• Title/Summary/Keyword: radiation enhancement

Search Result 279, Processing Time 0.023 seconds

Characterization of Physical Processes and Secondary Particle Generation in Radiation Dose Enhancement for Megavoltage X-rays (MV X선의 방사선 선량 증강 현상에서 물리적 특성과 이차입자의 발생)

  • Hwang, Chulhwan;Kim, JungHoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.791-799
    • /
    • 2019
  • We evaluated the physical properties that occur to dose enhancement and changes from secondary particle production resulting from the interaction between enhancement material. Geant4 was used to perform a Monte Carlo simulation, and the medical internal radiation dose (MIRD) head phantom were employed. X-rays of 4, 6, 10, 15, 18, and 25 MV were used. Aurum (Au) and gadolinium (Gd) were applied within the tumor volume at 10, 20, and 30 mg/g, and an experiment using soft tissue exclusively was concomitantly performed for comparison. Also, particle fluence and initial kinetic energy of secondary particle of interaction were measured to calculate equivalent doses using the radiation weight factor. The properties of physical interaction by the radiation enhancement material showed the great increased in photoelectric effect as compared to the compton scattering and pair production, occurred with the highest, in aurum and gadolinium it is shown in common. The photonuclear effect frequency increased as the energy increased, thereby increasing secondary particle production, including alpha particles, protons, and neutrons. During dose enhancement using aurum, a maximum 424.25-fold increase in the equivalent dose due to neutrons was observed. This study was Monte Carlo simulation corresponds to the physical process of energy transmission in dose enhancement. Its results may be used as a basis for future in vivo and in vitro experiments aiming to improve effects of dose enhancement.

Analysis of Radiation Dose Enhancement for Spread Out Bragg-peak of Proton (확산된 피크의 양성자에서 선량 증강 현상에 대한 분석)

  • Hwang, Chulhwan;Kim, JungHoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.253-260
    • /
    • 2019
  • Radiation dose enhancement is a method of increasing the cross section of interaction, thus increasing the deposited dose. This can contribute to linear energy transfer, LET and relative biological effectiveness, RBE. Previous studies on dose enhancement have been mainly focused on X, ${\gamma}-rays$, but in this study, the dose enhancement was analyzed for proton using Monte Carlo simulation using MCNP6. Based on the mathematical modeling method, energy spectrum and relative intensity of spread out Bragg-peak were calculated, and evaluated dose enhancement factor and dose distribution of dose enhancement material, such as aurum and gadolinium. Dose enhancement factor of 1.085-1.120 folds in aurum, 1.047-1.091 folds in gadolinium was shown. In addition, it showed a decrease of 95% modulation range and practical range. This may lead to an uncertain dose in the tumor tissue as well as dose enhancement. Therefore, it is necessary to make appropriate corrections for spread out Bragg-peak and practical range from mass stopping power. It is expected that Monte Carlo simulation for dose enhancement will be used as basic data for in-vivo and in-vitro experiments.

Automated radiation field edge detection in portal image using optimal threshold value (최적 문턱치 설정을 이용한 포탈영상에서의 자동 에지탐지 기법에 관한 연구)

  • 허수진
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.337-344
    • /
    • 1995
  • Because of the high energy of the treatment beam, contrast of portal films is very poor. Many image processing techniques have been applied to the portal images but a significant drawback is the loss of definition on the edges of the treatment field. Analysis of this problem shows that it may be remedied by separating the treatment field from the background prior to enhancement and uslng only the pixels within the field boundary in the enhancement procedure. A new edge extraction algorithm for accurate extraction of the radiation field boundary from portal Images has been developed for contrast enhancement of portal images. In this paper, portal image segmentation algorithm based on Sobel filtration, labelling processes and morphological thinning has been presented. This algorithm could automatically search the optimal threshold value which is sensitive to the variation of the type and quality of portal images.

