• Title/Summary/Keyword: rabbit pyrogen test

Search Result 7, Processing Time 0.018 seconds

Studies on Effects of Antibiotics on Pyrogen Tests

  • Shin, Kwang-Bum;Song, Young-Joon;Kim, Jung-Woo
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.2
    • /
    • pp.85-88
    • /
    • 1986
  • To estimate the effect of some injectable antibiotics (ampicillin sodium, cefazolin sodium, cephaloridine, cefuroxime sodium and chloramphenicol sodium succinate) on pyrogen tests, the Limulus amebocyte lysate (LAL) test and an ultrafiltration technique were used. The rabbit pyrogen test was also used in the case of cafazolin sodium. At high antibiotic concentrations, these samples which were artificially contaminated with endotoxin inhibited the gelation reaction of LAL. But the gelation reaction occurred when most of the antibiotic was removed by ultrafiltration. Likewise, cefazolin sodium interfered not only with the LAL test but also with the rabbit pyrogen test. From these results it can be said that special modification to eliminate interference should be taken into consideration for valid method of pyrogen tests in the parenteral products containing these antibiotics.

  • PDF

Effect of Aluminum on $TNF-{\alpha}$ Secretion from Murine RAW264.7 Cells for Endotoxin Detection in Hepatitis B Vaccines

  • Park Chul-Yong;Lee Sun-Suk;Rhee Dong-Kwon
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.2
    • /
    • pp.219-225
    • /
    • 2006
  • The rabbit pyrogen test and Limulus amoebocyte lysate (LAL) assay have been used to detect endotoxins present in vaccines. Currently, the rabbit pyrogen test is used to detect endotoxins in hepatitis B (HB) vaccines, even though the HB surface protein, which is the active ingredient, is overexpressed in and purified from eukaryotic cells that lack these endotoxins. Although the LAL clot assay is sensitive and reliable and can be used to replace the rabbit pyrogen test, its reaction is limited by the lack of responsiveness to the Gram-positive bacterial components. Furthermore, aluminum hydroxide in the HB vaccine can interfere with the LAL assay. In contrast, macrophages can detect the endotoxin as well as other pyrogens, and secrete $TNF-{\alpha}$. Therefore, this study was undertaken to examine the possibility of replacing the animal tests with a more efficient $TNF-{\alpha}$ secretion assay. With this in mind, we determined if aluminum hydroxide in the HB vaccines affects the $TNF-{\alpha}$ secretion assay. HB vaccines and the HB protein solutions spiked with lipopolysaccharide (LPS) produced the same level of dose-dependent $TNF{\alpha}$ secretion and temperature increase in rabbits, indicating that aluminum hydroxide in the HB vaccine does not interfere with the pyrogenic response in rabbits, nor does it interfere with $TNF-{\alpha}$ secretion. In addition, the $TNF-{\alpha}$ assay was found to be more sensitive than the LAL assay, and correlated well with the pyrogen test and the LAL assay. These results suggest that the $TNF-{\alpha}$ assay in RAW264.7 cells is a good substitute for the current pyrogen assays that are used for detecting LPS in HB vaccines as well as in other vaccines containing aluminum.

Comparison of LAL Test with Pyrogen Test (발열성 물질시험과 세균 내독소 시험의 비교 연구)

  • 이유경;강윤숙;백선영;김용관;신광훈;민홍기
    • YAKHAK HOEJI
    • /
    • v.43 no.5
    • /
    • pp.606-613
    • /
    • 1999
  • To survey the possibility of replacing the pyrogen test with Limulus Amebocyte Lysate(LAL) test and to find out a standard methods suitable to our blood products made in Korea, 100 samples of 20% human serum albumin were tested by commercial LAL test kits and results of those were compared with rabbit pyrogen test. The LAL test is used both dinetic-chromogenically and kinetic-turbidimetrically. Both methods equally showed broad detection range (5.0~0.005 EU/ml), excellent sensitivity ($\geq$ 0.005 EU/ml) and predominant recovery rate within valid dilution range, but kinetic-turbidimetric method seemed to be more reproducible than kinetic-chromogenic method(kinetic-chromogenic method : S.D. = 15.88, kinetic-turbidimetric method : S.D. = 8.12). After heating the sample at 75$^{\circ}C$ for 15 min, the results showed a little elevated recovery rate with both methods. After performing the test on 100 albumin samples with both kits, the results were analysed using the USP standard (1.33 EU/ml). 7% of samples in kinetic-chromogenic methods and 1% of samples in kinetic-turbidimetric method exceeded the limit of endotoxin levels regulated for blood products in USA. Because this phenomenon was not observed in both methods at the same time and both methods have high sensitivity ($\geq$0.005 EU/ml), these results seemed to depend on nonspecific reaction. Considering its sensitivity and reproducibility, we could assure that LAL test is proper to detecting pyrogenic with good sensitivity.

