• 제목/요약/키워드: railroad voltage analysis

검색결과 63건 처리시간 0.03초

단자망을 이용한 직류전기철도 해석방안에 관한 연구 (A Study on Analysis Method of DC Electric Railroad using Terminal Network Analysis)

  • 이장무;장동욱;김재원;한문섭;정환수;김주락
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1913-1918
    • /
    • 2016
  • In order to analyze the power consumption pattern of the DC urban rail system, the method to obtain a solution establishing the current equation according to fixed position of the substation and varying position of the train is used. The proposed analysis method using the network analysis is to model the transfer function of the component constituting a direct current power supply system (dc substation, train, catenary) to the voltage and current. By multiplying the model formula consecutive, it can calculate the voltage and current of each element of power supply circuit and shows a simple case analysis.

능동형 전압제어를 통한 교류 전기철도 급전망에 대한 전력손실 분석 (A Power Losses Analysis of AC Railway Power Feeding Network using Adaptive Voltage Control)

  • 정호성;김형철;신승권;김진호;윤기용;조용현
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1621-1627
    • /
    • 2013
  • This paper compares power losses between voltage controlled before and after using power conversion device in AC feeding system. For this purpose we present voltage control procedures and criteria and model high speed line and train using PSCAD/EMTDC to compare power losses in various feeding condition. Power losses of the simulation result in power control before and after in single point feeding system was reduced maximum 0.37 MW(23.8 %) and average 0.23 MW(20.5 %) when one vehicle load operates maximum load condition. When three vehicles operate maximum load condition in one feeder section, power losses after voltage control was reduced 1.03 MW(49.5%) compared to before voltage control. And, power loss of parallel feeding system is reduced the average 0.08 MW(7.2 %) compared to the single feeding system. In conclusion, adaptive voltage control method using power conversion device can reduce power losses compared with existing method.

Energy Storage Application Strategy on DC Electric Railroad System using a Novel Railroad Analysis Algorithm

  • Lee, Han-Sang;Lee, Han-Min;Lee, Chang-Mu;Jang, Gil-Soo;Kim, Gil-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.228-238
    • /
    • 2010
  • There is an increasing interest in research to help overcome the energy crisis that has been focused on energy storage applications in various parts of power systems. Energy storage systems are good at enhancing the reliability or improving the efficiency of a power system by creating a time gap between the generation and the consumption of power. As a contribution to the various applications of storage devices, this paper describes a novel algorithm that determines the power and storage capacity of selected energy storage devices in order to improve upon railroad system efficiency. The algorithm is also demonstrated by means of simulation studies for the Korean railroad lines now in service. A part of this novel algorithm includes the DC railroad powerflow algorithm that considers the mobility of railroad vehicles, which is necessary because the electric railroad system has a distinct distribution system where the location and power of vehicles are not fixed values. In order to derive a more accurate powerflow result, this algorithm has been designed to consider the rail voltage as well as the feeder voltage for calculating the vehicle voltage. By applying the resultant control scheme, the charging or discharging within a specific voltage boundary, energy savings and a substation voltage stabilization using storage devices are achieved at the same time.

STATCOM을 이용한 교류 전기철도 급전시스템의 전압강하 보상 (Compensate Voltage Drop for Autotransformer-Fed AC Electric Railroad System with Single-Phase STATCOM)

  • 정현수;이승혁;김진오
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.53-60
    • /
    • 2002
  • 본 논문에서는 정전류 부하모델 교류 전기철도 AT 급전시스템을 회로망 해석법(Loop Equation Method)을 이용하여 실제 급전시스템과 유사하게 제약조건을 두고 여러 경우를 가정하여 모델링 하였다. 이 방법을 통해 앞으로 건설될 고속 전기철도 급전시스템의 전력품질에 영향을 줄 수 있는 전압강하에 주안점을 두고 정상급전의 경우뿐만 아니라 연장급전의 경우를 새롭게 확대 해석하였으며 이 결과를 동적 시뮬레이션 프로그램인 PSCAD /EMTDC를 이용하여 그 정확성과 실용성을 검증하였다. 또한 사례연구를 통해 전압 보상기를 설치하지 않는 경우와 STATCOM을 설치한 경우의 전압강하 보상효과를 PSCAD/EMTDC로 시뮬레이션 하여 검증하였다.

