• Title/Summary/Keyword: rapid imaging

Search Result 332, Processing Time 0.023 seconds

PDA Transmission of Medical Images by CDMA (CDMA에 의한 의료영상의 PDA전송)

  • Lee, Myong-Ho;Lim, Jae-Dong;Ahn, Bung-Ju;Lee, Hwun-Jae;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.2
    • /
    • pp.13-22
    • /
    • 2007
  • The purpose of this study was to survey a development of the wireless transmission system of medical images for ubiquitous medicine. There have been many changes in medical equipments and medical record medical treatment and medical record within hospital and PACS(Picture Archiving Communication System) which is picture management system for patients can be typical cases. It is difficult to use these automated medical systems unless they are within hospital and in case of rapid image reading in the emergency cases or in absence of doctor, it is difficult to perform it immediately. The present study implemented an image transmission system using CDMA connection so that images in the server can be viewed at any time and in any place. Remote wireless diagnosis based on medical images using PDA is applicable to medical areas that require mobility, and the use of PDA can be an ideal alternative for point of care. The use of PDA enables prompt and accurate access to digital medical images, which in turn reduces medical accidents and improves the quality of medical services through high productivity and efficiency of medical practitioners' works. It also enables quick response to patients' demands and high-quality medical services and, consequently, patients' high satisfaction.

  • PDF

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.

Manikin Model Study on Reproducibility and Accuracy of Maxillofacial Measurements Determined by Stereocamera: Comparative Study of Direct Anthropometry, Digitizer and Stereophotogrammetery (스테레오 카메라를 이용한 안면부 측정의 재현성과 정확도에 대한 마네킨을 이용한 연구: 직접 인체계측, Digitizer, Stereophotogrammetry의 비교 연구)

  • Jeoung, Youn-Wook;Yang, Ji-Woong;Chung, Kwang;Kook, Min-Suk;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose: Recently, a three dimensional approach to hard and soft tissues of the maxillofacial area has been widely used. This study was to evaluate the reproducibility and accuracy of a stereocamera compared to actual measurement methods using a digital caliper and digitizer. Methods: The stereoscopies of 7 head dummies with different sizes and shapes were obtained using a Di3D system (Dimensional Imaging, Glasgow, UK) after marking reference points on facial areas. From the obtained stereoscopy, 10 measurements representing the width, height and depth of each of the facial sections of the dummy were measured twice using a three dimensional reverse engineering software program (RapidForm$^{TM}$ 2006, Inus, Seoul, Korea). The x, y, and z coordinates of each of the three dimensional measurements were obtained and distances between two points were calculated. All procedures were repeated twice. The actual measurement method was performed twice, directly on dummies, using a digital caliper and values were compared with the previously determined values. Results: The results were as follows. In the ANOVA analysis, there were no significant statistical differences among the three measurement methods. In the Bonferroni analysis, with adjustments applied for multiple comparisons, there was no difference between actual measurement methods using a digitizer and a digital caliper. However, there was some difference between using a stereocamera and actual measurement methods using a digitizer and a digital caliper in values of $Ex_{Rt}-Ex_{Lt}$, $En_{Rt}-En_{Lt}$, $Ala_{Rt}-Ala_{Lt}$, $Ch_{Rt}-Ch_{Lt}$, G-Pg', $Ala_{Rt}$-Prn, $Ala_{Rt}$-Prn. The mean value for technical error in measurement (TEM) in Di3D (0.98 mm) was slightly higher than for a digital caliper (0.17 mm) and a digitizer (0.30 mm). In an intraclass correlation coefficient (ICC) there were no significant differences among the three measurement methods, but the Di3D system with the stereocamera showed relatively lower reproducibility compared to actual measurement methods using a digitizer and a digital caliper. Conclusion: These results indicate that some complementary measures may be needed to improve accuracy and reproducibility in the Di3D system with stereocamera.

In vivo comparison of Lu-177-labeled phosphonate compounds as potential agents for bone pain palliation in rodents

  • Chang, Young Soo;Lee, Yun-Sang;Kim, Young Ju;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • Lutetium-177 ($T_{1/2}=6.71day$) is an adequate radionuclide for therapy, which has both beta emission ($E_{max}=497keV$) for therapeutic effect and gamma emission (113 and 208 keV) for imaging. $^{177}Lu$ labeled ethylenediamine-N,N,N',N'-tetrakis (methylene phosphonic acid) (EDTMP) and 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraaminomethylenephosphonate (DOTMP) have been proposed as radiopharmaceuticals for bone pain palliation. In this study, we compared radiochemistry and biodistribution of $^{177}Lu$-EDTMP and $^{177}Lu$-DOTMP. EDTMP and DOTMP were synthesized, and 1 mg of each was labeled with $^{177}Lu$ at pH 7~8 with high efficiency (>98%). For comparative biodistribution studies, $^{177}Lu$-EDTMP or $^{177}Lu$-DOTMP were injected into ICR-mice through tail vein, and then biodistribution data were obtained as percentages of injected dose per gram of tissue (% ID/g). Urine excretions of both agents in mice were checked for 7 days. Rat images were also obtained after injection of $^{177}Lu$-EDTMP or $^{177}Lu$-DOTMP. $^{177}Lu$-DOTMP (100% at 1 min) showed faster labeling than $^{177}Lu$-EDTMP (100% at 30 min). Both of them were stable at least for 21 days at room temperature. High bone uptakes were found for both $^{177}Lu$-EDTMP and $^{177}Lu$-DOTMP: 38.0 and 34.1% ID/g at 3 hr, respectively; and 33.2 and 18.8% ID/g at 7 day, respectively. Rapid excretions to urine were found for both agents ($^{177}Lu$-EDTMP: 56%, $^{177}Lu$-DOTMP: 63% at 1 day). Other organs showed very low uptakes. Rat images of both $^{177}Lu$-EDTMP and $^{177}Lu$-DOTMP showed high bone uptakes and low soft tissue uptakes. In conclusion, both $^{177}Lu$-EDTMP and $^{177}Lu$-DOTMP showed high potential as bone pain palliation agents. $^{177}Lu$-EDTMP showed higher bone uptake and slower bone clearance in mice than those of $^{177}Lu$-DOTMP.

A Study of Signal Intensity of MRA in Flow Phantom of Fusiform Aneurysm (방추형 동맥류 모형에서 자기공명 혈관조영술의 신호강도에 대한 연구)

  • 한기석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.83-88
    • /
    • 1998
  • Purpose : Authors correlated the three-dimensional time-of-flight MRA signal intensity characteristics and flow profile simulated by computer in an experimental flow phantom model. Materials and Methods : The three-dimensional time-of-flight MRA was performed in a fusiform flow phantom and analyzed the flow signal. computer assisted flow simulation was performed in same flow geometry. The MRA signal intensity and flow velocity distribution and direction was compared. Results : The flow was depicted as homogeneous signal internsity in inlet and outlet area and inhomogeneous signal intensity in fusiform area. Typically, the flow was depicted as target appearance in transition area to outlet. Whereas mean signal internsity decreased slowly in fusiform area, it rapidly dropped and resumed in transition area to outlet. In computer assisted flow simulation, Whereas there were flow velocity decrease and flow direction change to peripheral in entrance to fusiform area, ther were rapid flow velocity resuming and flow direction change to central in transition area to outlet. Conclusion : The signal loss and target appearance in transition area to outlet is characteristic of fusiform flow. These signal changes correlate with abrupt flow velocity and direction change well.

