• 제목/요약/키워드: quantitative image analysis

검색결과 756건 처리시간 0.065초

이미지 분석을 이용한 경량골재 콘크리트의 골재분포 판정기법 개발 (The Evaluation Model of Aggregate Distribution for Lightweight Concrete Using Image Analysis Method)

  • 지석원
    • 대한건축학회논문집:구조계
    • /
    • 제34권10호
    • /
    • pp.11-18
    • /
    • 2018
  • In this study, the cross-sectional image has been acquired to evaluate the aggregate distribution affecting quality of lightweight aggregate concrete, and through the binarization method, the study is to calculate the aggregate area of upper and lower sections to develop the method to assess the aggregate distribution of concrete. The acquisition of cross-section image of concrete for the above was available from the cross-sectional photography of cleavage tension of a normal test specimen, and an easily accessible and convenient image analysis software was used for image analysis. As a result, through such image analyses, the proportion of aggregate distribution of upper and lower sections of the test specien could be calculated, and the proportion of aggregate area U/L value of the upper and lower regions of concrete cross-section was calculated, revealing that it could be used as the comprehensive index of aggregate distribution. Moreover, through such method, relatively easy image acquisition methods and analytic methods have been proposed, and this indicated that the development of modeling to assess aggregate distribution quantitatively is available. Based on these methods, it is expected that the extraction of fundamental data to reconsider the connectivity with processes in concrete will be available through quality assessment of quantitative concrete.

프랙탈 이론에 기초한 섬유보강시멘트 복합체의 균열패턴의 정량분석 (Quantitative Analysis of Crack Patterns of Fiber Reinforced Cement Composites based on Fractal)

  • 원종필;김성애
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.333-338
    • /
    • 2001
  • Fractal geometry is a non-Euclidean geometry which has been developed to quantitative analysis irregular or fractional shapes. Fractal dimension of irregular surface has fractal values ranging from 2 to 3 and of irregular line profile has fractal values ranging from 1 to 2. In this paper, quantitative analysis of crack growth patterns during the fracture processing of fiber-reinforced cement composites based on fractal geometry. The fracture behaviors of fiber reinforced mortar beams subjected to three-point loading in flexure. The beams all had a single notch depth, but varing volume fractions of polypropylene, cellulose fibers. The crack growth behaviors, as observed through the image processing system, and the box counting method was used to determine the fractal dimension, Df. The results showed that the linear correlation exists between fractal dimension and fracture energy of the fiber reinforced cement mortar.

  • PDF

랫드의 신경조직에 미치는 Tellurium의 독성에 관한 연구 (A Study on the Neurotoxic Effects of Tellurium on Murine Nervous System)

  • 김기석;정문호
    • 한국환경보건학회지
    • /
    • 제24권3호
    • /
    • pp.35-40
    • /
    • 1998
  • This study was conducted to examine the pathological changes of rat peripheral nervous system during exposure to tellurium known to be a demyelinating agent by using teasing nerve fiber method and quantitative light microscopic analysis by image analyzer. The pellet containing 1.2% of tellurium were fed for 3, 5, 7, 9, 13 days to male wistar rats (21 days old) and then neurologic symptom and the feature of nerve fiber myelination were studied. From this study, following results were obtained. In 3 days treated group, it showed various neurologic symptom and teased nerve fiber showed slight irregularity of the myeline sheath. In 5 days and 7 days treated groups, it showed the segmental demyetination in larger size fiber and widening of nodes of ranvier. In 9 days and 13 days treated groups, the remyelinated fibers were observed and it was generally small in size. We consequently suggest that teasing nerve fiber method and quantitative analysis of nerve fiber were useful pathologic screening method of neurotoxicity of the peripheral nervous system.

  • PDF

IC-패키지에 대한 각종 디지탈 화상처리 기술의 적용방법에 대한 연구 (A Study on the Application Method of Various Digital Image Processing in the IC Package)

  • 김재열
    • 비파괴검사학회지
    • /
    • 제12권4호
    • /
    • pp.18-25
    • /
    • 1993
  • This paper is to aim the microdefect evaluation of If package into a quantitative from NDI's image processing of ultrasonic wave. (1) Automatically repeated discrimination analysis method can be devided in the category of all kind of defects on IC package, and also can be possible to have a sampling of partial delamination. (2) It is possible that the information of edge section in silicon chip surrounding can be extractor by the partial image processing of IC package. Also, the crack detection is possible between the resin part and lead frame.

  • PDF

디지탈 혈관 조영 장치의 영상기술 응용에 관한 연구 (A study on the applications of the digital subtraction angiography imaging technique)

  • 남문현;김성룡
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.684-689
    • /
    • 1987
  • Digital Subtraction Angiography(DSA) technique has been widely used to detect vascular diseases and hemodynamic parameters noninvasively. However, there are few quantitative studies on the factors in fluencing the resultant DSA image quality. In this paper, several important factors are suggested to improved the DSA image quality based on mathematical analysis. Experimental DSA images for different filters are shown and also discussed the difference between original and processed image quality.

  • PDF

무선조정 헬리콥터 사진측량시스템을 이용한 절취사면 정보 추출 (Extraction of Information on Road Cutting Slope using RC Helicopter Photographic Surveying System)

  • 이종출;이영도;김진수;조용재
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 추계학술발표회 논문집
    • /
    • pp.217-222
    • /
    • 2004
  • In this study, cutting slope's digital image has acquired by using video camera attached at RC helicopter. Resulted RMSE from image processing was approximately x-direction 0.27m, y-direction 0.23m and z-direction 0.35m. Application of these methods makes it convenient that acquisition of digital image about before and after the construction work of road cutting slope. Also systematical cutting slope's information acquisition will be possible by cutting slope's quantitative and qualitative analysis.

  • PDF

PIV 법을 이용한 기포유동에 관한 연구 (A Study on Bubbly Flow using PIV Measurement)

  • 배대석;권오봉
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권4호
    • /
    • pp.898-903
    • /
    • 2001
  • The particle image velocimetry with liquid crystal tracers is used for visualizing and analysis of the bubbly flow in a vertical temperature gradient. This method allows simultaneous measurement of velocity and temperature field at a given instant of time Quantitative data of velocity were obtained by applying the MQD technique to visualized image. The paper describes the method, and presents the transient velocity patterns of bubbly flow.

  • PDF

감성 척도 맵 개발 및 패션 브랜드의 감성이미지 비교 연구 - 브랜드 이미지와 브랜드 웹사이트 배색 이미지를 중심으로 - (Development of the Emotional Scale Map and Comparison of Emotional Scale between Fashion Brand Image and Brand Website Coloration Image)

  • 유지현
    • 복식문화연구
    • /
    • 제18권2호
    • /
    • pp.348-370
    • /
    • 2010
  • The purpose of this study was to propose some plan which could satisfy consumer's expectation emotional needs by comparing emotional scale between fashion brand image and brand website coloration image. For this study, 12 brand websites within four fashion zone, men's clothing, women's clothing, casual wear, and sports wear were chosen. The questionnaires were comprised of 27 emotional adjectives which were selected from previous studies. The questionnaires were distributed to university students and office workers for 3 to 17 on September. Among them, 118 questionnaires were analyzed by SPSS tool. The qualitative analysis for emotional adjective sorting, content analysis for website color chip sorting, and quantitative analysis for consumers were used in this study. Some differences exist between brand image and website coloration band image as the result. As the numbers of internet user became larger, the costumer's emotional image which gives maximum satisfaction is getting more important in fashion brand website. Therefore, fashion website managers should satisfy consumers with functional and emotional needs.

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF