• Title/Summary/Keyword: radioisotopes

Search Result 193, Processing Time 0.018 seconds

A Prediction Model for the Radiation Safety Management Behavior of Medical Cyclotrons (의료용 Cyclotron의 방사선안전관리 행위 예측모형)

  • Jung, Ji-Hye;Han, Eun-Ok;Kim, Ssang-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.77-86
    • /
    • 2008
  • This study attempted to provide reference materials for improving the behavior level in radiation safety managements by drawing a prediction model that affects the radiation safety management behavior because the radiation safety management of medical Cyclotrons, which can be used to produce radioisotopes, is an important factor that protects radiation caused diseases not only for radiological operators but average users. In addition, this study obtained follows results through the investigation applied from January 2 to January 30, 2008 for the radiation safety managers employed in 24 authorized organizations, which have already installed Cyclotrons, through applying a specific form of questionnaire in which the validity was guaranteed by reference study, site investigation, and focus discussion by related experts. The radiation safety management were configured as seven steps: Step 1 is a production preparation step, Step 2 is an RI production step, Step 3 is a synthesis step, Step 4 is a distribution step, Step 5 is a quality control step, Step 6 is a carriage container packing step, and Step 7 is a transportation step. it was recognized that the distribution step was the most exposed as 15 subjects (62.5%), the items of 'the sanction and permission related works' and 'the guarantee of installation facilities and production equipments' were the most difficult as 9 subjects (37.5%), and In the trouble steps in such exposure, the item of 'the synthesis and distribution' steps were 4 times, respectively (30.8%). In the score of the behavior level in radiation safety managements, the minimum and maximum scores were 2.42 and 4.00, respectively, and the average score was $3.46{\pm}0.47$ out of 4. Prosperity and well-being programs in the behavior and job in radiation safety managements (r=0.529) represented a significant correlation statistically. In the drawing of a prediction model based on the factors that affected the behavior in radiation safety managements, general characteristics, organization characteristics, and selfefficacy didn't show a significant path statistically in which the prosperity and well-being programs in job characteristics affected the behavior in radiation safety managements. Therefore, it is necessary to establish a strategy that improves the level of prosperity and well-being levels in job characteristics in order to increase the behavior in radiation safety managements. Thus, this study provides basic materials for the radiation safety management of Cyclotron through the full-scale investigation that is first applied in Korea.

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF