• 제목/요약/키워드: radius fracture

검색결과 192건 처리시간 0.026초

노치/균열 임계평균응력 파손모델을 이용한 임계노치반경 평가 (Evaluation of Critical Notch radius using Notch/Crack Critical Average Stress Fracture Model)

  • 김재훈;김덕회;김기수;안병욱
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1358-1361
    • /
    • 2003
  • In this study, intrinsic static/dynamic fracture toughness of Al 7175-T74 are evaluated from the apparent static/dynamic toughness of notched specimen. The notch/crack critical average stress fracture model is suggested to establish the relationship to predict the intrinsic fracture toughness from the apparent fracture toughness of a notched specimen. The notch/crack critical average stress fracture model is established using the relation between the notch root radius and the effective distance calculated by finite element analysis. It is conclude that the true fracture toughness can be estimated from test results of apparent fracture toughness measured by using a notched specimen. Also, critical notch root radius can be predicted by notch/crack critical average stress fracture model.

  • PDF

$^ {99m}Tc-MDP$를 이용한 개의 요골 골절 치유 과정의 평가 (Evaluation of Fracture Healing in Canine Radius by Bone Scan with $^ {99m}Tc-MDP$)

  • 김남수
    • 한국임상수의학회지
    • /
    • 제16권2호
    • /
    • pp.293-299
    • /
    • 1999
  • Bone scintigraphy with $^{99m}Tc-methylene$ diphosphonate(MDP) performed for 20 weeks per two weeks interval respectively after fracture in seven(male 3 heads, female 4 heads) canine radius were analysed. All of bone scans performed 2 weeks to 20 weeks after fracture showed increase in generalized tracer uptake and showed localized increase in tracer uptake at the fracture site. Bone scans and ratio performed 6 weeks after fracture showed the most outstanding increase in generalized and localized tracer uptake. New bone formation had been observed from 2 weeks and they were incorporated completely on 18 weeks, they showed most activity during 6-10 weeks after fracture. It was recognized that the bone scan with $^{99m}Tc-methylene$ was quite sensitivity but low specificity on the fracture healing in canine radius.

  • PDF

요골 원위부 골절 후 발생한 급성 장무지 신전건 파열 -1예 보고- (Acute Rupture of Extensor Pollicis Longus Tendon after Distal Radius Fracture: A Case Report)

  • 황정철;정덕환
    • 대한정형외과 초음파학회지
    • /
    • 제4권1호
    • /
    • pp.24-27
    • /
    • 2011
  • 원위부 요골 골절의 합병증 중 하나인 장무지 신전건 파열은 지연성으로 발생한다고 알려져 있다. 요골 골절과 동시에 발생하는 급성 장무지 신전건 파열은 매우 드문 경우로, 저자들은 문헌 고찰과 함께 증례 보고 하고자 한다.

  • PDF

다양한 노치 반경을 갖는 17-4PH강의 동적균열개시 특성 (Dynamic Crack Initiation of 17-4PH Casting Steel for Various Notch Radius)

  • 박성욱;김덕회;김재훈;문순일
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.160-163
    • /
    • 2003
  • 본 논문에서는 17-4PH강의 동적파괴인성을 노치시편의 겉보기 동적파괴인성으로부터 평가하고자 한다. 0.1mm∼4mm의 다양한 노치반경을 갖는 시험편을 이용하였다. 임계노치반경 이상에서는 노치 반경이 증가할수록 겉보기 동적파괴인성도 증가하는 결과를 보인다. 노치시편을 이용하여 측정한 겉보기 동적파괴인성으로부터 동적파괴인성을 예측할 수 있다.

  • PDF

Al 7175 합금의 정적 파괴인성에 미치는 노치반경 영향 (Notch Radius Effect for Static Fracture Toughness of Al 7175 Alloys)

  • 김재훈;김덕회;박성욱;문순일
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2002년도 제18회 학술발표대회 논문초록집
    • /
    • pp.84-87
    • /
    • 2002
  • In this study, intrinsic fracture toughness of Al 7175-T74 is evaluated from the apparent toughness of notched specimen. Modified average stress model is used to establish the relationship to predict the intrinsic fracture toughness from the apparent fracture toughness of a notched-cracked specimen. The modified average stress model is established the relation between notch radius and effective distance calculated by FEM analysis. The results show that fracture toughness decreases with decreasing of notch root radius. The true fracture toughness can be predicted from test results of apparent fracture toughness measured by using notched specimen.

  • PDF

연성 균열성장 개시의 미시적 파괴조건 (Microscopic fracture criterion of crack growth initiation)

  • 구인회
    • 대한기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.740-745
    • /
    • 1987
  • 본 연구에서는 파괴조건(4)와 유사하게 임계 스트레인 조건을 사용하나 기존 스트레인이 없는 재료의 날카로운 균열선단을 가진 시편의 파괴인성실험치(.delta.$_{IC}$)로 부터 재료의 고유상수인 특성길이를 결정하는 방법이 제안되었다.이 파괴조건을 이 용하여 처음노치선단의 유한한 반경과 재료의 기존 스트레인이 시편의 파괴개시에 미 치는 영향을 예측하고자 한다.

