• Title/Summary/Keyword: quantitative test

Search Result 2,292, Processing Time 0.031 seconds

Quantitative Risk Analysis of a Pervaporation Process for Concentrating Hydrogen Peroxide (과산화수소 농축을 위한 투과증발공정의 정량적 위험성 분석)

  • Jung, Ho Jin;Yoon, Ik Keun;Choi, Soo Hyoung
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.750-754
    • /
    • 2014
  • Quantitative risk analysis has been performed for a pervaporation process for production of high test peroxide. Potential main accidents are explosion and fire caused by a decomposition reaction. As the target process has a laboratory scale, the consequence is considered to belong to Category 3. An event tree has been developed as a model for occurrence of a decomposition reaction in the target process. The probability functions of the accident causes have been established based on the frequency data of similar events. Using the constructed model, the failure rate has been calculated. The result indicates that additional safety devices are required in order to achieve an acceptable risk level, i.e. an accident frequency less than $10^{-4}/yr$. Therefore, a layer of protection analysis has been applied. As a result, it is suggested to introduce inherently safer design to avoid catalytic reaction, a safety instrumented function to prevent overheating, and a relief system that prevents explosion even if a decomposition reaction occurs. The proposed method is expected to contribute to developing safety management systems for various chemical processes including concentration of hydrogen peroxide.

Quantitative Method of Rapid Immunochromatographic Assay Kit for HBsAg-screening using Computer Image Analysis (컴퓨터 상 분석을 이용한 HBsAg-screening용 Rapid Immunochromatographic Assay Kit의 정량적 측정법)

  • 신형순;허태련
    • KSBB Journal
    • /
    • v.15 no.3
    • /
    • pp.243-246
    • /
    • 2000
  • One of recent topics in the case of hepatits B virus(HVB) is the value of hepatitis B surface antigen(HBsAg) concentration as a prognostic maker. We developed uantitative method of rapid immunochromatographic assay(ICA) kit for HBsAg using computer image analysis (CIA) for the purpose of home diagnosis. uantitative ICA using CIA demonstrated integrated optical density(IOD) values proportional to log of reference HBsAg concentrations in the range of 2-200 ng/mL and enzyme-linked immunosorbent assay(ELISA) demonstrated the same in the range of 0.1-100 ng/mL however the test results with sample sear showed the same concentration on both kits. Furthermore repeated tests with the same samples revealed that this quantitative ICA using CIA would be reproducible and coefficient of variation(CV) of the results was 1.38~6.30%.

  • PDF

Comparison of Methods for Measuring Histamine by ELISA and HPLC-MS Assay In Vitro (In Vitro에서 히스타민 측정 시 ELISA법과 HPLC-MS 분석법의 비교)

  • Lee, In Hee;Kim, Yoo Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.306-312
    • /
    • 2015
  • The measurement of histamine is to determine the degree of allergy because the allergic reaction can lead to the release of histamine. In general, the antigen-antibody reaction was quantified by measuring absorbance using a microplate reader. In this study, we compare the method using a general antigen-antibody reaction and the method using a high performance liquid chromatography mass spectrometer (HPLC-MS) of chemical analysis in the measurement of histamine secretion. The cell line used was RBL-2H3, an allergic reaction was induced by stimulation with C48/80 (compound 48/80). Allergy-induced cells degranulation rate was confirmed by measurement of ${\beta}$-hexosaminidase and cytotoxicity was performed for the validity of the experiment. The quantitative determination of histamine showed a significant difference, since the quantitative limit of the measurement by the antigen-antibody reaction was 10.257 ppm while the quantitative limit of the measurement by HPLC-MS was 0.020 ppm. Measurement of histamine in allergic activity and anti-allergy tests showed that the HPLC-MS analysis rather than the analysis of the antigen-antibody reaction is a more precise and accurate test.

Estimation of Quantitative Source Contribution of Ambient PM-10 Using the PMF Model (PMF모델을 이용한 대기 중 PM-10 오염원의 정량적 기여도 추정)

  • 황인조;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.719-731
    • /
    • 2003
  • In order to maintain and manage ambient air quality, it is necessary to identify sources and to apportion its sources for ambient particulate matters. The receptor methods were one of the statistical methods to achieve reasonable air pollution strategies. Also, receptor methods, a field of chemometrics, is based on manifold applied statistics and is a statistical methodology that analyzes the physicochemical properties of gaseous and particulate pollutant on various atmospheric receptors, identifies the sources of air pollutants, and quantifies the apportionment of the sources to the receptors. The objective of this study was 1) after obtaining results from the PMF modeling, the existing sources of air at the study area were qualitatively identified and the contributions of each source were quantitatively estimated as well. 2) finally efficient air pollution management and control strategies of each source were suggested. The PMF model was intensively applied to estimate the quantitative contribution of air pollution sources based on the chemical information (128 samples and 25 chemical species). Through a case study of the PMF modeling for the PM-10 aerosols, the total of 11 factors were determined. The multiple linear regression analysis between the observed PM-10 mass concentration and the estimated G matrix had been performed following the FPEAK test. Finally the regression analysis provided quantitative source contributions (scaled G matrix) and source profiles (scaled F matrix). The results of the PMF modeling showed that the sources were apportioned by secondary aerosol related source 28.8 %, soil related source 16.8%, waste incineration source 11.5%, field burning source 11.0%, fossil fuel combustion source 10%, industry related source 8.3%, motor vehicle source 7.9%, oil/coal combustion source 4.4%, non-ferrous metal source 0.3%. and aged sea- salt source 0.2%, respectively.

