• 제목/요약/키워드: real time measurement

검색결과 2,178건 처리시간 0.033초

Quality of Anticoagulation and Treatment Satisfaction in Patients with Non-Valvular Atrial Fibrillation Treated with Vitamin K Antagonist: Result from the KORean Atrial Fibrillation Investigation II

  • Oh, Seil;Kim, June-Soo;Oh, Yong-Seog;Shin, Dong-Gu;Pak, Hui-Nam;Hwang, Gyo-Seung;Choi, Kee-Joon;Kim, Jin-Bae;Lee, Man-Young;Park, Hyung-Wook;Kim, Dae-Kyeong;Jin, Eun-Sun;Park, Jaeseok;Oh, Il-Young;Shin, Dae-Hee;Park, Hyoung-Seob;Kim, Jun Hyung;Kim, Nam-Ho;Ahn, Min-Soo;Seo, Bo-Jeong;Kim, Young-Joo;Kang, Seongsik;Lee, Juneyoung;Kim, Young-Hoon
    • Journal of Korean Medical Science
    • /
    • 제33권49호
    • /
    • pp.323.1-323.12
    • /
    • 2018
  • Background: Vitamin K antagonist (VKA) to prevent thromboembolism in non-valvular atrial fibrillation (NVAF) patients has limitations such as drug interaction. This study investigated the clinical characteristics of Korean patients treated with VKA for stroke prevention and assessed quality of VKA therapy and treatment satisfaction. Methods: We conducted a multicenter, prospective, non-interventional study. Patients with $CHADS_2{\geq}1$ and treated with VKA (started within the last 3 months) were enrolled from April 2013 to March 2014. Demographic and clinical features including risk factors of stroke and VKA treatment information was collected at baseline. Treatment patterns and international normalized ratio (INR) level were evaluated during follow-up. Time in therapeutic range (TTR) > 60% indicated well-controlled INR. Treatment satisfaction on the VKA use was measured by Treatment Satisfaction Questionnaire for Medication (TSQM) after 3 months of follow-up. Results: A total of 877 patients (age, 67; male, 60%) were enrolled and followed up for one year. More than half of patients (56%) had $CHADS_2{\geq}2$ and 83.6% had $CHA_2DS_2-VASc{\geq}2$. A total of 852 patients had one or more INR measurement during their follow-up period. Among those patients, 25.5% discontinued VKA treatment during follow-up. Of all patients, 626 patients (73%) had poor-controlled INR (TTR < 60%) measure. Patients' treatment satisfaction measured with TSQM was 55.6 in global satisfaction domain. Conclusion: INR was poorly controlled in Korean NVAF patients treated with VKA. VKA users also showed low treatment satisfaction.

EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰 (Review on Usefulness of EPID (Electronic Portal Imaging Device))

  • 이충원;박도근;최아현;안종호;송기원
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.57-67
    • /
    • 2013
  • 목 적: 방사선 치료 중 정확한 환자의 셋업 확인과 선량 측정용으로 사용되었던 film을 대신 하여 현재는 전자포탈영상장치(EPID)가 장착된 장비가 증가하고 있다. 이에 본 논문은 전자포탈영상장치 사용 시 자세확인의 정확성과 선량측정의 유용성을 평가해 보고자 한다. 대상 및 방법: 대한방사선치료학회, 대한방사선종양학회, Pubmed에서 "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", "In vivo dosimetry"와 같은 용어로 검색하여 획득한 50개의 자료(1997~2012)를 대상으로 EPID의 역사와 선량측정(dosimetry), 자세확인(set-up verification), EPID 특성으로 구분하여 EPID의 유용성을 분석 하였다. 결 과: EPID는 1세대 Liquid-filled ionization chamber, 2세대 Camera based fluroscopic, 3세대 Amorphous-silicon 순으로 발전하였으며, EPID 촬영 모드에는 크게 EPID mode, Cine mode, Integrated mode로 나뉜다. 필름과 EPID의 절대선량정확성 평가를 한 결과 EPID는 1%, EDR2 필름은 3% 이내로 나타나 오차 측정 정확도가 필름에 비해 EPID가 우수하다는 것을 알 수 있었고, 치료계획 시스템으로부터 계산된 기준 조사면과 EDR2 필름, EPID로 측정한 기준 조사면의 선량 분포를 중첩하여 감마 분석한 결과 필름과 EPID 모두 허용기준 3%/3 mm와 2%/2 mm에서 감마값이 1을 초과하는 화소(r%>1)가 전체 화소의 2% 이내였다. 또한 업무 부하 비교에 있어 세기조절방사선 치료에서 전 과정 QA를 수행하는데 소요되는 시간은 EDR2 필름이 약 110분, EPID가 약 55분으로 측정되었다. 결 론: 전자포탈영상장치의 이용은 선량측정과 자세확인에 있어 기존의 복잡하고 번거로웠던 film과 전리조(Ionization chamber)를 대체하기에 충분하였으며, 특히 세기조절방사선치료의 정도관리에 있어 매우 유용하고 효율적이며 정확한 선량 측정 장치임을 알 수 있었다. 또한, 전자포탈영상장치를 이용한 Cine mode 촬영은 횡격막의 움직임에 따라 유동성이 큰 폐와 간의 경우나 자세의 안정성이 불안한 직장암 환자의 경우 추가 선량 없이 실시간으로 종양의 위치를 확인 할 수 있다는 장점이 있어 최적의 방사선 치료 구현이 가능하리라 사료된다.

