• Title/Summary/Keyword: ray

Search Result 20,576, Processing Time 0.04 seconds

원적외선 방출 특성을 갖는 나노 웹의 제조 및 원적외선 방사 특성에 관한 연구 (Fabrication of Ceramic Particles Deposited Nano-web using Electrospinning Process and Its Far-infrared Ray Emission Property)

  • 홍소야;이창환;김주용
    • 한국염색가공학회지
    • /
    • 제22권2호
    • /
    • pp.118-122
    • /
    • 2010
  • The interest in textile which has far-infrared ray emissive property has been increased in the field of biophysics and medicine. In this study, far-infrared ray emissive polyurethane nano-web was obtained using electrospinning of polyurethane(PU) solution mixed with ceramics powder and far-infrared ray emissive properties of nano-web were evaluated by measuring far-infrared ray emission power and emissivity(%). To investigate the influence of concentration of ceramics powder in PU solution and temperature for far-infrared ray emissive properties, far-infrared ray emissivity was measured at varied temperature using various nano-web including varied concentration of ceramics powder. Polyurethane nano-web was characterized by SEM to observe the deposition of ceramics powder on polyurethane nano-web surface. The far-infrared ray emissivity was increased with the concentration of ceramics powder in the nano-web. The far-infrared ray emission power was enhanced with increasing temperature of the samples; however, far-infrared ray emissivity was decreased with increasing temperature because the increase of emission power of ceramic containing nano-web was lower than the emission power of black body one.

Nutritional Compositions of Ray and Effects of Steaming on Antioxidative Activities of Ray Hydrolysates

  • Jung, Eun-Young;Kim, Seong-Yeong;Bae, Song-Hwan;Chang, Un-Jae;Park, Sung-Sun;Lee, Sam-Pin;Suh, Hyung-Joo
    • Food Science and Biotechnology
    • /
    • 제18권4호
    • /
    • pp.917-922
    • /
    • 2009
  • This study investigated the effects of steaming on the antioxidative activities of ray hydrolysates in vitro. Based on the results of 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay, steamed ray hydrolysate possessed significantly higher antioxidative activities than raw ray hydrolysates (p<0.05). The 2,2-azino-bis-(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) radical scavenging activity of steamed ray hydrolysate by pancreatin was slightly lower than raw ray hydrolysate at all concentrations. Raw ray hydrolysate displayed moderate hydroxyl radical scavenging activity, while steamed ray hydrolysate showed a greater increase in hydroxyl radical scavenging activity than raw ray hydrolysate at concentrations above 21.33 mg/mL, and it reached 58.21% at 42.67 mg/mL. The results of this study show that ray hydrolysates have potent free radical scavenging activities and reducing power, and the steaming has a partial impact on the antioxidative activity of ray hydrolysates.

An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

  • Kim, Hyun Jin;Kim, Hyun Nam;Raza, Hamid Saeed;Park, Han Beom;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.799-804
    • /
    • 2016
  • A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

Barge의 천골 기저부 X-ray에 대한 연구 (Study about sacral base X-ray of Barge)

  • 민영광
    • 척추신경추나의학회지
    • /
    • 제6권1호
    • /
    • pp.19-26
    • /
    • 2011
  • Objectives : The purpose of this study is to research the necessity of sacral base X-ray that Barge insisted. Methods : I have done a comparative analysis in side of short leg and side of sacral inferior with sacral base X-ray and pelvis A-P Xray pictures of 42 patients with lower back pain from December 1, 2010 to March 31, 2011. Results : Even though most of the subjects in study were male, 36 people had plateau of sacral base and 29 people had symmetry in sacral base X-ray. There was no statistical significance in the side of short leg and side of sacral base inferior in Sacral base X-ray, but there was a statistical significance in pelvis A-P x-ray. 22 people had same side of short leg and side of sacral base inferior in sacral base X-ray and pelvis A-P X-ray and 14 people didn't. 29 people had same side of sacral base inferior in sacral base X-ray and pelvis A-P X-ray and 13 people didn't. Conclusions : According to the result of the study, sacral base X-ray is necessary for correct sacral base inferior analysis.

