• Title/Summary/Keyword: radiation safety equipment

Search Result 134, Processing Time 0.031 seconds

Performance Based Design of Passive Fire Protection Using Consequence Analysis (사고 영향 분석을 이용한 성능위주의 내화설계)

  • Han, Dong-Hoon;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.102-107
    • /
    • 2004
  • Performance based design is a recent evolutionary step in the process of designing fire protection systems. In essence, it is a logical design process resulting in a solution that achieves a specified performance. Sometimes the prescriptive solutions presented in various codes and standards are too expensive or inflexible. Often the solutions do not and enables optimization of a solution for cost and function. In this study, performance based design was carried out to determine the extent of passive fire protection for oil terminal facilities. The results of performance based design were compared with those of prescriptive code based design. Performance based design is not always more economic than prescriptive code based design but provides more reliable and effective design that is fit for the purpose.

Factors Affecting Radiation Protection Behaviors among Emergency Room Nurses (응급실 간호사의 방사선 방어행위 영향요인)

  • Lee, Su Jin;Boo, Sunjoo;Ahn, Jeong-Ah;You, Mi-Ae
    • Journal of Korean Critical Care Nursing
    • /
    • v.13 no.1
    • /
    • pp.15-26
    • /
    • 2020
  • Purpose : This study aimed to examine factors affecting radiation protective behaviors among emergency room nurses by assessing knowledge, attitude, and environment for radiation protection. Methods : The study employed a cross-sectional design. Subjects were a convenience sample of 129 nurses working in emergency rooms of three general hospitals. Data were collected using self-report questionnaires and analyzed using t-test, ANOVA, Pearson correlation coefficients, and multiple regression. Results : The more the nurses received radiation safety education (t=2.26, p=.026), used protective gear (t=4.40, p<.001), and took health screenings (t=2.65, p=.009), the higher their levels of radiation protection behavior. There were significant relations between radiation protective behaviors and attitude (r=.27, p=.002), and radiation protective behaviors and environment for radiation protection (r=.55, p<.001). The factors affecting radiation protective behaviors were protective environment (β=.53, p<.001), protective attitude (β=.32, p<.001), and the use of protective gear (β=.24, p=.002). Conclusions : The government, hospital administrators, and radiation protection-related organization should adopt the following measures to protect emergency room nurses from radiation: research and development of shield instrument, medical examination for emergency room nurses, protocol development of radiation protection behaviors, extension of education chances of radiation protection, and encouraging the use of protective equipment.

Automatic real-name registration mark examiner research and development of special medical equipment for patient safety (환자 안전을 위한 특수의료장비의 검사자 실명제 자동 표식 등록 개발 연구)

  • Yoo, Se-Jong;Park, Jong-Bae;Kim, Jeong-Ho;Kim, Ki-Jin;Lim, Jae-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.147-152
    • /
    • 2015
  • Through the inspector's real name to improve the quality of inspection is to show the design Radiological examination pursuant to the Ordinance of the Ministry of Health and Welfare for patient safety in the Image. However, the use of existing and in EMR, equipment within the handwriting input, the individual initial use has a problem. In this study, increasing the stability of the patient and the precise inspection, In order to increase the efficiency and convenience than the real-name system for quality control inspectors of medical equipment, Using the EMR and PACS developed and applied to evaluate the usefulness of automatic enrollment. Enter your information in the EMR, which was developed markers that inspectors use to compare the before and after images PACS satisfaction. Convenience than using traditional, consistency, the entry of the missing were higher as a statistically significant difference. A test strip automatic enrollment programs are developed in this study. You can increase the stability of the patient by checking the image to show the real tester, we expect the quality of care would be improved.

