• Title/Summary/Keyword: reciprocating test

Search Result 140, Processing Time 0.025 seconds

Reciprocating sliding wear behavior of plastics against steel (플라스틱재료의 왕복동마찰마멸거동)

  • 김충현;안효석;정태형
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.35-41
    • /
    • 1999
  • Friction and wear test was performed for nylon, acetal resin, and PTFE(polytetrafluoroethylene) under reciprocating dry sliding conditions against a steel counterpart. Friction coefficient and specific wear rate were analysed as a function of sliding distance and applied load. The worn surfaces of plate and disc specimens were observed using SEM(Scanning Electron Microscopy). The experimental results show that acetal resin exhibited lowest wear rates whereas PTFE possessed lowest friction coefficient. The prominent wear mechanisms found were adhesion and abrasion.

  • PDF

Counter Weight Design of Multi-stage Reciprocating Air Compressors (다단 왕복동 공기압축기의 평형추 설계)

  • Kim, Young-Cheol;Kim, Byung-Ok;Shin, Hyun-Ik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.656-661
    • /
    • 2003
  • Modem reciprocating air compressors have tendency to a multi-stage W-type or V-type cylinder arrangement for the purpose of high outlet pressure, compactness and low vibration and noise. A valid counter weight calculation method using the complex expression is proposed for reducing the inertia forces of the compressor. Counter weight removes only 1st forward whirl component. Counter weight formulations are applied to the six various compressor structures which are (a) 1 cylinder single-throw crank shaft, (b) 2 cylinder single-throw crank shaft (c) 2 cylinder double-throw clank shaft, (d) 3 cylinder single-throw crank shaft, (e) 4 cylinder single-throw crank shaft and (f) 4 cylinder double-throw crank shaft. The improvement of performance is verified through available vibration test.

  • PDF

Reciprocating Wear Test of AISI 52100 Bearing Steel in h-BN-based Aqueous Lubricants

  • Gowtham Balasubramaniam;Dae-Hyun Cho
    • Tribology and Lubricants
    • /
    • v.39 no.6
    • /
    • pp.228-234
    • /
    • 2023
  • In this study, reciprocating wear tests are performed on AISI 52100 bearing steel to investigate its tribological behavior in a hexagonal boron nitride (h-BN) water solution. The h-BN-based aqueous lubricant is prepared using an atoxic procedure called ultrasonic sonication in pure water. Ball-on-flat reciprocating sliding experiments are conducted, where the ball is slewed on a fixed flat at 50-㎛ displacement. The lubricating behavior of h-BN is compared with that of deionized (DI) water. Results show that the friction coefficient is higher in h-BN testing than that in DI tests, but the results are equalized as the friction coefficient reaches a stable level. Scanning electron microscopic images reveal significant material loss in the center and mild abrasion on the edge of the wear scar in h-BN tests. However, these effects are minor in DI water situations. The results of energy-dispersive X-ray spectroscopy show that considerable oxidation occurs in the central zone of the wear scar in h-BN cases with strong adhesion and material removal. These findings reveal the importance of determining ideal circumstances that can tolerate material friction and wear.

Effects of Breath and Exhaust on the Performance of a Reciprocating Engine for Small Aircraft (소형항공기용 왕복엔진의 성능에 관한 흡/배기 영향)

  • 김근배;김근택;최선우
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.37-40
    • /
    • 2002
  • The engine performance test was carried out to investigate the effects of breath and exhaust on the performance of a reciprocating engine for small aircraft. In this test, three valves to control flow areas of a inlet and two outlets were used, the engine manifold pressure and the static thrust of propeller were measured in nine breath/exhaust conditions. Generally, small variations on the performance were showed as the test conditions were changed. The manifold pressure was increased as flow area of the inlet or the outlet was decreased in normal condition, however it was decreased as both flow areas were decreased. The static thrust of propeller was showed similar as the manifold pressure.

  • PDF

Effect of Sliding Speed on Wear Characteristics of Polyurethane Seal (미끄럼 속도 변화에 따른 폴리우레탄 씰의 마모 특성)

  • Kim, Hansol;Jeon, Hong Gyu;Chung, Koo-Hyun
    • Tribology and Lubricants
    • /
    • v.34 no.2
    • /
    • pp.49-54
    • /
    • 2018
  • Hydraulic reciprocating seal has been widely used to prevent fluid leakage in hydraulic systems. Also, hydraulic reciprocating seal plays a significant role to provide lubricant film at contacting interface to minimize tribological problems due to sliding with counter material. To predict lifetime of hydraulic reciprocating seal, quantitative understanding of wear characteristics with respect to operating conditions such as normal force and sliding speed is needed. In this work, effect of sliding speed on wear of polyurethane (PU) hydraulic reciprocating seal were experimentally investigated using a pin-on-disk tribo-tester. The wear characteristics of PU specimens were quantitatively determined by comparing the confocal microscope data before and after test. It was found that the wear rate of PU specimens decreased from $4.9{\times}10^{-11}mm^3$ to $1.1{\times}10^{-11}mm^3/Nm$ as sliding speed increased from 120 mm/s to 940 mm/s. Also, it was observed that the friction decreased slightly as the sliding speed increased. Improvement of lubrication state with increasing sliding speed was likely to be responsible for this enhanced friction and wear characteristics. This result also suggests that decrease in sliding distance between PU elastomer and counter materials at lower sliding speed is preferred. Furthermore, the quantitative assessment of wear characteristics of PU specimen may be useful in prediction of lifetime of PU hydraulic reciprocating seal if the allowed degree of wear for failure of the seal is provided.

Comparison vibration characteristics of several wireless endodontic handpieces (여러 근관치료용 무선 핸드피스의 진동양상 비교)

  • Lee, Bo-Kyung;Lee, Yoon;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.81-89
    • /
    • 2022
  • Purpose: Wireless endodontic handpieces (WEH) are widely used in dental clinics due to their convenience and portability. This study aimed to compare the vibration magnitudes and patterns generated by five WEH. Materials and Methods: Vibration acceleration of five WEH (X-Smart IQ, E connect S, Endo A Class, ENDOIT, and TRAUS ENDO) in the rotary and reciprocating motion was measured with accelerometer The average vibration acceleration was analyzed using the t-test, Welch's ANOVA test, and Dunnett T3 test at P < 0.05. Results: In all WEH, the average vibration acceleration in reciprocating motion was significantly higher than that in rotary motion (P < 0.001). In rotary motion, repeated vibration graphs of constant amplitude were obtained without sudden changes in the magnitude of vibration, and the average vibration acceleration value was high in the order of X Smart IQ, Endo A Class, ENDOIT, E Connect S, and TRAUS ENDO (P < 0.001), there was no statistically significant difference between X Smart IQ and Endo A Class. In reciprocating motion, a vibration graph was obtained in which large amplitude peaks appear at specific points within one cycle are repeated. The average vibration acceleration value was highest in the order of X Smart IQ, E Connect S, Endo A class, ENDOIT, and TRAUS ENDO (P < 0.001). Conclusion: Regardless of the type of WEH, greater vibration occurred in the reciprocating motion than in the rotary motion (P < 0.001). In the reciprocating motion, there was a difference in vibration for all handpieces (P < 0.001).

A Numerical Study on Heat Transfer in a Reciprocating Compressor for a Domestic Refrigerator (소형 냉장고용 왕복동식 압축기의 열전달에 관한 수치해석 연구)

  • Sim Yun-Hee;Youn Young;Park Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.377-385
    • /
    • 2005
  • An analytical model was developed using the lumped mass parameter method to estimate temperature distribution of metal parts and refrigerant of the hermetic reciprocating compressor, All of the lumped mass has been equated with the first law of thermodynamics. In the delivered equation, correlations of heat transfer coefficient in the heat transfer equation were taken from open literature. The equations are solved by Gauss-Jordan method simultaneously. To verify the developed numerical program, an experiment was conducted with a domestic refrigerator. The compressor which had been installed at the bottom of the experimental refrigerator was modified to measure internal temperature. Model verification test was conducted at $30^{\circ}C$ outdoor temperature with variation of compressor cooling conditions. As a result, there is a good consistency between calculated temperature and measured one.

Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation (왕복운동 및 회전운동 근관성형용 전동모터 간의 진동 양상 비교)

  • Jeon, Yeong-Ju;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee;Chang, Hoon-Sang
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.734-743
    • /
    • 2014
  • Objectives: By introduced reciprocation motion file in dentistry, dentists benefit simple canal shaping procedure and time-saving. But, reciprocation motion generates uncomfortable vibration to doctors and patients. Because there was no study about this consideration, this study compared vibration pattern and power generated from reciprocation motion motor and conventional rotary motor. Materials & Methods: One conventional rotary motor; X-Smart (Dentsply Maillefer, Ballaigues, Switzerland); and two reciprocating motors; WaveOne Motor (Dentsply Maillefer, Ballaigues, Switzerland) and X-SMART PLUS (Dentsply Maillefer, Ballaigues, Switzerland); were used in this study. Triaxial $ICP^{(R)}$ Accelerometer (Model 356A12, PCB piezotronics, New York, USA) was attached on motor's handpiece head, and was measured tri-axial vibratory acceleration with NI Sound and Vibration Assistant 2009 software (National Instruments, Texas, USA). Mean vibratory acceleration and maximum vibratory acceleration was measured on fixed position and handed position. The results of vibratory acceleration were statistically analyzed using ANOVA and multiple comparisons are made using Turkey's test at p<0.05 level. Results: Reciprocating motors showed higher mean vibratory acceleration and maximum vibratory acceleration than conventional rotary motor (p<0.05). Between reciprocating motors, X-SMART PLUS had lower mean vibratory acceleration and maximum vibratory acceleration than WaveOne Motor (p<0.05). Conclusion: Reciprocating motors generate more vibration than conventional rotary motor. Further study about effect of vibration to dentist and patient is needed. And it seems to be necessary to make a standard about vibration level in endodontic motors.

Preference of undergraduate students after first experience on nickel-titanium endodontic instruments

  • Kwak, Sang Won;Cheung, Gary Shun-Pan;Ha, Jung-Hong;Kim, Sung Kyo;Lee, Hyojin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.176-181
    • /
    • 2016
  • Objectives: This study aimed to compare two nickel-titanium systems (rotary vs. reciprocating) for their acceptance by undergraduate students who experienced nickel-titanium (NiTi) instruments for the first time. Materials and Methods: Eighty-one sophomore dental students were first taught on manual root canal preparation with stainless-steel files. After that, they were instructed on the use of ProTaper Universal system (PTU, Dentsply Maillefer), then the WaveOne (WO, Dentsply Maillefer). They practiced with each system on 2 extracted molars, before using those files to shape the buccal or mesial canals of additional first molars. A questionnaire was completed after using each file system, seeking students' perception about 'Ease of use', 'Flexibility', 'Cutting-efficiency', 'Screwing-effect', 'Feeling-safety', and 'Instrumentation-time' of the NiTi files, relative to stainless-steel instrumentation, on a 5-point Likert-type scale. They were also requested to indicate their preference between the two systems. Data was compared between groups using t-test, and with Chi-square test for correlation of each perception value with the preferred choice (p = 0.05). Results: Among the 81 students, 55 indicated their preferred file system as WO and 22 as PTU. All scores were greater than 4 (better) for both systems, compared with stainless-steel files, except for 'Screwing-effect' for PTU. The scores for WO in the categories of 'Flexibility', 'Screwing-effect', and 'Feeling-safety' were significantly higher scores than those of PTU. A significant association between the 'Screwing-effect' and students' preference for WO was observed. Conclusions: Novice operators preferred nickel-titanium instruments to stainless-steel, and majority of them opted for reciprocating file instead of continuous rotating system.