  • PDF

Perceptional Change of a New Product, DMB Phone

  • Kim, Ju-Young;Ko, Deok-Im
    • 마케팅과학연구
    • /
    • 제18권3호
    • /
    • pp.59-88
    • /
    • 2008
  • Digital Convergence means integration between industry, technology, and contents, and in marketing, it usually comes with creation of new types of product and service under the base of digital technology as digitalization progress in electro-communication industries including telecommunication, home appliance, and computer industries. One can see digital convergence not only in instruments such as PC, AV appliances, cellular phone, but also in contents, network, service that are required in production, modification, distribution, re-production of information. Convergence in contents started around 1990. Convergence in network and service begins as broadcasting and telecommunication integrates and DMB(digital multimedia broadcasting), born in May, 2005 is the symbolic icon in this trend. There are some positive and negative expectations about DMB. The reason why two opposite expectations exist is that DMB does not come out from customer's need but from technology development. Therefore, customers might have hard time to interpret the real meaning of DMB. Time is quite critical to a high tech product, like DMB because another product with same function from different technology can replace the existing product within short period of time. If DMB does not positioning well to customer's mind quickly, another products like Wibro, IPTV, or HSPDA could replace it before it even spreads out. Therefore, positioning strategy is critical for success of DMB product. To make correct positioning strategy, one needs to understand how consumer interprets DMB and how consumer's interpretation can be changed via communication strategy. In this study, we try to investigate how consumer perceives a new product, like DMB and how AD strategy change consumer's perception. More specifically, the paper segment consumers into sub-groups based on their DMB perceptions and compare their characteristics in order to understand how they perceive DMB. And, expose them different printed ADs that have messages guiding consumer think DMB in specific ways, either cellular phone or personal TV. Research Question 1: Segment consumers according to perceptions about DMB and compare characteristics of segmentations. Research Question 2: Compare perceptions about DMB after AD that induces categorization of DMB in direction for each segment. If one understand and predict a direction in which consumer perceive a new product, firm can select target customers easily. We segment consumers according to their perception and analyze characteristics in order to find some variables that can influence perceptions, like prior experience, usage, or habit. And then, marketing people can use this variables to identify target customers and predict their perceptions. If one knows how customer's perception is changed via AD message, communication strategy could be constructed properly. Specially, information from segmented customers helps to develop efficient AD strategy for segment who has prior perception. Research framework consists of two measurements and one treatment, O1 X O2. First observation is for collecting information about consumer's perception and their characteristics. Based on first observation, the paper segment consumers into two groups, one group perceives DMB similar to Cellular phone and the other group perceives DMB similar to TV. And compare characteristics of two segments in order to find reason why they perceive DMB differently. Next, we expose two kinds of AD to subjects. One AD describes DMB as Cellular phone and the other Ad describes DMB as personal TV. When two ADs are exposed to subjects, consumers don't know their prior perception of DMB, in other words, which subject belongs 'similar-to-Cellular phone' segment or 'similar-to-TV' segment? However, we analyze the AD's effect differently for each segment. In research design, final observation is for investigating AD effect. Perception before AD is compared with perception after AD. Comparisons are made for each segment and for each AD. For the segment who perceives DMB similar to TV, AD that describes DMB as cellular phone could change the prior perception. And AD that describes DMB as personal TV, could enforce the prior perception. For data collection, subjects are selected from undergraduate students because they have basic knowledge about most digital equipments and have open attitude about a new product and media. Total number of subjects is 240. In order to measure perception about DMB, we use indirect measurement, comparison with other similar digital products. To select similar digital products, we pre-survey students and then finally select PDA, Car-TV, Cellular Phone, MP3 player, TV, and PSP. Quasi