• Title/Summary/Keyword: real-time probe

Search Result 231, Processing Time 0.024 seconds

Rapid Detection and Monitoring Therapeutic Efficacy of Mycobacterium tuberculosis Complex Using a Novel Real-Time Assay

  • Jiang, Li Juan;Wu, Wen Juan;Wu, Hai;Ryang, Son Sik;Zhou, Jian;Wu, Wei;Li, Tao;Guo, Jian;Wang, Hong Hai;Lu, Shui Hua;Li, Yao
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.9
    • /
    • pp.1301-1306
    • /
    • 2012
  • We combined real-time RT-PCR and real-time PCR (R/P) assays using a hydrolysis probe to detect Mycobacterium tuberculosis complex (MTBC)-specific 16S rRNA and its rRNA gene (rDNA). The assay was applied to 28 non-respiratory and 207 respiratory specimens from 218 patients. Total nucleic acids (including RNA and DNA) were extracted from samples, and results were considered positive if the repeat RT-PCR threshold cycle was ${\leq}35$ and the ratio of real-time RT-PCR and real-time PCR load was ${\geq}1.51$. The results were compared with those from existing methods, including smear, culture, and real-time PCR. Following resolution of the discrepant results between R/P assay and culture, the overall sensitivity, specificity, positive predictive values (PPV), and negative predictive values (NPV) of all samples (including non-respiratory and respiratory specimens) were 98.2%, 97.2%, 91.7%, and 99.4%, respectively, for R/P assay, and 83.9%, 89.9%, 72.3%, and 94.7%, respectively, for real-time PCR. Furthermore, the R/P assay of four patient samples showed a higher ratio before treatment than after several days of treatment. We conclude that the R/P assay is a rapid and accurate method for direct detection of MTBC, which can distinguish viable and nonviable MTBC, and thus may guide patient therapy and public health decisions.

Development of Real-time PCR Assay Based on Hydrolysis Probe for Detection of Epichloë spp. and Toxic Alkaloid Synthesis Genes

  • Lee, Ki-Won;Woo, Jae Hoon;Song, Yowook;Rahman, Md Atikur;Lee, Sang-Hoon
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.42 no.3
    • /
    • pp.201-207
    • /
    • 2022
  • Fescues, which are widely cultivated as grasses and forages around the world, are often naturally infected with the endophyte, Epichloë. This fungus, transmitted through seeds, imparts resistance to drying and herbivorous insects in its host without causing any external damage, thereby contributing to the adaptation of the host to the environment and maintaining a symbiosis. However, some endophytes, such as E. coenophialum synthesize ergovaline or lolitrem B, which accumulate in the plant and impart anti-mammalian properties. For example, when livestock consume excessive amounts of grass containing toxic endophytes, problems associated with neuromuscular abnormalities, such as convulsions, paralysis, high fever, decreased milk production, reproductive disorders, and even death, can occur. Therefore, pre-inoculation with non-toxic endogenous fungi or management with endophyte-free grass is important in preventing damage to livestock and producing high-quality forage. To date, the diagnosis of endophytes has been mainly performed by observation under a microscope following staining, or by performing an immune blot assay using a monoclonal antibody. Recently, the polymerase chain reaction (PCR)-based molecular diagnostic method is gaining importance in the fields of agriculture, livestock, and healthcare given the method's advantages. These include faster results, with greater accuracy and sensitivity than those obtained using conventional diagnostic methods. For the diagnosis of endophytes, the nested PCR method is the only available option developed; however, it is limited by the fact that the level of toxic alkaloid synthesis cannot be estimated. Therefore, in this study, we aimed to develop a triplex real-time PCR diagnostic method that can determine the presence or absence of endophyte infection using DNA extracted from seeds within 1 h, while simultaneously detecting easD and LtmC genes, which are related to toxic alkaloid synthesis. This new method was then also applied to real field samples.