Localization of Broca's Area Using Functional MR Imaging: Quantitative Evaluation of Paradigms

  • Kim, Chi-Heon;Kim, Jae-Hun;Chung, Chun-Kee;Kim, June-Sic;Lee, Jong-Min;Lee, Sang-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.219-223
    • /
    • 2009
  • Objective : Functional magnetic resonance imaging (fMRI) is frequently used to localize language areas in a non-invasive manner. Various paradigms for presurgical localization of language areas have been developed, but a systematic quantitative evaluation of the efficiency of those paradigms has not been performed. In the present study, the authors analyzed different language paradigms to see which paradigm is most efficient in localizing frontal language areas. Methods : Five men and five women with no neurological deficits participated (mean age, 24 years) in this study. All volunteers were right-handed. Each subject performed 4 tasks, including fixation (Fix), sentence reading (SRI. pseudoword reading (PR), and word generation (WG). Fixation and pseudoword reading were used as contrasts. The functional area was defined as the area(s) with a t-value of more than 3.92 in fMRI with different tasks. To apply an anatomical constraint, we used a brain atlas mapping system, which is available in AFNI, to define the anatomical frontal language area. The numbers of voxels in overlapped area between anatomical and functional area were individually counted in the frontal expressive language area. Results : Of the various combinations, the word generation task was most effective in delineating the frontal expressive language area when fixation was used as a contrast (p<0.05). The sensitivity of this test for localizing Broca's area was 81 % and specificity was 70%. Conclusion : Word generation versus fixation could effectively and reliably delineate the frontal language area. A customized effective paradigm should be analyzed in order to evaluate various language functions.

Methods for quantitative measurement of tooth wear using the area and volume of virtual model cusps

  • Kim, Soo-Hyun;Park, Young-Seok;Kim, Min-Kyoung;Kim, Sulhee;Lee, Seung-Pyo
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.2
    • /
    • pp.124-134
    • /
    • 2018
  • Purpose: Clinicians must examine tooth wear to make a proper diagnosis. However, qualitative methosds of measuring tooth wear have many disadvantages. Therefore, this study aimed to develop and evaluate quantitative parameters using the cusp area and volume of virtual dental models. Methods: The subjects of this study were the same virtual models that were used in our former study. The same age group classification and new tooth wear index (NTWI) scoring system were also reused. A virtual occlusal plane was generated with the highest cusp points and lowered vertically from 0.2 to 0.8 mm to create offset planes. The area and volume of each cusp was then measured and added together. In addition to the former analysis, the differential features of each cusp were analyzed. Results: The scores of the new parameters differentiated the age and NTWI groups better than those analyzed in the former study. The Spearman ${\rho}$ coefficients between the total area and the area of each cusp also showed higher scores at the levels of 0.6 mm (0.6A) and 0.8A. The mesiolingual cusp (MLC) showed a statistically significant difference (P<0.01) from the other cusps in the paired t-test. Additionally, the MLC exhibited the highest percentage of change at 0.6A in some age and NTWI groups. Regarding the age groups, the MLC showed the highest score in groups 1 and 2. For the NTWI groups, the MLC was not significantly different in groups 3 and 4. These results support the proposal that the lingual cusp exhibits rapid wear because it serves as a functional cusp. Conclusions: Although this study has limitations due to its cross-sectional nature, it suggests better quantitative parameters and analytical tools for the characteristics of cusp wear.

Validation of Electrical Impedance Tomography Qualitative and Quantitative Values and Comparison of the Numeric Pain Distress Score against Mammography

  • Juliana, Norsham;Shahar, Suzana;Chelliah, Kanaga Kumari;Ghazali, Ahmad Rohi;Osman, Fazilah;Sahar, Mohd Azmani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5759-5765
    • /
    • 2014
  • Electrical impedance tomography (EIT) is a potential supplement for mammogram screening. This study aimed to evaluate and feasibility of EIT as opposed to mammography and to determine pain perception with both imaging methods. Women undergoing screening mammography at the Radiology Department of National University of Malaysia Medical Centre were randomly selected for EIT imaging. All women were requested to give a pain score after each imaging session. Two independent raters were chosen to define the image findings of EIT. A total of 164 women in the age range from 40 to 65-year-old participated and were divided into two groups; normal and abnormal. EIT sensitivity and specificity for rater 1 were 69.4% and 63.3, whereas for rater 2 they were 55.3% and 57.0% respectively. The reliability for each rater ranged between good to very good (p<0.05). Quantitative values of EIT showed there were significant differences in all values between groups (ANCOVA, p<0.05). Interestingly, EIT scored a median pain score of $1.51{\pm}0.75$ whereas mammography scored $4.15{\pm}0.87$ (Mann Whitney U test, p<0.05). From these quantitative values, EIT has the potential as a health discriminating index. Its ability to replace image findings from mammography needs further investigation.

