• Title/Summary/Keyword: rate mode

검색결과 2,347건 처리시간 0.032초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

고에너지 방사선치료 시 치료변수에 따른 광중성자 선량 변화 연구 (Experimental investigation of the photoneutron production out of the high-energy photon fields at linear accelerator)

  • 김연수;윤인하;배선명;강태영;백금문;김성환;남욱원;이재진;박영식
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.257-264
    • /
    • 2014
  • 목 적 : 고에너지 광자선을 이용한 방사선치료 시 발생되는 광중성자는 치료대상인 종양 주위의 인접한 정상조직에서 2차적인 암의 발생에 기인 될 수 있다고 알려져 있다. 본 연구에서는 방사선치료계획 시에 고려할 수 있는 변수 중 치료방법, 선속평탄여과판, 선량률, 갠트리 각도들을 변환시켰을 때 발생된 광중성자의 선량 변화를 비교 분석하였다. 대상 및 방법 : 실험에는 TrueBeam $ST{\time}TM$(Ver.1.5, Varian, USA)치료기를 사용하였다. 광중성자 측정 장비는 조직등가비례계수기(Tissue Equivalent Proportional Counter : TEPC)인 KTEPC를 이용하였으며, 치료대의 세로 방향으로 조사야 중앙 하단 6cm 지점에서 측정을 실시하였다. 치료방법, 선속평탄여과판의 사용유무, 선량율에 따른 광중성자 선량의 차이를 평가하기 위하여 모든 환자에 대하여 전산화치료계획시스템(Eclipse Ver 10.0, Varian, USA)으로 방사선치료계획을 각각 수립하였다. 치료방법으로는 세기변조방사선치료와 용적변조회전방사선치료로 구분하였으며, 선량율은 400MU/min, 1,200MU/min 및 2,400MU/min에 따른 차이를 평가하였다. 또한 방사선의 입사방향에 따른 광중성자 선량을 측정하였다. 결 과 : 치료방법의 차이에 따라 세기변조방사선치료와 용적변조회전방사선치료로 조사하였을 때 산란 광중성자 평균선량은 각각 $449.7{\mu}Sv$, $2940.7{\mu}Sv$로 측정되었다. 선속평탄여과판의 사용 유무에 따라 Flattening Filter(FF)모드와 Flattening Filter Free(FFF)모드에서의 산란 광중성자 평균선량은 $2940.7{\mu}Sv$, $232.0{\mu}Sv$로 측정되었다. 400, 1200, 2400 MU/min으로 선량률을 변환시켜 조사하였을 때 CASE I은 $3242.5{\mu}Sv$, $3189.4{\mu}Sv$, $3191.2{\mu}Sv$로, CASE II는 $3493.2{\mu}Sv$, $3482.6{\mu}Sv$, $3477.2{\mu}Sv$로, 그리고 CASE III에서 $4592.2{\mu}Sv$, $4580.0{\mu}Sv$, $4542.3{\mu}Sv$로 측정 되었다. $0^{\circ}$부터 $315^{\circ}$까지 $45^{\circ}$간격으로 갠트리 각도를 변환시켰을 때 산란 광중성자 선량은 10MV 광자선에 대하여 최소 $3.2{\mu}Sv$, 최대 $14.7{\mu}Sv$이었으며, 갠트리 각도가 $180^{\circ}$일 때 가장 높게 나타났다. 15MV 광자선의 경우 최소 $369.6{\mu}Sv$ 최대 $448.0{\mu}Sv$이었으며, 역시 갠트리 각도가 $180^{\circ}$일 때 가장 높게 측정되었다. 결 론 : 치료방법의 차이에 따른 실험은 용적변조회전방사선치료가 세기변조방사선치료 보다 산란된 광중성자 선량이 측정점에서 평균 6.5배 높게 측정되었다. 선속평탄여과판의 사용 차이에 따른 실험에서 선속평탄여과판을 사용하였을 때 12.7배 높게 측정되었다. 선량률을 변환에 따른 차이는 큰 차이를 보이지 않았다. 갠트리 각도에 따른 산란 광중성자 선량 측정에서는 광자선이 치료대를 지나는 각도인 $135^{\circ}$, $180^{\circ}$, $225^{\circ}$에서 산란 광중성자 선량이 증가하는 것을 확인할 수 있었다. TrueBeam $ST{\time}TM$을 이용한 FFF 모드와 세기변조방사선치료를 한 경우 산란 광중성자가 적게 발생한다는 것을 확인할 수 있었다. 지속적으로 더 많은 변수에 대한 실험을 계획하고 광중성자 측정에 대한 평가를 통하여, 보다 환자들에게 안전한 방사선치료에 기여할 수 있을 것으로 사료된다.

