• 제목/요약/키워드: radiation enhancement

검색결과 279건 처리시간 0.034초

Influence of Low Dose Gamma Radiation on the Growth of Maize(Zea mays L.) Varieties (옥수수 생육에 미치는 저선량 감마선 조사효과)

  • Kim, Jae-Sung;Lee, Young-Keun;Park, Hong-Sook;Back, Myung-Hwa;Kim, Dong-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • 제19권4호
    • /
    • pp.328-331
    • /
    • 2000
  • Maize (Zea mays L. cv. kosungjaerae and cv. youngwoljaerae) seeds were irradiated with the dose of $0.5{\sim}20$ Gy by $^{60}Co\;{\gamma}-ray$ radiation to investigate the effect of the low dose ${\gamma}-ray$ radiation on the germination rate, early growth and yield. The low dose radiation was able to improve the germination rate and early growth in maize, but the optimal radiation doses were different depended on kinds of cultivars. High stimulatory effect in early growth of maize was observed in 2 Gy irradiation group of kosungjaerae cultivar and in 12 Gy irradiation group of youngwoljaerae cultivar. The optimal radiation dose for the enhancement of yield and yield components in maize was 8 Gy in kosungjaerae cultivar and $4{\sim}12$ Gy in youngwoljaerae cultivar.

  • PDF

Effect of Low Dose of Gamma Radiation on the Growth of Groundnut (Arachis hypogaea L.) (저선량 감마선이 땅콩 생장에 미치는 효과)

  • 김재성;이은경;백명화;박홍숙;김광호
    • Korean Journal of Environmental Biology
    • /
    • 제17권3호
    • /
    • pp.257-261
    • /
    • 1999
  • Effect of low dose gamma radiation on the growth of groundnut (Arachis hypognea L.) were investigated with respect to germination rate, seedling development and yield. Seeds of “Palpal” cultivar were irradiated with 0.5~20 Gy of ${\gamma}$ radiation in order to determine the hermetic effect of low dose radiation. The germination rate of ${\gamma}$-ray irradiation group was lower than that of the control but the seedling height of groundnut grown from seeds irradiated with low dose ${\gamma}$-ray was slightly higher than that of the control. The number of pod and kernels, and the seed yield increased by 27%, 17% and 19 %, respectively, in the 12.0 Gy irradiation group compared to that in the control group. The 100 seed weight was 87.2 g in the 4.0 Gy irradiation group, which was 11% heavier than 78.3 g in the control group. Low dose radiation showed an enhancement effects on the growth and yield components of groundnut.

  • PDF

A Monte Carlo Study of Dose Enhancement with kilovoltage and megavoltage photons (몬테칼로 기법을 이용한 kV, MV X선에서의 선량증가 효과 비교 평가)

  • Hwang, ChulHwan;Im, In-Chul;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • 제11권2호
    • /
    • pp.87-94
    • /
    • 2017
  • Monte Carlo simulations were used to assess dose enhancement effects for 60-, 90-, 120-, and 150-kV X-rays, and for 6- and 15-MV X-rays. The MCNPX code was used for a computer simulation of the ICRU slab phantom, and gold, gadolinium, and iron oxide (Fe2O3) were employed as dose enhancement agents. In consideration of the buildup region of the incident energy, agent concentrations of 5, 10, 15, and 20 mg/g were inserted on the surface of the phantom at a depth of 5 cm. Based on baseline values obtained in the absence of dose enhancement agents, a quantitative analysis was performed by evaluating depth-dependent changes in the absorbed energy and the dose enhancement factor (DEF). A higher concentration of dose enhancement agents led to a greater dose enhancement effect with iron oxide, gadolinium, and gold in descending order. For kilovoltage (kV) X-rays, as the incident energy was decreased and as the energy became closer to the ionization potential of the atoms in the enhancement agent, the dose enhancement effect increased. In the megavoltage (MV) X-ray range, dose enhancement was higher at 6 MV compared with 15 MV. However, the overall dose enhancements were significantly lower compared to the results obtained with kV X-rays.

Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy (골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구)

  • Kim Woo Chul;Park Won;Kim Heon Jong;Park Seong Young;Cho Young Kap;Loh John J;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • 제16권4호
    • /
    • pp.497-504
    • /
    • 1998
  • Purpose : To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film Materials and Methods : From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 Mu/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum. iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated - very clear (1), clear (2), visible (3), not clear (4), not visible (5). Results : Using an video camera based EPID system. there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image qualify after window level adjustment. Conclusion : The quality of image acquired using an electronic portal imaging device was comparable to that of the port film. When we used the enhance mode or window level adjustment. the image quality of the EPID was superior to that of the port film. EPID may replace the port film.

  • PDF

Enhancement of in vivo Radiosensitization by Combination with Pentoxifylline and Nicotinamide (Pentoxifylline과 Nicotinamide의 병용에 의한 생체내 방사선 감수성 증강 효과)

  • Lee Intae;Cho Moon-June
    • Radiation Oncology Journal
    • /
    • 제9권1호
    • /
    • pp.7-15
    • /
    • 1991
  • Pentoxifylline (PENTO) has been known to improve RBC fluidity, and thus improve the flux of RBC through narrow capillaries. Additionally, PENTO also decreases the $O_2$ affinity of hemoglobin by increasing 2,3-DPG levels, thereby increasing the $O_2$ release from RBC. Nicotinamide (NA) has been reported to decrease the number of acutely hypoxic cells in tumors by temporarily increasing tumor blood flow. Therefore, the purpose of this study was to examine whether the combination of PENTO and NA (PENTO+NA) would reduce the radioresistance of the Fsall murine fibrosarcoma by oxygenating the hypoxic cells. We obsewed a significantly enhanced radiation-induced growth delay of the FSaII tumors by PENTO+NA. Thus the enhancement ratio was between 2.5 and 2.8 in growth delay assay. The $TCD_{50}$ of control tumors was about 57 Gy, but that of PENTO+NA treated tumors was about 32Gy. Thus $TCD_{50}$ was modified by a factor of 1.8. We also observed that PENTO+NA exerted no effect on the radiation-induced skin damage after the legs without bearing tumors were exposed to X-irradiation. In order to clarify radiosensitizing effects of PENTO+ NA, changes in tumor blood flow and intratumor pOf were measured using laser Doppler flowmetry and $O_2$ microelectrode methods. The tumor blood flow significantly increased at 10 min. after injection of PENTO+ NA. Furthermore, we also found that PENTO+ NA significantly increased intratumor $pO_2$ from 8 to 19 mmHg. We concluded that PENTO+MA was far more effective than NA alone or PENTO alone. The increase in the response of tumors in vivo to X-irradiation appeared to be due mainly to an increase in the tumor oxygenation. Further studies using various concentrations of PENTO alone and in combination with NA to obtain better sequencing and maximal radiosensitization are warranted.

  • PDF

The Enhancement of Skin Sparing by Tray Materials for High Energy Photon Beam (고에너지 광자선치료에서 고정판 흡수물질을 이용한 피부보호효과의 향상)

  • Chu, Sung-Sil;Lee, Chang-Geol;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • 제11권2호
    • /
    • pp.449-454
    • /
    • 1993
  • The skin sparing effect associated with high energy x-ray or gamma ray beams may be reduce or lost under certain conditions of treatment. Current trends in using large fields. Shield carrying trays, compensating filters, and isocentric methods of treatment have posed problems of increased skin dose which sometimes become a limiting factor in giving adquate tumor doses. We used the shallow ion chamber to measure the phantom surface dose and the physical treatment variables for Co-60 gamma ray, 4MV and 10 MV x-ray beam. The dependence of percent surface dose on field sizes, atomic number of the shielding tray materials and its distance from the surface for 4, 10MV x-rays and Co-60 gamma ray is qualitatively similar. The use of 2 mm thick tin filter is recommended for situations where a low atomic number tray is introduced into the beam at distances less than 15 cm from the surface and with the large field sized for 4 MV x-ray beam. In case of Co-60 gamma ray, the lead glass tray is suitable for enhancement of skin sparing. Also, the filter distance should be as large as possible to achieve substantial skin sparing.