  • PDF

Ultrasonographic and radiographic study on experimental cystitis in rabbit (실험적 방광염 유발 토끼에서의 초음파 및 방사선학적 연구)

  • Sung, Jai-ki;Chang, Dong-woo;Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.4
    • /
    • pp.973-990
    • /
    • 1996
  • To investigate diagnostic imaging of cystitis and to apply it to the small animal practice, ultrasonogram of urinary bladder with moderate distension(4ml/kg) and with complete distension(9ml/kg) to evaluate the irregularity and thickness of bladder, radiography and histopathological examination were performed after experimental cystitis induction. On double contrast cystography, mucosal membrane of the urinary bladder was smooth and thickening urinary bladder wall was not found before cystitis induction. At 3rd day post induction(PI), mucosal irregularity was noted at the cranioventral region of the urinary bladder. Thickening of the urinary bladder wall and filling defect was observed as well. Cystographic findings of 7, 10, 15, 21 day PI were similar to that of 3rd day PI. On ultrasonographic findings of the mural thickness in induction group, it was ascertain that the mural thickness with moderate distention was more thickened than with complete distention at transverse scan. Ultrasonographic findings at longitudinal scan were similar to those of transverse scan. On ultrasonographic findings of mucosal irregularity in induction group, from PI to 7 day PI, mucosal irregularity with moderate distention was more irregular than mucosal irregularity with complete distention. At 10 day PI, there was similarity between moderate distention and complete distention. On histopathologic examination of a section of urinary bladder taken 3 day PI, the mucosal and submucosa were infiltrated by a mixture of thick inflammatory exudate which was composed of neutrophil, plasma protein, bacterial colony and necrotic cells. Congestion, hemorrhage and edema were also observed in the submucosa. At 7th day PI, the mucosal change was similar to that of 3rd day PI, but neovascularization and fibroplasia were observed in the submucosa. At 15th and 21th day PI, mild hyperplasia of mucosal epithelium was observed in the mucosa. Deposition of collagen, neovascularization and severe diffuse infiltration of lymphocyte were observed. These results suggest that ultrasonographic examination with moderate distention is considered to be a more simple, rapid, noninvasive, sensitive and useful diagnostic method than other diagnostic methods for the diagnosis of the cystitis and the differential diagnosis of urinary tract infection.

  • PDF

Minimally Invasive Anterior Decompression Technique without Instrumented Fusion for Huge Ossification of the Posterior Longitudinal Ligament in the Thoracic Spine : Technical Note And Literature Review

  • Yu, Jae Won;Yun, Sang-O;Hsieh, Chang-Sheng;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.597-603
    • /
    • 2017
  • Objective : Several surgical methods have been reported for treatment of ossification of the posterior longitudinal ligament (OPLL) in the thoracic spine. Despite rapid innovation of instruments and techniques for spinal surgery, the postoperative outcomes are not always favorable. This article reports a minimally invasive anterior decompression technique without instrumented fusion, which was modified from the conventional procedure. The authors present 2 cases of huge beak-type OPLL. Patients underwent minimally invasive anterior decompression without fusion. This method created a space on the ventral side of the OPLL without violating global thoracic spinal stability. Via this space, the OPLL and anterior lateral side of the dural sac can be seen and manipulated directly. Then, total removal of the OPLL was accomplished. No orthosis was needed. In this article, we share our key technique and concepts for treatment of huge thoracic OPLL. Methods : Case 1. 51-year-old female was referred to our hospital with right lower limb radiating pain and paresis. Thoracic OPLL at T6-7 had been identified at our hospital, and conservative treatment had been tried without success. Case 2. This 54-year-old female with a 6-month history of progressive gait disturbance and bilateral lower extremity radiating pain (right>left) was admitted to our institute. She also had hypoesthesia in both lower legs. Her symptoms had been gradually progressing. Computed tomography scans showed massive OPLL at the T9-10 level. Magnetic resonance imaging of the thoracolumbar spine demonstrated ventral bony masses with severe anterior compression of the spinal cord at the same level. Results : We used this surgical method in 2 patients with a huge beaked-type OPLL in the thoracic level. Complete removal of the OPLL via anterior decompression without instrumented fusion was accomplished. The 1st case had no intraoperative or postoperative complications, and the 2nd case had 1 intraoperative complication (dural tear) and no postoperative complications. There were no residual symptoms of the lower extremities. Conclusion : This surgical technique allows the surgeon to safely and effectively perform minimally invasive anterior decompression without instrumented fusion via a transthoracic approach for thoracic OPLL. It can be applied at the mid and lower level of the thoracic spine and could become a standard procedure for treatment of huge beak-type thoracic OPLL.

