• Title/Summary/Keyword: radiation detector

검색결과 842건 처리시간 0.029초

Proposing a gamma radiation based intelligent system for simultaneous analyzing and detecting type and amount of petroleum by-products

  • Roshani, Mohammadmehdi;Phan, Giang;Faraj, Rezhna Hassan;Phan, Nhut-Huan;Roshani, Gholam Hossein;Nazemi, Behrooz;Corniani, Enrico;Nazemi, Ehsan
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1277-1283
    • /
    • 2021
  • It is important for operators of poly-pipelines in petroleum industry to continuously monitor characteristics of transferred fluid such as its type and amount. To achieve this aim, in this study a dual energy gamma attenuation technique in combination with artificial neural network (ANN) is proposed to simultaneously determine type and amount of four different petroleum by-products. The detection system is composed of a dual energy gamma source, including americium-241 and barium-133 radioisotopes, and one 2.54 cm × 2.54 cm sodium iodide detector for recording the transmitted photons. Two signals recorded in transmission detector, namely the counts under photo peak of Americium-241 with energy of 59.5 keV and the counts under photo peak of Barium-133 with energy of 356 keV, were applied to the ANN as the two inputs and volume percentages of petroleum by-products were assigned as the outputs.

Measurement of the applicability of various experimental materials in a medically relevant reactor neutron source part two: Study of H3BO3 and B-DTPA under neutron irradiation

  • Ezddin Hutli;Peter Zagyvai
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2419-2431
    • /
    • 2023
  • Experiments related to Boron Neutron Capture Therapy (BNCT) accomplished at the Institute of Nuclear Techniques (INT), Budapest University of Technology and Economics (TUB) are presented. Relevant investigations are required before designing BNCT for vivo applications. Samples of relevant boron compounds (H3BO3, BDTPA) usually employed in BNCT were investigated with neutron beam. Channel #5 in the research reactor (100 kW) of INT-TUB provides the neutron beam. Boron samples are mounted on a carrier for neutron irradiation. The particle attenuation of several carrier materials was investigated, and the one with the lowest attenuation was selected. The effects of boron compound type, mass, and compound phase state were also investigated. To detect the emitted charged particles, a traditional ZnS(Ag) detector was employed. The neutron beam's interaction with the detector-detecting layer is investigated. Graphite (as a moderator) was employed to change the neutron beam's characteristics. The fast neutron beam was also thermalized by placing a portable fast neutron source in a paraffin container and irradiating the H3BO3. The obtained results suggest that the direct measurement approach appears to be insufficiently sensitive for determining the radiation dose committed by the Alpha particles from the 10B (n,α) reaction. As a result, a new approach must be used.

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.

Mechanical Check용 Spherical Device의 제작 및 특성 평가 (Practicability Assessment of Spherical Type Mechanical Check Device (SMCD))

  • 이병구;김건오;권영호
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.55-62
    • /
    • 2007
  • 목 적: PACS의 도입에 발맞추어 시작된 디지털 의료영상은 현재 방사선 진단 및 치료 영역에서 일반화되었으며 특히 진단 영역에서는 눈부신 발전을 거듭하고 있다. 치료영역에서의 디지털 영상 구현은 상대적으로 느린 성장과정을 거쳐 오늘에 이르고 있다. 본 논문은 이러한 아날로그에서 디지털로 변화하는 흐름을 인식하여 정도관리(Quality Assurance) 업무 중 기계적 점검(Mechanical check) 부분을 디지털 영상 기반 업무로 대체하여 수행하고, 기존의 육면체 또는 사각형틀의 개념을 탈피한 구형(球形)의 Spherical type mechanical check device (SMCD)를 고안하여 그 실용성을 실험하였다. 대상 및 방법: 선원에서 영상 detecter 간의 거리가 항상 일정하고, SMCD의 중심까지 거리가 일정하다면 어느 방향에서 방사선으로 SMCD를 조사하더라도 그 크기는 항상 일정하게 영상으로 표현 될 것이다. 이를 위해 Polyester P.E 재질의 정확한 반구(半球) 2개를 자체 제작하여 그것을 합쳤을 때 정원(正圓)의 구(球)가 되도록 하였다. 결 과: SMCD를 이용하여 방사선조사면과 광조사면의 일치도, 방사선조사면 크기의 정확도($5{\times}5$, $10{\times}10$, $15{\times}15cm^2$), Collimator field 크기의 정확도($5{\times}5$, $10{\times}10$, $15{\times}15cm^2$), Gantry rotation isocenter check, Collimator rotation isocenter check, Room laser accuracy check, Collimator rotation angle check와 Couch rotation angle check 등 기존의 기계적 점검을 디지털 영상을 이용하여 실행할 수 있었다. 결 론: 기존의 Flat 또는 정육면체 형태의 기계적 점검 장치로는 쉽게 하기 힘든 non-coplanar field에 적용되는 Gantry와 Couch가 동시에 rotation 되었을 때 그 isocenter의 일치도를 실시간으로 확인할 수 있었다.