도입주체에 따른 인터넷경로의 도입효과 (The Impact of the Internet Channel Introduction Depending on the Ownership of the Internet Channel)

  • 유원상
    • 마케팅과학연구
    • /
    • 제19권1호
    • /
    • pp.37-46
    • /
    • 2009
  • The Census Bureau of the Department of Commerce announced in May 2008 that U.S. retail e-commerce sales for 2006 reached $ 107 billion, up from $ 87 billion in 2005 - an increase of 22 percent. From 2001 to 2006, retail e-sales increased at an average annual growth rate of 25.4 percent. The explosive growth of E-Commerce has caused profound changes in marketing channel relationships and structures in many industries. Despite the great potential implications for both academicians and practitioners, there still exists a great deal of uncertainty about the impact of the Internet channel introduction on distribution channel management. The purpose of this study is to investigate how the ownership of the new Internet channel affects the existing channel members and consumers. To explore the above research questions, this study conducts well-controlled mathematical experiments to isolate the impact of the Internet channel by comparing before and after the Internet channel entry. The model consists of a monopolist manufacturer selling its product through a channel system including one independent physical store before the entry of an Internet store. The addition of the Internet store to this channel system results in a mixed channel comprised of two different types of channels. The new Internet store can be launched by the independent physical store such as Bestbuy. In this case, the physical retailer coordinates the two types of stores to maximize the joint profits from the two stores. The Internet store also can be introduced by an independent Internet retailer such as Amazon. In this case, a retail level competition occurs between the two types of stores. Although the manufacturer sells only one product, consumers view each product-outlet pair as a unique offering. Thus, the introduction of the Internet channel provides two product offerings for consumers. The channel structures analyzed in this study are illustrated in Fig.1. It is assumed that the manufacturer plays as a Stackelberg leader maximizing its own profits with the foresight of the independent retailer's optimal responses as typically assumed in previous analytical channel studies. As a Stackelberg follower, the independent physical retailer or independent Internet retailer maximizes its own profits, conditional on the manufacturer's wholesale price. The price competition between two the independent retailers is assumed to be a Bertrand Nash game. For simplicity, the marginal cost is set at zero, as typically assumed in this type of study. In order to explore the research questions above, this study develops a game theoretic model that possesses the following three key characteristics. First, the model explicitly captures the fact that an Internet channel and a physical store exist in two independent dimensions (one in physical space and the other in cyber space). This enables this model to demonstrate that the effect of adding an Internet store is different from that of adding another physical store. Second, the model reflects the fact that consumers are heterogeneous in their preferences for using a physical store and for using an Internet channel. Third, the model captures the vertical strategic interactions between an upstream manufacturer and a downstream retailer, making it possible to analyze the channel structure issues discussed in this paper. Although numerous previous models capture this vertical dimension of marketing channels, none simultaneously incorporates the three characteristics reflected in this model. The analysis results are summarized in Table 1. When the new Internet channel is introduced by the existing physical retailer and the retailer coordinates both types of stores to maximize the joint profits from the both stores, retail prices increase due to a combination of the coordination of the retail prices and the wider market coverage. The quantity sold does not significantly increase despite the wider market coverage, because the excessively high retail prices alleviate the market coverage effect to a degree. Interestingly, the coordinated total retail profits are lower than the combined retail profits of two competing independent retailers. This implies that when a physical retailer opens an Internet channel, the retailers could be better off managing the two channels separately rather than coordinating them, unless they have the foresight of the manufacturer's pricing behavior. It is also found that the introduction of an Internet channel affects the power balance of the channel. The retail competition is strong when an independent Internet store joins a channel with an independent physical retailer. This implies that each retailer in this structure has weak channel power. Due to intense retail competition, the manufacturer uses its channel power to increase its wholesale price to extract more profits from the total channel profit. However, the retailers cannot increase retail prices accordingly because of the intense retail level competition, leading to lower channel power. In this case, consumer welfare increases due to the wider market coverage and lower retail prices caused by the retail competition. The model employed for this study is not designed to capture all the characteristics of the Internet channel. The theoretical model in this study can also be applied for any stores that are not geographically constrained such as TV home shopping or catalog sales via mail. The reasons the model in this study is names as "Internet" are as follows: first, the most representative example of the stores that are not geographically constrained is the Internet. Second, catalog sales usually determine the target markets using the pre-specified mailing lists. In this aspect, the model used in this study is closer to the Internet than catalog sales. However, it would be a desirable future research direction to mathematically and theoretically distinguish the core differences among the stores that are not geographically constrained. The model is simplified by a set of assumptions to obtain mathematical traceability. First, this study assumes the price is the only strategic tool for competition. In the real world, however, various marketing variables can be used for competition. Therefore, a more realistic model can be designed if a model incorporates other various marketing variables such as service levels or operation costs. Second, this study assumes the market with one monopoly manufacturer. Therefore, the results from this study should be carefully interpreted considering this limitation. Future research could extend this limitation by introducing manufacturer level competition. Finally, some of the results are drawn from the assumption that the monopoly manufacturer is the Stackelberg leader. Although this is a standard assumption among game theoretic studies of this kind, we could gain deeper understanding and generalize our findings beyond this assumption if the model is analyzed by different game rules.

