• 제목/요약/키워드: recording period

검색결과 244건 처리시간 0.027초

전라남도 연안에 서식하는 주꾸미(Amphioctopus fangsiao)의 산란시기와 유어낚시 어획실태 (Spawning Period and Estimated Recreational Catch of Amphioctopus fangsiao in the Coastal Waters of Jeollanam-do, Korea)

  • 문성용;김희용;이미희;정경미;김맹진
    • 한국수산과학회지
    • /
    • 제55권1호
    • /
    • pp.61-66
    • /
    • 2022
  • Amphioctopus fangsiao is a crucial fishery stock located off Korea's western and southern coasts. In this study, we present data on the spawning period and estimated recreational catch of A. fangsiao in the coastal waters of Jeollanam-do, South Korea. The overall sex ratio was estimated to be 1:1.13 (female: male); in females and males, the gonadosomatic index ranged from 1.22 to 12.14 and 0.17 to 3.44, respectively. The breeding season lasted from December to May, with spawning peaks observed between March and May. Furthermore, the estimated total annual recreational catch of A. fangsiao was 185,085 kg, with November recording the highest recreational catch. A. fangsiao catch per unit effort (CPUE) ranged from 3 to 302.4 kg per vessel d-1. Therefore, these findings underscore the need for additional monitoring, as any further assessment of A. fangsiao stock necessitates an understanding of recreational catch assessment and fishing efforts in Jeollanam- do's coastal waters.

종합병원 간호사의 혈압측정의 정확성 평가 (Evaluating the Accuracy of Blood Pressure Measurement in General Hospital Nurses)

  • 김종숙;김상순
    • 기본간호학회지
    • /
    • 제7권1호
    • /
    • pp.7-15
    • /
    • 2000
  • 임상 간호사의 혈압측정의 정확도를 평가하고 이에 관련된 요인을 조사하기 위하여 1998년 12월 20일부터 12월 29일까지 포항시와 경주시의 4개 종합병원 간호사 276명을 대상으로 혈압측정 실태를 조사하였다. 연구자는 20개 항목의 혈압측정 지침서를 이용하여 간호사들이 가상환자를 대상으로 실제 혈압측정 하는 과정을 직접 관찰하고 정확도를 평가하였다. 혈압측정 실천정도의 준비단계에서는 6개 항목 중 '혈압측정 중에는 말을 하지 않도록 요구한다' 27.1%로 가장 낮았고 나머지 항목들의 실천률은 모두 80% 이상이었다. 측정단계에서는 10개 항목 중 '요골(또는 팔)동맥이 촉지 되지 않는 지점에서 30mmHg까지 높인다' 0%, '30-60초 정도 기다린다' 0%, '압박대의 공기 압력을 빠른 속도로 제거한다' 0.3%', '혈압계의 압력을 상완동맥이 없어지는 지점에서 약 30mmHg 정도 더 높인다' 0.7%, '혈압계상의 혈압치를 2mmHg 단위로 읽는다' 10.8%g로 아주 낮았고 나머지 5개 항목들의 실천률은 70% 이상이었다. 측정결과 기록단계에서는 4개 항목 중 '압박대의 크기를 기록한다' 0.3%, '환자의 자세(앉은 자세, 누운 자세, 선 자세)를 기록한다'는 10.8%에 불과했고 '혈압측정에 사용한 팔(오른팔, 왼팔, 양팔)과 다리를 기록한다'는 53.6%로 낮았으며 '수축기와 이완기 혈압을 기록한다'는 100%이었다. 혈압측정 실천정도와 유의한 관련성이 있는 변수들은 연령, 경력, 직위 그리고 병원근무 중 혈압 측정방법에 대한 보수교육 경험 유무 등 4개였다(p<0.01). 다중 회귀분석에서는 혈압측정 실천과 유의하게 관련된 변수는 간호사의 직위와 혈압측정에 대한 보수교육 경험 유무였다(p<0.01). 이상의 결과를 볼 때 종합병원 임상간호사의 혈압측정의 정확도는 상당히 낮았다. 따라서 이에 대한 보수교육을 시급히 실시해야 할 것으로 생각한다.

