• Title/Summary/Keyword: radial

Search Result 5,360, Processing Time 0.03 seconds

Determining Optimum Pumping Rates of Groundwater in Ttansum Island Related to Riverbank Filtration

  • Lee, Chung-Mo;Hamm, Se-Yeong;Choo, Yeon-Woo;Kim, Hyoung-Soo;Cheong, Jae-Yeol
    • Journal of Environmental Science International
    • /
    • v.27 no.10
    • /
    • pp.831-844
    • /
    • 2018
  • Riverbank Filtration (RBF) is a kind of indirect artificial recharge method and is useful in obtaining higher-quality source water than surface water when procuring municipal water. This study evaluated optimal riverbank filtered water and the productivity of the radial collector wells on Ttansum Island in the area downstream of the Nakdong River, where Gimhae City is constructing a municipal water plant for the purpose of acquiring high-quality water. The RBF wells are planned to provide water to the citizens of Gimhae City through municipal water works. Groundwater flow modeling was performed with the following four scenarios: (a) 9 radial collector wells, (b) 10 radial collector wells, (c) 10 radial collector wells and two additional vertical wells, and (d) 12 radial collector wells. This study can be useful in determineing the optimum production rate of bank filtrated water not only in this study area but also in other places in Korea.

Measurement Method of Residual Stresses in Thick Composite Cylinders (두꺼운 복합재 원통의 잔류응력 측정방법)

  • Kim, Jong-Woon;Park, Dong-Chang;Lee, Dai-Gil
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.245-248
    • /
    • 2005
  • During manufacturing thick composite cylinders, large thermal residual stresses are developed and induce catastrophic interlaminar failures. Since the residual stresses are dependent on many process parameters, such as temperature distribution during cure, cure shrinkage, winding tension, and migration of fibers, calculation of the residual stresses is very difficult. Therefore a radial-cut method have been used to measure the residual stresses in the composite cylinders. But the conventional radial-cut method needs to know numerous material properties which are not only troublesome to obtain but also vary with change of fiber arrangement during consolidation. In this paper, a new radial-cut method with cut-cylinder-bending test was proposed and the measured residual stresses were compared with calculated thermal residual stresses. It was found that the new radial-cut method which does not need to know any of material properties gave better estimation of residual stresses regardless of radial variation of material properties. Additionally, interlaminar tensile strength could be obtained by the cut-cylinder-bending test.

  • PDF

Functional Reconstruction of the Oral Cavity with Radial Forearm Free Flap

  • Kim, Min-Sik
    • 대한두경부종양학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.80-84
    • /
    • 2007
  • Background and Objectives : The radial forearm free flap is a useful reconstructive method of surgical defects after oral and oropharyngeal tumor resection. We evaluated the swallowing and speech outcomes of radial forearm free flap reconstruction for oral and oropharyngeal cancers. Materials and Methods : We retrospectively reviewed clinical data of 84 patients who underwent reconstructive surgery for oral or oropharyngeal cancer using radial forearm free flap from August 1994 to January 2007. Modified barium swallowing (MBS) was done in 100 patients and speech-language assessment was done in 23 patients by a speech-language pathologist. Results were analyzed according to the swallowing functions and the speech-language assessments. Results : According to the results of MBS which was done postoperatively, aspiration occurred in three patients and velopharyngeal insufficiency occurred in four patients who had been reconstructed with multilobed free flap due to large mucosal defects. There was one patient who exhibited severe articulation impairment out of 23 patients. However, 19 patients out of 23 patients showed excellent intelligibility in speech. Conclusion : We concluded that the radial forearm free flap technique is an excellent reconstructive method for the restoration of palatal and pharyngeal function in oral and oropharyngeal cancer patients.