전철부하에 기인된 계통 전압불평형 평가기법 (Evaluation Techniques for the Voltage Unbalance due to Railway Demand)

  • 오광해;창상훈;한문섭;이장무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.787-789
    • /
    • 1997
  • This paper presents an algorithm to estimate voltage unbalance which is due to railway demand, and which is most troublesome to polyphase motors. For the sake of accuracy, a circuit analysis procedure is introduced in this algorithm. The circuit analysis procedure enables the algorithm to produce a voltage and current profiles as well as unbalance indices. The proposed algorithm is applied to the test system(standard AT fed system) for the analyses of unbalance phenomena. The result shows that the algorithm is useful in the field of railway system planning.

  • PDF

전기철도 급전시스템의 안정화를 위한 전압강하 측정 결과 분석 (Measurement and Analysis of Voltage Drop in Traction Power Supply System)

  • 김주락;이영흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2210-2211
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

선형인공신경망을 이용한 직류 전철변전소의 RC 회로정수 추정 (RC Circuit Parameter Estimation for DC Electric Traction Substation Using Linear Artificial Neural Network Scheme)

  • 배창한;김영국;박찬경;김용기;한문섭
    • 한국철도학회논문집
    • /
    • 제19권3호
    • /
    • pp.314-323
    • /
    • 2016
  • 직류 전철변전소의 가선전압은 전동차들의 회생제동 및 역행가속패턴에 따라 급격히 상승 또는 하강하는 특성을 갖는다. 가선전압 순시 변동폭을 최소로 유지함으로써, 전철변전소와 전동차들의 에너지 효율을 개선시키기 위한 다양한 연구들이 이루어지고 있다. 본 논문은 직류전철 변전소의 가선전압의 급격한 변동특성을 모델링하고 선형인공 신경망 알고리즘을 이용한 가선전압 회로모델의 파라메터 추정 방법을 제안하며, 최소자승법을 이용한 추정방법과의 비교를 통해 이 방법의 타당성을 입증한다. 가선전압 및 피더전류들의 누적 측정값을 사용하여 일괄처리 최소자승법으로 RC 병렬회로의 파라메터들을 추정한 결과를 제시하며, 실시간 가선전압 및 피더전류 측정값을 이용하여 오차역 전파방식으로 학습되는 선형인공신경망 기법 추정 결과를 분석한다.

EMTOC를 이용한 전기철도에서의 차량부하 패턴에 따른 전력공급 특성 해석 및 최적운전방안 제안 (Analysis of Power Supplying Characteristic Following Load Pattern Using EMTDC and Proposal for Optimal Operation)

  • 이한상;이장무;이한민;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.248-250
    • /
    • 2004
  • Following the needs for increment of public transportation system electric railroad system should be expended. There are several solutions to expend. One of these solutions is to reduce the interval between two railroad vehicles. However, it cannot be reduced too much because reduction of interval means increment of loads and induces supplying voltage decrement. In this paper, voltage variation according to railroad intervals is simulated and optimal operation in railroad system is proposed.

  • PDF

단권변압기 교류전기철도 급전시스템의 전차선 전압해석 (Analysis for Catenary Voltage of The ATs-Fed AC Electric Railroad System)

  • 정현수;이승혁;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권9호
    • /
    • pp.493-499
    • /
    • 2003
  • This paper presents exact Autotransformers(ATs)-fed AC electric Railroad system modeling using constant current mode for locomotives. An AC electric railroad system is rapidly changing single-phase load, and at a feeding substation, 3-phase electric power is transferred to paired directional single-phase electric power. As the train moves along a section of line between two adjacent ATs. The proposed AC electric railroad system modeling method considers the line self-impedances and mutual-impedances. The constant current mode model objectives are to calculate the catenary and rail voltages with the loop equation. When there are more than one train in the AC electric railroad system, the principle of superposition applies and the only difference between the system analyses for one train. Filially, this paper shows the general equation of an AC electric railroad system, and that equation has no relation with trains number, trains position, and feeding distance.

교류전기철도시스템에서 급전계통 구성에 따른 급전성능 비교검토 (The comparison and investigation of power supply capability according to feeding schemes in AC electric railway system)

  • 이장무;오광해;창상훈;한문섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1236-1238
    • /
    • 2001
  • The electrified railway has various power supply schemes. Although the identical trains are operated in same condition and the impedance of track are equal, the genealogy impedance of track is changed according to composition method of feeding scheme. So, the collection voltage of train and supplying power from railway substation are greatly unlike. For simulation of collection voltage and power supply according to feeding scheme, using 6-port network analysis proposed previously simulate collection voltage and supply power according to feeding scheme(Parallel Post feeding system, normal feeding system and tie feeding system) and compare and investigate each characteristics.

  • PDF