experiment is done at several classes under instructor's allowance. After brief introduction, prior knowledge, awareness, and usage about DMB as well as other digital instruments is asked and their similarities and perceived characteristics are measured. And then, two kinds of manipulated color-printed AD are distributed and similarities and perceived characteristics for DMB are re-measured. Finally purchase intension, AD attitude, manipulation check, and demographic variables are asked. Subjects are given small gift for participation. Stimuli are color-printed advertising. Their actual size is A4 and made after several pre-test from AD professionals and students. As results, consumers are segmented into two subgroups based on their perceptions of DMB. Similarity measure between DMB and cellular phone and similarity measure between DMB and TV are used to classify consumers. If subject whose first measure is less than the second measure, she is classified into segment A and segment A is characterized as they perceive DMB like TV. Otherwise, they are classified as segment B, who perceives DMB like cellular phone. Discriminant analysis on these groups with their characteristics of usage and attitude shows that Segment A knows much about DMB and uses a lot of digital instrument. Segment B, who thinks DMB as cellular phone doesn't know well about DMB and not familiar with other digital instruments. So, consumers with higher knowledge perceive DMB similar to TV because launching DMB advertising lead consumer think DMB as TV. Consumers with less interest on digital products don't know well about DMB AD and then think DMB as cellular phone. In order to investigate perceptions of DMB as well as other digital instruments, we apply Proxscal analysis, Multidimensional Scaling technique at SPSS statistical package. At first step, subjects are presented 21 pairs of 7 digital instruments and evaluate similarity judgments on 7 point scale. And for each segment, their similarity judgments are averaged and similarity matrix is made. Secondly, Proxscal analysis of segment A and B are done. At third stage, get similarity judgment between DMB and other digital instruments after AD exposure. Lastly, similarity judgments of group A-1, A-2, B-1, and B-2 are named as 'after DMB' and put them into matrix made at the first stage. Then apply Proxscal analysis on these matrixes and check the positional difference of DMB and after DMB. The results show that map of segment A, who perceives DMB similar as TV, shows that DMB position closer to TV than to Cellular phone as expected. Map of segment B, who perceive DMB similar as cellular phone shows that DMB position closer to Cellular phone than to TV as expected. Stress value and R-square is acceptable. And, change results after stimuli, manipulated Advertising show that AD makes DMB perception bent toward Cellular phone when Cellular phone-like AD is exposed, and that DMB positioning move towards Car-TV which is more personalized one when TV-like AD is exposed. It is true for both segment, A and B, consistently. Furthermore, the paper apply correspondence analysis to the same data and find almost the same results. The paper answers two main research questions. The first one is that perception about a new product is made mainly from prior experience. And the second one is that AD is effective in changing and enforcing perception. In addition to above, we extend perception change to purchase intention. Purchase intention is high when AD enforces original perception. AD that shows DMB like TV makes worst intention. This paper has limitations and issues to be pursed in near future. Methodologically, current methodology can't provide statistical test on the perceptual change, since classical MDS models, like Proxscal and correspondence analysis are not probability models. So, a new probability MDS model for testing hypothesis about configuration needs to be developed. Next, advertising message needs to be developed more rigorously from theoretical and managerial perspective. Also experimental procedure could be improved for more realistic data collection. For example, web-based experiment and real product stimuli and multimedia presentation could be employed. Or, one can display products together in simulated shop. In addition, demand and social desirability threats of internal validity could influence on the results. In order to handle the threats, results of the model-intended advertising and other "pseudo" advertising could be compared. Furthermore, one can try various level of innovativeness in order to check whether it make any different results (cf. Moon 2006). In addition, if one can create hypothetical product that is really innovative and new for research, it helps to make a vacant impression status and then to study how to form impression in more rigorous way.