  • PDF

Reconstruction of Suborbital area using Composite Radial Forearm Free Flap with Palmaris Longus Tendon immediately after Wide Excision of Skin Cancer (피부 악성 종양 절제 후 장장근건을 포함한 복합 요골 전완 유리 피판술을 이용한 중안면부의 재건)

  • Lee, Hyun-Taek;Minn, Kyoung-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.1
    • /
    • pp.60-63
    • /
    • 2001
  • The reconstruction of the suborbital area followed by resection of skin cancer has been used many methods including skin graft, local flaps, free flaps, and skin expansion. The radial forearm free flap has become a workhorse flap in this area because of its lack of bulk, ease of dissection, malleability, and hairlessness. When the suborbital defect especially including full-thickness defect of lower lid was reconstructed with many free flaps, the ectropion and the deformity of medial and lateral canthal area were common problems encountered as late complication due to gravitational descent. To improve the final aesthetic result in patients with suborbital defect, the radial forearm free flap was elevated as a composite radial forearm - palmaris longus free flap, in which the vascularized palmaris longus london was included and anchored to the periorbital bone with $mitek^{(R)}$ as sling, to suspend the flap against gravity and inferior descent, and thereby creating a more natural cheek contour. Two clinical cases were presented as an example of this procedure. Postoperative results emphasize the importance of suspension sling with palmaris longus tendon using $mitek^{(R)}$ in reconstruction of the suborbital defect with radial forearm free flap.

  • PDF

Ultrasonography in Radial Nerve Palsy after Surgery of Humerus Shaft Fracture - Case Report - (상완골 간부 골절 수술 후 발생한 요골신경 마비에서 시행한 초음파 검사 -증례 보고-)

  • Yoon, Hyungmoon;Kho, Dukhwan;Kim, Hyeungjune;Nam, Kyoungmo;Kang, Daemyung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.106-112
    • /
    • 2012
  • Radial nerve palsy after surgery of humerus fracture is uncommon complication. Occasionally it needs operative treatment because of difficulty to accurate evaluation. We report this case of radial nerve palsy after surgery of humerus shaft fracture with ultrasound examination. We checked the continuity of radial nerve and radial nerve palsy was complete recovered with conservative treatment.

  • PDF

ABSORPTION LINE GRADIENTS OF AN ELLIPTICAL GALAXY

  • Sohn, Young-Jong;Rhee, Myung-Hyun;Yoon, Suk-Jin
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.105-114
    • /
    • 1999
  • Archival long-slit spectra, covering the wavelength range 4050~5150$\AA$, have been used to investigate the radial behavior of absorption line features (G4300, Fe4383, Ca4455, Fe44531, Fe4668, and H$\beta$) of an eliptical galaxy NGC 5322. The heliocentric recession velocity of NGC 5322 has been derived as 1888$\pm$51kms-1. Metallic absorption lines of NGC 5322 show significant radial gradients through the major axis. The minor axis shows much smaller radial metal line gradients than the major axis. The minor axis shows much smaller radial metal line gradients than the major axis. The mean slopes of Fe line gradients to the major and minor axes of NGC 5322 were estimated as -0.433$\pm$0.064 and -0.242$\pm$0.096, respectively. Significant radial gradients of H$\beta$ absorption of NGC 5322 are also detected both on the major and minor axes. It is shown that the radial metallicity gradients in NGC 5322 are smaller than expected in a simple dissipative collapse model. Rather, dissipationless collapse, such as hierarchical merhing, could have contributed during the initial stage of the galaxy formation.

  • PDF

A Method for Reducing the Effect of Disk Radial Runout for a High-Speed Optical Disk Drive (고속 광 디스크 드라이브를 위한 디스크의 편심 보상 방법)

  • Ryoo Jung Rae;Moon Jung-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.2
    • /
    • pp.101-105
    • /
    • 2006
  • Disk radial runout creates a periodic relative motion between the laser beam spot and tracks formed on an optical disk. While only focus control is activated, the periodic relative motion yields sinusoid-like waves in the tracking error signal, where one cycle of the sinusoid-like waves corresponds to one track. The frequency of the sinusoid-like waves varies depending on the disk rotational speed and the amount of the disk radial runout. If the frequency of the tracking error signal in the off-track state is too high due to large radial runout of the disk, it is not a simple matter to begin track-following control stably. It might take a long time to reach a steady state or tracking control might fail to reach a stable steady state in the worst case. This article proposes a simple method for reducing the relative motion caused by the disk radial runout in the off-track state. The relative motion in the off-track state is effectively reduced by a drive input obtained through measurements of the tracking error signal and simple calculations based on the measurements, which helps reduce the transient response time of the track-following control. The validity of the proposed method is verified through an experiment using an optical disk drive.