The Current Status and Recommendation of Work Environment Management in Small Scale Industry with less than 5 Workers (경인지역 일부 5인미만 사업장 근로자의 작업환경실태와 관리대책)

  • Kim, Dea Sic;Roh, Youngman;Kim, Hyun Wook;Jeong, Chun Hwa;You, Ki ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.179-189
    • /
    • 2001
  • This study was performed to identify the current status of work environment management and to provide appropriate recommendations for small scale industry with less than 5 workers from September, 2000 to October, 2000 in Seoul city and Gyoung-gi province. The 211 companies were surveyed by checklist included the elements of management of work environment, hazardous chemicals, MSDS, personal protective equipment, and ventilation system. The proportion of metal products manufacturing and printing industries are 25.6 % and 22.3%, respectively. The daily working hours in printing industry is longer than others. The industries that produce potentially hazardous agents, such as noise, dust, metal, organic solvents, radiation and chemical material are pulp, plating, machinery, and printing, respectively. In above industries, only 2.8 % of those recognised and had MSDS. The proportion of companies providing fire extinguishers, safety showers are found to be 13.3 %, 7.1 %, respectively. Only 24.2 % of companies provided personal protective equipment to the workers. The ventilation system was operated in most of companies. But local exhaust ventilation system is provided to 22.3 % of those, also had not been annually inspected. This study showed that the current status of occupational safety and health was not appropriate for workers in small scale industries. It is suggested that annual physical examination have to be performed, MSDS usage must become widespread, and employer and emplyees in small scale industry should be educated for the treatment and storage of hazardous chemicals to improve the occupational safety and health of the working environment. also, regulatory standard has to be applied to local exhaust ventilation system in small scale industry to improve the working condition.

  • PDF

An implementation of portable gamma ray detection platform using Cortex-A8 (Cortex-A8을 이용한 휴대용 감마선 검출 플랫폼 구현)

  • Seo, Jae-Gil;Lee, Yoon-Ho;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.1028-1033
    • /
    • 2013
  • As safety and security systems of shipping logistics are reinforced all over the world, ubiquitous technology-based core technology for safety and security is developing to build the system of logistics security. It is feared that the logistics security system of Korea has a possibility to technically depend on developed countries in the futures. Because the essential skills and equipment to retain security of logistics are not developed. It is urgent to introduce a logistics security system that fully integrates the entire logistics segment in the future. Thus, the necessity of developing the portable radiation detector which can detect gamma-ray nuclide is increasing for reinforcing safety and security systems. In this paper, a research suggests the implementation of portable radiation detector platform using Cortex-A8.

Dose Assessment for Workers in Accidents (사고 대응 작업자 피폭선량 평가)

  • Jun Hyeok Kim;Sun Hong Yoon;Gil Yong Cha;Jin Hyoung Bai
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.265-273
    • /
    • 2023
  • To effectively and safely manage the radiation exposure to nuclear power plant (NPP) workers in accidents, major overseas NPP operators such as the United States, Germany, and France have developed and applied realistic 3D model radiation dose assessment software for workers. Continuous research and development have recently been conducted, such as performing NPP accident management using 3D-VR based on As Low As Reasonably Achievable (ALARA) planning tool. In line with this global trend, it is also required to secure technology to manage radiation exposure of workers in Korea efficiently. Therefore, in this paper, it is described the application method and assessment results of radiation exposure scenarios for workers in response to accidents assessment technology, which is one of the fundamental technologies for constructing a realistic platform to be utilized for radiation exposure prediction, diagnosis, management, and training simulations following accidents. First, the post-accident sampling after the Loss of Coolant Accident(LOCA) was selected as the accident and response scenario, and the assessment area related to this work was established. Subsequently, the structures within the assessment area were modeled using MCNP, and the radiation source of the equipment was inputted. Based on this, the radiation dose distribution in the assessment area was assessed. Afterward, considering the three principles of external radiation protection (time, distance, and shielding) detailed work scenarios were developed by varying the number of workers, the presence or absence of a shield, and the location of the shield. The radiation exposure doses received by workers were compared and analyzed for each scenario, and based on the results, the optimal accident response scenario was derived. The results of this study plan to be utilized as a fundamental technology to ensure the safety of workers through simulations targeting various reactor types and accident response scenarios in the future. Furthermore, it is expected to secure the possibility of developing a data-based ALARA decision support system for predicting radiation exposure dose at NPP sites.