  • PDF

Prediction of Midline Dose from Entrance and Exit Dose Using OSLD Measurements for Total Body Irradiation

  • Choi, Chang Heon;Park, Jong Min;Park, So-Yeon;Chun, Minsoo;Han, Ji Hye;Cho, Jin Dong;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.77-82
    • /
    • 2017
  • Background: This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). Materials and Methods: For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. Results and Discussion: The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. Conclusion: The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

Exposure Index변화에 따른 Image Quality와 Effective dose에 대한 연구: a Monte Carlo Simulation Study (Research on Image Quality and Effective dose by Exposure Index Variation)

  • 김현수;정재호;이종웅
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.63-69
    • /
    • 2013
  • 평판 검출기(flat-panel detector)는 필름-스크린 시스템과 비교하여 넓은 범위의 노출지수(dynamic range)를 갖게 된다. 평판 검출기를 대상으로 임상에서 일반적으로 사용하고 있는 Abdomen supine 노출 조건인 81kV에 20mAs를 기준으로 전신형 팬텀 whole body human phantom PBU-50 (Kyoto, kagaku, Japan)을 모의 환자로 화질평가와 피폭선량측면에서 비교 연구하였다. PSNR값이 30dB이상으로 판독 가능한 영상의 kV변화에 따른 DAP값은 약 19.6배 차이를 나타냈다. 또한 kV변화에 따른 유효선량을 ICRP 103을 기준으로 비교한 결과 방사선에 의한 확률적 영향이 증가함을 알 수 있었다. 방사선검사자의 지속적인 교육 및 지도를 통한 우리나라에 맞는 디지털 방사선 Technical chart를 마련하여 양질의 영상과 환자피폭선량에 대한 기준 선량을 마련해야 할 것이다.

다중 이용 건물 또는 지하 실내 공간의 용도에 따른 라돈 오염도 비교와 지하 공간의 시간대별 라돈 농도 변화 (Evaluation of Radon Levels in Various Public-acess Buildings or Underground Facilities, and Their Temporal Variation in Underground Facilities)

  • 최임조;신승호;조완근
    • Environmental Analysis Health and Toxicology
    • /
    • 제24권3호
    • /
    • pp.203-211
    • /
    • 2009
  • A lesser degree of research is available with respect to indoor radon characteristics associated with occupants' exposure. The present study evaluated the radon levels in several public-access buildings or underground facilities, and their temporal variation in underground facilities. Radon measurements were conducted in 2005 and 2006, utilizing a continuous radon detector. A solid alpha detector (RAD7) was utilized to measure indoor radon levels. The mean radon concentrations obtained from the building or facilities were in a descending order: platforms of Daegu subway line 2, 2005 (32 $Bq/m^3$), hot-air bathroom (14 $Bq/m^3$), basement of office building (14 $Bq/m^3$), underground parking garage (14 $Bq/m^3$), underground shop (12 $Bq/m^3$), nursery (10 $Bq/m^3$), platforms of Daegu subway line 2, 2006 (9.0 $Bq/m^3$), platforms of Daegu subway line 1, 2006 (8.9 $Bq/m^3$), supermarket (7.9 $Bq/m^3$), hospital (7.3 $Bq/m^3$), and second-floor of office building (5.7 $Bq/m^3$). In general, underground-level facilities exhibited higher radon levels as compared with ground-level facilities. It was suggested that ventilation is an important parameter regarding the indoor levels of a subway. There was a decreasing or increasing trend in hourly-radon levels in a subway, whereas no trend were observed in a basement of office building. In addition, the radon levels in the subway lines 1 and 2 varied according to the platforms. The radon levels in the present study were much lower than those of previous studies. The average annual effective dose (AED) of radiation from indoor radon exposure was estimated to be between 0.043 and 0.242 mSv/yr, depending on facility types. These AEDs were substantially lower than the worldwide average AED (2.4 mSv/yr).