A Link Travel Time Estimation Algorithm Based on Point and Interval Detection Data over the National Highway Section (일반국도의 지점 및 구간검지기 자료의 융합을 통한 통행시간 추정 알고리즘 개발)

  • Kim, Sung-Hyun;Lim, Kang-Won;Lee, Young-Ihn
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.5 s.83
    • /
    • pp.135-146
    • /
    • 2005
  • Up to now studies on the fusion of travel time from various detectors have been conducted based on the variance raito of the intermittent data mainly collected by GPS or probe vehicles. The fusion model based on the variance ratio of intermittent data is not suitable for the license plate recognition AVIs which can deal with vast amount of data. This study was carried out to develop the fusion model based on travel time acquired from the license plate recognition AVIs and the point detectors. In order to fuse travel time acquired from the point detectors and the license plate recognition AVIs, the optimized fusion model and the proportional fusion model were developed in this study. As a result of verification, the optimized fusion model showed the superior estimation performance. The optimized fusion model is the dynamic fusion ratio estimation model on real time base, which calculates fusion weights based on real time historic data and applies them to the current time period. The results of this study are expected to be used effectively for National Highway Traffic Management System to provide traffic information in the future. However, there should be further studies on the Proper distance for the establishment of the AVIs and the license plate matching rate according to the lanes for AVIs to be established.

A Display System of Realtime 3D Bathymetry Using Remote Sensing Exploration and Cloud Computing Technologies (원격탐사와 클라우드 컴퓨팅 기술을 활용한 실시간 3D 해저지형의 디스플레이 시스템)

  • Lee, Jong-Hoon;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.2
    • /
    • pp.152-159
    • /
    • 2014
  • Recently. utilization of remote sensing exploration and cloud computing has been extended to efficient measurement, store, and update of bathymetry map data according to cloud computing technology. In the field of real ocean, water depth measurements and measurement data management, distribution, and display equipment for the development and dissemination have generated a lot of time and cost. To improve these problems, through real-time three-dimensional display system at this location, we can determine the importance of measurement activities, and reduce the time and cost of measurement activities. Data measured from marine probe vessels and remote sensing exploration equipments and other various channels can be handled and managed. In this paper, we propose a realtime three-dimensional display system through the depth measurements from remote sensing exploration. The proposed real-time three-dimensional display system can be effectively applied in the field of measurement of the topographical survey of the land as well as bathymetry of the sea.

The Usefulness of Ultrasound Diagnosis of Acute Tendon Injury in Hand (급성 건 손상 환자에서 초음파의 유용성)

  • Choi, Chang Yong;Lee, Han Jeong;Choi, Hwan Jun;Kim, Mi Sun
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.729-734
    • /
    • 2008
  • Purpose: The evaluation and management of a completely transected tendon of the hand is relatively clear. In most cases, the integrity is assessed by physical examination(eg, broken normal cascade, motion loss) but occasionally, It happens in troubles. because of pain, limited patient cooperation(eg, child, unconscious patient), and other associated injuries(eg, fractures, foreign bodies). Methods: From september 2006 to August 2007, 28 patients were evaluated with real time ultrasonography preoperatively and postoperatively. Twenty eight patients with injured tendon were evaluated using an HDI 5000 Sono CT(Philips Medical Systems, Bothell, WA) machine with a high resolution, 7.5MHz hockey stick linear probe. Dynamic evaluation was performed in real time. Results: Surgery was performed after the ultrasonographic evaluation. Sonographic diagnosis and intraoperative findings were correlated. Ultrasonographic findings show tendon discontinuity, gaps, and fluid collection. Conclusion: We conclude that ultrasonography is helpful in evaluating and managing acute tendon injury. Especially, in cases of completely lacerated tendon, ultrasonography can identify the location of the proximal tendon stump and partial lacerated tendon, ultrasonographic diagnostic tool can decrease misdiagnosis.

Determination of Cytoplasmic Male Sterile Factors in Onion Plants (Allium cepa L.) Using PCR-RFLP and SNP Markers

  • Cho, Kwang-Soo;Yang, Tae-Jin;Hong, Su-Young;Kwon, Young-Seok;Woo, Jong-Gyu;Park, Hyo-Guen
    • Molecules and Cells
    • /
    • v.21 no.3
    • /
    • pp.411-417
    • /
    • 2006
  • We have developed a polymerase chain reactionrestriction fragment length polymorphism (PCR-RFLP) marker that can distinguish male-fertile (N) and male-sterile (S) cytoplasm in onions. The PCR-RFLP marker was located in a chloroplast psbA gene amplicon. Digesting the amplicons from different cytoplasm-containing varieties with the restriction enzyme MspI revealed that N-cytoplasm plants have a functional MspI site (CCGG), whereas the S-cytoplasm plants has a substitution in that site (CTGG), and thus no MspI target. The results obtained using this PCR-RFLP marker to distinguish between cytoplasmic male sterile factors in 35 onion varieties corresponded with those using a CMS-specific sequence-characterized amplified region (SCAR) marker. Moreover, the PCR-RFLP marker can identify N- ot S-cytoplasms in DNA sample mixtures in which they are in up to a 10-fold minority, indicating that use of the marker has high diagnostic precision. We also demonstrated the usefulness of the SNP detected in the psbA gene for high-throughput discrimination of CMS factors using Real-time PCR and a TaqMan probe assay.

Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices (집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정)

  • Doh, Il;Joe, Daniel J.;Kim, Sung Mok;Baik, Kyung Min;Kim, Yong Tae;Park, Seung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

An optical sensor of a probing system for inspection of PCBs (인쇄회로기판 검사용 프로브시스템의 광학센서)

  • 심재홍;조형석;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1742-1745
    • /
    • 1997
  • We have developed a highly responsible probing system for inspection of electrical properties of assemble PCB$_{s}$ (printed circuit boards). However, as the duration of the impact occurring between a probe and a solder joint on PCB is very short, it is very difficult to control the harmful peak impact force and the slip motion of the probe to sufficient level only by its vorce feedback control with high gains. To overcome these disadvantages of the prototype, it needs ot obtain some information of the solder joint in advance before the contact. In addition, to guarantee the reliability of the probing task, the probing system is required to measure several points around the probale target point at high speed. There fore, to meet such requirements, we propose a new noncontaet sensor capable of detecting simultaneously position and normal vectors of the multiple points around the probable target point in real time. By using this information, we can prepare a control strategy for stable contact motion on impact. In this paper, we described measuring priniciple, design, and development of the sensor. The effectiveness of the proposed sensor is verified through a series of experiments.s.

  • PDF

Ultrasonographic Evaluation of the External Ear Canal in Dogs (개에서 외이도의 초음파학적 평가)

  • 이해운;엄기동;성윤상;이정민;이종원;김정은;장광호;이근우;장동우
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.149-153
    • /
    • 2004
  • This study was to determine the procedure for ultrasonographic imaging of the canine external ear canal(ECC). By infusion of warm saline solution into the ear canal, a real-time B mode ultrasonographic examination of the ECC was performed in five healthy Beagle dogs and two dogs with severe otitis externa. The ultrasonography was very useful to detect the structures of the ECC and the tympanic membrane. An 11 NHz linear probe was permitted to assess an anechoic lumen of the ECC and a hyperechoic cartilage surrounding the ear canal. In two dogs with otitis externa, it could be assessed the ECC with ultrasonography without ear cleansing. A lumen of the ECC was irregular and a cerumen could be seen, but edematous inflammatory changes of the ECC could not be identified. The results suggest that ultrasonography of the ECC with an 11 NHz linear probe after infusing the saline solution into the ear canal may be an accurate, non-invasive, rapid, and widely available method for assessment of the ear canal diseases such as otitis externa, polyp, stenosis, hyperplasia, and foreign body in dogs.

Utilizing Natural and Engineered Peroxiredoxins As Intracellular Peroxide Reporters

  • Laer, Koen Van;Dick, Tobias P.
    • Molecules and Cells
    • /
    • v.39 no.1
    • /
    • pp.46-52
    • /
    • 2016
  • It is increasingly apparent that nature evolved peroxiredoxins not only as $H_2O_2$ scavengers but also as highly sensitive $H_2O_2$ sensors and signal transducers. Here we ask whether the $H_2O_2$ sensing role of Prx can be exploited to develop probes that allow to monitor intracellular $H_2O_2$ levels with unprecedented sensitivity. Indeed, simple gel shift assays visualizing the oxidation of endogenous 2-Cys peroxiredoxins have already been used to detect subtle changes in intracellular $H_2O_2$ concentration. The challenge however is to create a genetically encoded probe that offers real-time measurements of $H_2O_2$ levels in intact cells via the Prx oxidation state. We discuss potential design strategies for Prx-based probes based on either the redoxsensitive fluorophore roGFP or the conformation-sensitive fluorophore cpYFP. Furthermore, we outline the structural and chemical complexities which need to be addressed when using Prx as a sensing moiety for $H_2O_2$ probes. We suggest experimental strategies to investigate the influence of these complexities on probe behavior. In doing so, we hope to stimulate the development of Prx-based probes which may spearhead the further study of cellular $H_2O_2$ homeostasis and Prx signaling.