Analysis of efficiency of X-ray equipment for medical service (의료용 X-ray 기기의 성능평가)

  • Kim, Tae-Gon;Kim, Toung-Pyo;Lee, Ho-Sic;Park, Yong-Pil;Cheon, Min-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.426-426
    • /
    • 2009
  • Diagnostic X-ray system is general and basic medical equipment to be used in mostly medical organizations, but being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This paper has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

  • PDF

Design and Development of Signal Transmitting POD for Aircraft Application (항공기용 신호 송출 POD의 설계 및 개발)

  • Kim, Jee-heung;Kwak, Young-kil;Kim, Kichul;Park, Joo-rae
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In this research, we develop an airborne equipment radiating S/C-band signal to a target located at a long distance. RF interface of the equipment comprises band-specific transmitters and an broadband antenna to satisfy EIRP(effective isotropic radiated power) requirements. The equipment is in a shape of a POD like an aircraft fuel tank. The measured weight of the equipment is 119.8 kg, the CG(center of gravity) is 1391.35 mm and the MOI(moment of inertia) are 46.07 ± 0.05(Iyy) kg·㎡, 45.36 ± 0.09(Izz) kg·㎡. All results are found to meet the requirements for aircraft installation. To verify flight safety, EMI(electromagnetic interference) tests (RE102, CE102), environmental tests (high/low temperature operation, altitude), intra-system EMC(electromagnetic compatibility) and HERP(hazards electromagnetic radiation personnel) tests have been conducted and all the test results met the requirements. It is confirmed that the equipment could be mounted on the aircraft by meeting all electrical and mechanical requirements.

Analysis of Regulatory Guidance on Electromagnetic Interference of Equipment for Safety of Nuclear Power Plants (원자력발전소 안전을 위한 전자파장해 검증 규제지침 분석)

  • Park, Jae Yoon;Ah, In Beom;Kim, Jaehyun;Choo, Jaeyul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.74-79
    • /
    • 2022
  • This study analyzes the contents of the second revised Regulatory Guide 1.180 (Revision 2) for electromagnetic compatibility qualification published by the U. S. Nuclear Regulatory Commission by comparing them with those of the previous version. The methods and acceptance criteria of both CE101 and CE102 tests pertaining to conductive emission and RE102 test for radiation emission are observed to have been modified in Revision 2. Furthermore, the revised guide is found to afford flexibility in using alternative methods for electromagnetic interference qualification by allowing the combination of different technical base standards.

A COMPARISON STUDY OF SPACE RADIATION DOSE ANALYSIS PROGRAMS: SPENVIS SECTORING TOOL AND SIGMA II

  • Chae Jongwon
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.347-350
    • /
    • 2004
  • A space radiation analysis has been used to evaluate an ability of electronic equipment boxes or spacecrafts to endure various radiation effects, so it helps design thicknesses of structure and allocate components to meet the radiation requirements. A comparison study of space radiation dose analysis programs SPENVIS Sectoring Tool (SST) and SIGMA II is conducted through some structure cases, simple sphere shell, box and representative satellite configurations. The results and a discussion of comparison will be given. A general comparison will be shown for understanding those programs. The both programs use the same strategy, solid angle sectoring with ray-tracing method to produce an approximate dose at points in representative simple and complex models of spacecraft structures. Also the particle environment data corresponding to mission specification and radiation transport data are used as input data. But there are distinctions between them. The specification of geometry model and its input scheme, the assignment of dose point and the numbers, the prerequisite programs and ways of representing results will be discussed. SST is a web-based interactive program for sectoring analysis of complex geometries. It may be useful for a preliminary dose assessment with user-friendly interfaces and a package approach. SIGMA II is able to obtain from RSICC (Radiation Safety Information Computational Center) as a FOR-TRAN 77 source code. It may be suitable for either parametric preliminary design or detailed final design, e.g. a manned flight or radiation-sensitive component configuration design. It needs some debugs, recompiling and a tedious work to make geometrical quadric surfaces for actual spacecraft configuration, and has poor documentation. It is recommend to vist RSICC homepage and GEANT4/SSAT homepage.

  • PDF