• 제목/요약/키워드: radial pulse

검색결과 191건 처리시간 0.033초

한방용(韓方用) 맥파 검출시스템 (Radial Pulse Wave Detection system for the Korean Medicine)

  • 이호재;김진우;김흥오;박영배;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 추계학술대회
    • /
    • pp.66-69
    • /
    • 1991
  • This paper describes a design of transducer for non-invasively detecting pressure radial pulse wave in aterial system and a recording system that for the studing the aterial pulse diagnosis of korean traditional medicine. The mechanism of transducer is composed of sensing mechanism, pressure sensor, conditioning amplifier. The variation of radial pulse pressure in the sensing mechanism is converted to the electric signal by piezo-resistive pressure sensor and it converted to the digital signal after preprocessing via A/D converter. The converted signals inputed to the computer as data files and then it display to the monitor for waveform watching and this datas can be used as the aterial pulse diagnosis data. This system effectively detect non-differential radial pulse wave and we conside that if analizing the recorded radial pulse wave, compared each other, it can be helpful in quantify radial pulse wave diagonosis of the Korean traditional medicine.

  • PDF

음식섭취에 따른 좌우(左右) 촌관척(寸關尺) 6부위 맥파의 주파수 분석 (A Study on the Effect of Food Intake on Radial Pulse using Fourier Analysis)

  • 임윤경;박광석
    • 대한한의학회지
    • /
    • 제32권4호
    • /
    • pp.139-148
    • /
    • 2011
  • Objective: The purpose of this study was to investigate the effect of food intake on the Fourier components of radial pulse wave. Methods: Thirty-one healthy male subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 40 minutes after, 80 minutes after and 120 minutes after food intake. Fourier transform was performed and the frequency and amplitude of Fourier components were analyzed. Results: 1. The frequency and the amplitude of Fourier components of radial pulse wave increased significantly after food intake. 2. The frequency of Fourier components increased right after food intake and then gradually decreased as time passed, however the amplitude of Fourier components increased and maintained certain levels and patterns throughout the experimental period of 120 minutes. 3. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations. Conclusions: Food intake exerts an influence on radial pulse wave, resulting in increase of frequency and amplitude of Fourier components. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations.

공압 방식에 의한 다지점 요골 맥파 검출 장치 (Multi-Point Radial Artery Pulse Wave Transducer using Pneumatic System)

  • 이종진;정민석;황성하;이종현;이선규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.243-248
    • /
    • 2001
  • A radial artery pulse wave is well known as a good mans to diagnose human body condition in th field of Chinese medical science. Information about constitution as well as organs can be obtained by detecting the artery pulse wave. Recently, the information about the human body constitution may be utilized in accelerating the recovery process of the patient on the basis of comprehensive diagnosis. A radial artery pulse wave is considered as one of promising means in examining the human body constitution. Since the examination has been conducted by the feeling of finger, the diagnosis may occasionally have uncertainty or fatal error. In this paper, a new measuring system is suggested and developed to examine the pattern of a pulse wave correctly. The system is composed of four pressure vessels, pressure sensors and air supplying pumps. One of them is utilized for appropriately pressing the radial artery, three of them for detecting pressure change in several mmHg level. The detected data is shown and discussed.

  • PDF

맥파의 특징점 인식과 파형의 분류에 관한 연구 (The Study on the Feature Point Recognition and Classification of Radial Pulse)

  • 길세기;김낙환;이상민;박승환;홍승홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.555-558
    • /
    • 1999
  • In this paper, Ire present the result of feature points recognition and classification of radial pulse by the shape of pulse wave. The recognition algorithm use the method which runs in parallel with both the data of ECG and differential pulse simultaneously to recognize the feature points. Also we specified 3-time elements of pulse wave as main parameters for diagnosis and measured them by execution of algorithm. then we classify the shape of radial pulse by existence and position of feature points.

  • PDF

요골동맥 직경 변화에 따른 맥파 측정 시스템 개발 (Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation)

  • 이전;우영재;전영주;이유정;김종열
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

Sa-Am Acupuncture with Spleen Seung-gyuck induces an acute increase of radial pulse parameters related to arterial stiffness in healthy subjects: A comparative study of Jung-gyuck and Seung-gyuck

  • Yim, Yun-Kyoung
    • 대한한의학회지
    • /
    • 제35권2호
    • /
    • pp.19-27
    • /
    • 2014
  • Objectives: To investigate the different effects of Sa-Am acupuncture with Spleen Jung-gyuck and Spleen Seung-gyuck on the radial pulse in healthy subjects. Methods: Sixty healthy volunteers (30 males and 30 females) participated in this study. The participants were randomly divided into three groups: control (C), Sa-Am acupuncture with Spleen Jung-gyuck (SP+) and Sa-Am acupuncture with Spleen Seung-gyuck (SP-). The radial pulse was measured using a multi-step tonometry system before, and 0, 30 and 60 minutes after acupuncture. Results: The heart rate adjusted radial augmentation index (RAI/HR) and high-tensioned pulse area (W area) significantly increased in the SP- group compared to the C and SP+ groups in males. The systolic pulse period (T4) increased significantly in the SP- group compared to the C and SP+ groups in females. The RAI/HR had positive correlations with W area and T4. Conclusion: The effects of Sa-Am acupuncture with Spleen Jung-gyuck and Spleen Seung-gyuck are different. Sa-Am acupuncture with Spleen Seung-gyuck induces acute increases of radial pulse parameters related to arterial stiffness in healthy subjects.