National Disaster Scientific Investigation and Disaster Monitoring using Remote Sensing and Geo-information (원격탐사와 공간정보를 활용한 국가 재난원인 과학조사 및 재난 모니터링)

  • Kim, Seongsam;Kim, Jinyoung;Kim, Jinsoo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.5_2
    • /
    • pp.763-772
    • /
    • 2019
  • High-resolution satellites capable of observing the Earth periodically enhance applicability of remote sensing in the field of national disaster management from national disaster pre-monitoring to rapid recovery planning. The National Disaster Management Research Institute (NDMI) has been developed various satellite-based disaster management technologies and applied to disaster site operations related to typhoons and storms, droughts, heavy snowfall, ground displacement, heat wave, and heavy rainfall. Although the limitation of timely imaging of satellite is a challenging issue in emergent disaster situation, it can be solved through international cooperation to cope with global disasters led by domestic and international space development agencies and disaster organizations. This article of special issue deals with the scientific disaster management technologies using remote sensing and advanced equipments of NDMI in order to detect and monitor national disasters occurred by global abnormal climate change around the Korean Peninsula: satellite-based disaster monitoring technologies which can detect and monitor disaster in early stage and advanced investigation equipments which can collect high-quality geo-information data at disaster site.

Seismic Weathering Correction Using IRS Approach: A Test to the Synthetic Data of Cheongju Granitic Bodies (IRS(간섭 굴절보정)를 이용한 탄성파 풍화대 보정: 청주 화강암체에 대한 적용)

  • Kang, Yu-Gyeong;Sa, Jin-Hyeon;Kim, Ji-Soo;Kim, Jong-Woo
    • The Journal of Engineering Geology
    • /
    • v.29 no.2
    • /
    • pp.153-162
    • /
    • 2019
  • Rapid variations in the geometry (i.e., thickness) of the refractor and low velocities affect greatly the imaging of the reflectors of land seismic data. Conventional solutions to obtain the weathering models utilizes first break picking method, which requires time consuming steps and causes the human error in picking the first arrivals. A new interferometric approach (interferometric refraction statics, IRS) which utilizes the first arrival signal (S/N enhanced by refraction convolution stack) instead of first break picking, is tested in this study to the synthetic data from the velocity structure provided by surface geophysics (refraction, MASW) and borehole geophysics (tomography, SPS logging) for the Cheongju granitic bodies. The results of IRS approach are found to be better than the ones from conventional first break picking in terms of continuities and horizontal resolution of the reflectors. The unresolved long-wavelength statics in brute stack are much removed by IRS weathering correction and the overlying refractors (the base of shallow weathering zone) are incidentally delineated in the refraction convolution stack.

A Study of brain Atlases in Hippocampus Volume Measurement Using IBASPM (IBASPM을 이용한 해마체적 측정에서 뇌 Atlases에 대한 고찰)

  • Kim, Ju-ho;Lee, Ju-won;Kim, Seong-hu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.981-984
    • /
    • 2014
  • Volumetric measurement of hippocampus using IBASPM, the 20's normal adults 10 people's brain images were acquired in order to assess the changes according to the type of the Atlas. Images was obtained using MPRAGE of a 3-D gradient echo pulse sequence on Head matrix coil of 1.5T MRI system. The results of Paired t-test using obtained volume of hippocampus depending on the type of the Atlas, Atlas69-Altas84, Atlas69-Atlas116(p=0.729, 0.729) in the left hippocampus and Atlas69-Atlas84, Atlas69-Atlas116(p=0.219, 0.219) in right hippocampal formation were no significant differences but in the area except this, there was significant difference(p=0.000). The volume of the hippocampus using Atlas84 and Atlas116, represented the same value and there was no significant difference. In the image analysis using the overlay of atlas image and original image, Atlas71 could be found that the area of hippocampus did mismatch. In the case of atlas used in this study, because it has been developed by the westerners, there are differences between brain of asian. It would be needed to development of new Atlas for high accuracy measurement of the volume of hippocampus.

  • PDF