• 제목/요약/키워드: reactive filtering

검색결과 19건 처리시간 0.023초

감정적 요소를 고려한 반응학습 추론 시스템 (Reactive Learning Inference System Considering Emotional Factor)

  • 심정연
    • 제어로봇시스템학회논문지
    • /
    • 제10권11호
    • /
    • pp.1107-1111
    • /
    • 2004
  • As an information technology is developed, more intelligent system considering emotional factor for implementing the personality is required. In this paper, Reactive Learning Inference System considering emotional factor is proposed. Emotional Facter(E) is defined for a criterion for representing the personal preference. This system is designed to have functions of Reactive filtering by Emotional factor, Incremental learning, perception & inference and knowledge retrieval. This system is applied to the area for analysis of customer's tastes and its performance is analyzed and compared.

Three-Phase Hybrid Shunt Filters for Power Quality Improvement

  • Bhuvaneswari, G.;G.Nair, Manjula
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.257-264
    • /
    • 2007
  • Active power filters can be cost-effective for use in practical systems with the insertion of a few passive elements in shunt or series configuration. The resulting hybrid filters can be designed to provide dominant lower order harmonic elimination and reactive power support by the passive elements so that the burden on the active filter counterpart is reduced. In this paper, the rate reduction in the shunt active filter is estimated when it is connected in parallel with suitable passive tuned harmonic filters. The active filtering system is based on an appropriate control scheme. The simulation and the experimental results of the shunt active filter, along with the estimated value of reduction in rating, show that the hybrid shunt filtering system is quite effective in compensating for the harmonics and reactive power, in addition to being cost-effective.

순시 무효전력 이론 기반의 능동전력필터 기능을 가지는 삼상 지-소스 정류기 (Three-Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory)

  • 안바르;홍승표;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.365-366
    • /
    • 2015
  • Shunt active power filter is a complete current source which can provide an effective and adjustable solution for elimination of harmonic currents in power system. Its performance depends on strategy employed in reference current generation, control technique and topology of converter used in the design.[1-2]. In this paper Three Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory is described. Thanking to the theory power factor and THD value are significantly improved. Experiment results and conclusions are presented.

  • PDF

Reactive Black Dyes containing Acetoxyethyl sulfone moiety

  • Kim, Tae-Kyung;Oh, Sea-Wha;Shin, Seung-Rim
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2001년도 춘계학술발표회 논문집
    • /
    • pp.62-65
    • /
    • 2001
  • This thesis related to a reactive black dyes containing acetoxyethyl sulfone moiety which is characterized by lessening the loss of dyes in filtering process owing to the low solubility by introducing the aminophenyl- $\beta$ -acetoxyethyl sulfone moiety, saving the cost for waste water treatment by using a small amount of salt in salting-out process and furthermore obtaining bright color with high dyeing yield and substantivity.

  • PDF

디지털 필터링을 이용한 무효전력 제어에 관한 연구 (A Study on a Reactive Power Control using Digital Filtering)

  • 우천희;강신준;이덕규;우광방;이성환
    • 제어로봇시스템학회논문지
    • /
    • 제4권4호
    • /
    • pp.517-524
    • /
    • 1998
  • This paper discusses the development of a reactive power controller using digital signal processing. Digital Signal Processing is the technique of using digital devices to Process continuous signals or data, often in real-time. And DSP algorithms are associated with a discrete time interval between input samples. When one designs a digital filter, one can use a Laplace transform to determine the continuous time frequency response. The corresponding discrete time transform is called Z transform and depends upon discrete samples of the input spaced equally in time. The objectives of this paper are to minimize real power losses and improve the power factor of a given system. Also, the implementation of a direct-form non recursive filter on the TMS320C31 has been described. The application of this microprocessor-based controller using DSP on test system reveals its numerous advantages. Performance and features of the controller for the reactive power control are analyzed.

  • PDF

A Novel Hybrid Active Power Filter with a High-Voltage Rank

  • Li, Yan;Li, Gang
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.719-728
    • /
    • 2013
  • A novel hybrid active power filter (NHAPF) that can be adopted in high-voltage systems is proposed in this paper. The topological structure and filtering principle of the compensating system is provided and analyzed, respectively. Different controlling strategies are also presented to select the suitable strategy for the compensation system. Based on the selected strategy, the harmonic suppression function is used to analyze the influence of system parameters on the compensating system with MATLAB. Moreover, parameters in the injection branch are designed and analyzed. The performance of the proposed NHAPF in harmonic suppression and reactive power compensation is simulated with PSim. Thereafter, the overall control method is proposed. Simulation analysis and real experiments show that the proposed NHAPF exhibits good harmonic suppression and reactive power compensation. The proposed compensated system is based on the three-phase four-switch inverter, which is inexpensive, and the control method is verified for validity and effectiveness.

싸이리스터 컨버터부하에 적용되는 병렬형 능동필터의 적정용량산정 (Capacity Requirement Estimation of Shunt Active Power Filter for Thyristor Converter Load)

  • 박노중;정승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권12호
    • /
    • pp.715-726
    • /
    • 1999
  • This paper estimates the capacity of shunt type active power filters(APF) for harmonic/reactive power compensation with a thyristor converter load. The base capacity requirement of APF is defined for idealized converter load current waveform and the effect of commutation overlap on the APF capacity is examined. The APF capacity required for reactive power compensation in addition to the harmonic elimination is estimated to give maximum achievable power factor for various operating condition of the partially-loaded thyristor converter. The method of current limit of APF is introduced, and it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current while maintaining the filtering performance to meet the level std 519 regulation.

  • PDF

Diagnostic and Active Filtering of Harmonics Generated by Compact Fluorescent Lamps

  • Moulahoum, Samir;Houassine, Hamza;Kabache, Nadir
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.162-168
    • /
    • 2014
  • Use of nonlinear loads, such as power converters, fluorescent lamps and adjustable speed motor drives, is expected to grow rapidly. All of these loads inject harmonic currents. This paper presents the active filtering of the harmonic distortion generated by the compact fluorescent lamps (CFL). The Instantaneous active and reactive power theory (the p-q Theory) is used to design the control of parallel active filter. The control scheme has been verified using Matlab/Simulink with SimPower Systems through a set of simulation tests under different load conditions. Also, the tuning of the active power filter is performed to improve the quality of the electrical power supply.

자가변전설비용 STATCOM의 수전단 역률개선과 고조파 전류 필터링 (Receving-end's power factor improvement and harmonic current filtering useing the private-substion STATCOM)

  • 오영웅;이은웅;임수생;김석곤;이승학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.79-81
    • /
    • 1998
  • STATCOM can compensate industrial load's reactive power and filter the harmonic of nonlinear load's with the rapid dynamic response. In this paper, STATCOM is modelled to synchronous rotating coordinate by circuit dq transformation, and space vector PWM method is applied for broad voltage modulation. Also predict current controller is used for harmonic current filtering.

  • PDF

ESTIMATION OF REQUIRED CAPACITY OF SHUNT TYPE ACTIVE POWER FILTER WITH A THYRISTOR CONVERTER LOAD

  • Jeong, Seung-Gi;Kim, Dong-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.802-807
    • /
    • 1998
  • The main drawback of parallel type active power filters (APF) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement of harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. And it is shown that the APF capacity can be considerably reduced while slightly sacrificing the filtering performance by deliberately limiting the peak current of the APF.

  • PDF