• Title/Summary/Keyword: r-closure

Search Result 210, Processing Time 0.023 seconds

Numerically integrated modified virtual crack closure integral technique for 2-D crack problems

  • Palani, G.S.;Dattaguru, B.;Iyer, Nagesh R.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.6
    • /
    • pp.731-744
    • /
    • 2004
  • Modified virtual crack closure integral (MVCCI) technique has become very popular for computation of strain energy release rate (SERR) and stress intensity factor (SIF) for 2-D crack problems. The objective of this paper is to propose a numerical integration procedure for MVCCI so as to generalize the technique and make its application much wider. This new procedure called as numerically integrated MVCCI (NI-MVCCI) will remove the dependence of MVCCI equations on the type of finite element employed in the basic stress analysis. Numerical studies on fracture analysis of 2-D crack (mode I and II) problems have been conducted by employing 4-noded, 8-noded (regular & quarter-point), 9-noded and 12-noded finite elements. For non-singular (regular) elements at crack tip, NI-MVCCI technique generates the same results as MVCCI, but the advantage for higher order regular and singular elements is that complex equations for MVCCI need not be derived. Gauss numerical integration rule to be employed for 8-noded singular (quarter-point) element for accurate computation of SERR and SIF has been recommended based on the numerical studies.

A Study on Fatigue Crack Propagation Behavior of Pressure Vessel Steel SA516/70 at High Temperature. (압력용기용 SA516/70 강의 고온피로균열 진전거동에 대한 연구)

  • 박경동;김정호;윤한기;박원조
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.147-153
    • /
    • 2000
  • The fatigue crack propagation behavior of the SA516/70 steel which is used for pressure vessels was examined experimentally at room temperature, $150^{\circ}C$, $250^{\circ}C$ and $370^{\circ}C$ with stress ratio of R=0.1 and 0.3. The fatigue crack propagation rate da/dN related with the stress intensity factor range $\Omega\textrm{K}$ was influenced by the stress ratio within the stable growth of fatigue crack(Region II) with an increase in $\Omega\textrm{K}$. The resistance to the fatigue crack growth at high temperature is higher in comparison with that at room temperature, and the resistance attributed to the extent of plasticity-induced by compressive residual stress according to the cyclic loads. Fractographic examinations reveal that the differences of the fatigue crack growth characteristics between room and high temperatures are mainly explained by the crack closure and oxide-induced by high temperature.

  • PDF

Evaluation of Reactor Internals Integrity due to 5.5m Concentric Free Fall of KSNP+ Reactor Vessel Closure Head (KSNP+ 원자로덮개 5.5m 수직 낙하 시 원자로내부구조물 건전성 평가)

  • Namgyng, Ihn;Jeong, Seung-Ha;Lee, Dae-Hee;Choi, Taek-Sang
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1358-1363
    • /
    • 2003
  • Due to the application of Integrated Head Assembly (IHA) in KSNP+ reactor design, an investigation of reactor internals integrity is carried out to assure that the adoption of IHA does not affect the safety of reactor operation. One of the postulated accident events is the R.V. closure head fall from 5.5m high directly above the reactor vessel that may occur during the refueling operation. The analysis model consists of lumped mass elements of the entire reactor vessel and internals. Because of extreme load, separate elastic-plastic analyses are done for the members that undergo plastic deformation. The analysis verified that the stresses of the reactor internals and the fuel assemblies are within the bound of allowable stress limits and the integrity of the fuel assemblies is maintained.

  • PDF

A Study on Fatigue Crack propagation Behavior of Pressure Vessel Steel SA516/70 at High Temperature (압력용기용 SA516/70 강의 고온피로균열 진전거동에 대한 연구)

  • 박경동;김정호;윤한기;박원조
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.105-110
    • /
    • 2001
  • The fatigue crack propagation behavior of the SA516/70 steel which is used for pressure vessels was examined experimentally at room temperature, 150$^{\circ}C $, 250$^{\circ}C $ and 370$^{\circ}C $ with stress ratio of R=0.1 and 0.3. The fatigue crack propagation rate da/dN related with the stress intensity factor range $\Delta K$ was influenced by the stress ratio within the stable growth of fatigue crack(Region II) with an increase in $\Delta K$. The resistance to the fatigue crack growth at high temperature is higher in comparison with that at room temperature, and the resistance attributed to the extent of plasticity-induced by compressive residual stress according to the cyclic loads. Fractographic examinations reveal that the differences of the fatigue crack growth characteristics between room and high temperature are mainly explained by the crack closure and oxide-induced by high temperature.