  • PDF

압력조절환기법에서 압력상승시간(Pressure Rise Time)이 흡기 일환기량 및 가스교환에 미치는 영향 (Effect of Pressure Rise Time on Tidal Volume and Gas Exchange During Pressure Control Ventilation)

  • 정병오;고윤석;심태선;이상도;김우성;김동순;김원동;임채만
    • Tuberculosis and Respiratory Diseases
    • /
    • 제48권5호
    • /
    • pp.766-772
    • /
    • 2000
  • 배경 : 압력조절환기법(pressure control ventilation mode, PCV)에서 설정된 기도압의 달성은 기도저항이 일정한 조건에서 초기 흡기 유량 (inspiratory flow)에 의해 결정되며 압력상승시간(pressure rise time) 조절은 이 흡기 유량을 변동시킨다. 압력조절환기법에서 흡기 일환기량은 흡기 시간과 흡기 시간내 평균 흡기 유량에 따라 결정되므로 압력 도달 시간을 짧게 하면 초기 유량이 많아지게 되고 따라서 흡기되는 용적이 증가할 것으로 예상된다. 본 연구는 압력조절환기 법에서 압력상승시간을 줄이는 것이 흡기 일환기량 및 가스교환을 호전시키는지 알아보고자 하였다. 방법 : 호흡부전으로 기계호흡 중인 환자 13명(58$\pm$16세, 남 : 여=7 : 6)에서 Servo 300 (Simens-Elema, Solna, Sweden) 상의 압력상승시간 10%. 5% 및 30분 간 씩 적용하고 동맥혈 검사, 혈역동학적 지표(혈압, 분당맥박수) 및 호흡 지표(일회 호흡량, 최대 흡기유량, 최대 흡기압, 평균 기도압, 기도저항, 탄성도, 호기말 이산화탄소, 동맥혈가스)를 측정하였다. 결과 : 1) 압력상승시간이 10%, 5%, 0%로 변경시 일회 호흡량은 425$\pm$94 ml, 439$\pm$101 ml, 456$\pm$106ml로 증가되었다(p<0.001). 압력상승시간 단축에 따라 평균기도압 역시 증가되었다(각각 11.2$\pm$3.7cm $H_2O$, 12.0$\pm$3.7 cm $H_2O$, 12.5$\pm$3.8 cm $H_2O$; p<0.001). 2) pH는 10% 와 5% 보다 0%에서 높았으며(각각 7.40$\pm$0.08, 7.40$\pm$0.92, 7.41$\pm$0.96 ; p<0.0), $PaCO_2$도 10%와 5%에서 보다 0%에서 낮았다(각각 47.4$\pm$15.8 mm Hg, 47.2$\pm$15.7 mm Hg, 44.6$\pm$16.2 mm Hg ; p<0.01). 결론 : 압력조절환기법에서 압력상승시간의 단축은 일환기량과 평균기도압을 증가시키고, 동맥혈이산화탄소분압 저하 및 이에 따른 pH 상승 효과가 있었다. 압력조절 환기법에서 압력상승시간은 일환기량을 조절할 수 있는 한 변수로 사료된다.