  • PDF

악교정 환자의 악교정 수술전후 발음양상에 대한 비교연구 (The Comparative Study of Effect on Speech before and after Orthognathic Surgery of Patients)

  • 권경환;김수남;이동근;조용민;이숙향
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제22권2호
    • /
    • pp.191-205
    • /
    • 2000
  • The purpose of this study was undertaken to determine the effects of orthognathic surgery on speech. The hyposis stated herein is that functional behaviors of the dentofacial complex, such as speech production, may be adversely affected by deviations of a structural nature(especially, Class III malocclusion). Twenty adults with Class III malocclusion(13 female and 7 male) were studied preoperative, immediate postoperative and either 6 or 12 months postoperative lateral cephalograms. They had mandibular prognathism and had undergone mandible setback operation. The position of tongue, soft palate(Uvula), hyoid bone, respiratory track width, and pharyngeal depth were assessed on lateral cephalograms with 23 cephalometric variables, ANOVA, Paired t-tests and Pearson's product-moment correlation coefficient tests were used to evalute the operative changes in all cephalometric parameters. A experienced speech and language pathologists performed narrow phonetic transcriptions of tape-recorded words and sentences produced by each of the ninth patients and the recording tapes were analyzed by phonetic computer program(Computerized Speech Lab(CSL) Model 4300BI(U.S.A.)) These judges also recorded their ratings of each patient's overall consonants, hypernasality, hyponasality, and articulation proficiency. The results obtained are as follows; 1. There were significant changes in distance of posterior pharyngeal wall to tongue (TI-TW2, TS-TW3) after the surgery at 6 months postoperatively(each p<0.01 p<0.05). 2. The posterior tongue point(TI, TS, PPT) moved posteriorly after surgery and remained to its changed position at 6 months postoperatively(p<0.05). The displacement of tongue was correlated with the movement of mandibular setback amount(p<0.05). The hyoid bone moved posteriorly superiorly after immediate postoperative period. There was significant changes in hyoid bone movement after immediated postoperative period(p<0.05), but returned to its original position during the follow-up period(p>0.05) 3. The soft palate was displaced posteriorly superiorly after immediated operative period and remained to its changed position at 6 months postoperatively(p<0.05). ANS-PNS-SPT angle increasing, PPU-PPPo distance narrowing was showed after surgery, and remained its appearance 6 months postoperatively(p<0.05). 4. There were significant changes in formant value and squre diagram of vowel sound after the orthognathic surgery and the follow-up period. There were significant changes in /ㅅ/sound and posterior tongue sound. 5. The posterior movement of tongue and the posteriosuperior movement of soft palate was correlated with mandibular setback amount after orthognathic surgery. On the vowel squre diagram, the author found that the place of articulation after operation moved downward, backward, upward. 6. In assessing speech abnormalities, dental occlusion should be considered as a contributing factor. The vast majority of subjects with preoperative misarticulations eliminated or reduced their errors following orthognathic surgery. There was significant difference in speech impovement between pre- and postoperation.

  • PDF

The Mineralogy and Geochemistry of the Uppermost Sediments of the Lake Hovsgol, North Mongolia : It's Implication to the Paleoenvironmental Changes