  • PDF

Retardation of Fatigue Crack Propagation by Single Overloading (단일과대하중에 의한 피로균열전파의 지연거동)

  • 김상철;함경춘;강동명
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.1
    • /
    • pp.20-29
    • /
    • 1992
  • Effects of strain hardening exponents on the retardation behavior of fatigue crack propagation are experimentally investigated. The retardation of fatigue crack propagation seems to be induced by the crack closure at crack tip. The phenomenon of crack closure becomes remarkable with the increment of strain hardening exponent and magnitude of percent peak load. The ratio of crack growth increment(a$\_$d//w$\_$d/) is influenced by a single overloading (a$\_$d/) and estimated plastic zone size (W$\_$d/=2r$\_$y/) is increased according with the increasing of strain ha.dening exponents. The number of retarded crack growth cycles were (N$\_$d/) decreased as the baseline stress intensity factor .ange( K$\_$b/) was increased. Within the limitation of these experimental results obtained under the single overload, an empirical relation between crack retardation ratio (Nd/N*), strain hardening exponent (n) and percent peak load (%PL) has been proposed as; Nd/N*= exp [PL $.$ PL$.$A(n)+B(n) ] where, A(n)=${\alpha}$n+${\beta}$, B(n)=${\gamma}$n+$\delta$, PL=%PL/100 and ${\alpha}$=0.78, ${\beta}$=0.54, ${\gamma}$=0.58 and $\delta$=-0.01, It is interesting to note that all these constants are identical for materials such as aluminum(A3203), steel(S4SC), steel(SS41) and stainless steel(SUS316) used in this experimental study.

  • PDF

CHARACTERIZATION OF FUNCTIONS VIA COMMUTATORS OF BILINEAR FRACTIONAL INTEGRALS ON MORREY SPACES

  • Mao, Suzhen;Wu, Huoxiong
    • Bulletin of the Korean Mathematical Society
    • /
    • v.53 no.4
    • /
    • pp.1071-1085
    • /
    • 2016
  • For $b{\in}L^1_{loc}({\mathbb{R}}^n)$, let ${\mathcal{I}}_{\alpha}$ be the bilinear fractional integral operator, and $[b,{\mathcal{I}}_{\alpha}]_i$ be the commutator of ${\mathcal{I}}_{\alpha}$ with pointwise multiplication b (i = 1, 2). This paper shows that if the commutator $[b,{\mathcal{I}}_{\alpha}]_i$ for i = 1 or 2 is bounded from the product Morrey spaces $L^{p_1,{\lambda}_1}({\mathbb{R}}^n){\times}L^{p_2,{\lambda}_2}({\mathbb{R}}^n)$ to the Morrey space $L^{q,{\lambda}}({\mathbb{R}}^n)$ for some suitable indexes ${\lambda}$, ${\lambda}_1$, ${\lambda}_2$ and $p_1$, $p_2$, q, then $b{\in}BMO({\mathbb{R}}^n)$, as well as that the compactness of $[b,{\mathcal{I}}_{\alpha}]_i$ for i = 1 or 2 from $L^{p_1,{\lambda}_1}({\mathbb{R}}^n){\times}L^{p_2,{\lambda}_2}({\mathbb{R}}^n)$ to $L^{q,{\lambda}}({\mathbb{R}}^n)$ implies that $b{\in}CMO({\mathbb{R}}^n)$ (the closure in $BMO({\mathbb{R}}^n)$of the space of $C^{\infty}({\mathbb{R}}^n)$ functions with compact support). These results together with some previous ones give a new characterization of $BMO({\mathbb{R}}^n)$ functions or $CMO({\mathbb{R}}^n)$ functions in essential ways.

A Study on Disclosure & Utilizing Plan for Closed National R&D Reports Information (비공개 국가연구개발보고서 정보의 공개 및 활성화 방안 연구)

  • Choi, Kwang-Nam;Yoon, Chong-Min
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.45 no.1
    • /
    • pp.233-254
    • /
    • 2011
  • According to the current legislation in Korea, some of national R&D reports cannot be disclosed or registered, when they need external security or the interested parties require them to be classified for a certain period of time. Therefore, there are some effects on the collection and circulation of information about R&D reports. Since those closed national R&D reports are the important outcomes from national R&D projects, they should be properly open, circulated and used by the public, when the reasons for closing those reports are removed. This study examines the present condition of the closure system of national R&D reports, and proposes a plan for collecting and utilizing the closed national R&D reports at the national level.