  • PDF

A Study on Enhancement of UV Disinfection System Performance by the Vortex Generator (와동 발생기를 이용한 자외선 살균 시스템 성능 향상에 관한 연구)

  • Kim, Bong-Hwan;Ahn, Kook-Chan;Kim, Dong-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.1 s.79
    • /
    • pp.24-29
    • /
    • 2007
  • The effectiveness of a UV(ultra violet) disinfection system depends on the characteristics of the waste water, flow conditions, the intensity of UV radiation, the amount of time the microorganisms are exposed to the radiation, and the reactor configuration. The wast water flow conditions are important factors in the design of UV disinfection system from the point of enhancement view of UV disinfection. The turbulent energy intensity in the wake by the vortex shedding are effective for UV radiation. Therewith the effectiveness of vortex generator is considered as a enhancement of UV disinfection. The experimental results presented give important evidences and explain that it is possible to predict UV disinfection performance based on flow experiments. An experimental investigation of two types of the vortex generator is presented. The qualitative and quantitative evaluations of the wake are made by flow visualization using smoke wire method and the measurement of vortex frequencies in the wind tunnel. From the experiment, following results were obtained that the delta wing type vortex generator is more effective than circular type because of the higher vortex frequencies and the smaller drag.

Antenna Radiation Efficiency of the Korean NDGPS Based on Radiation Power Measurements

  • Kim, Young-Wan
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.2
    • /
    • pp.97-102
    • /
    • 2012
  • The differential global positioning system (DGPS) transmits a GPS enhancement signal using a top-loaded monopole antenna in the medium frequency range. The top-loaded antenna in the medium frequency band can attain a radiation efficiency on the order of 10%. The antenna ground plane characteristics affect the antenna radiation efficiency. To improve the radiation efficiency, it is necessary to install the antenna on a ground plane with large enough physical dimensions and good conductivity. The antenna radiation efficiency is a primary factor in determining the DGPS service area. The service area of the DGPS using a medium frequency band is dominantly affected by the antenna radiation efficiency. To determine antenna radiation efficiencies accurately, the antenna radiation efficiencies of DGPS are deduced from the propagation power in this paper. Based on the deduced antenna radiation efficiencies, the service area for the Korean nationwide-DGPS is analyzed and evaluated.

The Enhancement of Radiosensitivity by Celecoxib, Selective Cyclooxygenase-2 Inhibitor, on Human Cancer Cells Expressing Differential Levels of Cyclooxygenase-2 (선택적 Cyclooxygenase-2 억제제인 Celecoxib가 상이한 Cyclooxygenase-2 발현량을 가진 인간 암세포주들에 대하여 유도하는 방사선 감수성 증진 작용)

  • Pyo Hongryull;Shin You Keun;Kim Hyun Seok;Seong Jinsil;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.216-221
    • /
    • 2003
  • Purpose: To investigate the modulation of radiosensitivity by celecoxib, a selective cyclooxygenase-2 (COX-2) inhibitor, on cancer cells over- and under-expressing COX-2. Materials and Methods: A clonogenic radiation survival analysis was performed on A549 human lung and MCF-7 human breast cancer cell lines incubated in both 1 and $10\%$ fetal bovine serum (FBS) containing media. The apoptosis in both cell lines was measured after treatment with radiation and/or celecoxib. Results: Celecoxib enhanced the radiation sensitivity of the A549 cells in the medium containing the $10\%$ FBS, with radiation enhancement ratios of 1.58 and 1.81 respectively, at surviving fractions of 0.1, with $30\muM\;and\;50\muM$ celecoxib. This enhanced radiosensitivity disappeared in the medium containing the $1\%$ FBS. Celecoxib did not change the radiation sensitivity of the MCF-7 cells in either media. The induction of apoptosis by celecoxib and radiation was not synergistic in either cell line. Conclwsion: Celecoxib, a selective COX-2 inhibitor, preferentially enhanced the effect of radiation on COX-2 over-expressing cancer cells compared to the cells with a low expression, and this effect disappeared on incubation of the cells during drug treatment in the medium with suboptimal serum concentration. Apoptosis did not appear to be the underlying mechanism of this radiation enhancement effect due to celecoxib on the A549 cells. These findings suggest radiosensitization by a selective COX-2 inhibitor is COX-2 dependent.

