• 제목/요약/키워드: ramp system

검색결과 244건 처리시간 0.021초

초고압 전력케이블 절연체의 Flow Pattern에 따른 절연성능 고찰 (Dielectric Strength According to Flow Pattern in EHV Power Cable Insulation)

  • 이승엽;김영호;이상진;김동욱;최명규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1539-1541
    • /
    • 2000
  • Insulation layers in XLPE power cables may have some patterns generated in the manufacturing process. They are called 'flow patterns' and show flow history of molten polyethylene between inner and outer semiconducting layers. Flow patterns are even seen with naked human eyes and suspected to be inhomogeniety of insulation, weakening insulation performance. Investigated in this paper is electrical treeing resistance and ac breakdown strength according to flow patterns. Experiments of electrical treeing and ac breakdown strength by means of ramp tests were conducted using newly developed electrode system with point-to-plane structure and sphere-to-sphere structure, respectively. All results were analyzed with the application of statistics, showing little differences.

  • PDF

VSI-IM 구동 시스템에 벡터제어를 이용한 전류제어 PWM 방식의 제어특성 (Control Characteristics of Current Controlled PWM Using Vector Control in VSI-IM Drive System)

  • Dong Hwa Chung
    • 전자공학회논문지B
    • /
    • 제28B권12호
    • /
    • pp.38-50
    • /
    • 1991
  • A current-controlled scheme of pulse width modulation voltage source inverter (PWM VSI) has attracted considerable attention due to its fast response with current limit and especially suitable for potentially high performance applications such as AC motor drives and UPS systems. These features yield near-sinusoidal currents in the load with reduced current peaks, lower inverter switching frequency and reduce inverter and load stresses. A high performance current-controlled inverter must have a quick response in transient state and low harmonic current in steady state. This paper compares and shows the controlled-characteristics with hysteresis controller(HC), ramp comparison controller(RCC) and predictive controller(PC) of PWM inverter to control actual current of VSI-IM.

  • PDF

인공위성용 전원을 위한 평균전류형 제어 BOOST 컨버터에 관한 연구 (A Study of Average Current Mode Control Boost Converter for Space Craft Power System)

  • 김희준;김영태;김인기;최종문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.886-888
    • /
    • 1993
  • Recently current mode control is widely adopted in switching power converter because of inherent stablity and ability of parallel operating. There are several ways in current mode control. One of them, peak current control is chiefly employed. Peak current mode control converter usually senses and controls peak inductor current. But there is peak-to-average current errors. Therefore peak current control needs compensation ramp correcting the errors. Average current mode control eliminates these problems, and is constructed by simple structures. This paper will describe the behavior of a simple average current mode boost converter and introduce the design techniques.

  • PDF

중성선 전류 제거를 위한 3상 4선식 능동 전력 필터 (Neutral line current elimination method for Active power filter of three phase four-wire power system)

  • 민준기;김효성;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1489-1491
    • /
    • 2005
  • This paper proposes a design method using PQR instantaneous power theory on the active power filter, unbalanced nonlinear load condition and unbalanced source voltage condition in three-phase four-wire systems. For reduction of current harmonics and neutral current, the control structure including repetitive controller is proposed and controller gain is designed. For fully-digital implementation, ramp comparison PWM method was adopted. Simulation results verify good performance of the proposed current control strategy on the shunt APFs.

  • PDF

GMA 용접에서 전압과 전류의 동특성에 관한 연구 (A Study on Dynamic Characteristics of Welding voltage and Welding Current At GMAW)

  • 김면희;최영근;이문환
    • 한국산업융합학회 논문집
    • /
    • 제4권2호
    • /
    • pp.207-213
    • /
    • 2001
  • Welding variables and condition in gas metal arc welding (GMAW) effect on the weld quality and productivity, extensive research efforts have been made to analyze the welding variables and conditions. In this study dynamic behavior of GMAW system is investigated using the chararcteristic equations of the power supply. wire and welding arc. Characteristic equation of wire is modified to include the effect of droplets attached at the electrode tip. The dynamic characteristics of arc length, current, voltage with respect to the step, ramp inputs of CTWD was simulated. From results of simulation, some predictions about dynamic characteristics of GMAW and welding process are available. The proposed simulator and results appear to be utilized to determine the proper welding conditions, to be improved by considering power supply dynamic characteristics.

  • PDF

An Experimental Study on IMP-based and DOB-based Controllers for Position Control of a BLDC Motor System

  • Dong Cheol Song;Seung Tae Hwang;Nebiyeleul Daniel Amare;Young Ik Son
    • 반도체디스플레이기술학회지
    • /
    • 제23권2호
    • /
    • pp.92-99
    • /
    • 2024
  • As semiconductor processes require several nanometers precision, the importance of motor control is increasing in semiconductor equipment. Due to unpredictable uncertainties such as friction and mechanical vibrations achieving precise position control in semiconductor processes is challenging. The internal model principle-based controller is a control technique that ensures robust steady-state performance by incorporating a model of the reference and disturbance. The disturbance observer-based controller is a prominent robust control technique implemented to cope with various nonlinearities and uncertainties. Provided that the two controllers can be designed to exhibit equivalent performance under certain conditions, this paper demonstrates through experiments that they yield identical results for the case of a BLDC position control problem. The experimental results also indicate that they can offer enhanced robustness compared with the conventional PID controller in the presence of a time-varying disturbance.

  • PDF

Quench Protection System for the KSTAR Toroidal Field Superconducting Coil

  • Lee, Dong-Keun;Choi, Jae-Hoon;Jin, Jong-Kook;Hahn, Sang-Hee;Kim, Yaung-Soo;Ahn, Hyun-Sik;Jang, Gye-Yong;Yun, Min-Seong;Seong, Dae-Kyoung;Shin, Hyun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.178-183
    • /
    • 2012
  • The design of the integrated quench protection (QP) system for the high current superconducting magnet (SCM) has been fabricated and tested for the toroidal field (TF) coil system of the Korea Superconducting Tokamak Advanced Research (KSTAR) device. The QP system is capable of protecting the TF SCM, which consists of 16 identical coils serially connected with a stored energy of 495 MJ at the design operation level at 35.2 kA per turn. Given that the power supply for the TF coils can only ramp up and maintain the coil current, the design of the QP system includes two features. The first is a basic fast discharge function to protect the TF SCM by a dump resistor circuit with a 7 s time constant in case of coil quench event. The second is a slow discharge function with a time constant of 360 s for a daily TF discharge or for a stop demand from the tokamak control system. The QP system has been successfully tested up to 40 kA with a short circuit and up to 34 kA with TF SCM in the second campaign of KSTAR. This paper describes the characteristics of the TF QP systems and test results of the plasma experiment of KSTAR in 2009.

단기적 자율조절기능을 포함하는 심혈관계 혈류역학 모델링에 관한 수치적 연구 (Computational Study on the Hemodynamics of Cardiovascular System Including Short-term Auto-regulation Functions)

  • 심은보;정찬일;최한고
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권5호
    • /
    • pp.393-402
    • /
    • 2001
  • 전체 심혈관계의 혈류역학적 특성을 분석할 수 있는 수치해석 방법을 개발하였다. 이는 12개의 요소들로 구성된 lumped parameter모델에 기초하고 있으며 인체의 신경계에 의한 자율조절기능을 모사하기 위해 주로 혈압의 단기적 조절을 위한.baroreflex system뿐 아니라 cardiopulmonary reflex 메커니즘가지도 구현하여 모델에 포함시켰다. 또한 교감 및 부교감 신경에 의한 자극-반응 전달을 구현함에 있어 생리학적 데이터에 기초한 방법을 사용하였다. 본 연구의 수치해석 코드를 검증하기 위하여 우선 보통 상태의 심혈관계에 대하여 혈류역학적 계산 결과를 기존의 참고문헌들에서의 값들과 비교 검토하였다. 심혈관계 모델의 혈류역학적 자극에 대한 반응 결과를 조사하기 위하여. 20% 출혈이 발생하는 경우와 LBNP(Lower Body Negative Pressure) 모사를 수행하였다. 두 경우 모두. 비교적 실험치와 잘 일cl하고 있음을 확인할 수 있었다. 특히 LBNP 수행 시, 외부압력의 크기가 커질수록 baroreflex만을 포함하고 있는 방법은 baroreflex와 cardiopulmonary reflex 모두를 포함하고 있는 방법에 비하여 다소 부정확한 결과를 보여주고 있는데. 이는 cardiopulmonary reflex 메커니즘의 중요성을 보여주고 있다.

  • PDF

Security Cost Analysis with Linear Ramp Model using Contingency Constrained Optimal Power Flow

  • Lyu, Jae-kun;Kim, Mun-Kyeom;Park, Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권3호
    • /
    • pp.353-359
    • /
    • 2009
  • This paper proposes a novel technique for calculating the security costs that properly includes ramping constraints in the operation of a deregulated power system. The ramping process is modeled by a piecewise linear function with certain assumptions. During this process, a ramping cost is incurred if the permissible limits are exceeded. The optimal production costs of the power producers are calculated with the ramping cost included, considering a time horizon with N-1 contingency cases using contingency constrained optimal power flow (CCOPF), which is solved by the primal-dual interior point method (PDIPM). A contingency analysis is also performed taking into account the severity index of transmission line outages and its sensitivity analysis. The results from an illustrative case study based on the IEEE 30-bus system are analyzed. One attractive feature of the proposed approach is that an optimal solution is more realistic than the conventional approach because it satisfies physical constraints, such as the ramping constraint.

Secant Method for Economic Dispatch with Generator Constraints and Transmission Losses

  • Chandram, K.;Subrahmanyam, N.;Sydulu, M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.52-59
    • /
    • 2008
  • This paper describes the secant method for solving the economic dispatch (ED) problem with generator constraints and transmission losses. The ED problem is an important optimization problem in the economic operation of a power system. The proposed algorithm involves selection of minimum and maximum incremental costs (lambda values) and then the evaluation of optimal lambda at required power demand is done by secant method. The proposed algorithm has been tested on a power system having 6, 15, and 40 generating units. Studies have been made on the proposed method to solve the ED problem by taking 120 and 200 units with generator constraints. Simulation results of the proposed approach were compared in terms of solution quality, convergence characteristics, and computation efficiency with conventional methods such as lambda iterative method, heuristic methods such as genetic algorithm, and meta-heuristic methods like particle swarm optimization. It is observed from different case studies that the proposed method provides qualitative solutions with less computational time compared to various methods available in the literature.