  • PDF

X선촬영시(線撮影時) 연부조직(軟部組織) 두께에 따른 선량분포(線量分布)에 관(關)한 연구(硏究) (A Study on the Distribution of X-ray according to the Thickness of Soft Tissue in Radiography)

  • 박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제11권2호
    • /
    • pp.3-15
    • /
    • 1988
  • When X-rays were projected into a patient, there occured the phenomena such as penetration, absorption and scattering etc. The penetrating rays were recorded on films as X-ray image used for diagnosis but scattered rays caused the radiation hazard both to the patient, specialist and technicians. The soft tissue includes many organs which are sensitive to the radiation and in may occupy $40{\sim}50%$ of body weight. Therefore X-rays should be carefully projected to the patient and it is strongly recommended to analyse the distribution of X-rays, when ever the patient is exposed to X-rays. In this study, the distribution of X-ray according to the thickness, the radiation field and the tube voltages (kVp) in soft tissue, the following results were obtained: 1. Total transmitted rays which kept the step with X-ray tube voltage (kVp) increased in proportion to the increasing of X-ray tube voltage. 2. The scattered ray rate in the total transmitted ray was not significantly found with X-ray tube voltage. 3. The affecting factors of the scattered ray rate in total transmitted ray were shown through the radiation field and the thickness. 4. The dose of scattered ray by the angle was observed more in direction of primary ray ($0^{\circ}$) and back scattering ($160^{\circ}$) than in direction of $90^{\circ}$. 5. The more the distance from phantom to the patient should be less distribution of scattered ray.

  • PDF

차량 내 통신을 위한 FlexRay 시스템 구현 (Implementation of FlexRay Systems for Vehicle Appliacations)

  • 전창하;이재경;장인걸;정진균
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.182-184
    • /
    • 2009
  • FlexRay는 차세대 차량 및 선박 내 전자 장치간의 통신을 위해 고속의 시리얼 통신, time triggered bus, fault tolerant 통신을 제공하는 새로운 네트워크 통신 시스템의 표준이다. FlexRay Communication Controller(CC)는 FlexRay 프로토콜 규격의 핵심 부분이다. 본 논문에서는 먼저 SDL(Specification and Description Language)를 이용하여 FlexRay CC 프로토콜 규격과 기능 부분을 설계한다. 다음 설계한 SDL 소스를 기반으로 Verilog HDL을 이용하여 하드웨어로 설계한다. 설계한 FlexRay CC는 Samsung $0.35{\mu}m$ 공정을 이용하여 합성하였으며, 그 결과 80 MHz의 속도로 동작하는 것으로 나타났다. 또한 FlexRay 시스템의 동작을 확인하기 위해 로봇에 적용되는 음원위치 추정 시스템에 응용하였다. 응용 시스템은 ALTERA Excalibur ARM EPAX4F672C3을 이용하여 검증하였으며 성공적으로 동작함을 확인하였다.

  • PDF

디지털 x-ray 영상시스템을 위한 무선 트리거 발생기 (Wireless Triggering Pulse Generation for Digital X-ray Imaging System)

  • 고대식;이재철;이주신
    • 한국항행학회논문지
    • /
    • 제11권2호
    • /
    • pp.163-169
    • /
    • 2007
  • 본 논문에서는 x-ray 영상시스템의 영상을 획득하기 위하여 x-ray 발생기와 영상획득시스템 사이의 동기를 맞추어 주는 트리거 발생기를 연구분석 하였다. 무선 트리거 발생기는 디지털영상 획득시스템으로부터 영상획득의 시작을 지시할 수 있는 ACQ_START 신호와 영상획득의 끝을 알리는 ACC_END 신호를 발생시킬 수 있도록 설계하였다. 디지털 영상의 획득은 ACQ_START 신호와 ACQ_END 신호 사이의 시간동안에만 정확하게 이루어지며 무선 원격 x-ray 신호의 검출을 통하여 유선통신 프로토콜 없이 정확한 x-ray 영상의 획득이 가능하고 20 mAs 의 x-ray 레벨에서 3.5 line pair /mm 분해능을 나타냄을 확인하였다.