  • PDF

급성폐손상과 급성호흡곤란증후군 환자에서 압력조절환기법을 이용한 폐포모집술의 효과와 안정성 (The Effect and Safety of Alveolar Recruitment Maneuver using Pressure-Controlled Ventilation in Acute Lung Injury and Acute Respiratory Distress Syndrome)

  • 정경수;박병훈;신상윤;전한호;박선철;강신명;박무석;한창훈;김정주;이선민;김세규;장준;김성규;김영삼
    • Tuberculosis and Respiratory Diseases
    • /
    • 제63권5호
    • /
    • pp.423-429
    • /
    • 2007
  • 연구배경: 급성폐손상과 급성호흡곤란증후군 대상자에서 폐포모집술의 적절한 방법에 대해서는 정해진 것이 없다. 이 연구를 통해 폐포모집술들 중 압력조절환기법을 이용한 폐포모집술의 효과와 안정성을 확인하고자 하였다. 방 법: 급성폐손상 및 급성호흡곤란증후군에 해당하는 대상자들을 대상으로 압력조절환기 방식에서 $30cmH_2O$의 흡입압력과 $20cmH_2O$의 호기말양압으로 2분 동안 폐포모집술을 시행하였다. 동맥혈 산소분압, 정맥혈 산소포화도, 혈압과 맥박, 중심정맥압, 폐탄성, 호기말양압, 흉부 X-ray를 시술 전 후로 확인하였다. 결 과: 16명의 대상자들 중에서, 3명은 폐외 급성폐손상 및 급성호흡곤란증후군 대상자였고 나머지 13명은 폐내 급성폐손상 및 급성호흡곤란증후군 대상자였다. 평균 나이는 $61.0{\pm}11.8$세였고, 평균 APACHE II score는 $21.6{\pm}11.9$이었으며, SAPS score는 $44.6{\pm}14$이었다. 폐포모집술 시행 전, 평균 호기말양압은 $11.3{\pm}1.5mmHg$이었으며 평균 동맥혈산소분압/흡입산소분율은 $130.3{\pm}60.2$이었다. 폐포모집술 시행 20분 후, 동맥혈산소분압/흡입산소분율의 비를 측정하여 50% 이상 상승한 경우를 반응군으로 50% 이하로 상승하거나 감소한 경우를 비반응군으로 분류하였다. 8명의 대상자들은 반응군이었고 8명의 대상자들은 비반응군이었다. 두 군간의 인구학적인 특성과 기계호흡의 패턴, APACHE II score, SAPS score, 동맥혈산소분압/흡입산소분율과 혈역동학적 특성 사이에는 차이가 없었다. 폐포모집술 이후, 동맥혈산소분압/흡입산소분율의 비는 상승하였다(p<0.001). 그 최대치는 폐포모집술 이후 60분에서 관찰되었다. 동맥혈 이산화탄소분압은 상승하는 경향을 보였다(p=0.05). 폐포모집술 전 후의 평균동맥압의 차이는 없었다(p=0.08). 기흉 등의 압력 손상에 의한 합병증은 없었으며, 단 한 예에서만 혈압 저하로 인해 폐포모집술을 중단하였으나 수액 공급 후 바로 회복되었다. 결 론: 본 연구를 통해서, 압력조절환기를 이용한 폐포모집술은 급성폐손상 및 급성호흡곤란증후군 대상자에서 산소화의 개선을 보였다. 또한 혈역학적 부작용은 거의 없었으며 고압력에 의한 합병증은 없었다. 따라서 압력조절환기를 이용한 폐포모집술은 폐보호전략과 더불어 임상적인 유용성과 안전성이 있을 것으로 기대된다.

