• Title/Summary/Keyword: re-evaluation

Search Result 1,085, Processing Time 0.037 seconds

Evaluation of the Herbal Extract Mixture for the Effects of Hair-Regrowth Compared to 3% Minoxidil; Elongation of Anagen Period on C3H Mice (모발생장기 유도 C3H 생쥐에 있어서 미녹시딜과 생약추출 혼합 조성물의 모발 재성장 유도 효능)

  • 이계호;한선일;박길흥;권영이
    • YAKHAK HOEJI
    • /
    • v.47 no.1
    • /
    • pp.14-19
    • /
    • 2003
  • The hair cycle consists of three phases, growth (anagen), involution (catagen) and quiescence (telogen) phases. In order to evaluate hair re-growth effect of herbal extracts mixture containing the 70% ethanol extracts of Polygoni Multiflori Radix, Mori Cortex Radicis, Gingko Biloba Folium and Pine bud, we have examined the induction of the anagen phase and/or elongation of the anagen period using C3H mice. Morphological examination was done by Hattori' and Ogawa's method. Enzyme activities of ${\gamma}$-glutamyl transpeptidase (${\gamma}$-GT) and alkaline phosphatase (ALP) was detected by Bessey-Lovry-Brock's method. Enzyme activity as a biochemical marker of hair cycle was investigated in the third hair cycle period of C3H mice after depilation. 3% Minoxidil treated group and herbal extract mixture treated group were shown 3 days earlier initiation of anagen than control group. In cycling mouse skin, ${\gamma}$-GT activity is pronounced during anagen and greatly diminished during telogen. Herbal extract mixture has shown promising hair re-growth effect on hair follicular cycles of C3H mice.

The Effect of Cognitive Emotional Control on Life Goals

  • Kim, Jungae
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.79-88
    • /
    • 2021
  • This study was a cross-sectional descriptive investigative study to analyze the effects of sub-factors of cognitive emotional control on life goals. The subjects of the study were 184 people in their 20s, and they were collected online from December 2020 to January 5, 2021 using structured cognitive control capabilities and life goal questionnaires. The collected data were performed using SPSS 18.0 for Frequency, Independent Sample t-test, Pearson correction analysis, Simple regression analysis, and Multiple regression analysis. According to the study, men had both life-oriented and achievement-oriented life goals higher than women. Among the sub-factors of cognitive emotional control (positive focus change, positive reassessment, expansion of view, re-accept plan, acceptance, rumination, self-criticism, others criticism, and destruction) were male and female were higher in self-criticism. Factors affecting life-oriented life goals have been shown to be expanding views, re-accepting plans, and criticizing others, while positive re-evaluation negatively affects achievement-oriented life goals. Based on these results, life-oriented life-goals tend to exhibit adaptive responses to expand views and revise plans and maladaptive responses to blame others, while achievement-oriented life-goals have the ability to positively reassess situations, modify plans and accept negative reactions.

A multi-field CAE analysis for die turning injection application of reservoir fluid tank (리저버 탱크의 Die Turning Injection 적용을 위한 Multi-field CAE 해석)

  • Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.15 no.1
    • /
    • pp.66-71
    • /
    • 2021
  • In this study, die turning injection(DTI) mold design for manufacturing reservoir fluid tanks used for cooling in-vehicle batteries, inverters, and motors was conducted based on multi-field CAE. Part design, performance evaluation, and mold design of the reservoir fluid tank was performed. The frequency response characteristics through modal and harmonic response analysis to satisfy the automotive performance test items for the designed part were examined. Analysis of re-melting characteristics and structural analysis of the driving part for designing the rotating die of the DTI mold were performed. Part design was possible when the natural frequency performance value of 32Hz or higher was satisfied through finite element analysis, and the temperature distribution and deformation characteristics of the part after injection molding were found through the first injection molding analysis. In addition, it can be seen that the temperature change of the primary part greatly influences the re-melting characteristics during the secondary injection. The minimum force for driving the turning die of the designed mold was calculated through structural analysis. Hydraulic system design was possible. Finally, a precise and efficient DTI mold design for the reservoir fluid tank was possible through presented multi-field CAE process.

Design and Implementation of the Customized Contents Organization Engine (맞춤형 콘텐츠 구성 엔진의 설계 및 구현)

  • Heo, Sun-Young;Kim, Eun-Gyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.599-601
    • /
    • 2009
  • In currently being adopted as a e-leaning standard, SCORM it is difficult to provide the customized contents to a learner by changing the learner's level at runtime, and to control selective studying. So, we designed and implemented the customized contents organization engine(CCOE) in order to complement SCORM's faults in this paper. The CCOE consists of a level evaluation module, a contents re-organization module and a question item selection module. A level evaluation module evaluates the learner's level based on a question item reaction theory. And a question item selection module selects some random items by each level or by considering the learner's level which is then provided to a studying before evaluation, a section evaluation, and a quiz. And then this module transmits the selected items to the contents reorganization module for providing the quiz. A contents re-organization module selects the customized contents based on the learner's level by searching the tagged difficulty to the content, and creates the sequence with the selected items and the transmitted items from the question item selection module. If proposed in this paper CCOE is applied, the higher effectiveness of learning is expected by providing the customized learning contents based on the re-evaluated learner's level by each section.