원위 요골 골절에 대한 한방 재활치료 프로토콜 적용의 임상적 효과: 증례 보고 (The Clinical Effect of Rehabilitation Protocol for Distal Radius Fracture in Korean Medicine: A Report of 3 Cases)

  • 하원배;금지혜;고낙용;이정한
    • 한방재활의학과학회지
    • /
    • 제28권3호
    • /
    • pp.97-106
    • /
    • 2018
  • The objective of this study was to propose a rehabilitation protocol for distal radius fracture in Korean Medicine and to report its effectiveness. Three patients who had undergone distal radius fracture were treated using the rehabilitation protocol in Korean Medicine. We estimated the outcome evaluating physical examination findings of the wrist joint, numeric rating scale and quick the Disabilities of the Arm, Shoulder and Hand (DASH) score. After the treatment, we observed that wrist movement, numeric rating scale and quick DASH score were improved. A rehabilitation in Korean Medicine can be effectively used for distal radius fracture patients. The limitation of this study was the insufficient number of cases. Further studies are needed to design a rehabilitation protocol in Korean Medicine.

Treatment of Radius Fracture Using a Shuttle Pin in a Cinereous Vulture (Aegypius monachus): A Case Study

  • Jinho Jang;Hee-Jong Kim;Young-Seok Park;YoungMin Yun
    • 한국임상수의학회지
    • /
    • 제41권3호
    • /
    • pp.189-194
    • /
    • 2024
  • Cinereous vulture (Aegypius monachus) is a large raptor that belongs to the family Accipitridae in the order Falconiformes. It is a migratory bird that returns to Mongolia after wintering in the Korean Peninsula. In February 2015, a cinereous vulture was rescued from Asan-si, Chungcheongnam-do Province as it could not fly. It was transferred to the Chungnam Wild Animal Rescue Center in Korea. It was found to have a closed fracture on the right radius through radiographic examination, a basic procedure. Surgery was performed at the fracture site using a shuttle pin and wire. After successful physical therapy and rehabilitation, the cinereous vulture was released in October 2015. A metal ring (150-00713) and wing tags (G/BL 3) were attached to the bird before its release for subsequent identification. Two years and 4 months later, in March 2018, the cinereous vulture was rescued and brought back to the center. It was diagnosed with secondary pesticide poisoning. After receiving treatment, a radiography test revealed no specific findings related to the previous fracture surgery. Considering that migratory birds travel long distances, it was confirmed that the treatment for reducing the fracture in the radius using a shuttle pin and a cerclage wire was suitable.

소아 요골 원위부 불안정 골절의 캐스트 후 안정성에 영향을 미치는 요소 (Risk Factors in Stability after Immobilization of the Distal Radius in Unstable Fractures in Children)

  • 신용운;손종민;박상윤
    • 대한정형외과학회지
    • /
    • 제56권3호
    • /
    • pp.215-223
    • /
    • 2021
  • 목적: 소아 요골 원위부 골절은 가장 흔한 골절이면서 불안정 골절의 경우 정복 후에도 재전위 위험성이 높아 주의가 요망된다. 이러한 재전위에 영향을 미치는 요인들에 대하여 평가해 보고자 한다. 대상 및 방법: 2011년 2월부터 2018년 6월까지 완전 전위된 소아 요골 원위부 불안정 골절로 본원 외래에서 보존적 치료한 6세에서 14세까지의 환자들을 대상으로 후향적 연구를 하였다. 전체 대상 환자 44예 중 재전위된 환자들에서 연령, 성별, 석고 지표, 간격 지표, 3점 고정 지표, 골절면 경사도, 관절면에서 골절선까지 거리를 환산한 골절 높이 비, 요골-제2 중수골 각도 등을 측정하여 마지막 골유합 상태에서 남은 각형성의 정도로 결과를 평가하여 비교를 하였다. 결과: 평균 9.2도(0-32.8도) 각형성이 남았으며 범주 내의 결과를 기준으로 하여 10도 미만이 29예, 10도 이상이 15예로 확인되었다. 정복 후 재전위가 발생한 군과 대조군 사이에 평가된 요소들 중 석고 지표들은 두 군 간에 차이가 없었다. 연령, 성별에서도 군 간에 차이가 없었고, 골절면 경사도, 요골-제2 중수골 각도도 차이가 없었다. 관절면에서 골절선까지의 거리를 환산한 골절 높이 비가 가장 의미 있는 안정요소로 평가되었고(p=0.001) 척골 골절이 동반된 경우도 불안정한 요소로 평가되었다(p=0.019). 결론: 소아 요골 간단부 완전 전위 골절, 특히 요골 골간단-골간 이행부의 골절의 경우 불안정한 골절로 평가되므로 좀 더 주의가 필요하며 충분한 재형성을 기대하기 어려운 연령에서는 만족스러운 결과를 위하여 수술적 치료가 선호될 수 있다.

요골골절에 사용된 금속판에 의한 장무지 굴곡건의 지연성 파열 (Delayed Rupture of Flexor Pollicis Longus by Plate for Fracture of the Distal Radius)

  • 황소민;안성민;오경석;김진형;이준호
    • Archives of Plastic Surgery
    • /
    • 제35권6호
    • /
    • pp.751-754
    • /
    • 2008
  • Purpose: Delayed rupture of flexor pollicis longus as a sequelae of the plate inserted for distal radius fracture is a very rare. This is the first case reported and published in Korea. Methods: A 48 years old female patient visited hospital, complaining flexor disturbance of interphalangeal joint of left thumb, which suddenly occurred without any external wound. We found that she had received operation of fixing plate for fracture of left distal radius 10 years ago. As operational opinion, we have checked that flexor pollicis longus tendon has been ruptured with oblique ways being stimulated by extended plate to palmar side over long period. Results: Authors performed tenorrhaphy of flexor pollicis longus without tendon graft and presented a successful active flexion of the left thumb interphalangeal joint 1 year after the operation. Conclusion: If the extruded part of the end plate is observed during the operation or follow-up, it is considered to be necessary to get rid of the plate as early as possible after the fracture healing.