토끼의 정상 폐 모델에서 부분액체환기 시 가스교환에 영향을 주는 인자들에 대한 연구 (Evaluation of Parameters of Gas Exchange During Partial Liquid Ventilation in Normal Rabbit Lung)

  • 안창혁;고영민;박정웅;서지영;고원중;임성용;김철홍;안영미;정만표;김호중;권오정
    • Tuberculosis and Respiratory Diseases
    • /
    • 제52권1호
    • /
    • pp.14-23
    • /
    • 2002
  • 배 경 : 부분액체환기 (partial liquid ventilation; PLV) 시 최적의 기계환기의 설정에 대해서는 아직 논란이 많은 상태이다. 이에 정상 폐의 PLV 시 가스교환에 영향을 주는 인자들을 관찰함으로써, PLV 시 최적의 기계환기 설정을 확립하는 데에 이용하고자 본 연구를 시행하였다. 방 법 : New Zealand 산 백색 토끼 7 마리를 기계환기를 시행하였다. 기계환기는 압력 조절 양식으로 일회호흡량 ($V_T$) 8 mL/kg, PEEP 4 $cmH_2O$, 흡기대호기비 (I: E ratio) 1:2, 흡입산소분율 ($F_IO_2$) 0.75로 설정하였고, 호흡수(RR)는 $PaCO_2$가 35~45 mmHg 사이에 유지되도록 조절하였다. 이후 30분마다 기계환기기의 설정을 protocol에 따라 변화시키면서 가스환기(gas ventilation; GV)를 시행하였는데 ; (1) 기저 설정 단계, (2) 역비환기 (inverse I: E ratio) 단계로 I:E ratio 2:1, (3) 고 PEEP 단계로 2단계와 같은 평균흡기압 (MIP)을 유지하는 정도의 PEEP 증가, (4) 고 $V_T$ 단계로 $V_T$ 15 mL/kg, (5) 고RR 단계로 4단계와 같은 분당환기량 (MV)을 유지하는 정도로 RR을 증가시켰다. 그 후 perfluorodecalin 18 mL/kg 주입 후 상기 protocol과 동일하게 PLV를 하였다. 각각에서 동맥혈가스검사와 폐역학 및 혈역학적 지표를 측정하였다. 결 과 : (1) GV 시 $PaO_2$는 다섯 단계를 거치는 동안 의미 있는 변화를 보이지 않았다. $PaCO_2$는 고 $V_T$단계와 고 RR 단계에서 의미 있게 감소하였다(p<0.05). GV 시 폐역학 및 혈역학적 지표의 의미 있는 변화는 보이지 않았다. (2) PLV 군의 기저 $PaO_2$$312{\pm}113$ mmHg로 GV군의 $504{\pm}81$ mmHg 에 비해 의미 있게 낮았다(p=0.001). PLV 시 역비환기 단계나 고 RR 단계에서는 기저설정 단계와 비교하여 $PaO_2$의 의미 있는 차이가 관찰되지 않았으나, 고 PEEP 단계 ($452{\pm}38$ mmHg)와 고 $V_T$($461{\pm}53$ mmHg) 단계에서는 기저설정 단계보다 유의한 상승이 관찰되었다. (3) $PaCO_2$는 GV군과 PLV군 모두에서 고 $V_T$ 단계와 고 RR 단계에서 기저설정 단계보다 의미 있게 낮았다. PLV군의 기저설정 단계와 고 RR 단계의 $PaCO_2$는 GV 군보다 의미 있게 증가하였다(p<0.05). (4) PLV 시 폐역학 및 혈역학적 지표의 의미 있는 변화는 보이지 않았다 결 론 : 정상 폐에서 PLV 시 최적의 가스교환을 위해서는 적절한 PEEP과 $V_T$이 중용할 것으로 사료된다.

