• Title/Summary/Keyword: railway test line

Search Result 388, Processing Time 0.029 seconds

A study on a design method and characteristic analysis of a LSM for a propulsion/levitation of the high-speed tube train (초고속튜브열차 추진/부상용 LSM의 설계 기법 및 특성 분석 연구)

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Byung-Song;Kim, Nam-Po;Park, Hyun-June
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.830-837
    • /
    • 2010
  • Since it started the researches on a maglev train on 1960, Germany and Japan arrived to putting to practical use level and accomplished most tests from their test-line. Korea is in progress the preparation for a practical use of low-speed maglev train in 110 [km/h] class and Korea Railroad Research Institute(KRRI) is in progress of a research about core technology of maglev system for high-speed tube train of 700 [km/h] class. In this paper, authors suggest an effective design method of Linear Synchronous Motor(LSM) for high-speed tube train of 700 [km/h] class which has a wound type electro-magnet. Then, authors calculate a variety of properties by changing speed of the LSM model which is designed by a method based on some theoretical equations. Then, authors verify the validity of the method based on some theoretical equations through a verification of property values by Finite Element Method(FEM) analysis method. Finally, in order to design a shape of pole-shoe part of LSM electro-magnet which is hard to design with a basic design method, authors analyze a transition of property values by changing a pole-shoe width and current of the electro-magnet through an analytical method by FEM.

  • PDF

The THD measurement of HEP equipment power installed on 8200 series Electric locomotive (8200대 신형 전기기관차 HEP 장치 고조파 왜율 측정)

  • Kim, Dae-Sung;Lee, Kyung-Rac;Ahn, Hong-Goan;Park, Jong-Chun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.488-497
    • /
    • 2010
  • 8100 series Electric locomotive was imported from SIEMENS of Germany on 2001. 8100 series model is modified from BR152 model to be complied with national environment. After 8100 series Electric locomotive carried out main line test for long time, 8200 series Electric locomotive produced in 10 locomotives with improvement and supplement on some parts. the one of supplement is to install the HEP equipment. In paper, about total harmonic distortion of HEP equipment power, it compares the result of combination with the result of actual measurement. It checks whether the measurement meets the specification of design or not. And it describes international standard about total harmonic distortion of supply system.

  • PDF

Fatigue Life Evaluation of Motor Block Bracket Units for KTX-Sancheon Trains (KTX-산천 열차용 모터 감속기 고정대의 피로 수명 평가)

  • Lee, Chan-Woo;Lee, Dong-Hyong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.6
    • /
    • pp.626-631
    • /
    • 2012
  • In this study, fatigue life of the motor block bracket units for KTX-Sancheon trains was assessed. Design evaluation for railway structures was performed based on the UIC 566 regulation, and test and evaluation of fatigue life in welded parts was performed in accordance with standard ERRI B 12/RP17 and ERRI B 12/RP60. The actual vehicle dynamic stress testing was executed in KTX-Sancheon service line with the service operating speed. The dynamic stress was measured with commercial data acquisition system (MGC plus). The cumulative damage was evaluated by applying standard BS 7608 - Class F and cycle counting was used rain-flow counting method. As a result, the motor block bracket units for KTX-Sancheon trains was designed to fit the regulation and the safety of fatigue life for 30 years, assuming that KTX-Sancheon trains travels 600,000km annually, were confirmed under current operating conditions.

A Study on the Rail Pone of Transition Curve Track to Speed Up of Tilting train (틸팅차량 완화곡선 증속 주행시 궤도작용력 검토)

  • Shin, Tae-Hyoung;Choi, Jung-Youl;Eum, Ki-Young;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.529-538
    • /
    • 2009
  • A trial run of locally-developed tilting train has been in process on Chungbuk line since the test vehicle was first produced. For the system stabilization, interface verification among the systems including track, structure, catenary and signaling system, not to mention the rolling stock, is very crucial. Therefore, in this study, the dynamic rail force of the tilting (Hanvit 200), high-speed (KTX) and general (Mugunghwa) vehicle caused by driving in transition curve track was measured. And, it compared the tilting response with the other by using the measured wheel load data in transition curve track, and then evaluated probability the range of wheel load fluctuation for the variable dynamic vertical and lateral wheel load. As a result, a range of wheel load by occured a change of cant from the high-speed and general vehicle which had fixed bogie structure was distributed throughout small deviation (${\Delta}8{\sim}13kN$). Otherwise, in case of the tilting train which was consisted of the pendulum bogie structure was distributed wide range about large deviation (${\Delta}25{\sim}28kN$) by changed of cant.

  • PDF

Characteristics of Behavior of the Soft Roadbed through Long-Term Instrumentation on the Field Test (운행선상의 연약노반 시험부설구간에서의 장기계측을 통한 거동 특성)

  • Lee Jin-Wook;Choi Chan-Yong;Lee Sung-Hyok;Lee Cnang-Youl
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1058-1064
    • /
    • 2004
  • As one of reinforcing methods for soft roadbed, the problems that mud-pumping and settlement occurred by soft roadbed, were investigated, evaluated and analyzed through installing relatively economical and efficient geosynthetics on the selected track-bed for testing. Mock-heang to Dong-ryang on the filed resting sections in the Chung-buk lines were selected as investigating the state of track and prepared field after selecting three of 1,700 spots which often make mud-pumping and requiting maintenance for that. Long curved line radiuses(R) of Mock-heang to Dong-ryang are 500m that were installed with 4 types of geosynthetics layers and one ballast layer. Installed testing cross-section is 200m totally with 40 m between places. Strength or prepared roadbed was measured to investigate the state of roadbed and track with constructing(installing) field testing sections and physical properties of roadbed soils were evaluated and analyzed. Also, mud-pumping, settlement of elastic or plastic sleeper, failure or track, wheel-loads, transverse and earth pressures were measured after installing field testing sections.

  • PDF

Seismic response of combined retaining structure with inclined rock slope

  • Yu-liang, Lin;Jie, Jin;Zhi-hao, Jiang;Wei, Liu;Hai-dong, Liu;Rou-feng, Li;Xiang, Liu
    • Structural Engineering and Mechanics
    • /
    • v.84 no.5
    • /
    • pp.591-604
    • /
    • 2022
  • A gravity wall combined with an anchoring lattice frame (a combined retaining structure) is adopted at a typical engineering site at Dali-Ruili Railway Line China. Where, the combined retaining structure supports a soil deposit covering on different inclined rock slopes. With an aim to investigate and compare the effects of inclined rock slopes on the response of combined retaining structure under seismic excitation, three groups of shaking table tests are conducted. The rock slopes are shaped as planar surfaces inclined at angles of 20°, 30°, and 40° with the horizontal, respectively. The shaking table tests are supplemented by dynamic numerical simulations. The results regarding the horizontal acceleration response, vertical acceleration response, permanent displacement mode, and axial anchor force are comparatively examined. The acceleration response is more susceptible to outer structural profile of combined retaining structure than to inclined angle of rock slope. The permanent displacement decreases when the inclined angle of the rock slope increases within a range of 20°-40°. A critical inclined angle of rock slope exists within a range of 20°-40°, and induces the largest axial anchor force in the combined retaining structure.

Analysis of Correlation Between Wonhyo Tunnel(section of KTX line) Works and Swamp (경부고속철도 천성산구간 원효터널공사와 늪지와의 상관성 분석)

  • Ham, Dong-Sun;Kim, Byeong-Ho;Jeon, Byeong-Gyoo;Kim, In-Soo
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1838-1844
    • /
    • 2007
  • The Wonhyo Tunnel on KTX railroad line is a section of latest concerns from domestic environmental NGOs, which focus on potential destruction of ecosystem or the like due to ever-depleted swamp water at about 300m upward from the tunnel under construction. As a result of study, out of all swamps in the vicinity of the tunnel, it was found that Mujechi 1st and 2nd swamps have been getting smaller in their area little by little since 50 years ago primarily under the influence of eroded streams around lower swamp and even ever-increasing annual mean temperature. As the result of monitoring about swamp before work, it was found that swamp water depends absolutely on amount of rainfall. Besides, the results of monitoring during work also didn't show any leakage generated in the tunnel during and after excavation works with regard to a wheat field swamp in the most vicinity of the tunnel (80m away). On the other hand, it was found that the range affected by ground water sink in tunnel section without grouting process amounted to about 100m around the tunnel, which indicates that such ground water sink has no significant impact upon most of swamps near the tunnel. As the result of testing by two well tracer test around swamps, it was noted that swamp water didn't run out from the bottom of swamp even with adjacent ground water level sunk in factitious ways. And the results of physical survey showed that swamp kept saturated even in dry season when ground water level becomes lower than the bottom of swamp. Therefore, even supposing that ground water level becomes sunk due to tunnel works, it is estimated that the water level of swamps would be still kept owing to impervious layer(peat beds).

