• Title/Summary/Keyword: reconstructive elevator

Search Result 17, Processing Time 0.026 seconds

Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking

  • Kim, Jun Sik;Park, Young Ji;Lee, Yoon Jung;Kim, Nam Gyun;Lee, Kyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.4
    • /
    • pp.198-201
    • /
    • 2016
  • Background: Zygomatic arch is a bony arch constituting the lateral midface, which consists of 25% of all midface fractures. There are a number of ways to evaluate the extent of zygomatic arch fracture. Some authors have reported successful treatment outcomes using ultrasound (U/S). To add to the previous methods, we have considered ways to accurately display the location of the fracture line while using U/S with 23 gauge needle marking. We introduce our method, which provided satisfactory results for reduction using a portable U/S, and it can evaluate the fracture line simultaneously when reduction of an isolated zygomatic arch fracture is necessary, and needle marking, which can easily point out the fracture line on U/S. Methods: We studied 21 patients with an isolated zygomatic arch fracture who underwent closed reduction using U/S and needle marking between 2013 and 2015. Results: We achieved satisfactory results in all our cases with respect to reduction by using the Dingman elevator after performing a temporal approach incision, while confirming relative positioning between needle marking and zygomatic fracture at the same time, after insertion of a 23 gauge needle in the skin above the zygomatic arch fracture line parallel to it. Conclusion: We treated 21 patients with an isolated zygomatic arch fracture using U/S and the needle marking method, which provided satisfactory results because the extent of reduction of the fracture could be evaluated in real-time during the operation and exposure to radiation was reduced.

Open reduction of zygoma fractures with the extended transconjunctival approach and T-bar screw reduction

  • Song, Seung Han;Kwon, Hyeokjae;Oh, Sang-Ha;Kim, Sun-Je;Park, Jaebeom;Kim, Su Il
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.325-332
    • /
    • 2018
  • Background Zygomaticomaxillary complex (ZMC) fractures mostly occur in the form of tripod fractures. The surgical field is accessed using a combination of three classic approaches. However, the subciliary incision may have unfavorable aesthetic results. Herein, the authors report the advantages of the extended transconjunctival approach (ETA) combined with T-bar screw reduction in minimizing scarring and complications for the treatment of ZMC fractures. Methods A total of 26 patients underwent ZMC reduction through the ETA and intraoral approach. A skin incision measuring roughly 5 to 8 mm in length was placed following the lateral canthal skin crease. After releasing the inferior crus of the lateral canthal tendon for canthotomy, the medial periosteum of the lateral orbital rim was preserved for canthal reattachment. A limited subperiosteal dissection and partial relaxing incision of the orbicularis oculi were performed to expose the fracture line of the inferior orbital rim and zygomaticofrontal suture. Reduction was performed using a T-bar screw through the transconjunctival incision and an elevator through the intraoral incision. Results The aesthetic and functional results were excellent. Successful reduction was achieved and the skin incision was less than 8 mm in 20 cases (76.9%). Only six patients had an additional skin incision (less than 5 mm) to achieve reduction. No cases of ectropion, entropion, or excessive scarring were noted. Conclusions The ETA using a T-bar screw is a useful method for maximizing aesthetic results in ZMC fractures, with the advantages of minimal scarring, faster recovery, and maintenance of pretarsal fullness.

A CASE REPORT: THE SURGICAL REMOVAL OF THE DISPLACED MAXILLARY THIRD MOLAR INTO THE PTERYGOPALTINE FOSSA BY THE MIDPALTAL AND TRANSPHARYNGEAL APPROACH (Pterygopaltine fossa로 전위된 상악 매복지치 발치 치험례)

  • Jang, Hyun-Suk;Jang, Myung-Jin;Kim, Yong-Kwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.2
    • /
    • pp.167-170
    • /
    • 1994
  • The surgical removal of the wisdom teeth is obligate when forceps extraction fails or when the wisdom teeth are impacted. The surgical removal of impacted maxillary third molars is a commonly performed procedure usually associated with few complications & little morbidity. The most frequent complications are tooth root fracture, maxillary tuberosity fracture, tooth displacement into the maxillary sinus & oroantral fistula formation. A rarely reported complication is the displacement of a tooth into the infratemporal fossa. The method of prevention of this complication is by the placement of either a finger or periosteal elevator posterior to the tooth during extraction. To remove the displaced upper third molar is very difficult & has many complications, e.g., persistent bleeding & nerve damage. When the wisdom teeth is displaced, it is initially necessary to gain access to bone by developing a mucoperiosteal path of delivery is developed by additional bone removal or, preferably planned sectioning of the tooth. There are many approaching techniques to remove the displaced upper third molar. This following report describes the surgical technique of displaced upper third molar in the pterygopalatine fassa by the midpalatal &transpharyngeal approach.

  • PDF

A useful additional medial subbrow approach for the treatment of medial orbital wall fracture with subciliary technique