목련(Magnolia kobus DC.)에서 분리한 흰비단병균(Sclerotium rolfsii Sacc.)에 관한 연구 (Studies on Sclerotium rolfsii Sacc. isolated from Magnolia kobus DC. in Korea)

  • 김기청
    • 한국응용곤충학회지
    • /
    • 제13권3호
    • /
    • pp.105-133
    • /
    • 1974
  • 본 연구는 목련에서 분리한 흰비단병균 Sclerotimu rolfsii Sacc.의 분화형을 밝히고 균계생장 및 균핵형성에 대한 영양생리를 구명코저 vitamin, 질소원, 탄소원의 효과를 검토했으며 또 본 균과 Penicillium sp.와의 생태적 관계를 해명하기 위한 기초적인 연구로서 본 균의 균계생장 및 균핵형성에 대한 Penicillium 배양여액의 촉진효과와 그 요인을 밝히려고 시도하였다. 본 연구결과를 종합해서 적요하면 다음과 같다. 1. 목연에서 분리한 흰비단병균 제1형, 축2형은 배지상의 성상이나 생리적 성질 펄 병원성이 상이하였다. 특히 목연 아카시아에 대한 병원성은 양자 동일하나 콩이나 오이에 대해서는 제2형균이 제1형균보다 더 강하였다. 2. 공시된 14종의 질소원중 $KNO_2$와 glycine을 제외하고는 모두 thiamine hydrochloride 10r/l가 첨가되었을 때 비로소 공시균의 균계생장 및 균핵형성에 이용되었다. 질소의 형태별로 보면 균계생장에 있어서는 $NO_3-N$보다는 $NH_4-N$이 훨씬 더 효과적이며 organic N은 화합물에 따라 상이하였다. 그러나 균핵형성에 있어서는 이와 반대로 $NO_3-N$이 효과적이었다. $NO_2-N$은 균계생장이나, 균핵형성에 전혀 효과가 없었다. 3. 공시 탄소원 7종도 대체적으로 thiamine이 존재하지 않는 한 균계생장이나 균핵형성에 아무런 효과가 없었다. thiamine이 첨가될 경우 균계생장에 있어서 glucose와 saccharose가 가장 효과적이고 maltose와 soluble starch는 효과가 적었으며 xylose, lactose, glyceline은 전혀 효과가 없었다. 균핵형성에 있어서는 loctose를 제외하고는 전구에서 균핵형성을 보였으며 모두 비슷한 효과를 나타냈다. 4. 배지중의 질소원이 동일수준이면 탄소원이 증가함에 따라 균계생장량이 증가하였다. 그러나 질소원의 량에는 한도가 있는 것으로 질소 0.5g/l이상에서는 오히려 균계생장이 억제되었다. 그러나 균핵형성에 있어서는 탄소원의 증가에 따라 균핵형성량이 저하하였다. 5. 공시균은 thiamine 결핍균으로서 균계생장 최적 thiamine 농도는 20r/l이고 이 농도를 초과하면 오히려 균계생장이 억제되는데 150r/l에서는 무첨가구와 거의 같은 정도로 억제되었다. 6. 공시균의 생장에 있어서 thiamine의 첨가에 따른 질소원리용도는 $NH_4NO_3>(NH_4)_2SO_4>asparagine>KNO_3$의 순위이며 질소원별 thiamine 최적요구량은 $KNO_3$인 경우 12r/l, asparagine인 경우 16r/l 정도였다. 균핵형성량에 있어서는 $KNO_3>NH_4NO_3>asparagine>(NH_4)_2SO_4$의 순위로서 thiamine 최적량은 $KNO_3,\;NH_4NO_3$인 경우 8r/l에서 전균핵생산량의 대부분이 형성되나 asparagine인 경우에는 16r/l 정도였다. 7. 