  • PDF

간암 환자의 세기조절방사선치료 시 호흡에 의한 움직임 조건에서 측정된 조사면 별 선량결과를 기반으로 재계산한 체내 선량분포 평가 (Evaluation of Dose Distributions Recalculated with Per-field Measurement Data under the Condition of Respiratory Motion during IMRT for Liver Cancer)

  • 송주영;김용협;정재욱;윤미선;안성자;정웅기;남택근
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.79-88
    • /
    • 2014
  • 내부표적체적을 기반으로 계획된 간암 환자의 세기조절방사선치료에서 호흡에 의한 장기의 움직임 영향을 적용하여 체내 실제 종양 부피와 중요 장기 부피에서의 선량분포를 재계산하고, 호흡동조 방식의 세기조절방사선치료 계획 결과와 비교를 통한 선량적 특성을 분석하였다. 내부표적체적은 MIM 프로그램을 사용하여 형성하였고, 호흡에 의한 장기 움직임을 모사할 수 있는 구동 팬텀을 사용하였다. 체내 선량분포는 세기조절방사선치료의 품질보증 과정에서 2차원 다이오드 검출기 배열 장치인 MapCHECK2로 측정한 조사면 별 측정 결과를 기반으로 3DVH 프로그램으로 재계산 하였다. 내부표적체적 기반의 세기조절방사선치료 수행 시 계획표적체적에 충분히 처방선량이 조사되었지만, 선량의 균일도는 호흡동조 방식의 세기조절방사선치료와 비교 시 열등한 결과를 보였다. 상대적으로 더 큰 조사면을 사용하는 내부표적체적 기반의 세기조절방사선치료에서 손상위험장기체적에 더 높은 선량이 조사됨을 확인할 수 있었지만, 척수에 증가된 선량은 부작용 발생확률에 큰 영향을 주지 않는 적은 양이었고, 정상 간이나 신장 부위의 증가된 선량도 최적화 과정에서 좀 더 선량감소 조건을 강화한다면 큰 영향이 없을 것으로 평가되었다. 호흡동조 방식의 세기조절방사선치료가 치료계획에서는 더 좋은 선량분포를 보이고 있으나, 실제 구현 과정에서 다엽콜리메이터의 움직임 오류로 인한 선량의 오차와 치료시간의 증가 측면의 단점이 있으므로, 환자 호흡 상태 및 손상위험장기의 선량제한 값에 대한 사전 분석을 통해 환자 별 최적의 세기조절방사선치료 기법을 선정하여 적용하는 것이 타당하다고 생각된다.

국가중요시설 경비원의 직무여건과 직무만족도의 관계 (The relationship of the office given condition of the country important facility private security and job satisfaction degree)

  • 손기호
    • 시큐리티연구
    • /
    • 제33호
    • /
    • pp.103-135
    • /
    • 2012
  • 본 연구는 국가중요시설 경비원의 직무여건 실태와 직무만족도의 관계를 알아보는데 목적이 있다. 국가중요시설 경비원들의 실상을 직접적으로 파악 분석하고자 통상적인 측정도구인 설문지를 활용하여 부산과 울산지역의 국가중요시설인 공항 및 항만지역과 일반사업장에 근무 중인 경비원을 대상으로 하였다. 시설주 및 경비업체 담당자에게 충분한 설문취지를 설명하고 문항을 사전 검토하였고 총400부를 배포하였으며 이중 논제의도와 부적합한 설문지를 제외한 331부(82.8%)를 분석에 활용하였다. 수집된 자료의 통계처리는 데이터코딩과 클리닝과정을 거쳐 SPSS version 15.0 통계패키지 프로그램을 활용하여 빈도분석, 신뢰도분석, t-test, 일원변량분석, 상관관계분석, 회귀분석을 실시하였다. 국가중요시설에 대한 경비원의 직무여건 실태와 직무만족도의 관계를 대인관계, 직무특성, 직무환경, 보수 요인으로 구분하고 일반적인 특성에 따른 직무만족도의 차이를 검증하였다. 이상의 연구방법을 통하여 얻은 결론을 보면 일반적인 경향은 저임금과 열악한 현장 환경은 지속되고 있었다. 일반적인 특성에서 남자가 여자보다 직무만족 수준이 높았고, 연령은 많고 학력은 낮을수록 높았으며, 경력과 소득이 많을수록, 시설보안요원보다 청원경찰이나 검색 및 안내요원이 높았고 입사 전 학생인 경우가 가장 낮게 회사원과 기타 직업군이 비교적 높은 직무만족도를 보였다. 상관관계 분석결과 직무만족이 높을수록 이직의사는 낮아지고 조직몰입도는 증가했다. 회귀분석결과 직무만족도가 이직의사와 조직몰입에 유의미한 영향을 미치는 것으로 나타났고, 직무특성과 직무환경 수준이 낮을수록 이직의사에 영향을 미쳤고, 직무특성에 대한 만족도와 대인관계, 보수, 직무환경 수준이 높을수록 조직몰입에 영향을 미쳤다. 금번의 연구결과를 종합하면 국가중요시설 경비인력 현장에서의 직무여건 개선노력, 청원경찰과 특수경비원간, 조직 내 상하 간의 대인관계 정립, 실질적인 보수 현실화를 포함한 정책적인 제도의 뒷받침이 절실하다.