  • Kim, Seung Min;Kim, Cheol Keun;Jo, Dong In;Lee, Myung Chul;Kim, Ji Nam;Choi, Hyun Gon;Shin, Dong Hyeok;Kim, Soon Heum
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.2
    • /
    • pp.101-108
    • /
    • 2019
  • Background: To date, a variety of surgical approaches have been used to reconstruct the medial orbital wall fracture. Still however, there is still a controversy as to their applicability because of postoperative scars, injury of anatomical structures and limited visual fields. The purpose of this study was to introduce a useful additional medial subbrow approach for better reduction and securement more accurate implant pocket of medial orbital wall fracture with the subciliary technique. Methods: We had performed our technique for a total of 14 patients with medial orbital wall fracture at our medical institution between January 2016 and July 2017. All fractures were operated through subciliary technique combined with the additional medial subbrow approach. They underwent subciliary approach accompanied by medial wall dissection using a Louisville elevator through the slit incision of the medial subbrow procedure. This facilitated visualization of the medial wall fracture site and helped to ensure a more accurate pocket for implant insertion. Results: Postoperative outcomes showed sufficient coverage without displacement. Twelve cases of preoperative diplopia improved to two cases of postoperative diplopia. More than 2 mm enophthalmos was 14 cases preoperatively, improving to 0 case postoperatively. Without damage such as major vessels or extraocular muscles, enophthalmos was corrected and there was no restriction of eyeball motion. Conclusion: Our ancillary procedure was useful in dissecting the medial wall, and it was a safe method as to cause no significant complications in our clinical series. Also, there is an only nonvisible postoperative scar. Therefore, it is a recommendable surgical modality for medial orbital wall fracture.

Effective Reduction of the Frontal Process of the Maxillary Fracture Segment Using Intermaxillary Fixation Screw (악간고정용 스크류를 이용한 위턱뼈 이마돌기 골절편의 효과적인 정복)

  • Moon, Suk-Ho;Lee, Woo-Sung;Lee, Jung-Ho;Rhie, Jong-Won;Ahn, Sang-Tae;Oh, Deuk-Young
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.555-558
    • /
    • 2011
  • Purpose: It is relatively unusual that infraorbital rim fracture is accompanied by nasal bone fracture. In order to correct effectively, subciliary approach and intranasal manipulation are applied simultaneously. But if reduction is not successful, intranasal manipulation may become aggressive and this often causes complications. We introduce a method using intermaxillary fixation screws for decreasing such complications and effective reduction of fracture. Methods: Total seven patients with fracture of frontal process of maxilla were treated with this method. The fracture site was exposed through the subciliary approach, and one or two screws were inserted into the displaced fracture fragment. During the traction of the screws using the wire, the fracture fragment was pushed upward from the intranasal side using an elevator supplementarily and fixed with a plate and the screws. Results: In all patients, the fracture fragment was reduced successfully and no complication occurred during one year's postoperative follow-up. Conclusion: When reduction cannot be attained through a bone hook or an elevator alone, reduction of fracture fragment can be done easily using intermaxillary fixation screws. This method is less likely to cause a mucosal injury because intranasal manipulation is not aggressive. Furthermore, as the screw can be inserted and removed easily, this method is considered effective not only for fracture of frontal process of maxilla but also for fractures in other regions.

Ultrasound-Guided Closed Reduction of Nasal Bone Fracture (초음파를 이용한 비골 골절의 비관혈적 정복술)

  • Yang, Hyung Eun;Park, Eun Soo;Cha, Jang Gyu;Kim, Cheol Han;Kim, Jun Hyuk;Kim, Yong Bae
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.461-465
    • /
    • 2007
  • Purpose: Nasal bone fracture may be the most common fracture among facial trauma. However, diagnosis and treatment tend to be overlooked while the reduction and maintenance of fragments remain complicated. Thus, the results are plagued with high rate of nasal deformity which leads cosmetic and functional discomfort. We took advantage of the fact that the nasal bone is one of the thinnest facial bone while at the same time being located close to the skin and utilized ultrasound in performing reduction of nasal bone. Methods:This method was performed on 25 patients with nasal bone fracture. The CL 15-7 linear array transducer (10-15MHz) ultrasound which provides a total of 7 views (3 axial views and 4 transverse views) of the elevator under the bony fragments was enough for the surgeon to accurately perform the reduction. Results: In our class, an accurate and precise reduction has been made possible by real time images before, during, and after the procedure with the help of ultrasound while reducing the exposure to radiation. Conclusion: Compared to previous methods, satisfaction of patients has increased in the nasal tip, minimal fracture of the side wall and secondary reduction cases. Therefore, the incorporation of ultrasound in the closed reduction of nasal bone may prove to be a useful method.

Inferomedially impacted zygomatic fracture reduction by reverse vector using an intraoral approach with Kirschner wire

  • Jang, Jin Woo;Cho, Jaeyoung;Burm, Jin Sik
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.69-74
    • /
    • 2021
  • Background In inferomedially rotated zygomatic fractures sticking in the maxillary sinus, it is often difficult to achieve complete reduction only by conventional intraoral reduction. We present a new intraoral reduction technique using a Kirschner wire and its clinical outcome. Methods Among 39 inferomedially impacted zygomatic fractures incompletely reduced by a simple intraoral reduction trial with a bone elevator, a Kirschner wire (1.5 mm) was vertically inserted from the zygomatic body to the lateral orbital rim in 17 inferior-dominant rotation fractures and horizontally inserted to the zygomatic arch in nine medial-dominant and 13 bidirectional rotation fractures. A Kirschner wire was held with a wire holder and lifted in the superolateral or anterolateral direction for reduction. Following reduction of the zygomaticomaxillary fracture, internal fixation was performed. Results Fractures were completely reduced using only an intraoral approach with Kirschner wire reduction in 33 cases and through an additional lower lid or transconjunctival incision in six cases. There were no surgical complications except in one patient with undercorrection. Postoperative 6-month computed tomography scans showed complete bone union and excellent bone alignment. Four patients experienced difficulty with upper lip elevation; however, these problems spontaneously resolved after manual tissue lump massage and intralesional steroid (Triamcinolone) injection. Conclusions We completely reduced infraorbital rim fractures, zygomaticomaxillary buttresses, and zygomaticofrontal suture fractures in 84% of patients through an intraoral approach alone. Intraoral Kirschner wire reduction may be a useful option by which to obtain effective and powerful reduction motion of an inferomedially rotated zygomatic body.