Sa-Am Acupuncture with Spleen Seung-gyuck induces an acute increase of radial pulse parameters related to arterial stiffness in healthy subjects: A comparative study of Jung-gyuck and Seung-gyuck

  • Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.35 no.2
    • /
    • pp.19-27
    • /
    • 2014
  • Objectives: To investigate the different effects of Sa-Am acupuncture with Spleen Jung-gyuck and Spleen Seung-gyuck on the radial pulse in healthy subjects. Methods: Sixty healthy volunteers (30 males and 30 females) participated in this study. The participants were randomly divided into three groups: control (C), Sa-Am acupuncture with Spleen Jung-gyuck (SP+) and Sa-Am acupuncture with Spleen Seung-gyuck (SP-). The radial pulse was measured using a multi-step tonometry system before, and 0, 30 and 60 minutes after acupuncture. Results: The heart rate adjusted radial augmentation index (RAI/HR) and high-tensioned pulse area (W area) significantly increased in the SP- group compared to the C and SP+ groups in males. The systolic pulse period (T4) increased significantly in the SP- group compared to the C and SP+ groups in females. The RAI/HR had positive correlations with W area and T4. Conclusion: The effects of Sa-Am acupuncture with Spleen Jung-gyuck and Spleen Seung-gyuck are different. Sa-Am acupuncture with Spleen Seung-gyuck induces acute increases of radial pulse parameters related to arterial stiffness in healthy subjects.

A Case of Radial Nerve Palsy (요골신경마비(撓骨神經痲痺) 치험(治驗) 1례(例))

  • Lee, Se-yun;Lee, Kyung-min;Jung, Tae-young;Seo, Jung-chul;Han, Sang-won
    • Journal of Acupuncture Research
    • /
    • v.20 no.1
    • /
    • pp.236-243
    • /
    • 2003
  • Objective : The purpose of this study is to report the patient with radial nerve palsy, who improved by oriental medical treatment. Methods : The patient was managed by bee venom aqua-acupuncture, sclp acupuncture and herbal medicine. We took picture of the patients's wrist and checked the power of muscles. Results : After 4 week treatment, the movement and power of wrist was restored of nearly normal range. also the numbness of hand was removed. Combined oriental medical treatment can treat radial nerve palsy earlier than other methods. Conclusions : The results suggest that combination of bee venom aqua-acupuncture, scalp acupuncture and herbal medicine is good method for treatment of radial nerve palsy. But further studies are required to concretely prove the effectiveness of this methods for treating radial nerve palsy.

  • PDF

Radial Pulse Wave Detection system for the Korean Medicine (한방용(韓方用) 맥파 검출시스템)

  • Lee, H.J.;Kim, J.W.;Kim, H.O.;Park, Y.B.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.66-69
    • /
    • 1991
  • This paper describes a design of transducer for non-invasively detecting pressure radial pulse wave in aterial system and a recording system that for the studing the aterial pulse diagnosis of korean traditional medicine. The mechanism of transducer is composed of sensing mechanism, pressure sensor, conditioning amplifier. The variation of radial pulse pressure in the sensing mechanism is converted to the electric signal by piezo-resistive pressure sensor and it converted to the digital signal after preprocessing via A/D converter. The converted signals inputed to the computer as data files and then it display to the monitor for waveform watching and this datas can be used as the aterial pulse diagnosis data. This system effectively detect non-differential radial pulse wave and we conside that if analizing the recorded radial pulse wave, compared each other, it can be helpful in quantify radial pulse wave diagonosis of the Korean traditional medicine.

  • PDF