  • PDF

상류 오염원 추적을 위한 용존 유기물질 Synchronous 형광스펙트럼 분석 연구 (Analyses of Synchronous Fluorescence Spectra of Dissolved Organic Matter for Tracing Upstream Pollution Sources in Rivers)

  • 허진;김미경;박성원
    • 대한환경공학회지
    • /
    • 제29권3호
    • /
    • pp.317-324
    • /
    • 2007
  • 형광측정법은 자연유기물질을 간편하고 신속하게 분석함으로써 타 분석법에 비해 현장에서 실시간으로 수질관리에 활용할 수 있는 월등한 장점을 가지고 있다. 본 연구에서는 버섯배지용 톱밥 침출수와 생활하수의 영향을 받는 부산지역 수영천 상류 소하천에서 채집한 제한된 수의 대표시료를 대상으로 synchronous 형광스펙트럼을 분석하고 오염원 추적 및 감시 모니터링 가능성 여부에 대한 예비 실험을 실시하였다. 형광스펙트럼 분석에는 오염원 상류 하천, 생활하수 2개 지점, 톱밥 침출수, 하류지점 하천의 5가지 현장 시료를 사용하였다. 사용된 시료 중에서 톱밥 침출수는 다른 시료와 뚜렷한 형광 스펙트럼 차이를 보여 synchronous 형광 스펙트럼 측정을 통해 톱밥 침출수에 의한 오염 추적 및 감시가 가능함을 보여 주었다. Synchronous 형광 스펙트럼에서 적용 가능한 오염원 식별지표(discrimination index)로는 ${\Delta}\lambda=30nm$의 경우 276 nm와 350 nm에서의 형광세기, 275 nm와 285 nm에서의 형광세기 1차 미분 값이 선택되었고, ${\Delta}\lambda=60nm$의 경우 239 nm, 275 nm, 347 nm에서의 형광세기와 315 nm에서의 형광세기 1차 미분 값이 포함되었다. 다양한 혼합비율을 가진 톱밥 침출수와 상류 하천수 혼합 시료를 사용하여 선택된 식별지표의 민감도를 다음의 두 가지 기준을 바탕으로 비교하였다 - (1)실측치와 두 시료 간 혼합 비율에서 예측되는 지표 값과의 차이와 (2)식별 지표와 혼합 비율 사이의 일차 상관관계 정도. 그 결과 276 nm(${\Delta}\lambda=30nm$ 조건)와 347 nm(${\Delta}\lambda=60nm$ 조건)에서의 형광 세기가 현장에서 톱밥 침출수 오염을 식별하는 가장 이상적인 식별지표로 밝혀졌다. 비록 이 연구가 제한된 대표시료와 오염원 종류에 국한되었지만 여기에 사용된 식별지표 평가 과정 및 구체적인 실험방법은 향후 형광측정을 이용한 실시간 오염원 추적 연구에 중요한 기초자료를 제공할 것으로 기대한다.

터널 내부 도상 블록형 흡음재의 고속철도차량 내부 소음에 미치는 영향에 대한 고찰 (Investigation into influence of sound absorption block on interior noise of high speed train in tunnel)