  • PDF

INFLUENCE OF LOW OR HIGH ENDOTOXIN-SUSCEPTIBLE RABBIT ON PYROGEN TEST

  • Lee, Beom-Jun;Lee, Yong-Soon
    • Toxicological Research
    • /
    • v.4 no.2
    • /
    • pp.181-188
    • /
    • 1988
  • This study was carried out to investigate whether the use of the high endotoxin-sensitive or the low endotoxin-sensitive rabbits (New Zealand White strain) are more suited for the pyrogen test regulated by the Korean Pharmacopeia and United State Pharmacopeia. The results obtained were as follows. 1. The ferbrile responese were increased according to increased endotoxin doses used (i.e., 0.1, 1, 5, 10ng/kg) and the febrile responses reached to its maximum between 90 mins and 120 mins after the intravenous injection of endotoxin.

  • PDF

Studies on the Yellow Pigment Produced by Monascus sp. CS-2 (Part 3) Safety Test of Yellow Pigment (Monascus sp. CS-2가 생산하는 황색색소에 관한 연구 (제3보) 황색색소의 안전성 시험)

  • Kim, Hyun-Soo;Jang, Wook;Son, Chung-Hong;Bae, Jong-Chan;Yoo, Ju-Hyun
    • Microbiology and Biotechnology Letters
    • /
    • v.9 no.3
    • /
    • pp.117-121
    • /
    • 1981
  • Safety of yellow pigment produced by Monascus sp. CS-2 was evaluated. Acute oral toxicity, pyrogen test, and histamine test, as well as antimicrobial activity were determined. The results obtained were; LD oral in mice was 132.5 mg/20 g, pyrogen test in rabbit was 5 mg/kg, and histamine test in cat was 10 mg/kg. Also the pigment was particularly sensitive to Bacillus subtilis (ATCC 6633), Sarcina lutea (ATCC 9341) and Staphylococcus aureus (ATCC 6538 P), whereas not sensitive to Pseudomonas pyosyanea (ACTC 10490), Bacillus var. mycoides (ATCC 11778), Bordetella bronchiseptica (ATCC 4617) and Staphylococcus epidermidis(ATCC 12228).

  • PDF

An experimental study on the biological safety and compatability of P.V.C. made in Korea (한국산 P.V.C.의 생물학적 안정도 및 적합성에 대한 실험적 고찰)

  • Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.157-166
    • /
    • 1984
  • These biologic test procedures are designed to test the suitability of P.V.C. made in Korea intended for parenteral preparation, which were based on the U.S. Pharmacopeia XIX "Biologic Test-Plastic Container", Official from July 1, 1975. Healthy adult human blood and rabbits weighing 2\ulcorner.2Kg were used for test materials. Sample P.V.C. were sampled from the medical equipments made in Korea randomly and Control P.V.C. were sampled from the standardized Cobe and Polystan P.V.C. tubes. P.V.C. extract was prepared from a homogeneous P.V.C. samples by incubating 60 square centimeters of the sample per 20 millimeters of sterile pyrogen-free saline at 70\ulcorner for 72 hours or autoclaving at 120\ulcorner for 1 hour. The Implantation Test was designed to evaluate the reaction of living tissue to the plastic by the method of the implantation of the Sample itself into animal tissue. The Systemic Injection Test, the Intracutaneous Test, and the remainders were designed to determine the biological response of animals to plastics by the single-dose injection of specific extracts prepared from a Sample. The results are as follows; 1.Implantation Test - No significant difference for reactions was noted between the Sample treated animal and the Control after 72 hours of implantation. 2.Systemic Toxicity Injection Test - No sign of toxicity and/or death immediately after injection and at 4, 24, 48 hours respectfully after injection. 3.Intracutaneous Test - None of the animals treated with the Sample showed a significantly greater reaction than the observed in the animals treated with Blank. 4.Pyrogen Assay-Only one animal treated with the Sample showed the maximal rise of rectal temperature about 0.2\ulcorner after 3 hours of injection, but remainders showed no change. 5.Hemolytic Index - The positive Control tube of distilled water exhibited complete hemolysis while the negative Control tube and P.V.C. extract were negative demonstrating no hemolysis. 6.Cell Morphology of Erythrocytes and Leukocytes on Stored, Heparinized Human Blood -- There was no significant difference in the morphology of either the Control or Sample extract. 7.Clotting Mechanism of Human Blood in vitro - After allowing to the P.V.C. extract at room temperature for 5 Hours and at 10\ulcorner for 24 hours, there was no appreciable difference in Prothrombin Time under these conditions. 8.Clotting Mechanism of Rabbit in vivo - At the termination of 5 days after intraperitoneal injection of the P.V.C. extract, no significant changes in Clotting Time were observed. According to the above results, it could be concluded that the P.V.C. made in Korea was acceptable for parenteral preparation, especially treated with physiologic saline and/or human blood.man blood.

  • PDF

Histological Observation of Bone Reaction with Relation to Surface Treatment of Titanium (생체합금 Titanium의 표면처리에 따른 골반응의 변화에 대한 조직학적 관찰)

  • Ahn, Myun-Whan;Choi, Yong-Sug;Ahn, Jong-Chul;Seo, Jae-Sung;Lee, Dong-Chul;Jang, Jae-Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.116-133
    • /
    • 1996
  • The biocompatibility of the titanium has been estabilished through various experimental studies such as cell culture toxicity test, pyrogen test, mutagen test and others. In order to confirm biocompatibility after fabrication of titanium and to clarify the difference between the bone reaction after insertion of the lathed titanium rods and the bone reaction after insertion of the finished and polished rods, both rods were implanted into the proximal femur of a rabbit. Histologic reactions in the bone were observed according to the ASTM standards at the intervals of 6 weeks, 12 weeks and 26 weeks after implantation. The result were as follows : In 6 weeks after implantation of lathed titanium rods, inflammatory reactions, such as minimal degree infiltration of polymorphonuclear leukocytes and lymphocytes were observed in all cases. This was thought to he caused by surgical trauma. However, inflammatory cell infiltration was not seen after implantation of polished and finished rods in all cases. The cellular infiltration and the histologic reaction of the hone after implantation of lathed group were significantly more pronounced than those after implantation of the finished group. In 12 weeks after implantation of lathed rods, two of four cases revealed a minimal degree of cellular infiltration. No inflammatory cell infiltration was demonstrated after implantation of the finished group. The cellular infiltration and histologic reaction seemed to be more pronounced in the lathed group, but they were not significant statistically. At 26 weeks after implantation of the lathed and finished group, there was no cellular infiltration in both groups. New bone formation was observed up 26 weeks, and no difference between lathed titanium rods and finished titanium rods were apparent. Mild bone necrosis was observed in 1 case out of 11 cases in which lathed titanium rods were implanted. Bone necrosis was not observed in the finished titanium rod group. Fibrosis was observed in both groups, but differences were not significant between the experimental groups. In the lathed titanium rods group and the shorter interval group, inflammatory cell infiltration was significantly higher. Finished titanium rods and longer interval groups had markedly decreased tendences in histologic reaction ratings. As a conclusion, although certificated titanium might be safe to use, difference of biocompatibility were observed depending on the method of surface finish. By identifying biocompatibility as a long-term standardized animal study, we can develop progressed internal fixation device that is safe for human beings.

  • PDF