• Title/Summary/Keyword: radiation cooling

Search Result 387, Processing Time 0.025 seconds

Improving the power of PV module by a surface cooling system (표면냉각을 통한 PV 모듈의 출력 향상에 관한 연구)

  • Kim, Dae-Hyun;Kim, Dong-Jun
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.88-93
    • /
    • 2009
  • This study was conducted to improve the power of PV module using a surface cooling system One of the unique characteristics of PV module is power drop as a module surface temperature increases due to the characteristics of crystalline silicon used in a solar cell. To overcome the output power reduction by temperature effect, module surface cooling using water circulation was performed. By cooling effect, module surface temperature drops maximally $20.3^{\circ}C$ predicting more than 10% power enhancement. Maximum deviation of voltage and current between a control and cooled module differed by 5.1 V and O.9A respectively. The maximum power enhancement by cooling system was 12.4% compared with a control module. In addition, cooling system can wash the module surface by water circulation so that extra power up of PV module can be achieved by removing particles on the surface which interfere solar radiation on the cells. Cooling system, besides, can reduce the maintenance cost and prevent accidents as a safety precaution while cleaning works. This system can be applied to the existing photovoltaic power generation facilities without any difficulties as well.

The Study about the Performance-Analysis of a Automotive Engine Cooling System (엔진 냉각시스템 성능해석에 관한 연구)

  • Shin, Chang-Hoon;Lee, Seung-Hee;Park, Warn-Gyu;Jang, Gi-Lyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.39-48
    • /
    • 2006
  • An engine cooling system affects overall performances of an engine which has been recently requested higher power in more confined engine room. The design of efficient cooling system demands a great effort to effectively correlate with each components, such as water jacket, radiator, coolant pump, cooling fan, etc. Thus, the aim of this study is to provide the design tool of the cooling system in the early design stage by enabling for the designer to accurately predict the engine cooling performances. This user-friendly design tool has various ways to assemble each components and control the running condition with related database. The present design tool was simulated and compared with experimental data. As a result, the inlet and outlet temperature of the radiator agree very well with experiments. It was concluded that the present design tool could be effectively used for the design of the engine cooling system.

Improving the power of PV module by a surface cooling system (표면냉각시스템을 이용한 PV 모듈의 출력 향상)

  • Lee, Jong-Hwan;Lee, Jae-Ung;Kim, Dong-Jun;Kim, Dae-Hyun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.309-313
    • /
    • 2009
  • This study was conducted to improve the power of PV module using a surface cooling system. One of the unique characteristics of PV module is power drop as a module surface temperature increases due to the characteristics of crystalline silicon used in a solar cell. To overcome the output power reduction by temperature effect, module surface cooling using water circulation was performed. By cooling effect, module surface temperature drops maximally $20.3^{\circ}C$ predicting more than 10% power enhancement. Maximum deviation of voltage and current between a control and cooled module differed by 5.1V and 0.9A respectively. The maximum power enhancement by cooling system was 12.4% compared with a control module. In addition, cooling system can wash the module surface by water circulation so that extra power up of PV module can be achieved by removing particles on the surface which interfere solar radiation on the cells. Cooling system, besides, can reduce the maintenance cost and prevent accidents as a safety precaution while cleaning works. This system can be applied to the existing photovoltaic power generation facilities without any difficulties as well.

  • PDF

A Development of Counter Flow Type of Cooling System for Effective Panel Cooling (효과적인 패널 냉각을 위한 대향류형 냉각장치의 개발)

  • Lee, Joong-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.802-807
    • /
    • 2010
  • The high efficient and cooling system is very important to the control panels of electrical distributors, and Industrial automated system including computer. Also, it can be used widely in various industrial systems such as industrial robots, numerically controlled machining center, and so on. The cooling method which flowing gasses were forced to circulate by compulsion was adapted in this study. then development of counter flow type of cooling system for effective panel cooling. In the present study, fin assembly was developed for this cooling system. As results, the developed system has the improvements of cooling performances and radiant heat ratio. Its increasing of airflow mass is about 20%, and radiation rate of heating is twice or more as high as the conventional system.

Hybrid Air-Conditioner Using Both Radiation and Convection (복사-대류 겸용 하이브리드 냉방기)

  • Byun, Ho-Won;Oh, Wang-Kyu;Kim, Nae-Hyun;Choi, Byung-Nam;Lee, Sang-Yeup;Han, Sung-Pil
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.330-333
    • /
    • 2008
  • The hybrid air-conditioner, where air is cooled both by convection and radiation, is developed. The indoor unit of the air-conditioner consists of radiation panel and dehumidification coil, where refrigeration R-134a is supplied by independent refrigeration cycles. Optimum refrigerant charge was 750g for both cycles. Optimum evaporation pressure was 3.7 bar for the radiation panel cycle and 3.9 bar for the dehumidification cycle. The cooling capacity of the radiation panel was 1.01 kW and that of the dehumidification coil was 0.94kW, which yielded COP of 3.3.