  • Tumurhuu, D.;Narantsetseg, Ts.;Ouynchimeg, Ts.
    • 한국제4기학회지
    • /
    • 제18권2호통권23호
    • /
    • pp.3-3
    • /
    • 2004
  • One short core with length of 146cm(HB-107, at coordinates of $N51^{\circ}$11'37.5";$E100^{\circ}$24'45.6", from 229m water depth was subject of the present study. The sub-samples of the core were analyzed for the water contents (WC%), biogenic silica, identification of the main phases, grain size distribution, geochemistry and some physical properties of sediment(Wet density and Magnetic susceptibility) with aims of recording palaeo-environmental changes in Northem Mongolia. The evaluation of the geochemical and mineralogical proxies on palaeo-climated and palaeo-environmental changes are based on comparison to the behvior of biogenic silica through core, as later one had been showed itself, as good indicator of the climate and environmental fluctuation. Age model of the investigating core based on previously C 14 dated core HB105 taken from the central part of the Hobsgol Lake and the result had been published elsewhere. The core consists of two litological varieties : upper diatomaceous silt, lower clay. According to the age model the upper diatomaceous silt formed during the Holocene, lower caly-during the late Pleistocene glacial period. The geochemistry and phase identification analysis on the core samples are resulted in determining main minerals that form the bottom sediments and their geochemistry. The main include quartz, felspar, muscovite, clinochlore, amphibole and carbonate phase(dolomite and calcite). Through the core not only occur the relative quantitative changes of the main phases, but also happen that the carbonate phase completely disappear in diatomaceous silt. This is believed to be related to the lake water salinity changes, which occurred during the trassition period from Pleistocene glacial-to the Holocene interglacial. These abrupt changes of the mineralogy have been clearly traced in geochemistry of sediments, specially in calcium concentration, which is high in lower clay and low in upper diatomaceous silt. That means, geochemistry and mineralogy of the bottom sediments can be used as proxy data on palaeo-climate and palaeo-environmental changes.

  • PDF

외부의료영상의 PACS 등록 시 OCS상 FTP Module의 유용성 (Usefulness of FTP Module on OCS for PACS Registration of External Medical Images)

  • 정명진;동경래;지연상;최정길;전재두
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.35-41
    • /
    • 2009
  • This study was conducted to improve performance flow of PACS registration and output of external medical images by developing or adding File Transfer Protocol(FTP) Module on Order Communication System(OCS) and to upgrade efficiency of performance. The numbers of requests for examination of external medical images from January 2004 to December 2007 were investigated and the numbers of cases of examinations and losses were done respectively from January to June, 2007 as a period before the improvement and from July to December, 2007 as a period after it. Satisfaction of persons inputting external medical images of CD was asked directly before and after the improvement. When the numbers of requests for examination of external medical images from 2004 to 2007 2004 were investigated, they were 12,783, 16,774, 21,613 and 27,487 cases in 2004, 2005, 2005 and 2007 respectively. For the numbers of the requests from January to December, 2007 it was the lowest in February by recording 1846 and it was 2800 in October. While the number of loss of external medical images was averagely 3.6 before using FTP Module on OCS, it reduced to 0 and satisfaction increased to 98% after it. By utilizing FTP Module on OSC for PACS registration of external medical images, the images were delivered simultaneously with occurrence of order, PACS registration of many patients was conducted together and CDs were returned to patients immediately after sending images from outpatient clinics or wards to remove possibility of losing them. In addition, because the module was established on OCS and data were sent associated with order, problems related with order were decreased. By eliminating movement distance it was turned out to be very effective in terms of time and space.

  • PDF

시선추적 실험에 따른 가로공간요소의 관심영역 분석 (An Analysis of AOI(Area of Interest) based on the Eye-Tracking Experiment according to Streetscape Elements)

