• Title/Summary/Keyword: rapid imaging

Search Result 329, Processing Time 0.029 seconds

Advances in Damage Visualization Algorithm of Ultrasonic Propagation Imaging System

  • Lee, Jung-Ryul;Sunuwar, Nitam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.232-240
    • /
    • 2013
  • This paper presents recent advances in damage visualization algorithms of laser generated ultrasonic propagation imaging(UPI) system. An effective damage evaluation method is required to extract correct information from raw data to properly characterize anomalies present in structure. A temporal-reference free imaging system provides easy and rapid defect inspection capability with less computational complexity. In this paper a number of methods such as ultrasonic wave propagation imaging(UWPI), anomalous wave propagation imaging(AWPI), ultrasonic spectral imaging(USI), wavelet ultrasonic propagation imaging(WUPI), variable time window amplitude mapping(VTWAM), time point adjustment(TPA), time of flight and amplitude mapping(ToF&Amp) and ultrasonic wavenumber imaging(UWI) are discussed with instances of successful implementation on various structures.

A study on the implementation of Imaging System for Magnetic Resonance Imaging (자기공명전단을 위한 영상화 시스템 구현에 관한 연구)

  • Jin, S.O.;Won, J.I.;Park, Y.H.;Huh, Y.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.597-599
    • /
    • 1998
  • The clinical acceptance of magnetic resonance imaging(MRI) system has been more rapid than that of the other medical image diagnosis system(X-ray, CT, etc) with the advantage of nonhazardous nature, high resolution capability, potential for chemically specified imaging. MRI system is composed of super conducting magnet, gradient fields, rf transceiver, system controller and imaging software technology. In this paper, introducing the principle of magnetic resonance imaging, it proposes the implementation of PC-based MRI system.

  • PDF

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

Imaging Cancer Metabolism

  • Momcilovic, Milica;Shackelford, David B.
    • Biomolecules & Therapeutics
    • /
    • v.26 no.1
    • /
    • pp.81-92
    • /
    • 2018
  • It is widely accepted that altered metabolism contributes to cancer growth and has been described as a hallmark of cancer. Our view and understanding of cancer metabolism has expanded at a rapid pace, however, there remains a need to study metabolic dependencies of human cancer in vivo. Recent studies have sought to utilize multi-modality imaging (MMI) techniques in order to build a more detailed and comprehensive understanding of cancer metabolism. MMI combines several in vivo techniques that can provide complementary information related to cancer metabolism. We describe several non-invasive imaging techniques that provide both anatomical and functional information related to tumor metabolism. These imaging modalities include: positron emission tomography (PET), computed tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS) that uses hyperpolarized probes and optical imaging utilizing bioluminescence and quantification of light emitted. We describe how these imaging modalities can be combined with mass spectrometry and quantitative immunochemistry to obtain more complete picture of cancer metabolism. In vivo studies of tumor metabolism are emerging in the field and represent an important component to our understanding of how metabolism shapes and defines cancer initiation, progression and response to treatment. In this review we describe in vivo based studies of cancer metabolism that have taken advantage of MMI in both pre-clinical and clinical studies. MMI promises to advance our understanding of cancer metabolism in both basic research and clinical settings with the ultimate goal of improving detection, diagnosis and treatment of cancer patients.

Effect of input current patterns on dynamic electrical impedance imaging of two-phase flows (이상유동의 동적 전기 임피던스 가시화에 대한 전류패턴의 영향)

  • Chung, Soon-Il;ljaz, U.Z.;Khambampati, A.K.;Kim, Sin;Kim, Kyung-Youn;Kim, Min-Chan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.475-478
    • /
    • 2006
  • In electrical impedance tomography (EIT) an array of electrodes is attached on the boundary of an object and small alternating currents are injected through these electrodes, and then the resulting voltages are measured. An estimation for the cross-sectional resistivity distribution in the object is obtained by using these current and voltage data in a nondestructive manner. In this paper, the electrical impedance imaging of two-phase flows undergoing rapid transient is considered with a special emphasis on the effect of the current pattern on the image reconstruction. The trigonometric current pattern, which is commonly used in the conventional static electrical impedance imaging, shows poor performance in case of the dynamic imaging considered in this work. Extensive numerical experiments are conducted with various kinds of current patterns and their effects on the image reconstruction performance are examined.

  • PDF

A Performance Evaluation of a Heat Dissipation Design for a Lithium-Ion Energy Storage System Using Infrared Thermal Imaging (적외선 열화상을 활용한 리튬 이온 ESS의 방열설계 성능평가에 관한 연구)

  • Kim, Eun-Ji;Lee, Gyung-Il;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.5
    • /
    • pp.105-110
    • /
    • 2020
  • The global battery market is rapidly growing due to the development of vehicles(EV) and wireless electronic products. In particular logistics robots, which hielp to produce EVs, have attracted much interest in research in Korea Because logistics sites and factories operate continuously for 24 hours, the technology that can dramatically increase the operation time of the logistics equipment is rapidly developing, and various high-level technologies are required for the batteries used in. for example, logistics robots. These required technologies include those that enable rapid battery charging as well wireless charging to charge batteries while moving. The development of these technologies, however, result in increasing explosions and topical accidents involving rapid charging batteries These accidents due to the thermal shock caused by the heat generated during the charging of the battery cell. In this study, a performance evaluation of a heat dissipation design using infrared thermal imaging was performed on an energy storage systrm(Ess) applied with an internal heat conduction cooling method using a heating plate.

Imaging Findings in Pediatric Musculoskeletal Infection and Inflammation (소아 근골격계 감염성 질환 및 염증성 질환의 영상 소견)

  • Ji Young Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.520-530
    • /
    • 2024
  • Infections and inflammatory conditions of immature musculoskeletal systems in pediatric patients also affect the adjacent muscles, connective tissues, and joints. Rapid diagnosis leading to appropriate treatment can significantly impact the occurrence of complications and mortality rates due to these conditions. When a radiologist becomes familiar with the imaging findings of pediatric musculoskeletal infections and inflammatory diseases, rapid differential diagnoses and more timely and appropirate treatment could be possible. In this paper, we introduce the imaging findings of infectious and inflammatory diseases affecting the immature musculoskeletal system, such as osteomyelitis, pyogenic arthritis, juvenile idiopathic arthritis, and hemophilic arthritis, based on the anatomical and pathophysiological characteristics of the immature musculoskeletal system in children.

High-speed Two-photon Laser Scanning Microscopy Imaging of in vivo Blood Cells in Rapid Circulation at Velocities of Up to 1.2 Millimeters per Second

  • Boutilier, Richard M.;Park, Jae Sung;Lee, Ho
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.595-605
    • /
    • 2018
  • The two-photon process of microscopy provides good spatial resolution and optical sectioning ability when observing quasi-static endogenous fluorescent tissue within an in vivo animal model skin. In order to extend the use of such systems, we developed a two-photon laser scanning microscopy system capable of also capturing $512{\times}512$ pixel images at 90 frames per second. This was made possible by incorporating a 72 facet polygon mirror which was mounted on a 55 kRPM motor to enhance the fast-scan axis speed in the horizontal direction. Using the enhanced temporal resolution of our high-speed two-photon laser scanning microscope, we show that rapid processes, such as fluorescently labeled erythrocytes moving in mouse blood flow at up to 1.2 mm/s, can be achieved.