The Clinical Analysis of Ventricular Septal Defect Review of 97 cases (심실중격결손증의 임상적 고찰)

  • 백광제
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.139-150
    • /
    • 1985
  • From 1977 through 1984, 97 patients of V.S.D. were treated surgically at Department of Thoracic and Cardiovascular Surgery, Korea University college of Medicine. Among 97 patients, 3 patients were treated by PDA ligation, 3 patients were treated by PDA ligation and subclavian flap aortoplasty, 1 patient were treated by pulmonary artery banding. All of the above patients were analyzed clinically. The results were as follows; 1. Of the patients, 52 patients were male [55.5%] and 45 patients were female [44.5%]. Their age ranged from 7 days to 32 year, and the mean age was 9 year of age and 28.9% of patients were between 4 and 8 year of age. 2. The most common clinical symptoms were frequent U.R.l. and D.O.E.. 3. The most common chest PA findings were cardiomegaly and increased pulmonary vascularity. 4. Associated anomaly was founded in 27 cases and PDA was most common associated anomaly and others were A.S.D., pulmonary stenosis, aortic regurgitation, D.C.R.V.. 5. Pulmonary hypertension was founded in 37 patients and it`s incidence was increased by patient age and shunt amount. 6. On Kirklin`s anatomical classification, type 11 defect was most common [45.5%], and type 1 was 35.5%, and type 111 was 4.4%, and type 1V was 4.4%. 7. Mean E.C.C. time was 69.1 min. and varied by closing method and associated anomaly as in case of simple closure; 47.8 min., in case of patch closure; 77.2 min., in cases with associated anomaly; 92.7 min.. 8. Mean postoperative ventilatory assisted time was 7.3 hour and varied by preoperative pulmonary artery pressure and E.C.C. time, as the group with pulmonary hypertension; 10.5 hour, the group without pulmonary hypertension; 5.5 hour, the group of short E.C.C time [within 1 hour]; 4.4 hour, the group of long E.C.C. time [over 1 hour]; 8.4 hour. 9. Overall operative mortality was 9.3% [9 cases].

  • PDF

Efficacy of a Novel Annular Closure Device after Lumbar Discectomy in Korean Patients : A 24-Month Follow-Up of a Randomized Controlled Trial

  • Cho, Pyung Goo;Shin, Dong Ah;Park, Sang Hyuk;Ji, Gyu Yeul
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.6
    • /
    • pp.691-699
    • /
    • 2019
  • Objective : Lumbar discectomy is an effective treatment for lumbar disc herniation (LDH); however, up to 2-18% of patients with LDH have experienced recurrent disc herniation. The purpose of this study was to evaluate the efficacy of a novel annular closure device (ACD) for preventing LDH recurrence and re-operation compared with that of conventional lumbar discectomy (CLD). Methods : In this prospective randomized controlled trial, we compared CLD with discectomy utilizing the $Barricaid^{(R)}$ (Intrinsic Therapeutics, Inc., Woburn, MA, USA) ACD. Primary radiologic outcomes included disc height, percentage of preoperative disc height maintained, and re-herniation rates. Additional clinical outcomes included visual analog scale (VAS) scores for back and leg pain, Oswestry Disability Index (ODI) scores, and 12-item short-form health survey (SF-12) quality of life scores. Outcomes were measured at preoperation and at 1 week, 1, 3, 6, 12, and 24 months postoperation. Results : Sixty patients (30 CLD, 30 ACD) were enrolled in this study. At 24-month follow-up, the disc height in the ACD group was significantly greater than that in the CLD group ($11.4{\pm}1.5$ vs. $10.2{\pm}1.2mm$, p=0.006). Re-herniation occurred in one patient in the ACD group versus six patients in the CLD group (${\chi}^2=4.04$, p=0.044). Back and leg VAS scores, ODI scores, and SF-12 scores improved significantly in both groups compared with preoperative scores in the first 7 days following surgery and remained at significantly improved levels at a 24-month follow-up. However, no statistical difference was found between the two groups. Conclusion : Lumbar discectomy with the $Barricaid^{(R)}$ (Intrinsic Therapeutics, Inc.) ACD is more effective at maintaining disc height and preventing re-herniation compared with conventional discectomy. Our results suggest that adoption of ACD in lumbar discectomy can help improve the treatment outcome.

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.