• 제목/요약/키워드: quantitation

검색결과 628건 처리시간 0.039초

핵의학 영상과 추적자 동력학 분석법을 이용한 생체기능 정량화 (Quantitation of In-Vivo Physiological Function using Nuclear Medicine Imaging and Tracer Kinetic Analysis Methods)

  • 김수진;김경민;이재성
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.145-152
    • /
    • 2008
  • Nuclear medicine imaging has an unique advantage of absolute quantitation of radioactivity concentration in body. Tracer kinetic analysis has been known as an useful investigation methods in quantitative study of in-vivo physiological function. The use of nuclear medicine imaging and kinetic analysis together can provide more useful and powerful intuition in understanding biochemical and molecular phenomena in body. There have been many development and improvement in kinetic analysis methodologies, but the conventional basic concept of kinetic analysis is still essential and required for further advanced study using new radiopharmaceuticals and hybrid molecular imaging techniques. In this paper, the basic theory of kinetic analysis and imaging techniques for suppressing noise were summarized.

QUANTITATION OF OXANDROLONE(A SYNTHETIC ANABOLIC STEROID) IN HUMAN URINE BY GC/MS

  • Park, Jongsei;Ohseung Kwon;Hea-Young P. Choo;Jawon Suh
    • Toxicological Research
    • /
    • 제4권2호
    • /
    • pp.117-129
    • /
    • 1988
  • A sensitive method for the quantitation of oxandrolone in urine was developed using GC/MS. After oral administration of 10mg oxandrolone, oxandrolone excreted in urine as unchanged form was extracted in ether and derivatized to its O-TMS. Oxandrolone excreted in urine as glucuronide conjugated form was extracted after enzymatic hydrolysis and derivatized to its O-TMS. The amounts of oxandrolone-O-TMS was measured in GC/MS with selected ion monitoring. Calusterone, a structurally similar anabolic steroid, was employed as internal standard.

  • PDF

Detection and Quantitation of Residual Antibiotics and Antibacterial Agents in Foods

  • Ryu, Jae-Chun;Seo, Ja-Won;Song, Yun-Seon;Park, Jong-Sei
    • 한국식품위생안전성학회지
    • /
    • 제5권3호
    • /
    • pp.159-164
    • /
    • 1990
  • To detect and quantitation residual antibiotics and antibacterial agents in meats, we performed a biological assay employing the three microorganisms Bacillus subtilis ATCC 6633, Micrococcus luteus ATCC 9341, and Bacillus cereus var. mycoides ATCC 11778 for the screening purpose and developed a Gas Chromatography-mass Spectrometry(GC/MS) analysis for the confirmation and quantiation. In the biological assay (paper disk method), three test solution are used depending on the character of the residual antibiotics and antibacterial agents, follow by a simple clean up procedure which includes homogenization with Mcilvaine buffer, defatting with includes homogenization with Mcilvaine buffer, defatting with hexane, extraction with chloroform, clean-up by Sep-Pak $C_{18}$ and Bakerbond SPE carboxylic acid column. The chloroform layer is used for the analysis of sulfa agents. macrolides antibiotics and antibacterial agents, Adsorbed materials in the Sep-Pak $C_{18}$ were also employed for th analysis of penicillins and tetracyclines. Effluents from the Sep-Pak $C_{18}$ were cleaned-up one more by Bakerbond 10 SPE COOH column and employed for the analysis of aminoglycosides. In the instrumental analysis by using the GC/MSD, residual antibiotics and antibacterial agent were quantitated by selected ion monitoring (SIM) mode after derivatization. A simultaneous analysis of six residual antibiotic and antibacterial agent such as oxytetracycline, penicillin, ampicillin, choliraphenicol and thiamphenicol was developed with simple cleanup procedures revealing good recovery and reproducibility. Also, simultaneous detection of macrolides antibiotics such as erythromycin, spiramycin, and oleandomycin was developed after acid hydrolysis due to their large molecular structures. Because of the high reproducibility and selectivity of these two methods, it is very desirable that the combination of the two methods be used in the bioassay for the screening of residual antibiotics and antibacterial agent and that GC/MSD analysis be used for the confirmation and quantitation.

  • PDF

방사성동위원소 심혈관촬영술을 이용한 우-좌단락의 정량화에 관한 연구 (Quantitation of Intracardiac Right-to-Left Shunt by Radionuclide Angiocardiography)

  • 범희승;임상무;오연상;김병태;정준기;이명철;고창순;이영우;윤용수;홍창의
    • 대한핵의학회지
    • /
    • 제20권2호
    • /
    • pp.47-52
    • /
    • 1986
  • A noninvasive procedure for diagnosis and quantitation of right-to-left intracardiac shunts will enhance the management of patients with cyanotic congenital heart disease. This study describes an application of radionuclide (RN) angiocardiography for quantitation of right-to-left shunt amount. Gamma variate model was fitted to radionuclide data recorded over the carotid artery. Data analysis was performed retrospectively in 35 patients who underwent cardiac catheterization within a week from the day of RN angiocardiography. Thirty one of the patient had right-to-left shunts and 4 of them had left-to-right shunts. Both the radionuclide and Fick measurements correlated well (r=0.93, 0.93, 0.89, p<0.01 in each measurements). Therefore, RN angiocardiography data may be used for accurate calculation of right-to-left shunts in cyanotic congenital heart disease patients.

  • PDF

HPLC-UVD를 이용한 수련(Nymphaea tetragona Georgi)의 Ellagic Acid 정량 분석 (Quantitative Analysis of Ellagic Acid in Nymphaea tetragona Georgi Root by HPLC-UVD)

  • 이동영;정은주;전병주;성상현
    • 생약학회지
    • /
    • 제45권1호
    • /
    • pp.84-87
    • /
    • 2014
  • A high performance liquid chromatography (HPLC) method for the quantitation of ellagic acid in Nymphaea tetragona was developed for the quality control of functional cosmetic ingredient, the extract of N. tetragona. Separation and quantitation were successfully achieved with a Kromasil C18 column ($5{\mu}m$, $250mm{\times}4.6mm$, i.d.) by isocratic elution of a mixture of acetonitrile containing 0.1% trifluoroacetic acid and water containing 0.03% phosphoric acid at a flow rate of 1.0 ml/min. The UV detector was used for the detection and the wavelength for quantitation was set at 254 nm. The presence of ellagic acid in the extract was determined by comparison of retention time and spiking with authentic standard. Analytical results showed good linearity ($R^2=0.99996$) in relatively wide concentration ranges. The R.S.D. for precision test was less than 3.0%. Recovery of the compound was 98.55~101.72% with R.S.D values less than 4.0%. In conclusion, this method has been successfully applied to the determination of ellagic acid in N. tetragona.

Quantitative Proteomics Towards Understanding Life and Environment

  • Choi, Jong-Soon;Chung, Keun-Yook;Woo, Sun-Hee
    • 한국환경농학회지
    • /
    • 제25권4호
    • /
    • pp.371-381
    • /
    • 2006
  • New proteomic techniques have been pioneered extensively in recent years, enabling the high-throughput and systematic analyses of cellular proteins in combination with bioinformatic tools. Furthermore, the development of such novel proteomic techniques facilitates the elucidation of the functions of proteins under stress or disease conditions, resulting in the discovery of biomarkers for responses to environmental stimuli. The ultimate objective of proteomics is targeted toward the entire proteome of life, subcellular localization biochemical activities, and the regulation thereof. Comprehensive analysis strategies of proteomics can be classified into three categories: (i) protein separation via 2-dimensional gel electrophoresis (2-DE) or liquid chromatography (LC), (ii) protein identification via either Edman sequencing or mass spectrometry (MS), and (iii) proteome quantitation. Currently, MS-based proteomics techniques have shifted from qualitative proteome analysis via 2-DE or 2D-LC coupled with off-line matrix assisted laser desorption ionization (MALDI) and on-line electrospray ionization (ESI) MS, respectively, toward quantitative proteome analysis. In vitro quantitative proteomic techniques include differential gel electrophoresis with fluorescence dyes. protein-labeling tagging with isotope-coded affinity tags, and peptide-labeling tagging with isobaric tags for relative and absolute quantitation. In addition, stable isotope-labeled amino acids can be in vivo labeled into live culture cells via metabolic incorporation. MS-based proteomics techniques extend to the detection of the phosphopeptide mapping of biologically crucial proteins, which ale associated with post-translational modification. These complementary proteomic techniques contribute to our current understanding of the manner in which life responds to differing environment.

