• Title/Summary/Keyword: quasi-static cyclic test

검색결과 82건 처리시간 0.024초

Study of a self-centering beam-column joint with installed tapered steel plate links

  • Liusheng He;Yangchao Ru;Haifeng Bu;Ming Li
    • Structural Engineering and Mechanics
    • /
    • 제87권4호
    • /
    • pp.391-403
    • /
    • 2023
  • In this study, a new type of self-centering beam-column joint with tapered steel plate links is proposed. Firstly, mechanical property of the basic joint (with the prestressed steel strands only, to provide the self-centering ability) and the combined joint (with both the prestressed steel strands and tapered steel plate links, to provide self-centering and energy dissipation simultaneously) is theoretically analyzed. Then, three joints with different dimensions and combinations of tapered plate links are designed and tested through a series of quasi-static cyclic loading tests. Test results show that a nearly bilinear elastic moment-rotation relationship for the basic joint is obtained. With the addition of tapered steel plate links, typical flag-shape hysteretic curves are obtained, which indicates good self-centering and energy dissipating ability of the combined joint. By installing multiple tapered plate links, stiffness and bearing capacity of the beam-column joint can be enhanced. The theoretical moment-rotation relationships agree well with the test results. A simplified macro model of the proposed joint is developed using OpenSees, which simulates reasonably well its hysteretic behavior.

수평 반복하중을 받는 비내진상세 RC 중공구형교각의 거동특성 (Behavior of Bellow Rectangular RC Piers without Seismic Detailing Subjected to Cyclic Lateral Load)

  • 김재관;김익현;임현우;이재호
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.263-272
    • /
    • 2003
  • 내진상세가 적용되지 않은 RC중공구형단면 교각의 지진 시 거동특성 및 내진성능을 파악하기 위하여 축소모델 실험을 수행하였다. 축소모델은 교각의 소성힌지영역내에 동일한 위치에서 모든 주철근이 겹침이음된 모델과 연속된 철근을 사용하여 겹침이음을 없앤 모델로 설계하였다. 실험은 축력이 재하된 상태에서 준정적 반복하중을 재하하였다. 실험결과 겸침이음모델은 주철근의 겹침이음부에서의 부착파괴가 발생하였지만 비교적 큰 연성거동을 나타냈으며 연속철근을 사용한 모델은 전형적인 휨파괴 특성과 매우 큰 연성거동을 보였다.

Seismic behavior of steel reinforced concrete (SRC) joints with new-type section steel under cyclic loading

  • Wang, Qiuwei;Shi, Qingxuan;Tian, Hehe
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1561-1580
    • /
    • 2015
  • No significant improvement has been observed on the seismic performance of the ordinary steel reinforced concrete (SRC) columns compared with the reinforced concrete (RC) columns mainly because I, H or core cross-shaped steel cannot provide sufficient confinement for core concrete. Two improved SRC columns by constructing with new-type section steel were put forward on this background: a cross-shaped steel whose flanges are in contact with concrete cover by extending the geometry of webs, and a rotated cross-shaped steel whose webs coincide with diagonal line of the column's section. The advantages of new-type SRC columns have been proved theoretically and experimentally, while construction measures and seismic behavior remain unclear when the new-type columns are joined onto SRC beams. Seismic behavior of SRC joints with new-type section steel were experimentally investigated by testing 5 specimens subjected to low reversed cyclic loading, mainly including the failure patterns, hysteretic loops, skeleton curves, energy dissipation capacity, strength and stiffness degradation and ductility. Effects of steel shape, load angel and construction measures on seismic behavior of joints were also analyzed. The test results indicate that the new-type joints display shear failure pattern under seismic loading, and steel and concrete of core region could bear larger load and tend to be stable although the specimens are close to failure. The hysteretic curves of new-type joints are plumper whose equivalent viscous damping coefficients and ductility factors are over 0.38 and 3.2 respectively, and this illustrates the energy dissipation capacity and deformation ability of new-type SRC joints are better than that of ordinary ones with shear failure. Bearing capacity and ductility of new-type joints are superior when the diagonal cross-shaped steel is contained and beams are orthogonal to columns, and the two construction measures proposed have little effect on the seismic behavior of joints.