  • PDF

FlexRay 프로토콜 설계 및 로봇 시스템 응용 (Implementation of FlexRay Communication Controller Protocol and its Application to a Robot System)

  • 강현수;허일남;김용은;정진균
    • 대한전자공학회논문지TC
    • /
    • 제45권6호
    • /
    • pp.1-7
    • /
    • 2008
  • FlexRay는 차세대 차량 내 전자 장치간의 통신을 위해 고속의 시리얼 통신, time triggered bus, fault tolerant 통신을 제공하는 새로운 네트워크 통신 시스템의 표준이다. FlexRay Communication Controller(CC)는 FlexRay 프로토콜 규격의 핵심 부분이다. 본 논문에서는 먼저 SDL(Specification and Description Language)를 이용하여 FlexRay CC 프로토콜 규격과 기능 부분을 설계한다. 다음 설계한 SDL 소스를 기반으로 Verilog HDL을 이용하여 하드웨어로 설계한다. 설계한 FlexRay CC는 Samsung $0.35\;{\mu}m$ 공정을 이용하여 합성하였으며, 그 결과 80 MHz의 속도로 동작하는 것으로 나타났다. 또한 FlexRay 시스템의 동작을 확인하기 위해 로봇에 적용되는 음원위치 추정 시스템에 응용하였다. 응용 시스템은 ALTERA Excalibur ARM EPAX4F672C3을 이용하여 검증하였으며 성공적으로 동작함을 확인하였다.

FlexRay 프로토콜 설계 및 자동차 경보 시스템 응용 (Implementation of FlexRay Protocol Specification and its Application to a Automobile Advance Alarm System)

  • 허일남;양상훈;정진균
    • 대한전자공학회논문지TC
    • /
    • 제45권8호
    • /
    • pp.98-105
    • /
    • 2008
  • FlexRay는 높은 유연성과 신뢰성을 갖는 고속의 통신프로토콜이다. 자동차회사와 반도체회사들에 의해 개발되었고 x-by-wire 시스템을 이용하여 차량 내 LAN으로 구현된다. FlexRay는 차량 내 전자 장치간의 통신을 위해 고속의 시리얼 통신, time triggered bus, fault tolerant 통신을 제공한다. 본 논문에서는 먼저 SDL(Specification and Description Language)을 이용하여 FlexRay communication controller와 bus guardian 프로토콜 규격과 기능 부분을 설계한다. 다음 설계한 SDL 소스를 기반으로 Verilog HDL을 이용하여 하드웨어로 설계한다. 설계한 FlexRay 시스템은 Samsung $0.35{\mu}m$ 공정을 이용하여 합성하였으며, 그 결과 76 MHz의 속도로 동작하는 것으로 나타났다. 또한 FlexRay 시스템의 동작을 확인하기 위해 차량에 적용되는 자동차 경보 시스템에 응용하였다. FlexRay 시스템은 ALTERA Excalibur ARM EPAX4F672C3을 이용하여 검증하였으며 성공적으로 동작함을 확인하였다.

Silicon P-N Junction Diode에 대한 X-Ray 및 Gamma-Ray 의 Dose Ratec 측정 (Measurements of X-Ray and Gamma Ray Dosse Rate by the Silicon P-N Junction Diode)

  • 정만영;김덕진
    • 전기의세계
    • /
    • 제13권3호
    • /
    • pp.13-20
    • /
    • 1964
  • The measurements of X-ray and Gamma-ray Dose Rate have been successfully made by measuring the short circuit current of the Silicon P-N Junction Diode being irradiated. The short circuit current flows when a silicon P-N Junction Diode is irradiated by X-ray of Gammaray radiations due to photovoltaic effect. A brief analysis is given in order to verify the proportionality of a short circuit current to the Dose Rate. Using this method, measurements of X-ray Dose Rate were carried out in the range of 0.05-1600 r/m successfully. The calibration was made by comparing with Victoreen condenser r-meter. Some advantages in this Dose Rate meter over a condenser r-meter were found. One can measure a continous variation of X-ray Dose Rate with this rate meter at the control console of X-ray device.

  • PDF