High Performance Liquid Chromatographic Method for Determination of Metazosulfuron Residue in Representative Crops

  • Lee, Hyeri;Kim, Eunhye;Lee, Young Deuk;Kim, Jeong-Han
    • 한국환경농학회지
    • /
    • 제32권2호
    • /
    • pp.128-135
    • /
    • 2013
  • BACKGROUND: This study was performed to develop a single residue analytical method for new herbicide metazosulfuron in crops. METHODS AND RESULTS: Brown rice, apple, mandarin, Kimchi cabbage and soybean were selected as representative crops, and clean-up system, partition solvent and extraction solvent were optimized. Instrumental limit of quantitation (ILOQ), linearity of calibration curve and method limit of quantitation (MLOQ) were determined based on the chromatography and whole procedures. For recovery tests, brown rice, apple, mandarin, Kimchi cabbage and soybean samples were macerated and fortified with metazosulfuron standard solution at three levels (MLOQ, 10 MLOQ and 100 MLOQ). And then those were extracted with acetonitrile, concentrated, and partitioned with ethyl acetate. Then the extracts were concentrated again and cleaned-up through $NH_2$ (aminopropyl) SPE cartridge with acetone : dichloromethane (1% acetic acid) (20 : 80, v/v) before concentration and analysis with HPLC. CONCLUSION(S): ILOQ of metazosulfuron was 2 ng (S/N${\geq}$10) and good linearity was achieved between 0.05 and 12.5 mg/Kg of metazosulfuron standard solutions, with coefficients of determination of 0.9999. MLOQ was 0.02 mg/Kg. Good recoveries from 74.1 to 116.9% with coefficients of variation (C.V.) of less than 10% were obtained, regardless of sample type, which satisfies the criteria of Korea Food and Drug Administration (KFDA). Those results were reconfirmed with LC-MS (SIM). The method established in this study is simple, economic and efficient to be applied to most of crops as an official and general method for residue analysis of metazosulfuron.

High performance liquid chromatography에 의한 fructo 및 inulo올리고당의 정량 (Quantitation of fructo- and inulo-oligosaccharides by high performance liquid chromatography)

  • 강수일;한종인;김경연;오선진;김수일
    • Applied Biological Chemistry
    • /
    • 제36권4호
    • /
    • pp.310-314
    • /
    • 1993
  • HPLC를 이용하여 fructose oligomer인 fructo올리고당(GF2-GF7) 및 inulo올리고당(F2-F4)의 분리, 정량을 실시하였다. TSK-gel amide 80 column과 acetonitrile-water(65:35; v/v) 용매를 사용하여 각 표준당들을 효과적으로 분리할 수 있었으며 이들의 retention time은 분석시마다 거의 변하지않아 재현성이 있었다. 각 당의 농도에 따른 peak면적을 이용하여 표준곡선을 작성한 결과 넓은 당량의 범위에 걸쳐 결정계수가 0.9884이상의 값을 보여 본 HPLC방법에 의한 정량법이 타당한 것으로 나타났다. 또한 기울기는 비슷하나 y축 절편 값이 당마다 크게 상이하여 몇가지 표준당들을 기준으로 하여 모든 당을 일률적으로 정량하는 것은 적합하지 않으며 각 당에 대한 표준곡선을 하나씩 작성하여 정량하여야함을 알 수 있었다.

  • PDF

Validation of One-Step Real-Time RT-PCR Assay in Combination with Automated RNA Extraction for Rapid Detection and Quantitation of Hepatitis C Virus RNA for Routine Testing in Clinical Specimens

  • KIM BYOUNG-GUK;JEONG HYE-SUNG;BAEK SUN-YOUNG;SHIN JIN-HO;KIM JAE-OK;MIN KYUNG-IL;RYU SEUNG-REL;MIN BOK-SOON;KIM DO-KEUN;JEONG YONG-SEOK;PARK SUE-NIE
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권3호
    • /
    • pp.595-602
    • /
    • 2005
  • A one-step real-time quantitative RT-PCR assay in combination with automated RNA extraction was evaluated for routine testing of HCV RNA in the laboratory. Specific primers and probes were developed to detect 302 bp on 5'-UTR of HCV RNA. The assay was able to quantitate a dynamic linear range of $10^7-10^1$ HCV RNA copies/reaction ($R^2=0.997$). The synthetic HCV RNA standard of $1.84{\pm}0.1\;(mean{\pm}SD)$ copies developed in this study corresponded to 1 international unit (IU) of WHO International Standard for HCV RNA (96/790 I). The detection limit of the assay was 3 RNA copies/reaction (81 IU/ml) in plasma samples. The assay was comparable to the Amplicor HCV Monitor (Monitor) assay with correlation coefficient r=0.985, but was more sensitive than the Monitor assay. The assay could be completed within 3 h from RNA extraction to detection and data analysis for up to 32 samples. It allowed rapid RNA extraction, detection, and quantitation of HCV RNA in plasma samples. The method provided sufficient sensitivity and reproducibility and proved to be fast and labor-saving, so that it was suitable for high throughput HCV RNA test.