The Modulation of Radiosensitivity by Combined Treatment of Selective COX-2 Inhibitor, NS 398 and EGF Receptor Blocker AG 1478 in HeLa Cell Line (선택적 COX-2 억제제 NS 398과 EGF 수용체 차단제 AG 1478의 복합투여가 HeLa 세포주의 방사선 감수성에 미치는 영향)

  • Youn Seon Min;Oh Young Kee;Kim Joo Heon;Park Mi Ja;Seong In Ock;Kang Kimun;Chai Gyuyong
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.51-60
    • /
    • 2005
  • Purpose : Selective inhibition of multiple molecular targets may improve the antitumor activity of radiation. Two specific inhibitors of selective cyclooxygenase-2 (COX-2) and epidermal growth factor receptor (EGFR) were combined with radiation on the HeLa cell line. To investigate cooperative mechanism with selective COX-2 inhibitor and EGFR blocker, in vitro experiments were done. Materials and Methods : Antitumor effect was obtained by growth inhibition and apoptosis analysis by annexin V-Flous method. Radiation modulation effects were determined by the clonogenic cell survival assay. Surviving fractions at 2 Gy ($SF_2$) and dose enhancement ratio at a surviving fraction of 0.25 were evaluated. To investigate the mechanism of the modulation of radiosensitivity, the cell cycle analyses were done by flow cytometry. The bcl-2 and bax expressions were analyzed by western blot. Results : A cooperative effect were observed on the apoptosis of the HeLa ceil line when combination of the two drugs, AG 1478 and NS 398 with radiation at the lowest doses, apoptosis of $22.70\%$ compare with combination of the one drug with radiation, apoptosis of $8.49\%$. In cell cycle analysis, accumulation of cell on $G_0/G_l$ phase and decrement of S phase fraction was observed from 24 hours to 72 hours after treatment with radiation, AG 1478 and NS 398. The combination of NS 398 and AG 1478 enhanced radiosensitivity on a concentration-dependent manner in HeLa cells with dose enhancement ratios of 3.00 and $SF_2$ of 0.12 but the combination of one drug with radiation was not enhanced radlosensitivity with dose enhancement ratios of 1.12 and SF2 of 0.68 (p=0.005). The expression levels of bcl-2 and bax were reduced when combined with AG 1478 and NS 398. Conclusion : Our results indicate that the selective COX-2 inhibitor and EGFR blocker combined with radiation have potential additive or cooperative effects on radiation treatment and may act through various mechanisms including direct inhibition of tumor cell proliferation, suppression of tumor cell cycle progression and inhibition of anti-apoptotic proteins.

Synthesis and Biological Evaluation of Novel IM3829 (4-(2-Cyclohexylethoxy)aniline) Derivatives as Potent Radiosensitizers

  • Ahn, Jiyeon;Nam, Ky-Youb;Lee, Sae-Lo-Oom;Ryu, Hwani;Choi, Hyun Kyung;Song, Jie-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3623-3626
    • /
    • 2014
  • Nuclear factor-erythroid 2-related factor 2 (Nrf2) regulates the expression of over 200 genes of antioxidant and phase II drug-metabolizing enzymes, and is highly expressed in non-small cell lung cancer (NSCLC). Nine derivatives of 4-(2-cyclohexylethoxy)aniline were designed. Our previous study demonstrated that IM3829 increases radiosensitivity of several lung cancer cells in vitro and in vivo. Here, biological effects of IM3829 derivatives (2a-2i) were evaluated. Compound 2g derivative effectively inhibits mRNA and protein expression of Nrf2 and HO-1. In addition, we observed over two fold enhancement in IR-induced cell death, from $2.90{\pm}0.22$ to $6.02{\pm}0.87$, in H1299 cancer cell-line. Among the nine derivatives, compound 2g derivative exhibited the highest enhancement of radiosensitizing effect via inhibition of Nrf2 activity.

Simulating the impact of iodine as a contrast substance to enhance radiation to the tumor in a brain x-rayphototherapy

  • M. Orabi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1671-1676
    • /
    • 2023
  • The influence of adding iodine as a contrast substance to elevate radiation in a tumor is studied using simulation techniques of Monte-Carlo. The study is carried on a brain cancer by adopting an unsophisticated head phantom. The ionizing radiation source is an external beam of x-rays with energy range of a few tens of keV. The expected radiation dose increment due to adding the iodine is investigated by comparing the radiation in the tumor after and before adding the iodine and calculating the ratio between the two doses. Several concentrations of the contrast substance are used to quantify its impact. The change of the dose increment with the source energy is also examined. It is found that the radiation elevation in the tumor tends to saturate with increasing the iodine concentration, and for the studied domain of energies (30 keV-100 keV), the radiation dose enhancement factors (RDEF) for the different iodine concentrations (1%-9%) show peaked curves, with the peak occurring between 60 keV and 70 keV. For the highest concentration studied, 9%, the peak value is almost 7.