콘크리트 충전 강교각의 내진 성능 평가 (The Evaluation of Seismic Performance for Concrete-filled Steel Piers)

  • 정지만;장승필;인성빈
    • 한국지진공학회논문집
    • /
    • 제6권5호
    • /
    • pp.53-58
    • /
    • 2002
  • 최근, 콘크리트 충전 강교각은 신속한 시공과 뛰어난 연성능력으로 인해 도심지에서 철근 콘크리트 교각의 대안이 되고 있다. 이러한 콘크리트 충전 강교각은 내진 설계에서도 훌륭한 성능을 발휘할 수 있으나 내진 설계의 가이드가 없어 내진 설계시 그 성능을 모두 반영하지 못하고 있는 상황이다. 이에 실제 적용을 위해 콘크리트 충전 강교각 실험으로부터 얻어진 실험치로부터 내진 설계에 지침이 될 수 있는 가이드를 제시하고자 한다. 콘크리트 충전 강교각과 일반 강교각의 연성 능력을 평가하기 위해 준 정적 반복 재하 실험을 수행하고, 지진 거동을 검증하기 위해 고베 지진을 입력 데이타로 한 유사 동적 실험을 수행한다. 콘크리트 충전 강교각은 일반 강교각에 비해 만족할 만한 연성도와 강도를 보이고, 동적 거동은 상대적으로 큰 이력감쇠를 증명한다. 실험으로 얻어진 데이터를 근거로 하여 콘크리트 충전 강교각의 내진 성능을 정량화 하고, 탄성응답 스펙트럼에 의한 지진응답 수정계수법과 유효 점성 감쇠를 이용한 성능 곡선 및 요구 스펙트럼에 의한 성능기초 설계법의 비교를 통하여, 콘크리트 충전 강교각과 일반 강교각의 내진 성능을 평가한다. 이러한 내진 성능 평가를 기초로 하여, 일반 강교각과 더불어 내진 설계에 적용할 수 있는 콘크리트 충전 강교각의 지진응답 수정계수를 제시한다.

응력연화와 잔류변형을 고려한 복합화약 시뮬런트의 구성방정식연구 (A Constitutive Model for Polymer-Bonded Explosive Simulants Considering Stress Softening and Residual Strain)

  • 염기선;허훈;박정수
    • 한국군사과학기술학회지
    • /
    • 제17권6호
    • /
    • pp.844-852
    • /
    • 2014
  • PBX simulant is known to exhibit highly nonlinear behaviors of deformation such as the stress softening, hysteresis under cyclic loading, residual strain after unloading, and aging. This paper proposes a new pseudo-elastic model for PBX simulant considering stress softening and residual strain. Uniaxial loading and unloading tests at quasi-static states were carried out in order to obtain the mechanical properties of the PBX simulants. And then the Dorfmann-Ogden model is modified to make it consistent with the test result of PBX simulants. Prediction with the new model shows a good correspondence to the experimental data demonstrating that the model properly describes stress softening and residual strain of PBX simulants.

원주방향균열이 존재하는 원전 배관계통의 파괴거동에 관한 실험적 연구(I) - 직관부에서의 균열거동 평가 - (An Experimental Study on the Fracture Behavior of Nuclear Piping System with a Circumferential Crack(I) - Estimation of Crack Behavior in Straight Piping -)

  • 최영환;박윤원
    • 대한기계학회논문집A
    • /
    • 제23권7호
    • /
    • pp.1182-1195
    • /
    • 1999
  • The purpose of this study is to investigate experimentally the effects of both seismic loading and crack length on the fracture behavior of piping system with a circumferential crack in nuclear power plants. The experiments were performed using both large scale piping system facility and 4 points bending test machine under PWR operating conditions. The difference in the load carrying capacities between cracked piping and non-cracked piping was also investigated using the results from experiments and numerical calculations. The results obtained from the experiments and estimation are as follows : (1) The safety margin under seismic loading is larger than those under quasi static loading or simple cyclic loading. (2) There was no significant effect of crack length on tincture behavior of piping system with both a surface crack and a through-wall crack. (3) The load carrying capacity in cracked piping was reduced by factors of 7 to 46 compared to non-cracked piping.

Numerical simulation of an adobe wall under in-plane loading

  • Nicola, Tarque;Guido, Camata;Humberto, Varum;Enrico, Spacone;Marcial, Blondet
    • Earthquakes and Structures
    • /
    • 제6권6호
    • /
    • pp.627-646
    • /
    • 2014
  • Adobe is one of the oldest construction materials that is still used in many seismic countries, and different construction techniques are found around the world. The adobe material is characterized as a brittle material; it has acceptable compression strength but it has poor performance under tensile and shear loading conditions. Numerical modelling is an alternative approach for studying the nonlinear behaviour of masonry structures such as adobe. The lack of a comprehensive experimental database on the adobe material properties motivated the study developed here. A set of a reference material parameters for the adobe were obtained from a calibration of numerical models based on a quasi-static cyclic in-plane test on full-scale adobe wall representative of the typical Peruvian adobe constructions. The numerical modelling, within the micro and macro modelling approach, lead to a good prediction of the in-plane seismic capacity and of the damage evolution in the adobe wall considered.

