• Title/Summary/Keyword: radiation cooling

Search Result 387, Processing Time 0.032 seconds

Thermal analysis of the conduction cooling system for HTS SMES system of 600 kJ class (600kJ급 SMES용 전도냉각시스템 열해석)

  • Hong, Yong-Ju;Yeom, Han-Kil;Park, Seong-Je;Kim, Hyo-Bong;Koh, Deuk-Yong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1959-1963
    • /
    • 2007
  • SMES systems need cryogenic cooling systems. Conduction cooling system has more effective, compact structure than cryogen. In general, 2 stage GM cryocoolers are used for conduction cooling of HTS SMES system. 1st stages of cryocoolers are used for the cooling of current leads and radiation shields, and 2nd stages of cryocoolers for HTS coil. For the effective conduction cooling of the HTS SMES system, the temperature difference between the cryocooler and HTS coil should be minimized. In this paper, a cryogenic conduction cooling system for HTS SMES is analyzed to evaluate the performance of the cooling system. The analysis is carried out for the steady state with the heat generation of the HTS coil and effects of the thermal contact resistance. The results show the effects of the heat generation and thermal contact resistance on the temperature distribution.

  • PDF

A Study on the Heat Transfer Characteristics of the Radiant Chilled Ceiling Panel for Space Cooling (냉각된 복사천장패널의 열전달 특성에 관한 연구)

  • Lee, Tae-Won;Hwang, In-Ju
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.164-169
    • /
    • 2001
  • There is a chilled ceiling panel which carries out the air conditioning by radiation and convection between the room and cold ceiling panel surface. In order to verify heat transfer characteristics between them in cooling system with radiant chilled ceiling panel, analytical and experimental studies were performed for various design and operating parameters such as tube space and diameter, inlet water temperature, mass flow rate, cooling load, and so on. In this study, we found that the tube space and inlet water temperature were more important elements than the tube diameter and water flow rate for the performance of radiant chilled ceiling panel. The cooling capacity of the radiant chilled ceiling panel had the maximum value of $65W/m^{2}$ because the highest cooling capacity was limited by the condensation on the panel surface. The results of comparison between numerical analysis and experiment showed a resonable agreement qualitatively, especially for low cooling capacity.

  • PDF

Development of a Numerical Model for Prediction of the Cooling Load of Nutrient Solution in Hydroponic Greenhouse (수경온실의 양액 냉각부하 예측모델 개발)

  • 남상운;김문기;손정익
    • Journal of Bio-Environment Control
    • /
    • v.2 no.2
    • /
    • pp.99-109
    • /
    • 1993
  • Cooling of nutrient solution is essential to improve the growth environment of crops in hydroponic culture during summer season in Korea. This study was carried out to provide fundamental data for development of the cooling system satisfying the required cooling load of nutrient solution in hydroponic greenhouse. A numerical model for prediction of the cooling load of nutrient solution in hydroponic greenhouse was developed, and the results by the model showed good agreements with those by experiments. Main factors effecting on cooling load were solar radiation and air temperature in weather data, and conductivity of planting board and area ratio of bed to floor in greenhouse parameters. Using the model developed, the design cooling load of nutrient solution in hydroponic greenhouse of 1,000$m^2$(300pyong) was predicted to be 95,000 kJ/hr in Suwon and the vicinity.

  • PDF

A Design for Water Cooling of a Marine Diesel Engine with Verification of Improvement (선박용 수냉식 디젤엔진의 개발 및 성능평가)

  • Sim, Hansub;Jun, Jongoh
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.6
    • /
    • pp.58-63
    • /
    • 2016
  • This paper presents a study of heat dissipation away from the fuel combustion of a marine diesel engine. These engines are operated for long periods under high load conditions: so cooling systems are necessary for radiation and control of the high temperature levels. In the study, each component of the water cooling system was developed to achieve improvements in cooling and safety. Heat transfer considerations and arrangement design for the components were important and an intercooler and exhaust manifold incorporated. An optimization of the cooling water's flow path was achieved subject to the need for convenient maintenance. The 750Ps marine diesel engine was used for performance testing of the cooling system. The test results showed adequate cooling performance improvement.