배양액의 pH는 공시균이 생장을 개시하자마자 3.5정도로 급격히 떨어지나 그 이후부터는 생장량이 증가함에 따라 완만하게 떨어졌다. 그러나 pH2.2 이하로는 더 내려가지 않았다. 8. 공시균의 균계생장에 대한 각종 vitamin의 상호효과는 thiamine, biotin, pyridoxine, inositol의 4가지 조합에 있어서도 thiamine이 첨가되지 않은 곳에서는 거의 효과가 나타나지 않았다. 그러나 thiamine+pyridoxine, thiamine+inosital, thiamine+biotin+pyridoxine, thiamine+pyridoxine+inositol구에 있어서는 thiamine 단독 첨가구와 동등 혹은 그 이상의 효과를 나타내지만 thiamine+biotin과 thiamine+biotin+inosital구는 오히려 떨어졌다. 균핵형성에 있어서는 thiamine 단독구에 비하여 각구 모두 약간씩 증가하였다. 9. Penicillium 배양여액중에는 공시균의 균계생장을 촉진하는 물질이 존재하며 배양여액 6-15ml/50ml 배양액의 농도에서 거의 최고균계생장량에 달하였다. 10. 질소원으로서 첨가한 $NH_4NO_3$ 혹은 asparagine은 균계생장에 있어서 배양여액농도 여가에 관계없이 $NH_4NO_3$가 더 유효하였다. 11. 배양여액에 대한 일련의 처리에 있어서 휘발성물질분획, 비휘발성물질분획, 휘발산분획, ether 가용성유기산분획, ether 불용성물질분획, cation 흡착물질분획, cation 비흡착물질분획, anion 흡착물질분획 및 비흡착물질분획의 9분획중 비휘발성물질분획, ether 불용물질분획, cation 흡착물질분획 및 anion 비흡착물질분획에서만 균계가 잘 자랐다. 그러나 균핵은 오직 cation 흡착물질분획에서만 형성되었다. 12. 이 결과는 배양여액중에 균계생장물질, 균핵형성물질 및 균핵형성억제물질이 존재하며 이들 물질은 각각 별개의 물질로서 전2자는 비휘발성이고 ether 불용성이며 cation교환수지에는 흡착되지 않는 물질이며 후자는 비휘발성이고 ether 불용성이며 cation 및 anion 교환수지에 흡착되지 않는 물질임을 암시한다. 13. DNP-aminoacids paper chromatography에 의하여 cation 교환수지흡착분획중에서 aspartic acid, cystine, glycine, histidine, lycine, tyrosine 및 dinitroaniline 7종의 아미노산이 검출되었다. 14. S. rolfsii의 균계생장 및 균핵형성은 glutamic acid, aspartic acid, cystine, histidine 및 glycine의 단독첨가나 혼합첨가에 의해서 촉진되지 않았고 다만 tyrosine에 의해서 약간 촉진되었다. 15. 균핵의 습열에 대한 저항성은 균핵의 수분함유량에 따라 다르며 수분함유량이 적은 것이 보다 더 강하였다. 배지에서 채취한 균핵은 제1,2형균 모두 $52^{\circ}C$에서 5분에 사멸하거나 155일간 $26{\circ}C$에서 건조시킨 것은 $52^{\circ}C$에 있어서 제1형균은 15분, 제2형균은 10분, $57^{\circ}C$에 있어서는 제1형균은 5분, 제2형균은 10분처리에 사멸하였다. 