X-ray 반응 특성 개선을 위한 Hybrid형 디지털 방사선 검출기의 구조 설계 (Structural Design of Digital Radiography Detector using Hybrid Method for the Improvement of Response Property by X-ray)

  • 김교태;한무재;김진선;허예지;오경민;박지군;남상희
    • 한국방사선학회논문지
    • /
    • 제9권6호
    • /
    • pp.363-367
    • /
    • 2015
  • 디지털 방사선촬영 기술은 영상 정보를 획득하는 원리에 따라 광도전체를 이용하는 직접 방식과 형광체를 이용하는 간접 방식으로 구분되지만, 모두 다양한 장단점을 내포하고 있다. 이에 본 연구에서는 X-ray 민감도를 개선하고자 형광체 및 광도전체를 병용한 Hybrid형 검출기의 구조에 대한 기초 연구를 수행하였다. 실험 결과, 조사 시간을 30 ms로 고정하고 관전압을 변화할 경우 전체적으로 직접 방식의 구조에서 우수한 민감도가 나타났으나, 조사 시간이 50 ms 이상에서는 Hybrid 구조의 경우가 더 우수한 것으로 나타났다. 이는 임상에서 다양한 검사를 수행할 경우에 일반적으로 50 ms 이상의 조사시간을 이용한다는 점에서 충분한 연구적 가치를 가질 것으로 사료된다.

핵의학 적용을 위한 광섬유 기반의 알파/베타 검출기의 제작 및 특성분석 (Fabrication and Characterization of a Fiber-Optic Alpha/Beta Detector for Nuclear Medicine Application)

  • 홍승한;유욱재;신상훈;서정기;한기택;전다영;조승현;이봉수
    • 센서학회지
    • /
    • 제21권5호
    • /
    • pp.367-373
    • /
    • 2012
  • We fabricated a fiber-optic alpha/beta detector, which is composed of a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer, to obtain the energy spectra of radioactive isotopes. As inorganic scintillators of a sensing probe, a ZnS(Ag) film was coupled with a $CaF_2$(Eu) crystal for alpha and beta spectroscopy. In this study, $^{210}Po$ and $^{90}Sr$ were used as alpha and beta sources, respectively, and we measured the radiation energy spectra using a fiber-optic alpha/beta detector to identify alpha and beta emitting radionuclides for nuclear medicine application. Also, the variations of energy spectrum were obtained according to the length of plastic optical fiber.

3차원 레이저 각인으로 블록형 섬광체의 픽셀형화를 통한 민감도 향상 검출기 개발 (Development of Sensitivity-Enhanced Detector using Pixelization of Block Scintillator with 3D Laser Engraving)

  • 이승재;백철하
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.313-318
    • /
    • 2019
  • 민감도 향상을 위해 블록형 섬광체를 사용한 검출기를 개발하였다. 픽셀형 섬광체는 섬광체에서 발생된 빛을 최대한 광센서로 이동시키기 위해 픽셀 사이에 반사체가 위치하며, 반사체 부분으로 민감도 손실이 발생한다. 민감도를 향상시키고 픽셀형 섬광체의 특징을 가지게 하기 위해 블록형 섬광체를 레이저 각인을 통해 픽셀 형태의 섬광체로 가공하였다. 본 섬광체를 위치민감형 광전증배관과 결합하여 평면 영상을 획득하였고, 각 픽셀별 에너지 스펙트럼과, 에너지 분해능을 측정하였으며, GATE 시뮬레이션을 통해 블록형 섬광체와 픽셀 섬광체의 민감도 분석을 수행하였다. 측정된 전체 에너지 분해능은 20.7%를 보였으며, 민감도는 픽셀 섬광체에 비해 18.5% 높은 결과를 나타내었다. 본 검출기를 감마카메라 및 양전자방출단층촬영기기 등의 영상화 기기에 활용할 경우 높은 민감도 향상을 통해 촬영시간의 단축 및 적은 방사선원 사용으로 환자의 피폭선량 감소를 이룰 수 있을 것이다.