  • 이상헌;정철웅;이송준;김재환;손동기;심규철
    • 한국음향학회지
    • /
    • 제37권4호
    • /
    • pp.223-231
    • /
    • 2018
  • 최근 여러 환경적인 요인으로 인해 기존의 자갈 도상의 터널에서 콘크리트 도상의 터널로 교체가 되고 있지만 콘크리트 도상 터널의 경우 자갈 도상의 터널 보다 소음에 악영향을 미치고 있어 부수적으로 소음에 대한 대책이 필요한 실정이다. 이러한 대책 중 하나로 흡음블록은 설치의 제약이 적고 쉽고 빠르게 설치가 가능하기 때문에 많은 철도에서 시범적으로 적용되고 있다. 하지만 실제 환경과 운영조건에서 흡음블록의 성능에 대한 검증이 필요한 실정이다. 본 논문에서는 터널 내의 흡음블록의 성능을 확인하기 위해 흡음블록의 소음저감효과의 예측뿐만 아니라 호남선의 달성터널의 일부 구간에 흡음블록 설치 전 후의 KTX 실내 소음을 측정하고 그 결과를 비교, 분석하였다. ISO 3381를 준용한 측정장비, 측정방법을 사용하여 고속철도차량 실내소음을 측정하였으며, 터널 내부 운행시간동안에 등가소음도를 계산했다. 또한 흡음블록의 주파수별 흡음특성과 객실내부 장치소음이 영향을 주는 주파수 영역의 영향을 고려하기 위하여 가청주파수 영역 전체에 대한 등가소음도 뿐만 아니라 1/3-octave band를 기초로 주파수 영역대별 영향도도 함께 분석하였다. 또한, 열차의 운행속도와 측정시의 환경조건 등을 고려하여 흡음블록의 실내소음에 대한 영향을 평가하기 위하여 달성터널 전후에 위치한 터널내부 소음 측정값을 사용하여 보정하였다. 측정 결과의 분석을 통하여 흡음블록위에서 주행 할 때 최대 6.8 dB(A) 저감량을 나타내었다. 최종적으로 열차실내소음에 대한 1/3-octave band SPLs(Sound Pressure Levels) 예측값과 실측값을 비교하여 흡음블록에 의한 소음저감 메커니즘에 대한 이해를 증진시켰다.

월성 원자력 발전소 주변 해역의 장기간 수온관측 (Long-Term Observation of Temperature in the Coastal Waters Adjacent to the Wolsung Nuclear Power Plant)

  • 정종률;강현우;신영재;김계영;전호경
    • 한국해양학회지:바다
    • /
    • 제3권4호
    • /
    • pp.183-192
    • /
    • 1998
  • 월성 원자력 발전소 주변해역에 대한 장기간 수온관측을 실시하여, 수온의 장기간 변화양상, 수평 수온분포 및 연직 수온분포 특성을 분석하였다. 관측기간은 1996년 11월 10일부터 1997년 8월 22일까지 약 280 일간이며, 발전소 인근 10 개 정점에 표층 수온관측기를 설치하고 10 분 간격으로 표층수온의 연속관측을 실시하였다. 또한, 수온의 연직구조를 파악하기 위하여 배수구 인근 2 개 정점에 수심별 수온관측기를 계류하여 20 분 간격으로 표층으로부터 수심 10 m까지 1 m 간격으로 수온을 측정하였다. 관측정점들에 대한 월평균수온의 최저치는 2월의 $12.8^{\circ}C$ 였으며, 최고치는 8월의 $19.6^{\circ}C$였다. 6월~8월에는 냉수가 관측해역에 수시로 출현하는 것으로 관측되었다. 표층수온의 일평균 분포에 따르면, 발전소 미가동 시기였던 1996년 11월과 대조적으로, 발전소 가동이 재개된 1996년 12월 이후에는 발전소 배수구를 중심으로 고수온 영역이 항상 존재했다. 매 시간별 수평 수온분포를 분석한 결과, 고온의 해수가 발전소 배수구를 중심으로 반일주기의 남북이동을 하는 것으로 관측되었으며, 매 시간별 연직 수온분포에서도 표층에 반일주기의 고온수가 나타나는 것으로 조사되었다. 스펙트럼 분석결과, 1997년 2~4월의 경우 발전소 배수구에 가까운 정점들에서 반일주기 성분이 우세하게 관측되었으며, 이는 반일주기 조류에 의해 온배수가 이동, 확산된 결과로 해석된다. 1997년 8원에는 발전소 배수구에 가정 가까운 정점 12를 제외한 모든 정점에서 일주기 성분이 우세하게 나타났는데, 이는 온배수에 비해 대양복사에너지가 훨씬 우세하게 작용한 때문으로 사료된다.