  • PDF

AUTOMOBILE UNDERHOOD THERMAL AND AIR FLOW SIMULATION USING CFD (전산유체역학을 이용한 자동차 엔진룸의 열 및 유동장 해석)

  • Oh, K.T.;Kim, J.H.;Lee, S.W.;Kim, Y.S.;Ha, J.W.;Kang, W.K.
    • Journal of computational fluids engineering
    • /
    • v.12 no.1
    • /
    • pp.22-27
    • /
    • 2007
  • Automobile underhood thermal and airflow simulation h α s been performed by using a commercial CFD program, FLUENT. To implement the radiation heat transfer effect to the underhood thermal and flow field, Discrete Ordinates Method(DOM) was used. The cooling fan was modeled by using the Multiple Reference Frame(MRF) technique. For the implementation of the heat exchangers, such as radiator and condenser, which are located in the front side of vehicle, the effectiveness-NTU model was used. The pressure drop throughout the heat exchangers was modeled as Porous media. For the validation of the current computational method, the coolant temperature at the inlet port of the radiator was compared with experimental data, and less than 3% error was observed. Finally, the composed model was used for the cooling fan spec determination process in the development of a new vehicle, and the results showed that the current CFD method could be successfully applied to the vehicle development process.

Parameterization for Longwave Scattering Properties of Ice Clouds with Various Habits and Size Distribution for Use in Atmospheric Models

  • Jee, Joon-Bum;Lee, Kyu-Tae
    • Atmosphere
    • /
    • v.23 no.1
    • /
    • pp.39-45
    • /
    • 2013
  • A parameterization for the scattering of longwave radiation by ice clouds has been developed based on spectral scattering property calculations with shapes and sizes of ice crystals. For this parameterization, the size distribution data by Fu (1996) and by Michell and Arnott (1994) are used. The shapes of ice crystal considered in this study are plate, solid column, hollow column, bullet-rosette, droxtal, aggregate, and spheroid. The properties of longwave scattering by ice crystals are presented as a function of the extinction coefficient, single-scattering albedo, and asymmetry factor. The heating rate and flux by the radiative parameterization model are calculated for wide range of ice crystal sizes, shapes, and optical thickness. The results are compared with the calculated results using a six-stream discrete ordinate scattering algorithm and Chou's method. The new method (with various habits and size distributions) provides a good simulation of the scattering properties and cooling rate in optically thin clouds (optical thickness < 5). Depending on the inclusion of scattering by ice clouds, the errors in the calculation of the cooling rates are significantly different.

Thermal performance of solar cooling and hot water for the demonstration system (태양열 실증 시스템의 냉방 및 급탕 일일 열성능)

  • Lee, Ho;Kim, Sang-Jin;Joo, Hong-Jin;Kwak, Hee-Youl
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.564-569
    • /
    • 2007
  • This study describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about 350㎡ was heated and cooled with the solar system. The system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, subsidiary tank, absorption chiller, chiller storage tank, and cooling tower. The results of the experimental study indicated that the total solar energy gain as daily performance on a sunny day (August 25, 2007) with total daily radiation of $606\;W/m^2$ was 671 kWh, the collecting efficiency of 55%. In the case of supplies to heat source more than $83^{\circ}C$, cooling time operated by solar was driven 8.8 hours, cooling energy generated by solar system was 179 kWh and the solar cooling fraction was 79.2%, and hot water supplied with surplus heat source by the solar system was 201 kWh.

  • PDF

An Experimental Study on the Cooling Characteristics of an Infrared Detector Cryochamber (적외선 센서용 극저온 용기의 냉각특성에 관한 실험적 연구)

  • Kang Byung Ha;Lee Jung Hoon;Kim Ho-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.889-894
    • /
    • 2004
  • Infrared (IR) detectors are widely used for many applications, such as temperature measurement, intruder and fire detection, robotics and industrial equipment, thermoelstic stress analysis, medical diagnostics, and chemical analysis. Quantum detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal analysis of cryochamber includes the conduction heat transfer through a cold well, the gases conduction and gas outgassing, as well as radiation heat transfer, The transient cooling characteristics of an infrared detector cryochamber are investigated experimentally in the present study. The transient cooling load increases as the gas pressure is increased. Gas pressure becomes significant as the cooling process proceeds. Cool down time is also increased as the gas pressure is increased. It is also found that natural convection effects on cool down time become significant when the gas pressure is increased.

Analysis of Heating System for PDP Panel Using $RADCAD^{TM}$ ($RADCAD^{TM}$를 이용한 PDP용 Pane 1 가열 시스템 해석)

  • Kim, Ook-Joong;Hong, Yong-Ju;Park, Young-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.453-458
    • /
    • 2001
  • Analysis of radiation heating system for producing 60" size PDP panels was carried out using $RADCAD^{TM}$ software. Optimum arrangement of infrared heating elements was found to obtain uniform temperature distribution in PDP panel during heating. Heating capacity of each heater was determined to obtain an appropriate maximum panel temperature. Parametric study to find the effect of design parameters such as the thermophysical and optical properties of glass and cooling system was carried out. As a reference system, about 35 kW heating capacity was chosen to obtain about 800 K maximum panel temperature after 30 minute heating. The maximum temperature difference in panel was below 20 K. The maximum/minimum and its difference in the panel were very sensitive to the variation of the emissivity of glass and cooling block.

  • PDF