $9\%$ or higher concentrations, photochemical efficiency (Fv/Fm) decreased in a biphasic pattern: a rapid decrease was observed within 1­3 h and followed by a slow decline. The decrease of Fv/Fm was mainly due to the increase of Fo without significant increases of Fm. When the thalli treated with $15\%$ NaCl for 6 h were returned to natural sea water for recovery, the increase of Fv/Fm also showed a biphasic pattern: a rapid increase of Fv/Fm was observed within 2 h and followed by a slow increase. Differences in the sensitivity to salt stress among the four species could be found during recovery after the treatment of severe salt stress. After the treatment of $20\%$ NaCl for 6 h, Fv/Fm decreased below 0.3 in all of the four Porphyra species, and the species living in upper parts of the intertidal zone (P. suborbiculata and P. pseudolinearis) could recover better compared with the species in lower parts of the intertidal zone (P. seriata and P. yezoensis), during recovery for 24 h. The species collected from the coast of the South Sea seemed to be more tolerant than those in the East Sea.

  • PDF

A Comparative Study on Factor Recovery of Principal Component Analysis and Common Factor Analysis (주성분분석과 공통요인분석에 대한 비교연구: 요인구조 복원 관점에서)

  • Jung, Sunho;Seo, Sangyun
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.6
    • /
    • pp.933-942
    • /
    • 2013
  • Common factor analysis and principal component analysis represent two technically distinctive approaches to exploratory factor analysis. Much of the psychometric literature recommends the use of common factor analysis instead of principal component analysis. Nonetheless, factor analysts use principal component analysis more frequently because they believe that principal component analysis could yield (relatively) less accurate estimates of factor loadings compared to common factor analysis but most often produce similar pattern of factor loadings, leading to essentially the same factor interpretations. A simulation study is conducted to evaluate the relative performance of these two approaches in terms of factor pattern recovery under different experimental conditions of sample size, overdetermination, and communality.The results show that principal component analysis performs better in factor recovery with small sample sizes (below 200). It was further shown that this tendency is more prominent when there are a small number of variables per factor. The present results are of practical use for factor analysts in the field of marketing and the social sciences.

Molecular Dynamics Study on the Effect of Process Parameters on Nanoimprint Lithography Process (공정인자들이 나노임프린트 리소그래피 공정에 미치는 영향에 대한 분자동역학 연구)

  • Kang, Ji-Hoon;Kim, Kwang-Seop;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.243-251
    • /
    • 2006
  • Molecular dynamics simulations of nanoimprint lithography NIL) are performed in order to investigate effects of process parameters, such as stamp shape, imprinting temperature and adhesive energy, on nanoimprint lithography process and pattern transfer. The simulation model consists of an amorphous $SiO_{2}$ stamp with line pattern, an amorphous poly-(methylmethacrylate) (PMMA) film and an Si substrate under periodic boundary condition in horizontal direction to represent a real NIL process imprinting long line patterns. The pattern transfer behavior and its related phenomena are investigated by analyzing polymer deformation characteristics, stress distribution and imprinting force. In addition, their dependency on the process parameters are also discussed by varying stamp pattern shapes, adhesive energy between stamp and polymer film, and imprinting temperature. Simulation results indicate that triangular pattern has advantages of low imprinting force, small elastic recovery after separation, and low pattern failure. Adhesive energy between surface is found to be critical to successful pattern transfer without pattern failure. Finally, high imprinting temperature above glass transition temperature reduces the imprinting force.

Correlation Study between the Changes of the Fire- and Heat- Related Symptoms and Motor Function Recovery in Acute Cerebral Infarction Patients (급성기 뇌경색 환자의 화열증상 변화와 기능회복도간의 상관관계에 대한 연구)

  • Hyun, Sang-Ho;Min, Kyung-Dong;Yei, Young-Chul;Kang, Ah-Reum;Lee, Eun-Chan;Moon, Sang-Kwan;Cho, Ki-Ho;Jung, Woo-Sang;Park, Sung-Wook;Ko, Chang-Nam
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.4
    • /
    • pp.428-437
    • /
    • 2013
  • Objectives : The aim of this study was to examine if there is a significant correlation between the changes of Fire- and Heat- related symptoms and motor function recovery in acute cerebral infarction patients. Methods : We studied inpatients within a month after the onset of cerebral infarction who were admitted at Kyunghee University Medical Center from May 2011 to January 2013. We executed correlation analysis between Fire-heat pattern score and motricity index score at visit 1 and visit 2, and checked if there was a significant correlation between the changes of Fire-heat pattern score and changes of motricity index score. Also, we compared the changes of both scores in patients taking Fire-heat and non Fire-heat pattern prescriptions. Results : There was a significant correlation between the Fire-heat pattern score and Motricity index score at visit 1 and visit 2, and changes of Fire-heat pattern score showed significant correlation with changes of motricity index score. Patients taking Fire-heat pattern prescriptions showed significant change in Fire-heat pattern score after herb-medication treatment while patients taking non-Fire-heat prescriptions showed insignificant change in Fire-heat pattern score. Conclusions : This study provides evidence that taking a Fire-heat pattern prescription could be considered as a first line herb-medication treatment in acute cerebral infarction patients.

All optical clock recovery from 10 Gb/s RZ signal using an actively mode-locked figure eight laser incorporating a SLALOM (반도체 광증폭기 루프 거울을 포함한 8자형 레이저를 이용한 10Gb/s RZ 신호의 전광 클럭 추출)

  • 정희상;주무정;김광준;이종현
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.6
    • /
    • pp.400-404
    • /
    • 2000
  • All-optical clock recovery from a 10 Gb/s RZ signal has been demonstrated using an actively mode-locked figure-eight laser incorporating a semiconductor optical amplifier in the loop-mirror scheme. Optical pulses with 10 ps pulse width were modulated by a LiNb03 external modulator at $2^{23}-1$ PRES and injected into the clock recovery circuit to extract optical pulses with 12 ps width. Regeneration of the original bit pattern has been accomplished by modulating the recovered clock with the same modulator, and no power penalty was observed at $10^{11}$..

  • PDF