16. 배양균핵을 132일간 $26^{\circ}C$에서 건조시킨 것은 제1,2형균 모두 전부 발아하였고 기건상태에서 283일간 방치한 천연균핵도 제1,2균형 모두 발아하였으며 443일간처리한 것도 아직 제1형균 $20\%$, 제2형균 $16$의 발아율을 보지하고 있었다. 17. 저온에 대한 저항성은 균계, 균계괴, 균핵의 순으로 강하였는데 균계는 $-7--8^{\circ}C$ 1주간 처리에서 완전 사멸하였으나 균계괴는 $-17--20^{\circ}C$ 3주에서도 아직 사멸치 않은 것이 있었으며 균핵은 $-17--20^{\circ}C$ 3주에서 대부분 생존하였다. 18. 약제저항력은 승괴수 $0.05%$에 있어서 제1형균은 180분 제2형균은 240분, $0.1\%$에 있어서는 제1형균 60분, 제2형균 30분에 각각 사멸하였고, Uspulun 800배에 있어서는 제1형균은 120분에 사멸하나 제2형균은 180분에도 사멸치 않으며 500배에 있어서는 제1,2형균 모두 90분에 비로소 사멸하였다. 그러나 유산동 $5\%$ 240분, Ceresan 석탄, Mercuron 각 500배 80분처리에도 아무런 영향이 없었다. 19. Benlate와 Tachigaren의 농도가 증가함에 따라 균계생장 억제효과도 증가하였다. 처리 6째에는 Benlate 0.5ppm을 제외하고는 전농도에서 뚜렷한 억제효과를 나타내었으나 12일째에는 농도에 따라 현저한 차이를 나타냈다. Benlate 0.5ppm 처리는 대조구에 비하여 $66\%$, 2.0ppm은 $92\%$의 억제효과를, Tachigaren은 1ppm $54\%$, 1.5ppm과 2.0ppm은 $77\%$의 억제효과를 나타냈다. 양자 모두 500ppm에서는 거의 완전히 균계생장을 억제시켰다. 균핵형성은 Benlate 500ppm과 Tachigaren 500ppm 및 1000ppm에서 $100\%$ 억제되었다. 20. 일반적으로 균계생장량이 증가함에 따라 배지중의 glucose나 $NH_4-N$의 소비량도 증가하였으나 Benlate나 Techigaren을 처리할 경우 그 농도의 증가에 따라 이들의 소비량이 억제되었다. 그러나 Benlate 저농도(0.5ppm 및 1ppm)에 있어서는 $NH_4-N$의 소비가 무처리구보다 많았다. 21. glucose와 $NH_4-N$의 흡수이용효과 즉 glucose나 $NH_4-N$ 1mg을 소비하여 생산된 균계량은 Benlate나 Techigaren의 처리로 말미암아 크게 저하되었다. 그 정도는 농도에 관계없이 처리 3일째에 가장 심했고 이후 시일이 경과함에 따라 높아졌다. Benlate 처리의 glucose를 제외하고는 대체로 농도가 증가함에 따라 흡수이용효과가 저하되었다. 22. 토양배양에 있어서 $CO_2$ 배출량으로 측정한 균계생장은 어느 농도에서나 저지되지 않았고 다만 Tachigaren 100mg/g 토양에서만 현저하게 억제되었다. 균핵형성은 Benlate나 Tachigaren 10mg/g 토양에서 완전히 억제되었다. 23. Benlate와 Tachigaren 0.1, 1.0, 10, 100, 1000ppm에 10분 및 20분간 침지처리한 결과 균핵의 발아억제효과를 인정할 수 없었다.

  • PDF