  • 김주연;박준수
    • 한국실내디자인학회논문집
    • /
    • 제26권5호
    • /
    • pp.65-74
    • /
    • 2017
  • The purpose of this research is to analyze characteristics of street elements when pedestrians have a view in the street. The research was utilized eye-tracking experiment and two times survey before and after experiment. The experiment is composed as follows. The data collection was conducted two days period from March 30 to 31, 2017. There were 43 participants who were all male and undergraduate students. In the data recording, the stimulus image was presented 65 seconds on a 23-inch monitor. Prior to analyzing data, the images were represented into five elements of AOI(area of interest). The fixation rate was divided by a period such as 'fixation time' and 'fixation count' parameters. The results were additionally obtained by linking analysis with the area ratio of AOI, time series analysis, and questionnaire. First of all, both building signs and advertisement standing boards draws attentions in participants. From a comparison between fixation rate and survey, the data have negative perspective view. Second, the advertisement standing boards are more eye-catching than other elements regardless of AOI size. It shows the priority of elements what should be developed in the environment. Third, the pavement is rarely seen in the fixation rate. Fourth, the trees are not a long frequency but viewed as a positive element. People want to keep the natural site in the street. In summative research, this method of extracting eye movement data would be provided a foundation data for developing streetscape plan based on scientific factors.

Crosserase와 crosstalk이 DVD 재생 신호에 미치는 영향 (Crosserase and Crosstalk Effects on Readout Signal of Digital Versatile Disks)

  • 박연수;김지원;조순철
    • 전자공학회논문지CI
    • /
    • 제38권4호
    • /
    • pp.33-38
    • /
    • 2001
  • 고밀도 기록매체인 DVD RAM 시스템에서 단면 기록밀도 4.7 GB, 15 GB 매체 개발 실현에 가장 큰 걸림돌로 작용하고 있는 crosserase 및 crosstalk 현상이 재생 신호에 미치는 영향을 분석하기 위해 4.7 GB 및 15 GB 규격으로 재생 신호를 시뮬레이션 하였다. 디스크에 조사된 빔의 강도는 Gaussian으로 근사화하고 기록된 마크는 타원형 마크로 가정하였으며, 재생신호는 Gaussian 빔 패턴과 마크 패턴의 이중 적분으로 계산되었다. Crosserase 정도를 변하여 얻어진 재생 신호로부터 주파수 분석을 통하여 3T-11T 마크의 carrier level의 크기를 구하여 비교하였다. 1,000개의 3T-11T 랜덤 마크로 부터 crosserase 및 crosstalk 에 의한 지터를 계산하여 비교한 결과, crosserase에 의한 지터가 crosstalk에 의한 지터 보다 상대적으로 작음을 확인할 수 있었다.

  • PDF

트레드밀 운동 동안 인솔의 종류가 피로도에 미치는 영향 (Effect of the Fatigue to Insole Types During Treadmill Exercise)

  • 고은혜;최흥식;김택훈;노정석;이강성
    • 한국전문물리치료학회지
    • /
    • 제11권2호
    • /
    • pp.17-25
    • /
    • 2004
  • The purpose of this study was to assess the effect of applied insole types to lower extremities muscle fatigue during treadmill exercise. The control group and each different insole type group consisted of ten healthy male subjects. In the control group and each different insole type (soft type; 10 shore, semi-rigid type; 33 shore, rigid type; 50 shore) treadmill exercise was performed in twenty-five minutes. The electromyography (EMG) signals of four muscle (tibialis anterior, gastrocnemius medialis, rectus femoris, biceps femoris) were recording at sampling rate of 1024 Hz during treadmill exercise. The localized muscle fatigue (LMF) can be investigated using power spectral analysis. When did data analysis that excepted initial five minutes. The raw EMG signals was processed using the fast Fourier Transformation (FFT) and the median power frequency value was determined in initial ten second period and in last ten second period. Fatigue index was calculated and collected data were statistically analyzed by SPSS version 10.0 two-way using analysis of variance (ANOVA) with repeated measures ($4{\times}4$) was used to determine the main effect and interaction. Post hoc was performed with least significant difference. A level of significance was .05. Muscles fatigue index were significantly decreased in insole types (p<.05) and not significantly different in muscle (p>.05). Post hoc analysis shows that fatigue index in soft insole type, semi-rigid insole type and rigid insole type were lower than that control group (p=.028, p=.146, p=.095). There were no interaction between insole type and muscles (p>.05). The finding of this study can be used as a fundamental data when insole is applied and insole can be used to decreased of a fatigue during the dynamic exercise.