The effects of special metallic dampers on the seismic behavior of a vulnerable RC frame

  • Ozkaynak, Hasan
    • Structural Engineering and Mechanics
    • /
    • 제61권4호
    • /
    • pp.483-496
    • /
    • 2017
  • Earthquake excitations may induce important amount of seismic energy into structures. Current design philosophy mainly deals with the plastic deformations of replaceable energy dissipating devices rather than damages accumulated on structural members. Since earthquake damage is substantially concentrated on these devices they could be replaced after severe earthquakes. In this study, the efficiency of steel cushion (SC) on seismic improvement of a vulnerable reinforced concrete (RC) frame is determined by means of several numerical simulations. The cyclic shear behaviors of SCs were determined by performing quasi-static tests. The test results were the main basis of the theoretical model of SCs which were used in the numerical analysis. These analyses were performed on three types of RC frames namely bare frame (BF), full-braced frame (F-BF) and semi-braced frame (S-BF). According to analysis results; implementation of SCs has considerable effects in reducing the storey shear forces and storey drifts. Moreover plastic energy demands of structural elements were reduced which indicates a significant improvement in seismic behavior of the RC frame preventing damage accumulation on structural elements. Full-braced frame having SCs with the thickness of 25 mm has better performance than semi-braced frame interms of energy dissipation. However, global energy dissipation demand of S-BF and F-BF having SCs with the thickness of 18 mm are almost similar.

Cyclic testing of a new visco-plastic damper subjected to harmonic and quasi-static loading

  • Modhej, Ahmad;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • 제81권3호
    • /
    • pp.317-333
    • /
    • 2022
  • Visco-Plastic Damper (VPD) as a passive energy dissipation device with dual behavior has been recently numerically studied. It consists of two bent steel plates and segments with a viscoelastic solid material in between, combining and improving characteristics of both displacement-dependent and velocity-dependent devices. In order to trust the performance of VPD, for the 1st time this paper experimentally investigates prototype damper behavior under a wide range of frequency and amplitude of dynamic loading. A high-axial damping rubber is innovatively proposed as the viscoelastic layer designed to withstand large axial strains and dissipate energy accordingly. Test results confirmed all assumptions about VPD. The behavior of VPD subjected to low levels of excitation is elastic while with increasing levels of excitation, a significant source of energy dissipation is provided through the yielding of the steel elements in addition to the viscoelastic energy dissipation. The results showed energy dissipation of 99.35 kN.m under a dynamic displacement with 14.095 mm amplitude and 0.333 Hz frequency. Lateral displacement at the middle of the device was created with an amplification factor obtained ranging from 2.108 to 3.242 in the rubber block. Therefore, the energy dissipation of viscoelastic material of VPD was calculated 18.6 times that of the ordinary viscoelastic damper.

Ductile capacity study of buckling-restrained braced steel frame with rotational connections

  • Mingming Jia;Jinzhou He;Dagang Lu
    • Steel and Composite Structures
    • /
    • 제46권3호
    • /
    • pp.417-433
    • /
    • 2023
  • The maximum ductility and cumulative ductility of connection joints of Buckling-Restrained Braced Frames (BRBF) are critical to the structural overall performance, which should be matched with the BRB ductility. The two-story and one-span BRBF with a one-third scale was tested under cyclic quasi-static loading, and the top-flange beam splice (TFBS) rotational connections were proposed and adopted in BRBF. The deformation capacity of TFBS connections was observed during the test, and the relationship between structural global ductility and local connection ductility was studied. The rotational capacity of the beam-column connections and the stability performance of the BRBs are highly relevant to the structural overall performance. The hysteretic curves of BRBF are stable and full under large displacement demand imposed up to 2% story drift, and energy is dissipated as the large plastic deformation developed in the structural components. The BRBs acted as fuses and yielded first, and the cumulative plastic ductility (CPD) of BRBs is 972.6 of the second floor and 439.7 of the first floor, indicating the excellent energy dissipation capacity of BRBs. Structural members with good local ductility ensure the large global ductility of BRBF. The ductile capacity and hysteretic behavior of BRBF with TFBS connections were compared with those of BRBF with Reduced Beam Section (RBS) connections in terms of the experimental results.