  • PDF

Evaluation of Na2CO3-H2O2 Carbonate Solution Stability (Na2CO3-H2O2 탄산염 용액의 안정성 평가)

  • Lee, Eil-Hee;Lim, Jae-Gwan;Chung, Dong-Yong;Yang, Han-Beum;Kim, Kwang-Wook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.3
    • /
    • pp.131-139
    • /
    • 2011
  • This study was carried out to examine the stability of $Na_2CO_3-H_2O_2$ carbonate solution with aging time in the dissolving solution after oxidative dissolution of U by a carbonate solution, the Cs/Re filtrate after selective precipitation of Cs and Re (as a surrogate for Tc), and the acidification filtrate after precipitation of U by acidification, respectively. The compositions of dissolving solution were not changed with ageing time, and the selective precipitation of Re and Cs was also not affected without regard to the aging time of dissolving solution. The successive removal of Cs and Re from a carbonate dissolving solution was possible. However, the recovery yield of U by acidification was decreased with increasing the aging time of the dissolving solution and the Cs/Re-filtrate, respectively, because U was converted from the uranyl peroxocarbonato complex to the uranyltricarbonate in the solution aged for a long time. Accordingly, it is effective that a dissolving solution and a Cs/Re filtrate are treated within the aging of 7 days, respectively, in order to recover U more than 99%. On the other hand, the recovery of U was carried out in order of the oxidative dissolution of U selective precipitation of Re and Cs precipitation of U by acidification. Almost all of U and a part of FP were co-dissolved in oxidative dissolution step. Over 99% of Re and Cs from the FP co-dissolved with U could be removed by a TPPCl (tetraphenylphosphonium chloride) and a NaTPB (sodium tetraphenylborate), respectively. U was precipitated nearly 100% by acidification to pH 4. Therefore, it was confirmed that the validity of recovery of U by precipitation methods from a SF (spent fuel) in the $Na_2CO_3-H_2O_2$ solution.

An Evaluation of Reinforced Concrete Durability in Chloride Attack Environment under Sustained Load (염해 환경하에서 지속하중을 받는 철근콘크리트 부재의 내구성 평가)

  • Hong, Jun-Seo;Im, Chang-Hun;Yoon, Sang-Chun;Jee, Nam-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1045-1050
    • /
    • 2001
  • This study was performed to evaluate reinforced concrete durability in chloride attack environment under sustained load by the corrosion of reinforcing bars and the permeation of chloride ion. Generally, it is regarded that permeability of chloride ion is determined by the properties of concrete, but the effects of load which make alternation of concrete inner structure such as crack and so on should not neglected. In this study, it is shown that the relation between bending load on RC beam, deflection and crack of specimen, permeation of chloride ion, rating of re-bar corrosion, and the relation between compression load and permeation of chloride ion. Therefore the effects of load on permeation of chloride ion and re-bar corrosion are evaluated.

  • PDF

A Study on the Evaluation of Reliability of the Vacuum Circuit Breaker for the Electrical Fire (전기화재에 따른 진공차단기의 건전성 평가)

  • Choi, Hong-Kyoo;Park, Joon-Yeol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.24-28
    • /
    • 2013
  • Fire-hited electrical equipment has possibility of deterioration. So its replacement is essential in terms of safety. However, the economic burden is increased. Therefore, the replacement or re-use of it is to be determined by tests. But the research of Integrity Assessment on Fire-hited electrical equipments is very rare. In this paper, we tested to determine the replacement or re-use of Fire-hited vacuum circuit breaker. And provided the data for the integrity assessment through the analysis of its deterioration.

Distribution and morphological characteristics of Scopolia japonica Maxim. in Korea

  • Jang, Chang Gee;Park, Myung Soon;Nam, Bo Mi;Pak, Hubert H.;Eom, Jeong Ae;Chung, Gyu Young
    • Korean Journal of Plant Taxonomy
    • /
    • v.41 no.3
    • /
    • pp.271-279
    • /
    • 2011
  • The morphological characteristics of the Korean Scopolia japonica Maxim., commonly known as 'Mi-chi-gwang-i-pul' in Korean, were re-evaluated in comparison with results from previous research, while the distribution map was formulated according to existing flora and voucher specimens. The result of the re-evaluation has shown that there are some distinctive discrepancies compared to the previous reports of some characteristics such as the color of the basal stem, numbers of lateral veins, apex shape of calyx and corolla including the color of corolla. The Korean Scopolia japonica Maxim is found throughout Korea except Jeju-do province. The intra-specific species such as S. parviflora (Dunn.) Nakai, S. lutescens Y.N. Lee and S. kwangdokensis Y.N. Lee were treated as synonyms of S. japonica Maxim. in this research.

The performance evaluation of Stirling cryocooler for thermal imaging system (IV) : Vibration, Noise, Leak test (열상장비용 스터링 극저온 냉동기 특성평가 (IV) : 진동, 소음, 누설시험)

  • 박성제;홍용주;김효봉;김양훈;최상규;나종문
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.167-170
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the vibration, acoustic noise, EMI and leak rate are evaluated. Vibration outputs are measured to 20KHz for compressor and expander, respectively. And, the objective of noise test is a noise level, less than 30㏈ at 5 m. EMI tests are carried out according to the standard MIL-STD-461C tests RE01 and RE02. Leak test for the Stilting cryocooler is performed by bombing method.

  • PDF

Re-Demagnetization Operation Characteristics Analysis of a Variable Flux Memory Motor Using Coupled Preisach Modeling and FEM (프라이자흐 모델과 유한요소법을 이용한 가변자속형 메모리 모터의 재자화, 감자 특성 해석)

  • Kim Gi-Bok;Kwon Sun-Bum;Lee Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.905-907
    • /
    • 2004
  • This paper deals with the PM performance evaluations in a variable flux memory motor (VFMM) using a coupled finite element method (FEM) and Preisach modeling, which is presented to analyze the magnetic characteristics of permanent magnets. The focus of this paper is the operation characteristics evaluation relative to magnetizing direction and quantity of permanent magnets on re-, demagnetization condition in a variable flux memory motor(VFMM)

  • PDF