비정격(脾正格) 자침이 정상 성인 맥파(脈波) 변화에 미치는 영향 (The Effects of Sa-Am Spleen-tonifying Acupuncture on Radial Pulse in Healthy Human Subjects)

  • 윤광식;이현
    • Journal of Acupuncture Research
    • /
    • 제30권4호
    • /
    • pp.1-14
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the effects of Sa-Am spleen-tonifying acupuncture on radial pulse in healthy human subjects. Methods : Forty healthy human subjects participated in this study, divided into acupuncture group and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after and 60 minutes after acupuncture in the acupuncture group. The subjects in the control group didn't received acupuncture but took a rest and then the radial pulse was measured at the same time points as the acupuncture group. The parameters were analyzed by gender, measuring location, and measuring time point. However the time related parameters exceptionally were analyzed without distinction of measuring location. Results : 1. T, variance of period, T2/T, T4/T, (T-T4)/T, T4/(T-T4), and W significantly changed after acupuncture. 2. Pressure, amplitude of H1, amplitude of H2, Amplitude of H4 and pulse energy significantly changed after acupuncture. 3. Pulse area, systolic pulse area and diastolic pulse area significantly changed after acupuncture. 4. Elasticity, AIx and AIx/HR significantly changed after acupuncture. Conclusions : The effect of Sa-Am spleen-tonifying acupuncture in healthy human may be observed on time, amplitude, pulse area and augmentation index. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.

적혈구 용적이 요골 동맥의 맥파에 미치는 영향 (Effect of Hematocrit Level on the Radial Pulse Wave)

  • 유현희;전영주;김재욱;이혜정;우영재;이유정;김종열
    • 동의생리병리학회지
    • /
    • 제23권5호
    • /
    • pp.1035-1040
    • /
    • 2009
  • In this work, we investigate the effect of blood hematocrit level on the radial pulse wave to study the clinical application of the pulse analyzer. For this purpose, we measured the radial pulse wave at the left Gwan for 15 males with abnormal high hematocrit level and 47 males with normal hematocrit level at the age of thirties and forties. Various variables of the radial pulse wave between two groups were analyzed by Student's T test. We found significant differences in several characteristic variables in the amplitude, time-span and the integrated area of the amplitude and time of the pulse wave. The systolic peak in the amplitude of the radial pulse wave was higher in abnormal high hematocrit group. In contrast, the third peak from the second incisure was higher and longer in normal hematocrit group. Our study suggests that the radial pulse wave can be useful in distinguishing the patient group with high hematocrit level and thus with high blood viscosity. Our finding may motivate research activities towards diverse clinical applications of the pulse wave.

A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices

  • Lee, Sang-Suk;An, Myoung-Chone;Ahn, Sung-Hoon
    • Journal of Magnetics
    • /
    • 제14권3호
    • /
    • pp.132-136
    • /
    • 2009
  • This study investigated the radial pulse waveform obtained by a medical pulsimeter sensor. A pulse-sensing part array consisting of multiple Hall devices was located over a skin-contacting part with a hard magnetic material. The periodic movement of the magnetic material of the skin-contacting part affected the magnetic field in the pulse-sensing part array and was detected by multiple Hall devices. The analysis of a radial pulse waveform that is measured noninvasively by detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of oriental medical apparatus.

맥상기를 통한 요골동맥 맥진법의 맥파분석 - 좌관부위 맥파요인을 중심으로 - (Study on the Waveform Analysis of Radial Artery Pulse Diagnosis Using Pulse Meter and Analyzer - the Waveform Analysis of Left KWAN Pulse Dignosis -)

  • 김경철;이정원;류경호;박동일;신우진;강희정
    • 동의생리병리학회지
    • /
    • 제23권1호
    • /
    • pp.186-191
    • /
    • 2009
  • In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research. As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(CHON, KWAN, CHEOG). First of all, in this research, we did the experiment of the study on the waveform analysis of radial artery(left KWAN) pulse dignosis by using 3 dimension pulse meter and analyzer (3D MAC). As a result. we extracted the seven measurement fluents : energy(E), size of cycle(h1), size of reflection cycle(h2), time of reflection cycle(t2), time of contraction (t4), width of cycle(w), area of waveform(A) by the statistically reasonable differences. We expect that the seven measurement fluents contribute to divide the situation through the results of waveform analysis of radial artery.