  • PDF

Parameter Estimation of Gravity Model by using Transit Smart Card Data (대중교통 카드를 이용한 중력모형 파라메타 추정)

  • Kim, Dae-Seong;Lim, Yong-Taek;Eom, Jin-Ki;Lee, Jun
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1799-1810
    • /
    • 2011
  • Origin-Destination(OD) trip survey being used in travel demand forecasting has been obtained through totalizing process with direct sample survey techniques such as plate license survey, roadside interview, household travel survey, and cordon line counts. However, the OD survey has many discrepancies in sampling, totalizing process, and such discrepancies contains problems of difference between forecasted traffic volume and observed data. On the other hand, transit smart card data recently collected has credible resource of obtaining travel information for bus and metro. This paper presents parameter estimation of gravity model by using transit smart card data. Through the parameter estimation method, we estimated =0.57, ${\beta}$=0.14 of gravity model for bus, and ${\alpha}$=-0.21, ${\beta}$=0.05 for metro. The statistical test such as T-test, coefficient of correlation, Theil`s inequality coefficient showed no difference between observed volume and estimated volume. Elasticities of bus and metro derived in this paper are also reasonable.

  • PDF

The Development of Third-Rail System Applied to Turn-out Section for Urban Maglev (도시형 자기부상열차 분기기 구간의 제3궤조 전차선 시스템 개발)

  • Min, Byong-Chan;Heo, Young-Tae;Hong, Du-Young;Lee, Won-Joo;Jo, Su-Yeon;Jeong, Nam-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3046-3051
    • /
    • 2011
  • The third-rail system is an important device supplying power directly to the Maglev train through physical contact with the collecting shoe. It is directly related to safety and reliability for the running of Maglev. However, most the third-rail system used in Korea depend on foreign product or technologies, Korea Urban Maglev in the development of appropriate power feeding is urgent. In particular, the turnout section is the weakness point in the system because bending force by turnout section movement and fatigue caused by repetitive motion as well as the expansion by temperature, the forces by Maglev collecting shoe is added th the third-rail. Therefore, this paper proposes the third-rail system appropriate for Korean Urban Maglev of turnout section. To verify the structural stability of POSCO ICT third-rail system, the finite element analysis and physical testing was performed. The third-rail is fixed on each side of the turn-out section steel structure by epoxy insulation supporter and the integral behaviors are occurred. Therefore, the maximum horizontal displacements of each support are investigated and then, it is applied to finite element model of the third-rail to investigate the moments and stress. Also, the bending test about one million times and Expansion Joint for the third-rail was performed. The third-rail system safety and reliability was identified by test line on Korea Institute of Machinery & Materials in Deajeon for under the actual usage environment such as the Maglev and turn-out operation.

  • PDF

A Study of Characteristics on Weathering for Decomposed Granite Soils in Cutting Slope (화강토 지반 절취사면의 풍화특성에 관한 연구)

  • Lee, Song;Kim, Ju-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.451-458
    • /
    • 2001
  • The purpose of this study was to evaluate shear parameters on cutting slope of weathered granite soils by using small dynamic cone penetration test on the very moment of its cutting. The results were : On the relations among N$\_$c/, Li, and CEC, the condition of Li>6%, CEC>14(meq/100g) corresponds to that of N$\_$c/ values of 2∼30, and 3<CEC<14(meq/100g) to N$\_$c/=30∼50. Comparing the smallest penetration depth from two small dynamic cone penetration tests done at 5m below from the top of the slope on April 15th, October 31t. there was a l0cm difference. So we could find out the degree of weathering on the slope. And dividing the difference by 190 days (the whole testing time), we could know it's being weathered 0.052mm each day. The more N. value increases, the more shear parameters(internal friction angle ; $\phi$, cohesion : c) increase at a standard pressure($\sigma$>32㎪). So the condition of N$\_$c/=2∼50 corresponds to that of $\phi$=27∼50, c=12∼49㎪. From the above testing results, the N$\_$c/ values more correspond to $\phi$ values than c values. In conclusion, this study suggests that on small dynamic cone penetration test a penetration boundary line of 5 centimeters is decided at around Li=4%, CEC=3(meq/100g) which is classified as a strong weathering soil. It also shows that as Li increases CEC increases as well, while N$\_$c/ decreases.

  • PDF