  • PDF

The Color Enhancement of TV Picture by the Color Measurement of Illumination (광원의 색채 계측에 의한 TV 화상의 색 향상)

  • 이응주;정인갑;박양우;이광춘;하영호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제21권1호
    • /
    • pp.47-58
    • /
    • 1996
  • An object color can be seen differently under the various outer illuminants. However, human visual system has color constnacy that the object color can be seen constantly under the different outer illuminants. When the viewer watches TV under specific that the object color can be seen constantly under the different outer illuminants. When the viewer bathes TV under specific outer illuminants, he perceives distortes color due to the emitting specturm of outer illuminants as well as the radiation of CPT itself. Namely, when the outer illuminants such as fluorescent and incandescent lamps incident on CPT, brightness, saturation, hue, itself. Namely, when the outer iluminants such as fluorescent and incandescent lamps incident on CPT, brightness, saturation, hue, and contrast on color pictures are changend, he perceives distortedcolr fromthe original color. In this paper color enhancement algorithm based on light intensity and outer light decision funtion using RGB sensor was proposed. The implemented TV of proposed algorithm has higher visual quality at the view point of human visual system and more vivid than that ofcoventional color TV.

  • PDF

Enhancement of Soil Flushing Method by Ultrasonic Radiation on Diesel Contaminated Soils (디이젤 오염토 수세시 초음파가 세척률 증가에 미치는 영향에 관한 연구)

  • 김영욱;김지형;이인모
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.401-406
    • /
    • 2000
  • Spilling of petroleum hydrocarbons such as gasoline, motor oils, and diesel fuel from underground storage tanks (USTs) is a major source of contamination to ground water and soils. In response to the need of developing an effective and economical cleanup technique, this study investigates the effectiveness of using sonication to enhance the soil flushing method. The study involves laboratory testing, and the testing was conducted using a specially designed and fabricated device to determine the effect of sonication on contaminant removal. The sonication was applied at 20 kHz frequency under different power levels. Test soil was Joomoonjin Sand, and diesel fuel was used as a contaminant of soil flushing test. The results of the investigation show that sonication enhanced the contaminant removal from soils significantly, and the degree of enhancement varied with power levels of sonication. Based on the results of the study, it is concluded that the flushing method with sonication has a great potential to become an effective method for removing petroleum hydrocarbons from the contaminated ground.

  • PDF

Color Enhancement of TV Picture Using Optical Sensor (광 센서를 이용한 TV 화상의 색 향상)

  • 이응주;김경만;박양우;정인갑;하영호
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 한국방송공학회 1995년도 학술대회
    • /
    • pp.69-74
    • /
    • 1995
  • An object color can be seen differently under the various outer illuminants. However, human visual system has color constancy that the object color can be seen constantly under the different outer illuminants. When the viewer watches TV under specific outer illuminants, he perceives distorted color due to the emitting spectrum of outer illuminants as well as the radiation of CPT itself. Namely, when the outer illuminants such as fluorescent and incandescent lamps incident on CPT, brightness, saturation, hue, and contrast on color pictures are changed, he perceives distorted color from the original color. In this paper color enhancement algorithm based on light intensity and outer light decision function using RGB sensor was proposed. The implemented TV of proposed algorithm has higher visual quality at the view point of human visual system and more vivid than that of conventional color TV.

The Bandwidth Enhancement of an Aperture Coupled Microstrip Patch Antenna Using Variation of an Aperture Width (개구면 폭 변화를 이용한 개구면 결합 마이크로스트립 패치 안테나의 대역폭 확장)

  • Kim, Jae-Hyun;Koo, Hwan-Mo;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제52권1호
    • /
    • pp.48-58
    • /
    • 2015
  • The bandwidth enhancement of an aperture coupled microstrip patch antenna(ACMPA) with a high permittivity feed substrate suitable for the integration with MMIC is investigated using variation of an aperture width. As an aperture width increases, the 10 dB return loss bandwidth increases due to the increase of the mutual resonance region between a patch resonance and an aperture resonance. The bandwidth of an ACMPA with extended aperture width is increased up to 35.3 % from 20.8 % of the ACMPA with an aperture of a typical aspect ratio 10:1. The degradation of the radiation characteristics of an ACMPA due to the increase of an aperture width is very small.