  • PDF

토끼 심장세포의 전기적 활동에 대한 갑상선 호르몬의 효과 (Effects of Thyroid Hormone in vitro on the Electrical Activity of the Rabbit Heart Cell)

  • 홍성근;윤효인
    • 대한수의학회지
    • /
    • 제27권1호
    • /
    • pp.27-34
    • /
    • 1987
  • To verify the direct effects of the thyroid hormone ($T_3$) on the rabbit heart, $T_3$-Tyrode solution in vitro was perfused on the normal atrial muscles and enzymatically isolated ventricular myocytes of the rabbit. All the experimental procedures were conducted at $35^{\circ}C$ and the same procedures were repeated after Ca. 120 minutes from the beginning of $T_3$-Tyrode perfusion. Compared to the state between the normal Tyrode solution and $T_3$-Tyrode solution, results were observed on the same cells by electrophysiological methods (conventional intracellular recording and whole cell patch clamping) as soon as possible. The results obtained were as follows : 1. Action potential duration (APD) on the left atrial muscle was reduced under the perfusion of $T_3$-Tyrode. 2. Absolute refractory Period was shortened by $T_3$-Tryrode perfusion. (117 msec./114 msec., 90 msec./78 msec.) 3. Maximal Ca currents ($i_{Ca}$) were decreased in single: ventricular myocytes under the $T_3$-Tyrode (2.98 nA) than under the normal Tyrode (6.65 nA) 4. On I-V relation, reversal potential was shifted to lower membrane potential and membrane potential showing maximal $i_{Ca}$was lowered from +10mV to -20mV by $T_3$ effect. 5. Above results were likely to explain that tachycardia in the hyperthyroid state was caused in part by the reduced repolarization phase and the reduced refractory period due to the decrease of the Ca current.

  • PDF

Sprague-Dawley 랫드를 이용한 미선나무주정추출물의 2주 반복 경구투여 독성평가 (Toxicity Assessment of Abeliophyllum distichum Nakai Ethanol Extract Orally Administered to Sprague-Dawley Rats for Two Consecutive Weeks)

  • 권순복
    • 한국식생활문화학회지
    • /
    • 제34권6호
    • /
    • pp.801-809
    • /
    • 2019
  • Abeliophyllum distichum Nakai is a deciduous shrub of a flowering plant in Oleaceae. It is an important plant resource and consists of only one species in the entire world. A. distichum Nakai is well known an edible, medicinal herb in its habitat districts, but the toxicological evaluation for the safe use of its extract is still insufficient. The study characterized the toxicity of an Abeliophyllum distichum Nakai ethanol extract in Sprague-Dawley (SD) rats and determined the safe dosage levels in a 13 weeks toxicity study. Abeliophyllum distichum Nakai ethanol extract was orally administered once daily for 2 weeks at 0, 500, 1,000 and 2,000 mg/kg/day to male and female SD rats. while recording the clinical signs of toxicity, body weight, food intake/consumption, eye test and urine analysis. Only the total protein frequency in the urine of male SD rats (p<0.05), the right ovary of the 500 mg/kg group (p<0.01) and the right adrenal gland of the 1,000 mg/kg group (p<0.05) in the female rats showed statistically significant changes. But no toxic effects were noted from repeated-dose administration of the Abeliophyllum distichum Nakai ethanol extract in the SD rats during the observation period. The post-mortem examinations showed no test substance-mediated changes. The hematological analysis and clinical blood chemistry data demonstrated no toxic effects from repeated-dose administration of Abeliophyllum distichum Nakai ethanol extract in the SD rats during the observation period. Based on these results, this data suggests that a dose of 1,000 mg/kg/day is a highest treatment to administer when conducting a further 13 weeks toxicity study.