Development for Improvement Methodology of Radiation Shielding Evaluation Efficiency about PWR SNF Interim Storage Facility (PWR 사용후핵연료 중간저장시설의 몬테칼로 차폐해석 방법에 대한 계산효율성 개선방안 연구)

  • Kim, Taeman;Seo, Myungwhan;Cho, Chunhyung;Cha, Gilyong;Kim, Soonyoung
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.92-100
    • /
    • 2015
  • For the purpose of improving the efficiency of the radiation impact assessment of dry interim storage facilities for the spent nuclear fuel of pressurized water reactors (PWRs), radiation impact assessment was performed after the application of sensitivity assessment according to the radiation source term designation method, development of a 2-step calculation technique, and cooling time credit. The present study successively designated radiation source terms in accordance with the cask arrangement order in the shielding building, assessed sensitivity, which affects direct dose, and confirmed that the radiation dosage of the external walls of the shielding building was dominantly affected by the two columns closest to the internal walls. In addition, in the case in which shielding buildings were introduced into storage facilities, the present study established and assessed the 2-step calculation technique, which can reduce the immense computational analysis time. Consequently, results similar to those from existing calculations were derived in approximately half the analysis time. Finally, when radiation source terms were established by adding the storage period of the storage casks successively stored in the storage facilities and the cooling period of the spent nuclear fuel, the radiation dose of the external walls of the buildings was confirmed to be approximately 40% lower than the calculated values; the cooling period was established as being identical. The present study was conducted to improve the efficiency of the Monte Carlo shielding analysis method for radiation impact assessment of interim storage facilities. If reliability is improved through the assessment of more diverse cases, the results of the present study can be used for the design of storage facilities and the establishment of site boundary standards.

A Study of the Cooling Effect by the Long-wave Sky Radiation (장파장 천공 복사에 의한 냉각 효과에 관한 연구)

  • Kim, J.H.;Yu, J.Y.;Suh, S.J.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.4
    • /
    • pp.1-11
    • /
    • 2001
  • The authors carried out a study on the cooling effect of radiant cooling system using the metallic lightweight radiator for cooling energy saying in building. The radiant cooling performance was examined, analyzed, and presented through the case study. In this study, the cooling effect of various factors was analyzed, especially in a thin plate above the roof. These numerical results can be used as the basic design data for application of radiant cooling system. As a result of these researches, the system was verified to be an available cooling energy sources for improvement of indoor environment in summer. Finally, to complete the system can be suitable for Korean climate conditions, experimental study should be performed on the basis of these results.

  • PDF

Design of Reverse Brayton Cycle Cryocooler System for HTS Cable Cooling (HTS 케이블 냉각용 역브레이튼 사이클 극저온 냉동기 설계에 관한 연구)

  • 박재홍;권용하;김영수;박성출
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.58-65
    • /
    • 2003
  • The high temperature superconductivity(HTS) cable must be cooled below the nitrogen liquefaction temperature to applicate the cable in power generation and transmi-ssion system under the superconducting state. To obtain superconducting state. a reliable cryocooler system is required. Structural and thermal design have been performed to design cryocooler system operated with reverse Brayton cycle using gas neon as refrigerant. This cryocooler system consists of compressor. recuperator. coldbox. control valves and has 1 kW cooling capacity. Heat loss calculation was conducted for the given cryocooler system by considering the conduction and radiation through the multi-layer insulation(MLI) and high vacuum. The results can be summarized as: conduction heat loss is 7 W in valves and access port and radiation heat loss is 18 W through the surface of cryocooler. The full design specifications were discussed and the results were applied to construct in house HTS cable cooling system.

Experimental Study on the Radiative and Convective Cooling of Electronic Modules opposed to a Heated Vertical Plate (가열 수직 평판과 마주보는 전자모듈의 복사 및 대류 냉각에 대한 실험적 고찰)

  • Choi, In-Su
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.8 no.2
    • /
    • pp.105-112
    • /
    • 2005
  • The characteristics of natural convection heat transfer combined with radiation in a vertical parallel plates has been investigated experimentally. The vertical channel is consisted with a heated wall and three protruding heating sources attached on the opposite wall. The cooling of modules has been experimented with heating the wall as well as modules themselves at different aspects ratios and heating fluxes. As the location of module is higher, the temperature becomes higher, but the increasement is smaller. When the aspect ratio is lower than 26, its effect on the temperature is not significant rather than that of the radiation heat transfer. Furthermore, the correlation of Nusselt number with the Rayleigh number are attempted, but additional treatment is needed to accomodate the cases of heating module and/or opposite wall.

  • PDF

The Semi-Transparent Diamond Monochromator at the ESRF Troika Beamlines

  • Mattenet Muriel;Konovalov Oleg;Madsen Anders;Grubel Gerhard
    • Macromolecular Research
    • /
    • v.14 no.4
    • /
    • pp.473-477
    • /
    • 2006
  • The above described semi-transparent monochromators have been operational since 1997. Four units are permanently operating at the ESRF beam line ID14. Two units are in continuous operation at ID 10 and one unit is installed at the APS beamline 8-ID in USA. The water cooling of the crystals is currently being revised and above we showed that improvements most likely are possible by using micro fluidics techniques. Further tests will be performed in collaboration with the CEA-France and tested at ESRF. Parallel developments including nanofluids as coolants are under evaluation. Combination of nanofluidics and microfluidics cooling devices are under study. The authors are grateful to C. Gillot and J-A. Gruss for useful discussions and advices, and to S.Mcheik for his work on the thermal model.