  • PDF

PET-CT 검사 시 호흡 동조 시스템들의 유용성 평가 (An Assessment of the Utility of Respiratory Synchronized Systems in the PET/CT Examination)

  • 성용준;윤석환;현준호;이홍재;김진의
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.34-38
    • /
    • 2017
  • PET/CT 검사 시 호흡으로 인한 내부장기의 움직임은 여러 호흡주기 동안 영상화되어 종양크기는 실제보다 증가하고 SUV에도 영향을 미치게 된다. 호흡 동조 시스템들을 이용하여 종양크기와 SUV 변화 유무를 평가해보고자 한다. 장비는 Biograph mCT 64를 사용하였고 호흡 동조 시스템은 RPM과 Anzai 시스템을 사용하였다. 실험을 위해 Point source와 Micro-phantom을 환자는 2016년 8월에서 9월까지 폐 기저부 또는 간 상부에 고형종양이 확인된 환자 12명을 대상으로 호기-호흡상태에서의 PET영상과 호기 후 멈춤 상태의 CT영상을 얻어 기존 Static, RPM, Anzai방식에서의 방사능 농도(kBq/mL), SUVmax, Cylinder diameter(mm), Tumor diameter (mm) 변화 유무를 평가하였다. Point source 방사능 농도 측정 결과 Static 대비 RPM 94%, Anzai 91% 상승하였고 Micro-phantom에서 방사능량을 달리한 2개의 Cylinder에서 SUVmax값은 Static 대비 RPM 61%, 78%, Anzai 58%, 77%로 각각 상승하였고 Cylinder diameter는 RPM -26%, -28%, Anzai -28%, -26% 감소하였다. 환자의 경우 SUVmax값은 Static 대비 RPM은 최소 8.2%에서 최대 94.4%, Anzai는 최소7.6%에서 최대 68.3% 상승하였고 Tumor diameter는 RPM은 최소 -7.6%에서 최대 -28.9%, Anzai는 최소 -9.6%에서 최대 -27.7% 감소하였다. 호흡 동조 시스템 RPM과 Anzai에서 phantom study는 별 차이가 없었지만 환자의 종양에서는 유의미한 차이가 있었다(P<0.05). 호흡 동조 시스템 RPM과 Anzai는 호흡이 일정한 주기로 이루어지는 phantom study에서 별 차이가 없었지만 환자의 경우 일정하지 않은 호흡주기와 시스템간 차이 때문에 유의미한 차이가 발생함을 알 수 있었다. 하지만 호흡 동조 시스템은 기존 Static 대비 종양의 크기는 감소하고 SUV는 증가하여 정확한 진단과 SUV측정에 유용할 것으로 사료된다.

  • PDF

실시간 에어로졸 질량분석기를 이용한 PM1.0의 화학적성분의 특성에 관한 연구 (A Study on the Characteristics of PM1.0 Chemical Components Using a Real-time Aerosol Mass Spectrometer)

  • 박진수;최진수;김현재;오준;성민영;안준영;이상보;김정호
    • 한국도시환경학회지
    • /
    • 제18권4호
    • /
    • pp.485-494
    • /
    • 2018
  • 2017년 겨울철 인천에서 미세먼지($PM_{1.0}$)의 화학적 성분과 산화특성을 파악하였다. 측정기간 대기오염물질 농도는 $PM_{10}$ $46{\pm}22{\mu}g/m^3$, $PM_{2.5}$ $29{\pm}18{\mu}g/m^3$, $SO_2$ 5(${\pm}3$) ppb, CO 0.56(${\pm}0.24$) ppm, $O_3$ 21(${\pm}13$) ppb, $NO_2$ 28(${\pm}17$) ppb이었다. $PM_{1.0}$ 화학적 성분은 organic 성분이 $3.2{\mu}g/m^3$, nitrate $1.9{\mu}g/m^3$로 주요성분으로 나타났다. 주간과 야간에서 대부분 야간에 높은 농도를 나타냈다. 측정기간 NOR(nitrate oxidation rate)은 0.06 이었고, SOR(sulfate oxidation rate)은 0.11이었다. 고농도기간, NOR은 0.6까지 증가하였으며, nitrate 성분도 증가하였다. $NOx/SO_2$ 비는 평균 8.7이었으며, nitrate/sulfate 비율은 평균 2.1로서 측정지점에 위치한 발전소, 산업 보일러를 포함한 고정오염원과 이동오염원인 자동차로부터 배출된 NOx가 기여요인으로 작용한 것으로 판단된다.