Isolation and Quantitative Analysis of Cinnamtannin B-1 from Osmunda japonica Thunb (고비로부터 Cinnamtannin B-1의 분리 및 함량 분석)

  • Kim, Min Suk;Woo, Kyeong Wan;Lee, Ki Ho;Lee, Hyun Joo;Lee, Seon Yu;Kang, Byoung Man;Jeon, Byung Hun;Cho, Jung Hee;Cho, Hyun Woo
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.3
    • /
    • pp.232-236
    • /
    • 2016
  • In traditional Korean medicine, Osmunda japonica Thunb has been used as hemostasis and antipyretic treatment. The main compound "cinnamtannin B-1" was obtained by column chromatographic separation, and its structure was determined by spectroscopic methods, including $^1H$, $^{13}C$ NMR, and IT-TOF-ESI MS. Ash, moisture and extract content and acidinsoluble ash were monitored as identification test to establish the analytical methods. The optimum reflux extraction condition was 100% methanol extracted 30 min for 2 times. A quantitative analysis using HPLC method exhibited that the main compound at 24.7 min and its content was 0.96% in methanol extraction.

Quantitative assessment of periimplant bone density (HU) on CBCT image (CBCT 영상에서 무치악부 임프란트 매식체 주위골 골밀도(HU)의 정량적 평가)

  • Goo, Jong-Gook;Kim, Jin-Soo;Kim, Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Purpose: The primary aims of this retrospective study were to compare subjective bone quality and bone quality based on the Hounsfield scale in different segments of the edentulous jaw, and to establish quantitative and objective assessment of the bone quality. Materials and Methods: Twenty eight randomly selected cone-beam computed tomographic (CBCT) scans were analyzed. For evaluation one hundred and twelve edentulous areas were selected. Implant recipient sites were evaluated visually for Lekholm and Zarb classification. The same sites were subsequently evaluated digitally using the Hounsfield scale with Vimplant$2.0^{TM}$, and the results were correlated with visual classification. Data was subject for statistical analysis in order to determine correlation between recorded HU and the regions of the mouth with the Kruskal-Wallis test. Results: The highest unit/mean density value (311 HU) was found in the anterior mandible, followed by 259 HU for the posterior mandible, 216 HU for the anterior maxilla, and 127 HU for the posterior maxilla. These results demonstrate a strong correlation for HU depending on the region of the mouth (p<0.001). The relationship between HU and type 4 bone was found to be significant (r=0.74). Conclusion: Knowledge of the Hounsfield value as a quantitative measurement of bone density can be helpful as a diagnostic tool by using $CBMercuRa6^{TM}$ with $Vimplant^{TM}$ software.

  • PDF

Effect of biofilm formation, and biocorrosion on denture base fractures

  • Sahin, Cem;Ergin, Alper;Ayyildiz, Simel;Cosgun, Erdal;Uzun, Gulay
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.140-146
    • /
    • 2013
  • PURPOSE. The aim of this study was to investigate the destructive effects of biofilm formation and/or biocorrosive activity of 6 different oral microorganisms. MATERIALS AND METHODS. Three different heat polymerized acrylic resins (Ivocap Plus, Lucitone 550, QC 20) were used to prepare three different types of samples. Type "A" samples with "V" type notch was used to measure the fracture strength, "B" type to evaluate the surfaces with scanning electron microscopy and "C" type for quantitative biofilm assay. Development and calculation of biofilm covered surfaces on denture base materials were accomplished by SEM and quantitative biofilm assay. According to normality assumptions ANOVA or Kruskal-Wallis was selected for statistical analysis (${\alpha}$=0.05). RESULTS. Significant differences were obtained among the adhesion potential of 6 different microorganisms and there were significant differences among their adhesion onto 3 different denture base materials. Compared to the control groups after contamination with the microorganisms, the three point bending test values of denture base materials decreased significantly (P<.05); microorganisms diffused at least 52% of the denture base surface. The highest median quantitative biofilm value within all the denture base materials was obtained with P. aeruginosa on Lucitone 550. The type of denture base material did not alter the diffusion potential of the microorganisms significantly (P>.05). CONCLUSION. All the tested microorganisms had destructive effect over the structure and composition of the denture base materials.